EG3000

Electronic Engine Governor Controller


An electronic controller designed for precise speed control of diesel, gas, and
gasoline (petrol) engines. Installed together with a magnetic pickup (MPU)
and connected to a governor actuator forms the engine governor system.
Works with Built-in, External and PT Pumps type actuators. Adjustable Smoke
Limiting & Idle Speed settings.
Features
 DIP switch settings allow a wide range of MPU/flywheel frequencies
 15 Amp max. current output to drive actuator
 Suitable for all types of diesel, gas and petrol engines
 High sensitivity and stability at low frequency variations
 Isochronous mode for individual (island) operation
 Droop mode for parallel operation with PLC control (non-isochronous)
 Connections for remote speed potentiometer
 Input for Isochronous Load Sharing (ILS) from an external load controller
Specifications
Operating Voltage 10 to 30 Vdc Temp. Stability Between -40°C to +85°C better than +/-0.5%
Output Current From 0.5 Amp to 15 Amp Remote Speed Adjustment Range (2 mode)
Frequency Range 600 to 9500 Hz (MPU signal) Adjustable range +/-5% with 5k ohms potentiometer
Idle Speed Frequency Adjustable from 30 to 85% of normal Ramp Time 3 to 20 secs. (Adjustable)
Speed Band +/-0.25% at steady state
Environment DIP Switch Description
Operating Temperature -40°C to +85°C SW1 ON 600 to 1200 Hz
Storage Temperature -40°C to +85°C SW2 ON 1200 to 2500 Hz
Relative Humidity Max. 95% SW3 ON 2500 to 5000 Hz
Vibration 3.0Gs @ 100-2K Hz SW4 ON 5000 to 9500 Hz
SW5 ON For PT Pump type actuator
Governor Controls
DROOP Droop rate adjustment RAMP-TIME Soft start adjustment
GAIN Actuator output gain adjustment SPEED Speed adjustment
INT. Engine stability adjustment IDLE Idle speed adjustment
DIF Differential adjustment

Mechanical Specifications Physical Specifications


Dimension 147.0 (L) x 114.0 (W) x 50.0 (H) mm
147.0 42.0
135.0 Weight 690 g +/- 2%
4.3

DROOP DIF. INT. GAIN RAMP


SW

POWER : DC12/24V
114.0
102.0

SW1-ON 600~1200HZ
SW2-ON 1200~2500HZ
SW3-ON 2500~5000HZ
SW4-ON 5000~9500HZ
SW5-ON PT-PUMP

IDLE SPEED
REMOTE
SPEED POT RUN SPEED
+ IDLE ILS
ACT
1 2 3 4 5 6 7 8 9 10 MPU 11

5.5
50.0
Unit : mm

KUTAI ELECTRONICS INDUSTRY CO., LTD.


TEL : +886-7-8121771 FAX : +886-7-8121775 Website : www.kutai.com.tw
Headquarters : No.3, Lane 201, Chien Fu St., Chyan Jenn Dist., Kaohsiung 80664, TAIWAN