You are on page 1of 74

UNiTED SYSTEM

UNiTED SYSTEM SOLUTIONS


PRE-QUALIFICATION

1
Pre-Qualification

UNiTED SYSTEM

Index
 United Mining Industries

 Company Profile

 Environment Friendly

 Legal Documents

 United System – Solution

 United System Components

 Test Reports & Certificates

 Gypsum Board Leed Documents

 Draft Warranty

 List of Projects

www.ugc.com.sa 2
Pre-Qualification

UNiTED SYSTEM

What is UMI ?
United Mining Industries is a joint-Venture of three major companies in
construction and Building Materials Industry in GCC which are Al Muhaidip, AL
Mojel and Al Rashed. UMI aims to enhance the quality of Gypsum Products in local
and regional market and provide efficient & Economical solutions for the shortage
in housing locally & regionally. Having raw material, low energy cost and being
located in the middle of the region help to provide building and housing sectors
with un-costly high quality Gypsum & Cement Board Products in short notice.

Beside the raw material quarries, the manufacturing facility in Yanbu-KSA built
over an area of 114,000 m² to include Head office, gypsum Powder Plant, Gypsum
Board Plant, Ware House and facility buildings, with capacity of production of 34
million m² and can reach up to 50 millions m².

“ WE CARE BETTER WORLD, SUSTAINABLE DEVELOPMENT


AND STANDARD LIVING ”

www.ugc.com.sa 3
Pre-Qualification

UNiTED SYSTEM

UMI - HISTORY & MISSION


UMI (United Mining Industries Ltd.) Fiber Cement Board and Plasterboard
manufacturing company based in Saudi Arabian that produces fiber cement and
plasterboard and related accessories products for Domestic and Export Marketing.
UMI is a joint venture company of three major Groups in Construction and
Building Materials Industry in GCC which are Al Muhaidib, Al Mojel and Al Rashed.
Initially producing Gypsum Powder from our own quarry in Yanbu, KSA diversified
into Plasterboards, Joint Compound and Fiber Cement Board.

UMI’s mission to enhance the quality of Fiber Cement Board products in local and
regional market to provide efficient, eco-friendly and economical solutions. Having
locally procured major raw materials (excluding Fiber Pulp), low energy cost and
being located in the middle of the region helps us to provide excellent Product to
help sustain Green Building Solutions. Our aim is to save environment and protect
our ecological atmosphere. We use GREEN materials to produce and FCB is
recyclable and degenerate material. UNICEM Fiber Cement Boards are
manufactured to meet requirements of ISO 8336:2009 and ASTM C1186 (2012).

www.ugc.com.sa 4
Pre-Qualification

UNiTED SYSTEM

A TRUSTED LEADERSHIP
UMI is a leading company in manufacturing excellent gypsum board products and
delivering unmatched services to achieve ultimate customer satisfaction. A unique,
professional commitment to the highest level of customer service; a strong belief
in teamwork; modern production facilities with advanced technology and state-of-
the-art manufacturing equipment create a consistent quality product and a
company that surpasses the industry .UMI commitment to quality insures a
dynamic and financially strong corporation that excels at changing the lifestyles of
people.

OUR VALUES
Integrity Mutual Trust

Innovation Teamwork

AMAZING FEATURES & GREAT OUTCOMES

 Water saving  Design flexibility


 Energy saving  Fast installation
 Environmental friendly  Lightweight of wall
 Sustainable site development  Cost efficient
 Lower weight ceiling  Renovation work
 Standard applications  Cost efficient materials
 Durability  Nice decorative finishes
 Easy to repair  Better performance

www.ugc.com.sa 5
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 6
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 7
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 8
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 9
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 10
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 11
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 12
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 13
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 14
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 15
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 16
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 17
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 18
Pre-Qualification

UNiTED SYSTEM

Our
systems
RANGE

www.ugc.com.sa 19
Pre-Qualification

UNiTED SYSTEM
UNITED DRYWALL
A drywall is a Quick and simple
construction with high-quality & high
performance lightweight interior
wall system consisting of a GI steel frame
encased with gypsum plasterboards on either
side attached with self-drilling drywall screws.
The joints are then taped and finished
with gypsum jointing compounds. There are
many types depending on the activity and the
place where it will be installed.

HOW WILL DRYWALL SYSTEMS HELP MY PROJECT ?


VERSATILE - Practical solutions for every application

FIRE SAFE - Up to 180 minutes fire resistance (integrity and insulation).

GREAT ACOUSTICS - Up to STC 73dB sound insulation, excellent sound Isolation

LIGHTWEIGHT - Easy and less costly to transport, saves money on foundations.

SAFE - Less site storage, meaning safer on-site working

COST EFFECTIVE - Cut project time and cost

TRASPORTATION - 50% reduction in deliveries to site, compared with masonry

FAST AND SIMPLE TO CONSTRUCT - Quick to build using engineered components;


easier project scheduling

DURABLE - High levels of impact resistance to meet and surpass BS 5234 Severe Duty
rating.
SUSTAINABILITY Our gypsum plasterboards are 100% recyclable into new
plasterboard. Installation reduces site water consumption, compared to traditional
brick and block.

www.ugc.com.sa 20
Pre-Qualification

UNiTED SYSTEM

SYSTEM RANGE DRYWALL PARTITION SYSTEM SERIES


• UDS1 – United Drywall Single Layer System
• UDS2 – United Drywall Double Layer System
• UDS3 – United Drywall Triple Layer System
• UDSTS – United Drywall Twin Stud System
 UDSTH - United Drywall - Chase wall System
 UDSTS - United Drywall - Staggered System
• UDSLF – United Drywall Lining System - Furring
• UDSLS – United Drywall Lining System - Stud
SPECIAL DRYWALL PARTITION SYSTEM SERIES
• UGSW – United Drywall Shaftwall System
• UGSB – United Drywall Burglar Partition System
• UGSC – United Drywall Cinema Wall System
• UGSDX – United Drywall X-Ray Room Partition System

CONCEALED CEILING SYSTEM SERIES


 UGCF – United Ceiling with Furring & Main Channel
 UGCS – United Ceiling with Stud & Track
• UGCR – United Regular Ceiling System
• UGCM – United Moisture Resistant Ceiling System
• UGCC – United Cement Board Ceiling System
UNiTED

SPECIAL CONCEALED CEILING SYSTEM SERIES


• UGSCF – United Fire Rated Ceiling System
• UGSCA – United Acoustic Ceiling System
• UGSCC – United Cement Board Ceiling System

GRID CEILING SYSTEM SERIES


• UGGR – United Regular Ceiling Grid System
• UGGM – United Moisture Resistant Ceiling Grid System
• UGGC – United Cement Board Ceiling Grid System

www.ugc.com.sa 21
Pre-Qualification

UNiTED SYSTEM
DRYWALL SYSTEMS DESIGNED TO MEET PROJECT REQUIREMENTS
There are many types solutions offered by United Systems depending on the activity and the
place where it will be installed. Based on the projects requirement complying with Standards.

 Fire Resistant walls & ceilings


 Acoustic Performance Walls & Ceilings
 Impact Resistant Walls
 X-Ray’s Protection Walls
 Moisture Resistant Area Walls
High
 High Walls
Walls
 Aesthetic Walls

STANDARDS COMPLY
PRODUCTS SPECIFICATIONS
ASTM C 1396/ C 1396M: Standard Specification for Gypsum Board

ASTM A 653 / A 653M: Standard Specification for Steel Sheet Coating

ASTM C 645: Standard Specification for Non-structural Steel Framing Members

PRODUCTS TESTING
ASTM C 473: Standard Test Methods for Physical Testing of Gypsum Panel Products

ASTM E 84: Standard Test Method for Surface Burning Characteristics of Building Materials

SYSTEM TESTING
ASTM E 119: Standard Test Methods for Fire Tests of Building Construction and Materials

ASTM E 90: Standard Test Method for Laboratory Measurement of Airborne Sound
Transmission Loss of Building Partitions and Elements

SYSTEM INSTALLATION
ASTM C 754: Standard Specification for Installation of Steel Framing Members

ASTM C 840: Standard Specification for Application and Finishing of Gypsum Board

www.ugc.com.sa 22
Wet Area Ceiling Solution Dry & Wet Area Walls Solution
– Non Performance (MR) – Fire Rated (MRFW)

www.ugc.com.sa
Dry/Wet Area Walls Wet Area Walls Solution
Solution – Sound Rated (MR)
– Non Performance
Wet Area Shaft Walls
Dry Area Walls Solution
Solution – Fire Rated
– Fire Rated (FW)
(MRFW)

Dry Area Ceiling Solution


– Non Performance (RG)

External Wall Cladding


- Fire Rated with Gypsum
& FCB Combination Wall

23
UNITED DRYWALL & CEILING SOLUTIONS
UNiTED SYSTEM
Pre-Qualification
Pre-Qualification

UNiTED SYSTEM
UGD1 – UNITED DRYWALL SINGLE LAYER SYSTEM

United Track as Recommended


Insulation as Recommended
Lateral Bracing as Recommended
United Stud as Recommended

United Track as Recommended

Fire Sealant as Recommended

System Fire Rating Acoustic Rating Area


RG 12.5 - 43 dB Dry Area
RG 15 - 44 dB Dry Area
MR/MMR 12.5 - 44 dB Dry & Moisture Area
MR/MMR 15 - 45 dB Dry & Moisture Area
FR 12.5 45 min’s 46 dB Dry Area
FR 15 60 min’s 48 dB Dry Area
FMR 12.5 45 min’s 46 dB Dry & Moisture Area
FMR 15 60 min’s 48 dB Dry & Moisture Area
Hard 12.5 45 min’s 46 dB Dry Area
Hard 15 60 min’s 48 dB Dry Area
Note:
* Based on the performance requirement, the plasterboard needs to be selected – Regular for
general applications; MR for Humidity area application; FW for enhanced fire resistance & for better
acoustic; Hard Board for enhanced Impact resistance etc..
* Stud spacing and metal thickness will be determined by the partition height, deflection limit and
lateral pressure. Min. recommended metal thickness is 0.55mm for fire rated partitions.

www.ugc.com.sa 24
Pre-Qualification

UNiTED SYSTEM
UGD2 – UNITED DRYWALL DOUBLE LAYER SYSTEM

United Track as Recommended


Insulation as Recommended
Lateral Bracing as Recommended
United Stud as Recommended

United Track as Recommended

Fire Sealant as Recommended

System Fire Rating Acoustic Rating Area


RG 12.5 60 min’s 50 dB Dry Area
RG 15 60 min’s 52 dB Dry Area
MR/MMR 12.5 60 min’s 51 dB Dry & Moisture Area
MR/MMR 15 60 min’s 53 dB Dry & Moisture Area
FR 12.5 120 min’s 54 dB Dry Area
FR 15 120 min’s 57 dB Dry Area
FMR 12.5 120 min’s 54 dB Dry & Moisture Area
FMR 15 120 min’s 57 dB Dry & Moisture Area
Hard 12.5 120 min’s 54 dB Dry Area
Hard 15 120 min’s 57 dB Dry Area

Note:
* Based on the performance requirement, the plasterboard needs to be selected – Regular for
general applications; MR for Humidity area application; FW for enhanced fire resistance & for better
acoustic; Hard Board for enhanced Impact resistance etc..
* Stud spacing and metal thickness will be determined by the partition height, deflection limit and
lateral pressure. Min. recommended metal thickness is 0.55mm for fire rated partitions.

www.ugc.com.sa 25
Pre-Qualification

UNiTED SYSTEM
UGDTS – UNITED DRYWALL TWIN STUD SYSTEM – CHASE WALL

United Track as Recommended


Insulation as Recommended
Lateral Bracing
United Twin Framing Stud
Braced
United Track as Recommended

Fire Sealant as Recommended

System Fire Rating Acoustic Rating Area


RG 12.5 60 min’s 52 dB Dry Area
RG 15 60 min’s 55 dB Dry Area
MR 12.5 60 min’s 52 dB Dry & Moisture Area
MR 15 60 min’s 55 dB Dry & Moisture Area
FR 12.5 120 min’s 53 dB Dry Area
FR 15 120 min’s 59 dB Dry Area
FMR 12.5 120 min’s 56 dB Dry & Moisture Area
FMR 15 120 min’s 59 dB Dry & Moisture Area
Hard 12.5 120 min’s 57 dB Dry Area
Hard 15 120 min’s 60 dB Dry Area

Note:
* Based on the performance requirement, the plasterboard needs to be selected – Regular for
general applications; MR for Humidity area application; FW for enhanced fire resistance & for better
acoustic; Hard Board for enhanced Impact resistance etc..
* Stud spacing and metal thickness will be determined by the partition height, deflection limit and
lateral pressure. Min. recommended metal thickness is 0.55mm for fire rated partitions.

www.ugc.com.sa 26
Pre-Qualification

UNiTED SYSTEM
UGDTS – UNITED DRYWALL TWIN STUD SYSTEM

United Track as Recommended


Insulation as Recommended
Lateral Bracing
United Twin Framing Stud as
Recommended
United Track as Recommended

Fire Sealant as Recommended

System Fire Rating Acoustic Rating Area

FR 12.5 150 min’s 70 dB Dry Area


FR 15 180min’s 74 dB Dry Area

FMR 12.5 150 min’s 70 dB Dry & Moisture Area

FMR 15 180 min’s 74 dB Dry & Moisture Area

Hard 12.5 150 min’s 70 dB Dry Area

Hard 15 180 min’s 74 dB Dry Area

Note:
• comprises of multiple layers of gypsum boards on Outer Side of Twin UC structure having parallel
row of tracks and studs. The parallel rows of studs are braced with V Brace or The same Framing
Profile or with the Gypsum Boards , at defined horizontal heights for various acoustic performance
requirements. Filling each stud cavity with acoustic insulation, will enhance acoustical Rating of the
system
• Based on the performance requirement, the plasterboard needs to be selected – Regular for
general applications; Moisture Resistant for Humidity & Tile Baking area application; Fire Resistant
& Hard Boards for enhanced fire Resistance & for better acoustic, Hard - for enhanced Impact
Resistance etc.
• Depends on The wall height & Wall width the Gi Framing will be deigned. Some of walls will have
Acoustic V-Brace when the Project requires High Walls

www.ugc.com.sa 27
Pre-Qualification

UNiTED SYSTEM
UGSW – UNITED SHAFTWALL SYSTEM

UMI Shaft Core Board

UMI CH Stud
Insulation

UMI Fire Resistant board


2 layers 15 mm thk

UNiTED J-Runner
Track

System Fire Rating Acoustic Rating Area

1 x 25 Core + 1 x FR 15 60 min’s 45 dB Dry Area

1 x 25 Core + 2 x FR 15 120 min’s 49 dB Dry Area

1 x 25 Core + 1 x FMR 15 60 min’s 45 dB Dry & Moisture Area

1 x 25 Core + 2 x FMR 15 120 min’s 49 dB Dry & Moisture Area

1 x 25 Core + 1 x FMR 15 60 min’s 45 dB Dry & Moisture Area

1 x 25 Core + 2 x FMR 15 120 min’s 49 dB Dry & Moisture Area

Note:
• Ideal for elevator shafts since the walls can be constructed from one side, leaving the shaft free of
scaffolding. This allows elevator equipment to be installed simultaneously. Shaft Wall Systems provide
superior safety and performance for an important building component such as Elevator, MEP Shafts,
stairwells, air return shafts and horizontal membranes
• Incase of Crowd or High impact area replace the 15 FMR with Hard boards

www.ugc.com.sa 28
Pre-Qualification

UNiTED SYSTEM
UGSDX – UNITED GYPSUM X-RAY ROOM PARTITION SYSTEM

United Track as Recommended


Insulation as Recommended

Bracing as Recommended
United Stud as Recommended
United X-Ray Board as
Recommended

United Sealant as
Recommended

Performances:
• Fire rating 120 Minutes ( max. )
• Acoustic Isolation – 55 dB ( max. )

Note:

• United X-Ray room Drywall Comprises of double layer partition, with single layer of 3mm

Lead Laminated ( X-Ray ) board fixed up to the height of X-ray’s Source passing. The X-

ray board consists of 3mm lead sheet laminated on a special gypsum board. Lead strips

of 3mm thick x 40mm width is glue fixed on the metal studs along the flanges facing the

X-ray source before installing the boards to stop the rays from the board joints.

www.ugc.com.sa 29
Pre-Qualification

UNiTED SYSTEM
UDLF – UNITED DEPENDENT WALL LINING SYSTEM

United Dependent Liner System Uses metal Profiles (


Furring channel or C- studs ) fixed direct to the wall
with anchoring or with the adjustment of Brackets to
maintain the gap between wall & liner to provide the
access for the MEP Services. Once the MEP work
finished then the appropriate Boards will be fixed on
the profiles accessible face.

Application:
Wet Area Wall cladding
Decorative wall cladding

United Furring Channel

Furring Channel

Fisher with
Screw
United MR Board
or UNICEM FCB

United L Angle
Wall Angle

www.ugc.com.sa 30
Pre-Qualification

UNiTED SYSTEM
UDLS – UNITED IN-DEPENDENT WALL LINING SYSTEM

The lining provides fire resistance and acoustic


upgrades to structural steel sections clad with
lightweight metal sheeting, and can also
be used in within new or existing
masonry walls to increase sound insulation and
meet stringent thermal performance
requirements
United Independent Liner System Uses C-
studs & U Tracks fixed between the floor & Roof
Slab. There won’t be any contact between the
Liner Wall & the Block work or any other
substances. Once the framing done , MEP work
will be done if any required & Insulation fixed in
the stud cavity ( if required ). After that
appropriate boards will be selected based on
the area of use and fixed on the stud.

UNITED Board
UNITED Framing - Stud

UNITED Framing - Track

www.ugc.com.sa 31
Pre-Qualification

UNiTED SYSTEM
UGCF – UNITED DRY AREA CEILING SYSTEM WITH FURRING & MAIN CHANNEL

United Suspension United suspension Hangers @


Hanger with Drop In 1200mm ctcs max. Screw fastened &
Anchor to the concrete Clamp to Main Channel
slab

1 Layers 12.5mm thick


United Regular Gypsum United Furring Channel 70 x
board fixed to Furring 35 @ 600mm ctcs max.
Channel. United Main Channel Fixed with
C Clamp with Nut & Bolt

Framing Structural Members Centers


Suspension Centre's Main Channel Centre's Furring Channel Centre's
1200mm max. 1200mm max. 600mm max.

Note:
• Metal Profiles – Size, Thickness & Centers may differ based on the Project Requirement
• Sealant usage based on the performance requirement
• Suspension Height Based on the Project Requirement
• No additional Loads are considered in framing Design

Furring Fixing Details Furring Fixing Details Furring & Wall Angle
Connection Details

www.ugc.com.sa 32
Pre-Qualification

UNiTED SYSTEM
UGCF – UNITED WET AREA CEILING SYSTEM WITH FURRING & MAIN CHANNEL

United Suspension United suspension Hangers @


Hanger with Drop In 1200mm ctcs max. Screw fastened &
Anchor to the concrete Clamp to Main Channel
slab

1 Layers 12.5mm thick


United Moisture Gypsum United Furring Channel 70 x
board fixed to Furring 35 @ 600mm ctcs max.
Channel. United Main Channel Fixed with
C Clamp with Nut & Bolt

Framing Structural Members Centers


Suspension Centre's Main Channel Centre's Furring Channel Centre's
1200mm max. 1200mm max. 600mm max.

Note:
• Metal Profiles – Size, Thickness & Centers may differ based on the Project Requirement
• Sealant usage based on the performance requirement
• Suspension Height Based on the Project Requirement
• No additional Loads are considered in framing Design

Furring Fixing Details Furring Fixing Details Furring & Wall Angle
Connection Details
33
www.ugc.com.sa
Pre-Qualification

UNiTED SYSTEM
UGCF – UNITED WET AREA CEILING SYSTEM WITH FURRING & MAIN CHANNEL

United Suspension United suspension Hangers @


Hanger with Drop In 1000mm ctcs max. Screw fastened &
Anchor to the concrete Clamp to Main Channel
slab

1 Layers UniCEM Fibre


Cement Board fixed to United Furring Channel 70 x
Furring Channel. 35 @ 600mm ctcs max.
United Main Channel Fixed with
C Clamp with Nut & Bolt

Framing Structural Members Centers


Suspension Centre's Main Channel Centre's Furring Channel Centre's
1000mm max. 1200mm max. 600mm max.

Note:
• Metal Profiles – Size, Thickness & Centers may differ based on the Project Requirement
• Sealant usage based on the performance requirement
• Suspension Height Based on the Project Requirement
• No additional Loads are considered in framing Design

Furring Fixing Details Furring Fixing Details Furring & Wall Angle
Connection Details
34
www.ugc.com.sa
Pre-Qualification

UNiTED SYSTEM
UGGR – UNITED GCT / FCT CEILING GRID SYSTEM

Main Runner

Cross Tee Short Cross Tee

Suspension Short Cross Tee

Framing Structural Members Centers


Main Tee Centre’s Cross tee Centre's Short tee Centre's
1200mm max. 600mm max. 600mm max.

System Main Components Connection:


T Grid Ceiling Solution:

• Gypsum Tiles with PVC lamination


• Cement Board Tiles with PVC Lamination
• Cement Tiles without PVC Lamination
• Cement Board Tiles with Textured
Sizes:

• 595x595,
• 603x603,
• 1200 x 600

www.ugc.com.sa 35
Pre-Qualification

UNiTED SYSTEM
UGCF – UNITED FIRE RATED CEILING SYSTEM

United Main
Channel 38 x 12/12
United
X 1.5mm @ 900mm
Recommended
ctcs max.
50mm thick 2 layer 15mm thk
Rockwool Insulation United Fire Resistant
40 kg/m3 Gypsum Board fixed
to Furring Channel.
United Wall
Angle 25 x 25 x
0.60mm fixed
@ 600mm ctc
max.

United Furring United Suspension


Channel 70 x 35 / United Furring Channel Hanger M6 Threaded
0.60mm @ Screw fastened to the Rod with Drop in
400mm ctcs max. main channel using Anchor to the
M4.2X13 wafer head concrete slab @
screw 900mm ctc

Note:
• Metal Profiles – Size, Thickness & Centers may
differ based on the Project Requirement
• Acoustic Sealant usage based on the
performance requirement
• Suspension Height Based on the Project
Requirement
• Additional loading details on the Ceiling must be
informed prior to ceiling design
• Penetrations or any cutouts in the ceiling may
effect the performance rating

www.ugc.com.sa 36
Pre-Qualification

UNiTED SYSTEM
UGCF – UNITED CINEMA CEILING SYSTEM WITH PHOENIC U HANGERS

United Suspension United Main Channel Fixed


Hanger with Drop In with Phoenic U Hanger
Anchor to the concrete with rubber
slab
United suspension
Hangers @ 1000mm ctcs
United Furring Channel
max. Screw fastened to
Screw fastened to the main
Main Channel
channel using M4.2X13
wafer head screw

3 layer 15mm thk


United FireResistant
plasterboard fixed to
Furring Channel.

United Furring Channel 70


United Main Channel 60 x
x 35 / 0.70mm @ 600mm
12/12 X 1.2mm @
ctcs max.
1000mm ctcs max.

Note:
• Metal Profiles – Size, Thickness & Centers may
differ based on the Project Requirement
• Acoustic Sealant usage based on the
performance requirement
• Suspension Height Based on the Project
Requirement
• Additional loading details on the Ceiling must be
informed prior to ceiling design
• Penetrations or any cutouts in the ceiling may
effect the performance rating

www.ugc.com.sa 37
Pre-Qualification

UNiTED SYSTEM
UDCS – UNITED DRYWALL CINEMA SYSTEMS

Note:
• comprises of multiple layers of gypsum boards on Outer Side of Twin UC structure having
parallel row of tracks and studs. The parallel rows of studs are braced with V Brace or The
same Framing Profile or with the Gypsum Boards , at defined horizontal heights for
various acoustic performance requirements. Filling each stud cavity with acoustic
insulation, will enhance acoustical Rating of the system
• Based on the performance requirement, the plasterboard needs to be selected – Regular
for general applications; Moisture Resistant for Humidity & Tile Baking area application;
Fire Resistant & Tuff Boards for enhanced fire Resistance & for better acoustic, Tuff - for
enhanced Impact Resistance etc.
• Depends on The wall height & Wall width the Gi Framing will be deigned. Some of walls
will have Acoustic V-Brace when the Project requires High Walls

www.ugc.com.sa 38
Pre-Qualification

UNiTED SYSTEM
UNITED DRYWALL & CEILING SOLUTIONS
UNITED PRODUCTS & SYSTEMS CERTIFICATION

by by by

In Progress

www.ugc.com.sa 39
Pre-Qualification

UNiTED SYSTEM

RANGE

www.ugc.com.sa 40
Pre-Qualification

UNiTED SYSTEM

UNITED MINING INDUSTRIES PRODUCT RANGE


• UMI offers, different types of Gypsum & Cement Boards & Drywall & Ceiling
• Accessories based on the Clients & Project Requirements
UNITED PREMIUM GYPSUM BOARDS RANGE
• Regular Gypsum Boards
• Fire Resistant Gypsum Boards
• Moisture Resistant Gypsum Boards
• Mold & moisture Resistant Gypsum Boards
• Fire & Moisture Resistant Gypsum Boards
• Hard (Impact Resistant) Gypsum Boards
UNITED CEMENT BOARDS RANGE
• Fibre Cement Boards
• Fibre Cement – Liner Boards – Grade 1
• Fibre Cement – HD Liner Boards – Grade 2
UNITED CEILING TILE RANGE
• Gypsum Ceiling Tiles – with PVC Laminations
• Fibre Cement Ceiling Tiles – with PVC Laminations
• Fibre Cement Ceiling Tiles – without PVC Laminations
• Fibre Cement Ceiling Tiles – with Textured
UNITED METAL PROFILE & ACCESSORIES RANGE
• Metal Profiles – Related to Drywall Systems
• Metal Profiles – Related to Wall Liner Systems
• Metal Profiles – Related to Shaftwall Systems
• Metal Profiles – Related to Cinema Systems
• Metal Profiles – Related to Concealed Ceiling Systems
• Metal Profiles – Related to Grid Ceiling Systems

www.ugc.com.sa 41
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 42
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 43
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 44
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 45
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 46
Pre-Qualification

UNiTED SYSTEM
UNITED PREMIUM GYPSUM BOARDS RANGE & SPECIFICATIONS
UMI offers, different types of Gypsum ( Premium & Regular ) Boards for different types of
Drywall & Ceiling application based on the site conditions.
 Regular Gypsum Boards
 Fire Resistant Gypsum Boards
 Moisture Resistant Gypsum Boards
 Mold & moisture Resistant Gypsum Boards
 Fire & Moisture Resistant Gypsum Boards
 Tuff ( Impact Resistant ) Gypsum Boards

UMI Gypsum Boards are manufactured as per ASTM & EN Standards and comply with
ASTM & EN Specifications & Physical Properties requirement.
UNITED REGULAR GYPSUM BOARD
United Regular Gypsum Boards are produced from high purity natural gypsum core to offer its
consistent properties and Mechanical strength to the boards. The core is encased in dense natural-
finish paper liners.
Thickness : 8, 9, 10, 12, 12.5, 15, 16 & 18 mm
Edges : Taper Edge, Square, Bevel Edge
Width : 900, 1200, 1218 mm
Length : 2400mm ( Also customized sizes based on requirement )
Standards Comply to ASTM C1396/ C1396M & EN 520 Type A
UNITED FIRE RESISTANT GYPSUM BOARD
United Fire Resistant Gypsum Boards are produced from high purity natural gypsum core to offer its
consistent properties and Mechanical strength. And additional of glass fibres and the special
additives used to improve the cohesive properties and fire integrity properties providing greater
fire resistance. The core is encased in dense natural-finish paper liners. .
Thickness : 8, 9, 10, 12, 12.5, 15, 16 & 18 mm
Edges : Taper Edge, Square, Bevel Edge
Width : 900, 1200, 1218 mm
Length : 2400mm ( Also customized sizes based on requirement )
Standards Comply to ASTM C 1396/ C1396M Type X; EN 520 Type D, I & F

www.ugc.com.sa 47
Pre-Qualification

UNiTED SYSTEM
UNITED PREMIUM GYPSUM BOARDS RANGE & SPECIFICATIONS
UNITED MOISTURE RESISTANT GYPSUM BOARD
United Moisture Resistant Gypsum Boards are produced from high purity natural gypsum core to
offer its consistent properties and Mechanical strength. And additional of special additives like
water repellent agents are used to improve the consistent properties Regular with Moisture
Resisting properties. The core is encased in dense natural-finish papers..
Thickness : 8, 9, 10, 12, 12.5, 15, 16 & 18 mm
Edges : Taper Edge, Square, Bevel Edge
Width : 900, 1200, 1218 mm
Length : 2400mm ( Also customized sizes based on requirement )
Standards Comply to ASTM C1396/ C1396M & EN 520 Type A & H
UNITED MOLD & MOISTURE RESISTANT GYPSUM BOARD
United Fire Resistant Gypsum Boards are produced from high purity natural gypsum core to offer its
consistent properties and Mechanical strength. And additional of glass fibres and the special
additives used to improve the cohesive properties and fire integrity properties providing greater
fire resistance. The core is encased in dense natural-finish paper liners. .
Thickness : 8, 9, 10, 12, 12.5, 15, 16 & 18 mm
Edges : Taper Edge, Square, Bevel Edge
Width : 900, 1200, 1218 mm
Length : 2400mm ( Also customized sizes based on requirement )
Standards Comply to ASTM C1396/ C1396M & EN 520 Type A & H
UNITED FIRE & MOISTURE RESISTANT GYPSUM BOARD
United Fire & Moisture Resistant Gypsum Boards are produced from high purity natural gypsum
core to offer its consistent properties and Mechanical strength. And additional of glass fibres and
the special additives used to improve the cohesive properties and Fire integrity & Moisture
Resisting properties providing greater fire resistance. The core is encased in dense natural-finish
paper liners.
Thickness : 8, 9, 10, 12, 12.5, 15, 16 & 18 mm
Edges : Taper Edge, Square, Bevel Edge
Width : 900, 1200, 1218 mm
Length : 2400mm ( Also customized sizes based on requirement )
Standards Comply to ASTM C1396/ C1396M Type X; EN 520 Type D, I , H & F

www.ugc.com.sa 48
Pre-Qualification

UNiTED SYSTEM
UNITED PREMIUM GYPSUM BOARDS RANGE & SPECIFICATIONS
UNITED SHAFT CORE ( FMR ) GYPSUM BOARD
United Fire & Moisture Resistant Gypsum Boards are produced from high purity natural gypsum
core to offer its consistent properties and Mechanical strength. And additional of glass fibres and
the special additives used to improve the cohesive properties and Fire integrity & Moisture
Resisting properties providing greater fire resistance. The core is encased in dense natural-finish
paper liners.
Thickness : 25 mm
Edges : Taper Edge, Square, Bevel Edge
Width : 600 mm
Length : 1800 to 3600mm
Standards Comply to ASTM C1396/ C1396M Type X; EN 520 Type D, I , H & F
UNITED HARD GYPSUM BOARD
United Hard Gypsum Boards are produced from high purity natural gypsum core to offer
better resist surface abrasion and indentation. By incorporating additional core
reinforcement and enhanced facings ( with denser paper ) that provide greater resistance
to more significant impact. And additional of glass fibres and the special additives used to
improve the cohesive properties and Fire integrity & Moisture Resisting properties
providing greater fire resistance. The core is encased in dense natural-finish paper liners.
Thickness : 12.5, 15, 16 & 18 mm

Edges : Taper Edge, Square, Bevel Edge


Width : 1200, 1218 mm
Length : 2400mm ( Also customized sizes based on requirement )

Standards Comply to ASTM C1396/ C1396M Type X; EN 520 Type D, I , R & F

www.ugc.com.sa 49
Pre-Qualification

UNiTED SYSTEM
UNITED CEMENT BOARDS RANGE & SPECIFICATIONS
UNITED FIBRE CEMENT BOARD ( FCB )
UNiCEM United fibre Cement Boards are made from a mix of cement, Cellulose fibre and fire resistant fillers
on Hatschek machines. The products having excellent resistance again. UNiCEM United fibre Cement Boards
are produce as per ASTM C 1186 Type “A” (Direct Exposure to Sun, Rain and Snow) Standard Specification for
Exterior Grade Flat fibre Cement Boards.
Standards Comply to ASTM C1186 – Grade I, II & III
GRADES AVAILABLE:
•UNICEM FCB - GRADE 1
•UNICEM LINER HD - GRADE 2

Product Thickness ‘mm’ Width ‘mm’ Length ’mm’

UNICEM Square
6, 9, 12, 15, 16 & 18 1200 & 1220 2400 & 2440
Edge

UNICEM LINER HD 2400, 2440, 2600,


9, 12, 15 & 20 1200 & 1220
Recess & SQ Edge & 2700

UNICEM Plank
7.5 & 8 150 & 200 2400 & 3000
Wood Texture
Textured Board
9 & 12 1200 & 1220 1200 & 2400
For Cladding
UNICEM Ceiling 600, 610, 1200 &
5&6 600 & 610
PVC & Textured 1220
UNICEM SWP 2400, 2700, 3000
5&6 600 & 610
Boards SQ Edge & 3600

Thermal Conductivity:
UNICEM United Fibre Cement Boards are test for 0.21 W/mK for 6mm thick board.
Effect of Temperature:
UNICEM United Fibre Cement Boards are not recommended to be stored in temperature
above 500 for prolonged period.
Effect of condensation:
UNICEM United Fibre Cement Boards are vapour permeable. If vapour condenses on the
surface, the board will retain its strength.

www.ugc.com.sa 50
Pre-Qualification

UNiTED SYSTEM
UNITED DRYWALL METAL PROFILES & SPECIFICATIONS
STEEL SPECIFICATIONS
Our Metal Sections are manufactured using hot dipped zinc coated steel - Z180 & Z275
UNITED STUDS
Studs are the Primary sections used in the Drywall & Lining Systems. Studs used in Vertical
condition at appropriate centers to match the structural stability based on the design. Studs
are fixed between the Base & Head Track, Screwed only with the Base track & Friction fit at
the Head Track.
Thickness : 0.55, 0.60, 0.80, 0.90, 1.20 & 1.50 mm
Width: : 50, 64, 70, 75, 90, 100, 125 & 150 mm
Flange : 34/36 mm
Length : 3000mm & Customized Length
Standards Comply to ASTM C 645 & ASTM C 653
UNITED DEFLECTION TRACK
Deflection Tracks are used at the top as Head Tracks. Which helps to allow the partitions,
when needs a movement (up, down) within the structure at the head of a partition.
Deflection Tracks Secured with appropriate anchors at Concrete Slab & Hold the studs in
position and it helps in aligning the Boards.
Thickness : 0.80, & 0.90 mm
Width: : 50, 64, 70, 75, 90, 100, 125 & 150 mm
Flange : 50 mm
Length : 3000mm
Standards Comply to ASTM C 645 & ASTM C 653
UNITED TRACK
Tracks are the Secondary sections used in the Drywall & Lining Systems. Tracks used in
Horizontal condition & Secured with appropriate anchors at Floor Slab & Soffit. Tracks Hold
the studs in position and it helps in aligning the Boards.
Thickness : 0.55, 0.60, 0.80, 0.90, 1.20 & 1.50 mm
Width: : 50, 64, 70, 75, 90, 100, 125 & 150 mm
Flange : 30 mm
Length : 3000mm
Standards Comply to ASTM C 645 & ASTM C 653

www.ugc.com.sa 51
Pre-Qualification

UNiTED SYSTEM
UNITED SHAFTWALL PROFILES & SPECIFICATIONS
UNITED SHAFTWALL ( CH ) STUDS
United Ch Studs are specially designed for the Shaftwall systems sed in framing applications
as wall bracing which provides significant resistance to lateral loads & to Backup the Board
Joints
Thickness : 0.55 & 0.80 mm
Width: : 64 & 100
Length : 3000mm & Customized Length
UNITED E STUD
E Studs are the Starter & End member for the Shaft wall framing. And also used at Doors,
intersections portions. Theses Studs are Light weight members. Sections made to suit to fix
Shaftwall Core boards.
Thickness : 0.55 mm
Size: : 64 & 100
Length : 3000mm & Customized Length
UNITED DEFLECTION J RUNNER ( Head Fixing )
These Runners are used in Shaftwall framing as a head track fixed below the Roof slab. It
has a wide flange, which provide friction fit for the studs & Slip joint allow any movements
& deflection.
Thickness : 0.80 mm
Size: : 64 & 100
Length : 3000mm
Standards Comply to ASTM C 645 & ASTM C 653
UNITED J RUNNER ( Base Fixing )
These Runners are used in Shaftwall framing as a base track fixed on the floor slab. And
Studs will be fixed in this & fastren.
Thickness : 0.80 mm
Size: : 64 & 100
Length : 3000mm

www.ugc.com.sa 52
Pre-Qualification

UNiTED SYSTEM
UNITED DRYWALL METAL PROFILES & SPECIFICATIONS
STEEL SPECIFICATIONS
Our Metal Sections are manufactured using hot dipped zinc coated steel - Z180 & Z275
UNITED FLAT STRAPS
Used in framing applications as wall bracing which provides significant resistance to lateral
loads & to Backup the Board Joints
Thickness : 0.80 mm
Width: : 70 mm
Length : 3000mm & Customized Length
UNITED MAIN CHANNEL
Channel sections are Primary members of Concealed Ceiling System. The main channels are
suspended from soffit by using C-Clamps, Channel Hangers or with the wire Hangers. With
reference to its primary function, these sections are called as carrying Channel.
Thickness : 0.55, 0.60, 0.80, 0.90 & 1.5 mm
Size: : 12 x 38 x 12 mm
Length : 3000mm
Standards Comply to ASTM C 645 & ASTM C 653
UNITED FURRING CHANNEL
Furring Channel sections are Secondary members of Concealed Ceiling System. The Furring
channels flanges are connected to main channel by means of Wafer Head Screws and the
web used to fix the boards.
Thickness : 0.55, 0.60, 0.80 & 0.90 mm
Size: : 70 X 34 X 22 X 12 mm
Length : 3000mm
Standards Comply to ASTM C 645 & ASTM C 653
UNITED WALL ANGLE
L Shaped wall angles sections are used in Concealed Ceiling System as a perimeter
Member. Where the ceiling ends up with the wall, the wall angles will be used in the ceiling
perimeter to fix the boards.
Thickness : 0.55 & 0.60 mm
Size: : 25 X 25 mm
Length : 3000mm

www.ugc.com.sa 53
Pre-Qualification

UNiTED SYSTEM
UNITED DRYWALL ACCESSORIES & SPECIFICATIONS
UMI C CLAMPS
The C clamps are made in C Shape with GI Steel Strips, slightly bigger
than main channel dimensions to accommodate inside. These strong
bracket will hold the main channel for suspended ceilings of limited
loads by the means of 6 mm threaded rod.

UMI THREADED ROD


Threaded Rods with Nut & Washer are used as a suspension member of
Concealed Ceiling System, Which holds the Main channel with use of C
Clamps

UMI SELF THREADED SCREWS


Heavy duty self tapping bugle head screw with head diameter of 8 mm,
are self tapping fasteners for multiple layer drywalls, insulation and
accessory mountings on steel structures up to 0.8 mm thickness.

UMI SELF DRILLING SCREWS


Heavy duty drill point bugle head screw with head diameter of 8 mm,
are self drilling fasteners for multiple layer drywalls, insulation and
accessory mountings on steel structures up to 3.0 mm thickness.

UMI LAMINATING SCREWS


Laminating Screws are fasteners for directly laminating gypsum boards
together when used in more than 1 layers as well as fastening
accessories to multiple gypsum board layer linings. .

www.ugc.com.sa 54
Pre-Qualification

UNiTED SYSTEM
UNITED DRYWALL ACCESSORIES & SPECIFICATIONS
UMI JOINTING COMPOUND
UMI All Purpose Ready Mix / Non asbestos Joint Compound is
composed of vinyl binders & other Ingredients that give superior
performance. MI Vinyl based formulations give excellent slip, bond and
easy workability.

UMI JOINTING TAPE


UMI Tape is a Fibre Glass Drywall Tape, Which is made with unique
Cross-Fibreglass Construction to provide greater Strength to Drywall
Joints. Also can be used in fixing damages, small cracks or Holes.

GLASSWOOL INSULATION
Glass wool is an insulation material made from fibers of glass arranged
using a binder & Resins into a texture similar to wool Due to its
Resilience, it recover to its nominal thickness after removal of a normal
compressive Load.

ROCKWOOL INSULATION
Rockwool insulation is made from rocks and minerals. Rockwool
insulation also called stone wool insulation, mineral wool insulation.
Due to its excellent ability to prevent sound and heat. Rockwool
insulation is widely used in Residential commercial & Hospital building.

SEALANTS
UMI Recommended Sealants are based on the performance
requirements (Acoustic & Fire). It seals the Joints and service
penetrations with in the Partitions.

www.ugc.com.sa 55
Pre-Qualification

UNiTED SYSTEM
UL – CERTIFICATE OF COMPLIANCE

www.ugc.com.sa 56
Pre-Qualification

UNiTED SYSTEM
UL TEST REFERENCE – ONLINE CERTIFICATION FROM UL WEBSITE ( Page 1/4 )

www.ugc.com.sa 57
Pre-Qualification

UNiTED SYSTEM
UL TEST REFERENCE – ONLINE CERTIFICATION FROM UL WEBSITE ( Page 2/4 )

www.ugc.com.sa 58
Pre-Qualification

UNiTED SYSTEM
UL TEST REFERENCE – ONLINE CERTIFICATION FROM UL WEBSITE ( Page 3/4 )

www.ugc.com.sa 59
Pre-Qualification

UNiTED SYSTEM
UL TEST REFERENCE – ONLINE CERTIFICATION FROM UL WEBSITE ( Page 4/4 )

www.ugc.com.sa 60
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 61
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 62
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 63
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 64
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 65
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 66
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 67
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 68
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 69
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 70
Pre-Qualification

UNiTED SYSTEM

www.ugc.com.sa 71
Pre-Qualification

UNiTED SYSTEM
UNITED PROJECT LIST
• Princess Nora Bint Abdulaziz University – Riyadh

• Central Security Project – Ministry of interiors affairs

• King Faisal University – Ahsaa

• Granada Commercial and Residential Center – Riyadh

• King Saud bin abdulaziz University

• Ewa’a emergency center in Shomaisi- Mecca

• Capital Market Authority (CMA) – Riyadh

• Taibah University –Medina

• King Khaled University –Abha

• Dammam University

• King Abdulaziz University

• Prince Sultan University – Riyadh

• King Faisal Hospital – Mecca

• Jabal Omar Project – Mecca

• King Abdullah Financial Center- Riyadh

• Najran University

• Imam Muhammad Bin Saud Islamic University

• Ministry of Health – Projects and Engineering Affairs

• Ministry of education – school projects

• The strategic project for the ministry of interior affairs installations

• King Faisal University – The hospital building

• Al-Qassim University

www.ugc.com.sa 72
Pre-Qualification

UNiTED SYSTEM
• The ministry of social affairs- Project Management

• Haramain train project from Mecca – Jeddah – Medina

• Omran Hospital- Ahsa province

• Social security office – Basrah the Obeida

• Villas Project – Royal Commission in Yanbu and Jubail

• King Abdulaziz University – Jeddah – the main building

• Agricultural Development fund project – Al Kharj

• Housing units for the diplomatic

• Fairmont Resort – Riyadh

• Development projects center – Care Center – Riyadh

• King Faisal University – The University Hospital

• King Abdullah Financial Center – samba tower – Riyadh

• Development Projects – Ministry of Interior Affairs – Cap

• King Abdullah University of science and technology – Thule

• Medical city – King Abdulaziz University – Riyadh

• Nama Main Building

• Education House for Girls – Riyadh

• Umm Al-Qura University – Mecca

• Umran Hospital – Al Ahsa

• Faculty Housing Project – Jouf

• Technical College – Bassamtah

• General Authority for food & drug administration

• Queen Alia International Airport – Amman

www.ugc.com.sa 73
Pre-Qualification

UNiTED SYSTEM

Reach us:
Technical Department:
United Mining Industries – Head Office
Safa Plaza , Office # 560 A , Prince Majid Street –Jeddah
P.O. Box 127398 Jeddah 21352 KSA
) +966 2 6774164 * +966 2 6776316 +966 582017093 / +966 505756129
Email: m.sulthan@ugc.com.sa

Sales & Marketing - KSA


United Mining Industries – Head Office
Safa Plaza , Office # 560 A , Prince Majid Street –Jeddah
P.O. Box 127398 Jeddah 21352 KSA
) + 966 2 6774164 Ext: 103 6 +966 2 6776316 +966 561628999

GCC, Jordon & Aman


Office 7 – Ghudaf Centre 2
Building – Gardens Str
) + 962 6 5560053 6 +962 6 5660854 +962 79 9666366 & + 966 536 000710
Email: saad@ugc.com.sa

www.ugc.com.sa 74

You might also like