Raguraman 2-Apr-2008 B. Shukla S.W TU Unit shall be KN instead of N. Please check Add
Weight (Kg)
30
Please confirm these are
both applicable at same time
KSL shall indicate the following informations
1. Maximum allowable Residual unbalance. 2. Potential unbalance of coupling. 3. Surface finish of hub bores.
Please indicate short circuit torque (maximum