Professional Documents
Culture Documents
4.0
Release Notes
12/2020
PL20200701135016979
Guidelines
This manual contains notes of varying importance that should be read with care; i.e.:
Important:
Highlights key information on handling the product, the product itself or to a particular part of the documentation.
Note: Provides supplementary information regarding handling the product, the product itself or a specific part of
the documentation.
Trademarks
All names identified by ® are registered trademarks of Siemens AG.
The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes
could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Security information
Siemens provides products and solutions with industrial security functions that support the secure operation of
plants, systems, machines and networks. In order to protect plants, systems, machines and networks against
cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial
security concept. Siemens’ products and solutions only form one element of such a concept.
Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks. Systems,
machines and components should only be connected to the enterprise network or the internet if and to the extent
necessary and with appropriate security measures (e.g. use of firewalls and network segmentation) in place.
Additionally, Siemens’ guidance on appropriate security measures should be taken into account. For more
information about industrial security, please visit https://www.siemens.com/industrialsecurity.
Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly
recommends to apply product updates as soon as available and to always use the latest product versions. Use of
product versions that are no longer supported, and failure to apply latest updates may increase customer’s
exposure to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under https://
www.siemens.com/industrialsecurity.
Category Installation
Revision PL20200701135016979
State Published
Author Siemens AG
Language en-US
1 General Notes
Opcenter Execution Discrete functionalities - Scope
Siemens AG supports solely Opcenter Execution Discrete (Opcenter EX DS) features that are officially documented.
Any improper use of Opcenter EX DS not expressly described in official documentation will not be supported.
As a result, users must not manually launch any executables installed by Opcenter EX DS unless explicitly instructed
to do so by the DI SW Support Services or official Opcenter EX DS documentation. Likewise, users must not use any
APIs exposed by DLLs installed by Opcenter EX DS within custom applications, unless explicitly instructed to do so
by DI SW Support Services or official Opcenter EX DS documentation.
Moreover, the use of any feature not expressly authorized may compromise the proper functioning of Opcenter EX
DS: in extreme cases, such behavior may cause the relative software and/or data to become corrupted, with no
possibility of recovery.
If you need to customize the functionalities provided by default by Opcenter Execution Discrete, refer to the
indications regarding customization illustrated in the Opcenter Execution Foundation Development and
Configuration Guide.
Customizations
The possibility of customizing the product’s code is offered to System Integrators: however, keep in mind that a
clear distinction must be made between the product native code and the customization. Likewise, it is necessary
that any custom code undergo auditing prior to its execution and deployment: in alternative, the System Integrator
must provide coding guidelines, making the Customer responsible for the execution of code compliance and/or
tracking.
2 Main Functionalities
What is Opcenter Execution Discrete?
Opcenter Execution Discrete is designed to satisfy the most common needs of industries with a hierarchical
structure in which specific macro-areas are dedicated to executing discrete manufacturing functionalities in various
stages in order to produce the desired product. The industries targeted operate in the following categories:
• Automative tier suppliers
• A&D tier suppliers
• Energy & Utilities
• Industrial Machinery and Heavy Equipment
• White Goods and Home Appliances
• Complex Parts Manufacturing and Assembly.
Opcenter EX DS provides you with all basic functionalities for:
• Modeling your production environment, consisting of equipment levels, machines required for production,
work operations, tools, materials, etc..
• Defining how products are produced (that is, defining the various operations and/or steps involved in their
production).
• Creating production orders, in which you define the type of production to be adopted and the quantity to be
produced for the order you have in mind.
• Scheduling production according to your needs.
• Tracking and monitoring production, to see how the execution of your work order is progressing.
Main Features
Opcenter Execution Discrete offers the following features:
User Management
• Access Control through Roles and Certifications
• Team Management
• Labor Tracking
• Multi-Plant Support Applicable for All Entities
• System Localization
Production Management
• Native Data Definition and Management for Engineering and Runtime Needs
• Operation/Step Category Management
• Material Management
• Container Management
• Tool Management
• Barcode Management
• ID and Serial Number Generation
• Readily-Available Work Instructions and Documents
• Functionalities for As Planned BOP, Master Plan and Process Management
• Dedicated Catalogs for Reusing Processes, Operations and Steps
• Versatile Work Order Management
• Alternative Paths for Operation Execution
Production Execution
• Runtime Work Order Execution
• Result Management
• Interlocking Checks for Governing Work Order Operation Execution
The integration of external software does not imply that the product supports all the functionalities
provided by the former and that the supported functionalities are feasible in all possible configurations.
See General Notes.
3 What's New
The sections listed below provide a brief description of the features and functionalities introduced as of Opcenter
Execution Discrete 4.0.
In any case, when Result Management is enabled, the tiles representing Material Tracking Units will adopt the
NOK indicator to represent a negative Result.
The user can choose how to manage batch consumption at runtime: either as in previous versions, creating new
batches on the fly, or recreating the same Batch Id more than once until a predefined maximum quantity is
consumed.
4 Documentation
Documentation Languages
The documentation of Opcenter Execution Discrete is released in English. You can download the product
documentation (in English and Simplified Chinese) and the localized UI resources from the Support Center website
as follows:
1. Logon to https://support.sw.siemens.com/en-US/.
2. Click the Opcenter Execution Discrete home card and navigate to the following sections:
• Downloads > Additional Downloads for the UI resources,
• Documentation for the product documentation.
Available Manuals
The table below lists the currently-available Opcenter Execution Discrete manuals, which are provided in both PDF
and Documentation Center (.udoc) format:
Installation and Configuration Guide Illustrates the procedures that must be performed to install and
configure Opcenter EX DS
UI Reference and Customization Guide Provides a reference on the released UI Modules and UI
Components and a guide on how to create custom UIs using
them. The guide also contains UI customization examples.
For all Reference Guides in HTML format, we suggest using Chrome for optimal visualization.
5 Functional Limitations
Non-Conformance Customization
Customization is feasible solely for Quality Non-Conformances.
Screen Resolution
Due to scaling limitations in the Opcenter EX DS UI component, Operator Landing and Operator Details custom
pages created with the Opcenter Execution Foundation Mashup Editor may experience resizing issues below certain
screen resolutions.
Data Export-Import
For what concerns the export/import of data inherited from Opcenter EX FN, most of the master data can be
exported: however, the data related to the Process Catalog can be exported and imported, but this is not possible
for the 100% structure.
It is possible to export:
• As Planned BOPs
• Process Catalog
• Operation Catalog
• Step Catalog
provided that the Descendants checkbox is not selected at the time of export.
Therefore, it is necessary that you first perform an Export of the following (all without Descendants) in the given
order:
• AsPlanned BOPs
• Process Catalog
• Operation Catalog
• Step Catalog
and then import in the given order:
• AsPlanned BOPs
• Process Catalog
• Operation Catalog
• Step Catalog.
6 Version Compatibility
Tree UI Widget Compatibility
As of Opcenter Execution Discrete 3.2, the convention of using prefix opxexds for any new customized UI widgets
has been adopted.
In particular, to permit compatibility, for customizations prior to this release and containing tree widget sitTree, it
is necessary that this widget be manually renamed to opxexdsTree.
IdsSuccess property ( NA
UADMUpdateWOByBoPList
command)
WarningMessage property (UADMCr NA
eateWorkOrdersFromAsPlannedBO
P command)
RefNumber property ( RefNumber property (UADMAcceptChangeRepeatOperation
UADMAcceptChangeRepeatOperati command) - Mandatory
on command)
WorkOrderOperationIds property ( WorkOrderOperationIds property (
UADMAcceptChangeRepeatOperati UADMAcceptChangeRepeatOperation command) - AS list of Guid -
on command) - AS list of int Mandatory - "Length = 255" removed
WarningMessage property ( NA
UADMAcceptChangeRepeatOperati
on command)
MaterialItemIdList property (UADM NA
AcceptChangeAddDCDRuntimeTas
k command)
WorkOrderOperationSequence NA
property (UADMAcceptChangeAddO
peration command)
RefNumber property ( RefNumber property (UADMAcceptChangeChangeToBeUsedMachine
UADMAcceptChangeChangeToBeUs command) - Mandatory
edMachine command)
WarningMessage property (UADMSp NA
litWorkOrder command)
ToolNId property (UADMUseTool ToolNId property (UADMUseTool command) - AS Guid - "Length = 64"
command) - AS string removed
TimesToBeUsed property (UADMUse NA
Tool command)
AsPlannedBOPId property (UADMAc NA
ceptChangeAddProcessOperation
command)
AsPlannedBOPId property (UADMCr NA
eateWorkOrderOperationFromProc
essOperation command)
WarningMessage property (UADMCr NA
eateWorkOrderOperationFromProc
essOperation command)
NonConformanceLifecycle property NA
(
UADMAssignNonConformanceTran
sitionRoleList command)
NonConformanceLifecycle property NA
(
UADMRemoveNonConformanceTra
nsitionRoleList command)
NonConformanceLifecycle property NA
(
UADMAssignNonConformanceTran
sitionMailAddressList command)
NonConformanceLifecycle property NA
(
UADMRemoveNonConformanceTra
nsitionMailAddressList command)
WorkOrderNId property (UADMStart NA
NonProductiveActivityList
command)
WorkOrderOperationNId property (U NA
ADMStartNonProductiveActivityLis
t command)
WorkOrderStepNId property (UADM NA
StartNonProductiveActivityList
command)
EquipmentNId property (UADMStart NA
NonProductiveActivityList
command)
MaterialItemNId property (UADMSt NA
artNonProductiveActivityList
command)
Note property (UADMStartNonProd NA
uctiveActivityList command)
NonProductiveActivityHistoryList NA
property (UADMCompleteNonProdu
ctiveActivityList command)
EffectivityExpression property (Upd NA
ateMaterialDefinition command)
EffectivityExpression property (UAD NA
MUpdateToolDefinition command)
MDUI Modules
Some Standard UI Modules (those having extension .json) have been migrated to MDUI technology and deprecated.
Refer to the list in the table below.
If you are upgrading from old versions and you have previously customized these modules, you must recreate the
MDUI pages and re-implement your customization from scratch.
For more information on how to work with and extend Model-driven UI modules, refer to How to Extend
User Interfaces in an Extension App in the Opcenter Execution Foundation Development and Configuration
Guide.
Deprecation Alternative
Deprecation Alternative
UI Components
Deprecated as of version 3.1
Deprecation Alternative
AppU4DM App
Deprecated as of version 3.1
Deprecated Alternative
Command Command
UADMSentenceNonConformance UADMSentenceNonConformanceV3_1
Deprecated Alternative
Command Command
UADMSentenceNonConformancePartially UADMSentenceNonConformanceV3_1
Command Command
UADMCreateNonConformance UADMCreateNonConformanceV3_1
Property Property
InspectedQuantity in NonConformance entity Quantity
Property Property
NonConformanceQuantity in Quantity
NonConformance entity
Property Entity
MaterialDefinition in NonConformance entity NonConformanceItem
Property Entity
ToolDefinition in NonConformance entity NonConformanceItem
Property Entity
SerialNumber in NonConformance entity NonConformanceItem
Deprecated Alternative
Deprecated Alternative
Deprecated Alternative
Deprecated Alternative
Command Command
UADMCreateEquipmentSpecificationWithPrintJo CreateEquipmentSpecificationWithPrintJobFile
bFile
Command UADMCreateNewProcessRevision Command CreateNewProcessRevision
Command UADMCompleteAsPlannedBOP Command CompleteAsPlannedBOP
Command UADMDeleteAsPlannedBOPList Command DeleteAsPlannedBOPList
Command UADMDeleteStepList Command DeleteStepList
Command UADMLinkHumanResourceToProcess Command LinkHumanResourceToProcess
Command Command UnlinkHumanResourceFromProcess
UADMUnlinkHumanResourceFromProcess
Deprecated Alternative
Command Command
PLMAssociateDocumentToMaterialDefinitionList PLMAssociateDocumentToMaterialDefinitionList
exposed by BoP App
Command Command
PLMAssociateDocumentToToolDefinitionList PLMAssociateDocumentToToolDefinitionList exposed
by BoP App
Command Command PLMAssociateDocumentToOperationList
PLMAssociateDocumentToOperationList exposed by BoP App
Command PLMLinkProcessToOperationFullList Command PLMLinkProcessToOperationFullList
exposed by BoP App
Command PLMLinkOperationToStepFullList Command PLMLinkOperationToStepFullList exposed
by BoP App
Command Command
PLMCreateStepMaterialSpecificationFullList PLMCreateStepMaterialSpecificationFullList exposed
by BoP App
Command Command PLMCreateStepToolSpecificationFullList
PLMCreateStepToolSpecificationFullList exposed by BoP App
Command Command
PLMCreateOperationEquipmentSpecLocationFul PLMCreateOperationEquipmentSpecLocationFullList
lList exposed by BoP App
Deprecated Alternative
Command Command
PLMCreateOperationMaterialSpecificationFullLi PLMCreateOperationMaterialSpecificationFullList
st exposed by BoP App
Command Command
PLMCreateOperationToolSpecificationFullList PLMCreateOperationToolSpecificationFullList
exposed by BoP App
Command Command
PLMCreateOperationHRSpecificationFullList PLMCreateOperationHRSpecificationFullList exposed
by BoP App
Command Command PLMCreateStepHRSpecificationFullList
PLMCreateStepHRSpecificationFullList exposed by BoP App
Deprecated Alternative
FB_MS_BOP
Deprecated as of version 3.0
Deprecation Alternative
Event Event
OnPLMCreateOperationEquipmentSpecLocationList OnPLMCreateOperationEquipmentSpecLocationF
ullList
Event N.A.
OnPLMCreateOperationEquipmentSpecResourceDef
initionFullList
Event N.A.
OnPLMCreateOperationEquipmentSpecResourceDef
initionList
Event N.A.
OnPLMCreateOperationEquipmentSpecResourceFul
lList
Event N.A.
OnPLMCreateOperationEquipmentSpecResourceList
Event Event
OnPLMCreateOperationMaterialSpecificationList OnPLMCreateOperationMaterialSpecificationFullL
ist
Deprecation Alternative
Deprecated Alternative
FB_OP_RUNTIME
Deprecated as of version 3.1
Deprecation Alternative
Command Command
SentenceNonConformance SentenceNonConformanceV3_1
Command Command
SentenceNonConformancePartially SentenceNonConformanceV3_1
Command Command
CreateNonConformance CreateNonConformanceV3_1
Property Property
InspectedQuantity in NonConformance entity Quantity
Property Property
NonConformanceQuantity in NonConformance entity Quantity
Property Entity
MaterialDefinition in NonConformance entity NonConformanceItem
Deprecation Alternative
Property Entity
ToolDefinition in NonConformance entity NonConformanceItem
Property Entity
SerialNumber in NonConformance entity NonConformanceItem
FB_MS_MatTool
Deprecated as of version 3.2
Deprecation Alternative
Command Command
CreateSkill CreateSkill_BOP
in FB_MS_BOP Functional Block
Deprecated as of version 4.0
Deprecation Alternative
FB_MS_Mat
Deprecated as of version 4.0
Deprecation Alternative
186720 Materials Page - Material deletion - System allows Materials to be deleted although linked to
released WO as a Final Material
After creating a Material and setting it as the Final Material of a Work Order that is then
released, if you attempt to delete this Material, the Work Order will appear without a value for
Final Material. Instead, the system should not allow the deletion of Materials if they are
already linked to a released Work Order.
Likewise, users should not be allowed to delete Materials linked to other entities.
192545 Tool Component - Operator Details Page - Textbox should be an entity picker
Inside the Tool Component, the panel must be opened in order to see the item.
230637 Opcenter EX DS 3.1 - Bug when the user logs in to system with upper-case and lower-case
chars
The system makes a distinction between upper-case and lower-case characters when log-in is
performed.
242102 DCD Acquire button for semi-automatic data acquisition is not available for Step
The DCD Acquire button for semi-automatic data acquisition is not displayed for Steps.
277659 Process Evolve As Planned BOP command - Evolving the Process As Planned BOP, the system
cuts the original baseline name if an underscore is present in the name
When evolving the Process As Planned BOP, if the original baseline name contains an
underscore, the system does not add the number of times the Process As Planned BOP has
been evolved at the end of the complete original baseline name. Instead, it leaves out the
portion of the baseline name following the underscore.
For example, if the original baseline name is "PBOP_Demo001", the system erroneously
creates the evolved baseline as "PBOP_2", instead of "PBOP_Demo0012".
279298 UADMCreateOperation Command: Creating an Operation for MasterPlan and Process Page
with Create Dependency enabled and Dependency Type set generates error
The user should create dependencies with ad hoc functionality in case of Master Plans.
ID Description
188905 Uadm 2.5 - Search Filters do not mantain searched value when the key is set true if a Proxy is
enabled.
222374 OPCENTER_EX 3.2 - Anomaly behavior on Edit a non-conformance when we refresh the page
223772 OPCENTER_EX 3.2 - Anomaly behavior on Edit a non-conformance when we refresh the page
228935 OPCENTER_EX 3.1 - "New defect" panel too small to show complete description for a defect
234339 OPCENTER_EX 3.3 - Unlink of a MTU from a Non-Conformance, Qty of Nc not reloaded
234710 OPCENTER_EX 3.3 - Cannot Start WorkOrderOperation in Operator Landing page when user view
in gridmode
234931 OPCENTER_EX 3.3 - SN remains displayed in the Start panel after complete
236302 OPCENTER_EX 4.X - Error on Start\ Pause\Start - WorkOrderOperation (transferbatch) with start
qty on different units
236602 OPCENTER_EX 3.2 - Edit WO qty does not update to be consumed materials quantities or to be
used to
236628 Uadm - Wrong consume when using same BatchId against different MaterialDefinition version
238977 OPCENTER_EX - work Instruction is not visible in Work order step at runtime
239001 OPCENTER_EX - Cannot Skip WorkOrderOperation in Operator Landing page when user view in
gridmode
239868 OPCENTER_EX 3.1 - Error occur in work order update 2(opcenter standard functionality error)
240196 PJF/DNC Integration - Print Job File/Part Program Not Filtered on Work Orders and Processes
pages
240855 OPCENTER_EX 3.1 - Work Orders of Dependencies are not sufficiently displayed
241492 OPCENTER_EX - Operation disappeared from OLP but is not fully completed
ID Description
241710 OPCENTER_EXDS 3.1 - Facing issue in Inspection role defined during operation creation
241711 OPCENTER_EXDS 3.1 - Work Order Operation Detail: error in format of date "Actual End"
241713 OPCENTER_EXDS 3.1 - Add a visual cue to indicate if Work Order process and the data source
mismatch
241769 OPCENTER_EXDS 3.1 - Are UoM + Value related to the Weight/Volume UoM + Value?
241796 OPCENTER_EX 3.2 - Hyperlink does not work in work instruction runtime
242105 Change NC : Accept change for repeat and add operation issue
242168 OPCenter 3.2 - Disconnected Work Orders Relationship with Execution Group
242767 OPCENTER_EXDS 3.2 - Produced Quantity of Work Order is not updated (for all production types)
242915 OPCenter 3.2 - Missing Certification Info in Process Operation Details Page
243047 Unable to extend DCD with custom parameters coming from CLM
245786 OPCenter 3.2 - Start on serialized WO after pause by another user. Paused serials are shown as
246540 OPCENTER_EXDS 3.2 - Not possible to associate same WI params to Automation Instance params
assigned to different Unit
248586 Closing Flexible WO: incorrect management of 'Close Flexible WO' option
248726 OPCENTER_EXDS 3.2 - Operator landing - Filter clause disappears after navigating to another page
249011 OPCENTER_EXDS 3.2 - Operator landing - Need operation name instead of cryptic NId while
creating NPA
249034 Process Page - Sequence : Sequence number is not displayed if you create a dependency between
Operations
ID Description
249057 FR language - Certifications / Users Assigned – control validation expiration date doesn’t allow
months in French
249058 "The node count limit of 150 has been exceeded" when operation is selected on operator landing
249220 OPCENTER_EX 3.1 - Timeout Error in Data Import from BGS (CLM4S) to OpCenter Execution
Discrete
249749 OPCENTER_EXDS 3.2 - Certification (Chinese) - While adding user/role to certificate, exception
thrown while entering date
249874 OP Center 3.2 - Production coordinator dashboard does not show active workordersoperations on
unit
249963 Genealogy Page - UoM for assembled material : The Unit of Measure (UoM) attribute associated
with the consumed material in a Work Order Operation is not shown.
250148 OP Center 3.2 - Process Operation Dependencies not usable with longer Operation Names
250171 OP Center 3.2 - Genealogy: incorrect management of Material Produced and Material Consumed
250576 OP Center 3.2 - Unable to schedule resource to Work Order and Execution Group
250876 OP Center 4.x- Jump from Step/Skills to Step catalog will lose the selection
250895 OP Center 4.x- No information on events that triggers notifications on Preactor-Alerts window
251425 Incorrect management of Material Creation from 'Material Details' page: caught exception
251437 OPCENTER_EXDS 3.2 - Wrong Flexible Serialized Consumed Material Quantity after edit of Planned
Target Qty
251775 MTU/quantity not propagate correctly on work order operation after scrap the MTU/Batch
quantity
251791 OPCENTER_EXDS 3.2 - Operator Landing Page -> SN Tab is visible even if there is no SN associated
to WI
251846 Identifier Format does not work with Work Order Identifier
ID Description
252066 OPCENTER_EXDS 3.2 - Operator Landing Page -> "Add Documents" button not enabled
254286 OPCENTER_EX- Key to see only operations ready to start does not consider dependencies between
orders.
254786 Opcenter EX DS 3.1 - Acquire button of WI not appearing in runtime which is attached in WOstep
level
255300 OPCENTER_EX - The event OnCreateWorkOrder is not raised when a WorkOrder is created
256033 Execution group does not display the machines under a work centre when starting
256614 Opcenter EX DS 3.1 - Hold Functionality not working - refer to old #IR 9721930s Field Fix
256874 OPCENTER_EX 3.2 -Split on serialized workorder Serial numbers cannot be associated
262804 Opcenter EX DS 3.1 - Operator Landing Page: Unable to filter the work order operations based on
an Equipment
262929 OPCENTER_EX 3.2 - Execution groups do not show on the operator landing
263704 OPCENTER_EX 3.3 - Could not link user to WOO in Production Coordinator Dashboard at first load
264505 Opcenter EX DS 3.1 - MTU Page - Property tab : it's not possible to see Property assigned to the
material linked to MTU
264508 [5001]Exception in execution error is coming when trying to complete WOO when Wo
ID Description
264509 Future hold is not getting closed even after NC is resolved(In case of MaterialI
264511 OPCENTER_EX 3.1 -Ref to IR#9839162 Cumulative FFX caused Scrap Quantity issue on WOO
264627 "Actual Start" field update in Work Order Operation table after pausing an operation
266013 OPCENTER_EX 3.3 - Non-Conformance Details does not show work order operation name only
cryptical
266040 OPCENTER_EX 3.3 -Operator Landing Detail Mashup wiring missing event and method
266325 OPCENTER_EX 3.3 - Issue with Flexible-Batch Order and Non-Conformance Scrapping
266597 OPCENTER_EX 3.3 - Not able to start a WOO with a Container correctly associated
268399 OPCENTER_EX - PCD Page: label on Filter for operation status not clear
268593 OPCENTER_EX 3.3 -Several issues with quantity fields of flexible and non flexible work orders
268661 Quantity of Non Conformance is not updated correctly for completed quantity and consumed
material quantity
268734 OPCENTER_EX 3.3 -Not able to start a WOO with a Container correctly associated
269853 On selecting two items in the list, the Delete function deletes only one entry
270504 Opcenter EX DS 3.2 - Operator landing page: "Interlocking Check History" button is disabled
270887 OPCENTER_EX - Icons and menus have changed after reloading AppU4DM
272167 OPCENTER_EX 3.3 - Pre-kit function cannot be used in the Work order operation Step
ID Description
272501 Filter of "non productive activities" in windows "create new NPA" not refreshing
273260 OPCENTER_EX - Operator Landing Page - Filter for SN/Machine and container doesn't work
273325 OPCENTER_EX - Add multiple tools to operation/step fails saying it already exists
273913 Documentation - Create Work Order ID with Template - Counter greater than 200
274031 OPCENTER_EX - PCD Page: label on Filter for Operation status not clear
274805 Opcenter EX DS 3.2 - Migration from 2.3 to 3.2 Non Conformances problem
275250 OPCENTER_EX - Missing fire event (OnSetHoldWorkOrder and onRemoveHoldWorkOrder) from 2.3
to 3.2 version
278931 OPCENTER_EX - UseToolList command generates Error Code 703127 on Tool with facet
279571 Issue with To Be Consumed Material quantity in flexible serialized Work Order
282246 Opcenter EX DS 3.3 - Linking between IdentifierTemplates and Materials not based on unique
identifier