Professional Documents
Culture Documents
1
Pre-Qualification
UNiTED SYSTEM
Index
United Mining Industries
Company Profile
Environment Friendly
Legal Documents
Draft Warranty
List of Projects
www.ugc.com.sa 2
Pre-Qualification
UNiTED SYSTEM
What is UMI ?
United Mining Industries is a joint-Venture of three major companies in
construction and Building Materials Industry in GCC which are Al Muhaidip, AL
Mojel and Al Rashed. UMI aims to enhance the quality of Gypsum Products in local
and regional market and provide efficient & Economical solutions for the shortage
in housing locally & regionally. Having raw material, low energy cost and being
located in the middle of the region help to provide building and housing sectors
with un-costly high quality Gypsum & Cement Board Products in short notice.
Beside the raw material quarries, the manufacturing facility in Yanbu-KSA built
over an area of 114,000 m² to include Head office, gypsum Powder Plant, Gypsum
Board Plant, Ware House and facility buildings, with capacity of production of 34
million m² and can reach up to 50 millions m².
www.ugc.com.sa 3
Pre-Qualification
UNiTED SYSTEM
UMI’s mission to enhance the quality of Fiber Cement Board products in local and
regional market to provide efficient, eco-friendly and economical solutions. Having
locally procured major raw materials (excluding Fiber Pulp), low energy cost and
being located in the middle of the region helps us to provide excellent Product to
help sustain Green Building Solutions. Our aim is to save environment and protect
our ecological atmosphere. We use GREEN materials to produce and FCB is
recyclable and degenerate material. UNICEM Fiber Cement Boards are
manufactured to meet requirements of ISO 8336:2009 and ASTM C1186 (2012).
www.ugc.com.sa 4
Pre-Qualification
UNiTED SYSTEM
A TRUSTED LEADERSHIP
UMI is a leading company in manufacturing excellent gypsum board products and
delivering unmatched services to achieve ultimate customer satisfaction. A unique,
professional commitment to the highest level of customer service; a strong belief
in teamwork; modern production facilities with advanced technology and state-of-
the-art manufacturing equipment create a consistent quality product and a
company that surpasses the industry .UMI commitment to quality insures a
dynamic and financially strong corporation that excels at changing the lifestyles of
people.
OUR VALUES
Integrity Mutual Trust
Innovation Teamwork
www.ugc.com.sa 5
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 6
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 7
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 8
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 9
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 10
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 11
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 12
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 13
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 14
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 15
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 16
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 17
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 18
Pre-Qualification
UNiTED SYSTEM
Our
systems
RANGE
www.ugc.com.sa 19
Pre-Qualification
UNiTED SYSTEM
UNITED DRYWALL
A drywall is a Quick and simple
construction with high-quality & high
performance lightweight interior
wall system consisting of a GI steel frame
encased with gypsum plasterboards on either
side attached with self-drilling drywall screws.
The joints are then taped and finished
with gypsum jointing compounds. There are
many types depending on the activity and the
place where it will be installed.
DURABLE - High levels of impact resistance to meet and surpass BS 5234 Severe Duty
rating.
SUSTAINABILITY Our gypsum plasterboards are 100% recyclable into new
plasterboard. Installation reduces site water consumption, compared to traditional
brick and block.
www.ugc.com.sa 20
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 21
Pre-Qualification
UNiTED SYSTEM
DRYWALL SYSTEMS DESIGNED TO MEET PROJECT REQUIREMENTS
There are many types solutions offered by United Systems depending on the activity and the
place where it will be installed. Based on the projects requirement complying with Standards.
STANDARDS COMPLY
PRODUCTS SPECIFICATIONS
ASTM C 1396/ C 1396M: Standard Specification for Gypsum Board
PRODUCTS TESTING
ASTM C 473: Standard Test Methods for Physical Testing of Gypsum Panel Products
ASTM E 84: Standard Test Method for Surface Burning Characteristics of Building Materials
SYSTEM TESTING
ASTM E 119: Standard Test Methods for Fire Tests of Building Construction and Materials
ASTM E 90: Standard Test Method for Laboratory Measurement of Airborne Sound
Transmission Loss of Building Partitions and Elements
SYSTEM INSTALLATION
ASTM C 754: Standard Specification for Installation of Steel Framing Members
ASTM C 840: Standard Specification for Application and Finishing of Gypsum Board
www.ugc.com.sa 22
Wet Area Ceiling Solution Dry & Wet Area Walls Solution
– Non Performance (MR) – Fire Rated (MRFW)
www.ugc.com.sa
Dry/Wet Area Walls Wet Area Walls Solution
Solution – Sound Rated (MR)
– Non Performance
Wet Area Shaft Walls
Dry Area Walls Solution
Solution – Fire Rated
– Fire Rated (FW)
(MRFW)
23
UNITED DRYWALL & CEILING SOLUTIONS
UNiTED SYSTEM
Pre-Qualification
Pre-Qualification
UNiTED SYSTEM
UGD1 – UNITED DRYWALL SINGLE LAYER SYSTEM
www.ugc.com.sa 24
Pre-Qualification
UNiTED SYSTEM
UGD2 – UNITED DRYWALL DOUBLE LAYER SYSTEM
Note:
* Based on the performance requirement, the plasterboard needs to be selected – Regular for
general applications; MR for Humidity area application; FW for enhanced fire resistance & for better
acoustic; Hard Board for enhanced Impact resistance etc..
* Stud spacing and metal thickness will be determined by the partition height, deflection limit and
lateral pressure. Min. recommended metal thickness is 0.55mm for fire rated partitions.
www.ugc.com.sa 25
Pre-Qualification
UNiTED SYSTEM
UGDTS – UNITED DRYWALL TWIN STUD SYSTEM – CHASE WALL
Note:
* Based on the performance requirement, the plasterboard needs to be selected – Regular for
general applications; MR for Humidity area application; FW for enhanced fire resistance & for better
acoustic; Hard Board for enhanced Impact resistance etc..
* Stud spacing and metal thickness will be determined by the partition height, deflection limit and
lateral pressure. Min. recommended metal thickness is 0.55mm for fire rated partitions.
www.ugc.com.sa 26
Pre-Qualification
UNiTED SYSTEM
UGDTS – UNITED DRYWALL TWIN STUD SYSTEM
Note:
• comprises of multiple layers of gypsum boards on Outer Side of Twin UC structure having parallel
row of tracks and studs. The parallel rows of studs are braced with V Brace or The same Framing
Profile or with the Gypsum Boards , at defined horizontal heights for various acoustic performance
requirements. Filling each stud cavity with acoustic insulation, will enhance acoustical Rating of the
system
• Based on the performance requirement, the plasterboard needs to be selected – Regular for
general applications; Moisture Resistant for Humidity & Tile Baking area application; Fire Resistant
& Hard Boards for enhanced fire Resistance & for better acoustic, Hard - for enhanced Impact
Resistance etc.
• Depends on The wall height & Wall width the Gi Framing will be deigned. Some of walls will have
Acoustic V-Brace when the Project requires High Walls
www.ugc.com.sa 27
Pre-Qualification
UNiTED SYSTEM
UGSW – UNITED SHAFTWALL SYSTEM
UMI CH Stud
Insulation
UNiTED J-Runner
Track
Note:
• Ideal for elevator shafts since the walls can be constructed from one side, leaving the shaft free of
scaffolding. This allows elevator equipment to be installed simultaneously. Shaft Wall Systems provide
superior safety and performance for an important building component such as Elevator, MEP Shafts,
stairwells, air return shafts and horizontal membranes
• Incase of Crowd or High impact area replace the 15 FMR with Hard boards
www.ugc.com.sa 28
Pre-Qualification
UNiTED SYSTEM
UGSDX – UNITED GYPSUM X-RAY ROOM PARTITION SYSTEM
Bracing as Recommended
United Stud as Recommended
United X-Ray Board as
Recommended
United Sealant as
Recommended
Performances:
• Fire rating 120 Minutes ( max. )
• Acoustic Isolation – 55 dB ( max. )
Note:
• United X-Ray room Drywall Comprises of double layer partition, with single layer of 3mm
Lead Laminated ( X-Ray ) board fixed up to the height of X-ray’s Source passing. The X-
ray board consists of 3mm lead sheet laminated on a special gypsum board. Lead strips
of 3mm thick x 40mm width is glue fixed on the metal studs along the flanges facing the
X-ray source before installing the boards to stop the rays from the board joints.
www.ugc.com.sa 29
Pre-Qualification
UNiTED SYSTEM
UDLF – UNITED DEPENDENT WALL LINING SYSTEM
Application:
Wet Area Wall cladding
Decorative wall cladding
Furring Channel
Fisher with
Screw
United MR Board
or UNICEM FCB
United L Angle
Wall Angle
www.ugc.com.sa 30
Pre-Qualification
UNiTED SYSTEM
UDLS – UNITED IN-DEPENDENT WALL LINING SYSTEM
UNITED Board
UNITED Framing - Stud
www.ugc.com.sa 31
Pre-Qualification
UNiTED SYSTEM
UGCF – UNITED DRY AREA CEILING SYSTEM WITH FURRING & MAIN CHANNEL
Note:
• Metal Profiles – Size, Thickness & Centers may differ based on the Project Requirement
• Sealant usage based on the performance requirement
• Suspension Height Based on the Project Requirement
• No additional Loads are considered in framing Design
Furring Fixing Details Furring Fixing Details Furring & Wall Angle
Connection Details
www.ugc.com.sa 32
Pre-Qualification
UNiTED SYSTEM
UGCF – UNITED WET AREA CEILING SYSTEM WITH FURRING & MAIN CHANNEL
Note:
• Metal Profiles – Size, Thickness & Centers may differ based on the Project Requirement
• Sealant usage based on the performance requirement
• Suspension Height Based on the Project Requirement
• No additional Loads are considered in framing Design
Furring Fixing Details Furring Fixing Details Furring & Wall Angle
Connection Details
33
www.ugc.com.sa
Pre-Qualification
UNiTED SYSTEM
UGCF – UNITED WET AREA CEILING SYSTEM WITH FURRING & MAIN CHANNEL
Note:
• Metal Profiles – Size, Thickness & Centers may differ based on the Project Requirement
• Sealant usage based on the performance requirement
• Suspension Height Based on the Project Requirement
• No additional Loads are considered in framing Design
Furring Fixing Details Furring Fixing Details Furring & Wall Angle
Connection Details
34
www.ugc.com.sa
Pre-Qualification
UNiTED SYSTEM
UGGR – UNITED GCT / FCT CEILING GRID SYSTEM
Main Runner
• 595x595,
• 603x603,
• 1200 x 600
www.ugc.com.sa 35
Pre-Qualification
UNiTED SYSTEM
UGCF – UNITED FIRE RATED CEILING SYSTEM
United Main
Channel 38 x 12/12
United
X 1.5mm @ 900mm
Recommended
ctcs max.
50mm thick 2 layer 15mm thk
Rockwool Insulation United Fire Resistant
40 kg/m3 Gypsum Board fixed
to Furring Channel.
United Wall
Angle 25 x 25 x
0.60mm fixed
@ 600mm ctc
max.
Note:
• Metal Profiles – Size, Thickness & Centers may
differ based on the Project Requirement
• Acoustic Sealant usage based on the
performance requirement
• Suspension Height Based on the Project
Requirement
• Additional loading details on the Ceiling must be
informed prior to ceiling design
• Penetrations or any cutouts in the ceiling may
effect the performance rating
www.ugc.com.sa 36
Pre-Qualification
UNiTED SYSTEM
UGCF – UNITED CINEMA CEILING SYSTEM WITH PHOENIC U HANGERS
Note:
• Metal Profiles – Size, Thickness & Centers may
differ based on the Project Requirement
• Acoustic Sealant usage based on the
performance requirement
• Suspension Height Based on the Project
Requirement
• Additional loading details on the Ceiling must be
informed prior to ceiling design
• Penetrations or any cutouts in the ceiling may
effect the performance rating
www.ugc.com.sa 37
Pre-Qualification
UNiTED SYSTEM
UDCS – UNITED DRYWALL CINEMA SYSTEMS
Note:
• comprises of multiple layers of gypsum boards on Outer Side of Twin UC structure having
parallel row of tracks and studs. The parallel rows of studs are braced with V Brace or The
same Framing Profile or with the Gypsum Boards , at defined horizontal heights for
various acoustic performance requirements. Filling each stud cavity with acoustic
insulation, will enhance acoustical Rating of the system
• Based on the performance requirement, the plasterboard needs to be selected – Regular
for general applications; Moisture Resistant for Humidity & Tile Baking area application;
Fire Resistant & Tuff Boards for enhanced fire Resistance & for better acoustic, Tuff - for
enhanced Impact Resistance etc.
• Depends on The wall height & Wall width the Gi Framing will be deigned. Some of walls
will have Acoustic V-Brace when the Project requires High Walls
www.ugc.com.sa 38
Pre-Qualification
UNiTED SYSTEM
UNITED DRYWALL & CEILING SOLUTIONS
UNITED PRODUCTS & SYSTEMS CERTIFICATION
by by by
In Progress
www.ugc.com.sa 39
Pre-Qualification
UNiTED SYSTEM
RANGE
www.ugc.com.sa 40
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 41
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 42
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 43
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 44
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 45
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 46
Pre-Qualification
UNiTED SYSTEM
UNITED PREMIUM GYPSUM BOARDS RANGE & SPECIFICATIONS
UMI offers, different types of Gypsum ( Premium & Regular ) Boards for different types of
Drywall & Ceiling application based on the site conditions.
Regular Gypsum Boards
Fire Resistant Gypsum Boards
Moisture Resistant Gypsum Boards
Mold & moisture Resistant Gypsum Boards
Fire & Moisture Resistant Gypsum Boards
Tuff ( Impact Resistant ) Gypsum Boards
UMI Gypsum Boards are manufactured as per ASTM & EN Standards and comply with
ASTM & EN Specifications & Physical Properties requirement.
UNITED REGULAR GYPSUM BOARD
United Regular Gypsum Boards are produced from high purity natural gypsum core to offer its
consistent properties and Mechanical strength to the boards. The core is encased in dense natural-
finish paper liners.
Thickness : 8, 9, 10, 12, 12.5, 15, 16 & 18 mm
Edges : Taper Edge, Square, Bevel Edge
Width : 900, 1200, 1218 mm
Length : 2400mm ( Also customized sizes based on requirement )
Standards Comply to ASTM C1396/ C1396M & EN 520 Type A
UNITED FIRE RESISTANT GYPSUM BOARD
United Fire Resistant Gypsum Boards are produced from high purity natural gypsum core to offer its
consistent properties and Mechanical strength. And additional of glass fibres and the special
additives used to improve the cohesive properties and fire integrity properties providing greater
fire resistance. The core is encased in dense natural-finish paper liners. .
Thickness : 8, 9, 10, 12, 12.5, 15, 16 & 18 mm
Edges : Taper Edge, Square, Bevel Edge
Width : 900, 1200, 1218 mm
Length : 2400mm ( Also customized sizes based on requirement )
Standards Comply to ASTM C 1396/ C1396M Type X; EN 520 Type D, I & F
www.ugc.com.sa 47
Pre-Qualification
UNiTED SYSTEM
UNITED PREMIUM GYPSUM BOARDS RANGE & SPECIFICATIONS
UNITED MOISTURE RESISTANT GYPSUM BOARD
United Moisture Resistant Gypsum Boards are produced from high purity natural gypsum core to
offer its consistent properties and Mechanical strength. And additional of special additives like
water repellent agents are used to improve the consistent properties Regular with Moisture
Resisting properties. The core is encased in dense natural-finish papers..
Thickness : 8, 9, 10, 12, 12.5, 15, 16 & 18 mm
Edges : Taper Edge, Square, Bevel Edge
Width : 900, 1200, 1218 mm
Length : 2400mm ( Also customized sizes based on requirement )
Standards Comply to ASTM C1396/ C1396M & EN 520 Type A & H
UNITED MOLD & MOISTURE RESISTANT GYPSUM BOARD
United Fire Resistant Gypsum Boards are produced from high purity natural gypsum core to offer its
consistent properties and Mechanical strength. And additional of glass fibres and the special
additives used to improve the cohesive properties and fire integrity properties providing greater
fire resistance. The core is encased in dense natural-finish paper liners. .
Thickness : 8, 9, 10, 12, 12.5, 15, 16 & 18 mm
Edges : Taper Edge, Square, Bevel Edge
Width : 900, 1200, 1218 mm
Length : 2400mm ( Also customized sizes based on requirement )
Standards Comply to ASTM C1396/ C1396M & EN 520 Type A & H
UNITED FIRE & MOISTURE RESISTANT GYPSUM BOARD
United Fire & Moisture Resistant Gypsum Boards are produced from high purity natural gypsum
core to offer its consistent properties and Mechanical strength. And additional of glass fibres and
the special additives used to improve the cohesive properties and Fire integrity & Moisture
Resisting properties providing greater fire resistance. The core is encased in dense natural-finish
paper liners.
Thickness : 8, 9, 10, 12, 12.5, 15, 16 & 18 mm
Edges : Taper Edge, Square, Bevel Edge
Width : 900, 1200, 1218 mm
Length : 2400mm ( Also customized sizes based on requirement )
Standards Comply to ASTM C1396/ C1396M Type X; EN 520 Type D, I , H & F
www.ugc.com.sa 48
Pre-Qualification
UNiTED SYSTEM
UNITED PREMIUM GYPSUM BOARDS RANGE & SPECIFICATIONS
UNITED SHAFT CORE ( FMR ) GYPSUM BOARD
United Fire & Moisture Resistant Gypsum Boards are produced from high purity natural gypsum
core to offer its consistent properties and Mechanical strength. And additional of glass fibres and
the special additives used to improve the cohesive properties and Fire integrity & Moisture
Resisting properties providing greater fire resistance. The core is encased in dense natural-finish
paper liners.
Thickness : 25 mm
Edges : Taper Edge, Square, Bevel Edge
Width : 600 mm
Length : 1800 to 3600mm
Standards Comply to ASTM C1396/ C1396M Type X; EN 520 Type D, I , H & F
UNITED HARD GYPSUM BOARD
United Hard Gypsum Boards are produced from high purity natural gypsum core to offer
better resist surface abrasion and indentation. By incorporating additional core
reinforcement and enhanced facings ( with denser paper ) that provide greater resistance
to more significant impact. And additional of glass fibres and the special additives used to
improve the cohesive properties and Fire integrity & Moisture Resisting properties
providing greater fire resistance. The core is encased in dense natural-finish paper liners.
Thickness : 12.5, 15, 16 & 18 mm
www.ugc.com.sa 49
Pre-Qualification
UNiTED SYSTEM
UNITED CEMENT BOARDS RANGE & SPECIFICATIONS
UNITED FIBRE CEMENT BOARD ( FCB )
UNiCEM United fibre Cement Boards are made from a mix of cement, Cellulose fibre and fire resistant fillers
on Hatschek machines. The products having excellent resistance again. UNiCEM United fibre Cement Boards
are produce as per ASTM C 1186 Type “A” (Direct Exposure to Sun, Rain and Snow) Standard Specification for
Exterior Grade Flat fibre Cement Boards.
Standards Comply to ASTM C1186 – Grade I, II & III
GRADES AVAILABLE:
•UNICEM FCB - GRADE 1
•UNICEM LINER HD - GRADE 2
UNICEM Square
6, 9, 12, 15, 16 & 18 1200 & 1220 2400 & 2440
Edge
UNICEM Plank
7.5 & 8 150 & 200 2400 & 3000
Wood Texture
Textured Board
9 & 12 1200 & 1220 1200 & 2400
For Cladding
UNICEM Ceiling 600, 610, 1200 &
5&6 600 & 610
PVC & Textured 1220
UNICEM SWP 2400, 2700, 3000
5&6 600 & 610
Boards SQ Edge & 3600
Thermal Conductivity:
UNICEM United Fibre Cement Boards are test for 0.21 W/mK for 6mm thick board.
Effect of Temperature:
UNICEM United Fibre Cement Boards are not recommended to be stored in temperature
above 500 for prolonged period.
Effect of condensation:
UNICEM United Fibre Cement Boards are vapour permeable. If vapour condenses on the
surface, the board will retain its strength.
www.ugc.com.sa 50
Pre-Qualification
UNiTED SYSTEM
UNITED DRYWALL METAL PROFILES & SPECIFICATIONS
STEEL SPECIFICATIONS
Our Metal Sections are manufactured using hot dipped zinc coated steel - Z180 & Z275
UNITED STUDS
Studs are the Primary sections used in the Drywall & Lining Systems. Studs used in Vertical
condition at appropriate centers to match the structural stability based on the design. Studs
are fixed between the Base & Head Track, Screwed only with the Base track & Friction fit at
the Head Track.
Thickness : 0.55, 0.60, 0.80, 0.90, 1.20 & 1.50 mm
Width: : 50, 64, 70, 75, 90, 100, 125 & 150 mm
Flange : 34/36 mm
Length : 3000mm & Customized Length
Standards Comply to ASTM C 645 & ASTM C 653
UNITED DEFLECTION TRACK
Deflection Tracks are used at the top as Head Tracks. Which helps to allow the partitions,
when needs a movement (up, down) within the structure at the head of a partition.
Deflection Tracks Secured with appropriate anchors at Concrete Slab & Hold the studs in
position and it helps in aligning the Boards.
Thickness : 0.80, & 0.90 mm
Width: : 50, 64, 70, 75, 90, 100, 125 & 150 mm
Flange : 50 mm
Length : 3000mm
Standards Comply to ASTM C 645 & ASTM C 653
UNITED TRACK
Tracks are the Secondary sections used in the Drywall & Lining Systems. Tracks used in
Horizontal condition & Secured with appropriate anchors at Floor Slab & Soffit. Tracks Hold
the studs in position and it helps in aligning the Boards.
Thickness : 0.55, 0.60, 0.80, 0.90, 1.20 & 1.50 mm
Width: : 50, 64, 70, 75, 90, 100, 125 & 150 mm
Flange : 30 mm
Length : 3000mm
Standards Comply to ASTM C 645 & ASTM C 653
www.ugc.com.sa 51
Pre-Qualification
UNiTED SYSTEM
UNITED SHAFTWALL PROFILES & SPECIFICATIONS
UNITED SHAFTWALL ( CH ) STUDS
United Ch Studs are specially designed for the Shaftwall systems sed in framing applications
as wall bracing which provides significant resistance to lateral loads & to Backup the Board
Joints
Thickness : 0.55 & 0.80 mm
Width: : 64 & 100
Length : 3000mm & Customized Length
UNITED E STUD
E Studs are the Starter & End member for the Shaft wall framing. And also used at Doors,
intersections portions. Theses Studs are Light weight members. Sections made to suit to fix
Shaftwall Core boards.
Thickness : 0.55 mm
Size: : 64 & 100
Length : 3000mm & Customized Length
UNITED DEFLECTION J RUNNER ( Head Fixing )
These Runners are used in Shaftwall framing as a head track fixed below the Roof slab. It
has a wide flange, which provide friction fit for the studs & Slip joint allow any movements
& deflection.
Thickness : 0.80 mm
Size: : 64 & 100
Length : 3000mm
Standards Comply to ASTM C 645 & ASTM C 653
UNITED J RUNNER ( Base Fixing )
These Runners are used in Shaftwall framing as a base track fixed on the floor slab. And
Studs will be fixed in this & fastren.
Thickness : 0.80 mm
Size: : 64 & 100
Length : 3000mm
www.ugc.com.sa 52
Pre-Qualification
UNiTED SYSTEM
UNITED DRYWALL METAL PROFILES & SPECIFICATIONS
STEEL SPECIFICATIONS
Our Metal Sections are manufactured using hot dipped zinc coated steel - Z180 & Z275
UNITED FLAT STRAPS
Used in framing applications as wall bracing which provides significant resistance to lateral
loads & to Backup the Board Joints
Thickness : 0.80 mm
Width: : 70 mm
Length : 3000mm & Customized Length
UNITED MAIN CHANNEL
Channel sections are Primary members of Concealed Ceiling System. The main channels are
suspended from soffit by using C-Clamps, Channel Hangers or with the wire Hangers. With
reference to its primary function, these sections are called as carrying Channel.
Thickness : 0.55, 0.60, 0.80, 0.90 & 1.5 mm
Size: : 12 x 38 x 12 mm
Length : 3000mm
Standards Comply to ASTM C 645 & ASTM C 653
UNITED FURRING CHANNEL
Furring Channel sections are Secondary members of Concealed Ceiling System. The Furring
channels flanges are connected to main channel by means of Wafer Head Screws and the
web used to fix the boards.
Thickness : 0.55, 0.60, 0.80 & 0.90 mm
Size: : 70 X 34 X 22 X 12 mm
Length : 3000mm
Standards Comply to ASTM C 645 & ASTM C 653
UNITED WALL ANGLE
L Shaped wall angles sections are used in Concealed Ceiling System as a perimeter
Member. Where the ceiling ends up with the wall, the wall angles will be used in the ceiling
perimeter to fix the boards.
Thickness : 0.55 & 0.60 mm
Size: : 25 X 25 mm
Length : 3000mm
www.ugc.com.sa 53
Pre-Qualification
UNiTED SYSTEM
UNITED DRYWALL ACCESSORIES & SPECIFICATIONS
UMI C CLAMPS
The C clamps are made in C Shape with GI Steel Strips, slightly bigger
than main channel dimensions to accommodate inside. These strong
bracket will hold the main channel for suspended ceilings of limited
loads by the means of 6 mm threaded rod.
www.ugc.com.sa 54
Pre-Qualification
UNiTED SYSTEM
UNITED DRYWALL ACCESSORIES & SPECIFICATIONS
UMI JOINTING COMPOUND
UMI All Purpose Ready Mix / Non asbestos Joint Compound is
composed of vinyl binders & other Ingredients that give superior
performance. MI Vinyl based formulations give excellent slip, bond and
easy workability.
GLASSWOOL INSULATION
Glass wool is an insulation material made from fibers of glass arranged
using a binder & Resins into a texture similar to wool Due to its
Resilience, it recover to its nominal thickness after removal of a normal
compressive Load.
ROCKWOOL INSULATION
Rockwool insulation is made from rocks and minerals. Rockwool
insulation also called stone wool insulation, mineral wool insulation.
Due to its excellent ability to prevent sound and heat. Rockwool
insulation is widely used in Residential commercial & Hospital building.
SEALANTS
UMI Recommended Sealants are based on the performance
requirements (Acoustic & Fire). It seals the Joints and service
penetrations with in the Partitions.
www.ugc.com.sa 55
Pre-Qualification
UNiTED SYSTEM
UL – CERTIFICATE OF COMPLIANCE
www.ugc.com.sa 56
Pre-Qualification
UNiTED SYSTEM
UL TEST REFERENCE – ONLINE CERTIFICATION FROM UL WEBSITE ( Page 1/4 )
www.ugc.com.sa 57
Pre-Qualification
UNiTED SYSTEM
UL TEST REFERENCE – ONLINE CERTIFICATION FROM UL WEBSITE ( Page 2/4 )
www.ugc.com.sa 58
Pre-Qualification
UNiTED SYSTEM
UL TEST REFERENCE – ONLINE CERTIFICATION FROM UL WEBSITE ( Page 3/4 )
www.ugc.com.sa 59
Pre-Qualification
UNiTED SYSTEM
UL TEST REFERENCE – ONLINE CERTIFICATION FROM UL WEBSITE ( Page 4/4 )
www.ugc.com.sa 60
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 61
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 62
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 63
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 64
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 65
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 66
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 67
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 68
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 69
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 70
Pre-Qualification
UNiTED SYSTEM
www.ugc.com.sa 71
Pre-Qualification
UNiTED SYSTEM
UNITED PROJECT LIST
• Princess Nora Bint Abdulaziz University – Riyadh
• Dammam University
• Najran University
• Al-Qassim University
www.ugc.com.sa 72
Pre-Qualification
UNiTED SYSTEM
• The ministry of social affairs- Project Management
www.ugc.com.sa 73
Pre-Qualification
UNiTED SYSTEM
Reach us:
Technical Department:
United Mining Industries – Head Office
Safa Plaza , Office # 560 A , Prince Majid Street –Jeddah
P.O. Box 127398 Jeddah 21352 KSA
) +966 2 6774164 * +966 2 6776316 +966 582017093 / +966 505756129
Email: m.sulthan@ugc.com.sa
www.ugc.com.sa 74