You are on page 1of 4
GREDE I-If BEAMS I-If OPIS ELEMENTA Grede | i if (1 filante) su horizontalni noseéi elementi od rednapregnutog betona, konstantne visine, na koje se oslanjaju Sekundarni element krova (npr. korube ii reznjaée), krovni nosadi vipa Opera’, a koriste se i 2a horizontalne grede kranskistaza. Odvodenje atmosferske vode se reSava odvodom kroz poseban otvor koji se formira spajanjem dve susedne grede. Oslanjanje krajeva grede | If v8i se preko neoprenskih le2ista. Spo} dgrede | stuba se vrSi uz pomoé armaturnih Sipki koje su prievrSéene u Stubu i prilikom montaze proviaée se kroz otvore koji se nalaze na krajevima greda If, Otvor! se potom zalivaju cementnim malterom. REDE TIPAL Standardne tirine 8=50-G0cm visine H=80-120em, karakterite ravougaoni (pun) popreéni presek na mestu osionca. Grede Sirine B560-70cm visie H=150cm su “T popretnog preseka ma mestu REDE TIPA If Standardne Sirine 8=50-60 em i kkonstantnog popretnog preseka, Visine H=80-90-100em su karakteristiéne évrstoée N/mm? materijal material ‘Characterized strength N/mm beton- concrete Me = 55 keablovi- cables fox 1860 Eellk B5O0- steel 9500 ove = 400 == MARTINI, DESCRIPTION OF ELEMENTS Beams | and IF (filaments) are horizontal supporting elements of pre: stressed concrete, they have constant height and the secondary roof el- ‘ements rely on them (e.g. TT slabs or purlins). On them can also rely fof cals named “Opera”, as well the horizontal crane ‘als. Drainage of storm water drain Is solved through a special opening that Is formed by connecting two near beams. Reliance of the beam endings 1s dane through the neoprene bearings. Connection between beams and pillars is done through reinforcing bars Which are attached to the pillars, and are pulled trough the openings at the ends of the beams during montage. The openings then meet with ‘Cement mortar. BEAMS TYPO | The standard width of B = $0-6Ocm and height of H=80-120cm. These types are characterized by rectangular (ull) cross-section atthe point of support. The beams width of 8-60-70cm and height of H=150cm are ‘characterized by'T cross-section atthe point of support BEAMS TYPO IF he standard width of 8=50-6Oem and height of H=80-90-100em are characterized by the constant cross-section, 27 sole clone | grede (max optereéenje)-| beams (max lone) _ aig vp ana 10000 HOA BS iim: cu enon em arti = es «06020 m5 sea a0 soso 7 Em co «20 75 F coe so 32 0 5 j S so 5010 5 % sooo - 120 i = so 201100 a 50 3210 825 zone 70 70 14 1350 wee bbb ee a de is ie a 21 92 33 za 2s 150 60 6014 275, so aaa peat maja aearincemen OOS ee papers armenian Sian If grede ~ filanti (max optereéenje)-\/ beams ~ filant! (max loae) ot Tes same ap fume a i. 80 jie Bis yee a so 16 SS «026 ee Sas 100 27 = “=e 60 26 i ~ aoe Yougs Thais wags 3s vss tees Geass tees as adie isd ‘opterecene {kg/m =istalnospovemena) kg/m x alm) 30150 Srrasterosno astojanlelamedu areca tr sor60 tad aan = lens ts0iso Shee stedne everson: 30i60 tr 0/s0 SS inieofee 29 Taig promod I grede-\ beams iy ay hy = tad tad amu fe Pe) ver200-100-— 400 1150-Lmax 25 m. -T] hed hed I grede ~ flanti-\' beams ~ lant I La sole clone ____—SSSSEE= reeks ups einermuce poled Ten ps ie eral 2 thr dha MARTIN GRAD te ores er nem, ee ere an ea Pee opp ot MART NA

You might also like