C-FIX 1.90.0.

0
Database version
2020.9.11.10.1
Date
03/11/2020

Graha DSN, Jakarta Timur

Client PT. BERSAMA BANGUN PERSADA


PT. Spectra Utama Makmur
Bp. Niko Jl. Raya Kelapa Nias GN 11- 12; Kel.
Kelepa Gading Barat,Kec. Kelapa
Gading
Jakarta Utara 14240
Phone: (021) 2245 9009
Fax: (021) 2245 7985
info@mrsafetygroup.com
www.mrsafetygroup.com

Comment
Chemical Anchor Suspended Glass - Pemasangan Angkur Stout ( h : 5 m ), menggunakan 2 FTRS M10 x 130 mm + FIS
EM Plus kedalamam 90 mm

Design Specifications
Anchor
Anchor system fischer Injection system FIS V
Injection resin FIS V 360 S
Fixing element Threaded rod FIS A M 12 x 140, zinc plated steel,
Property Class 5.8
Calculated anchorage 90 mm
depth
Design Data Specification by manufacturer

Geometry / Loads / Scale units


mm, kN, kNm

Value of design actions (including

partial safety factor for the load) Static

Not drawn to scale

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 1
C-FIX 1.90.0.0
Database version
2020.9.11.10.1
Date
03/11/2020

Graha DSN, Jakarta Timur

Input data

Design method Design method ENSO Bonded


Base material Normal weight concrete, Customized, Test specimen:
Cylinder 150 x 300 mm, Compressive strength = 35.0 N/mm²
Concrete condition Non-cracked, dry hole
Temperature range 24 °C long term temperature, 40 °C short term temperature
Reinforcement Normal or no reinforcement. No edge reinforcement
Drilling method hammer drilling
Installation type Push-through installation
Annular gap Annular gap filled
Type of loading Static or quasi-static
Base plate location Base plate flush installed on base material
Base plate geometry 100 mm x 150 mm x 10 mm
Profile type None

Design actions *⁾
# NSd VSd,x VSd,y MSd,x MSd,y MT,Sd Type of loading
kN kN kN kNm kNm kNm
1 6.46 0.00 -9.80 0.00 0.00 0.00 Static or quasi-static

*⁾ The required partial safety factors for actions are included

Resulting anchor forces


Tensile action Shear Action Shear Action x Shear Action y
Anchor no. kN kN kN kN
1 3.23 4.90 0.00 -4.90
2 3.23 4.90 0.00 -4.90

max. concrete compressive strain : 0.00 ‰


max. concrete compressive stress : 0.0 N/mm²
Resulting tensile actions : 6.46 kN , X/Y position ( 0 / 0 )
Resulting compression actions : 0.00 kN , X/Y position ( 0 / 0 )

Resistance to tension loads

Proof Action Capacity Utilisation βN


kN kN %
Steel failure * 3.23 28.67 11.3
Combined pull-out and concrete cone failure 6.46 41.48 15.6
Concrete cone failure 6.46 52.85 12.2

* Most unfavourable anchor

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 2
C-FIX 1.90.0.0
Database version
2020.9.11.10.1
Date
03/11/2020

Graha DSN, Jakarta Timur

Steel failure

( NRd,s )

NRk,s γMs NRd,s NSd βN,s


kN kN kN %
43.00 1.50 28.67 3.23 11.3

βN,s
Anchor no. % Group N° Decisive Beta
1 11.3 1 βN,s;1
2 11.3 2 βN,s;2

Combined pull-out and concrete cone failure

( NRd,p )

Eq. (5.2)

Eq. (5.2a)

Eq. (7.14a)

Eq. (7.15)

Eq. (7.16)

Eq. (5.2e)

Eq. (5.2f)

Eq. (5.2g)

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 3
C-FIX 1.90.0.0
Database version
2020.9.11.10.1
Date
03/11/2020

Graha DSN, Jakarta Timur

Eq. (5.2h)

Eq. (5.2i)

NRk,p γMp NRd,p NSd βN,p


kN kN kN %
62.22 1.50 41.48 6.46 15.6

βN,p
Anchor no. % Group N° Decisive Beta
1, 2 15.6 1 βN,p;1

Concrete cone failure

( NRd,c )

Eq. (5.3)

Eq. (5.3a)

Eq. (5.3c)

Eq. (5.3d)

Eq. (5.3e)

NRk,c γMc NRd,c NSd βN,c


kN kN kN %
79.27 1.50 52.85 6.46 12.2

βN,c
Anchor no. % Group N° Decisive Beta
1, 2 12.2 1 βN,c;1

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 4
C-FIX 1.90.0.0
Database version
2020.9.11.10.1
Date
03/11/2020

Graha DSN, Jakarta Timur

Resistance to shear loads

Proof Action Capacity Utilisation βV


kN kN %
Steel failure without lever arm * 4.90 16.80 29.2
Concrete pry-out failure 9.80 82.95 11.8

* Most unfavourable anchor

Steel failure without lever arm

( VRd,s )

VRk,s γMs VRd,s VSd βVs


kN kN kN %
21.00 1.25 16.80 4.90 29.2

βVs
Anchor no. % Group N° Decisive Beta
1 29.2 1 βVs;1
2 29.2 2 βVs;2

Concrete pry-out failure

( VRd,cp )

Eq. (5.7)

Eq. (5.2)

Eq. (5.2a)

Eq. (7.14a)

Eq. (7.15)

Eq. (7.16)

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 5
C-FIX 1.90.0.0
Database version
2020.9.11.10.1
Date
03/11/2020

Graha DSN, Jakarta Timur

Eq. (5.2e)

Eq. (5.2f)

Eq. (5.2g)

Eq. (5.2h)

Eq. (5.2i)

VRk,cp γMcp VRd,cp VSd βV,cp


kN kN kN %
124.43 1.50 82.95 9.80 11.8

βV,cp
Anchor no. % Group N° Decisive Beta
1, 2 11.8 1 βV,cp;1

Utilization of tension and shear loads

Tension loads Utilisation βN Shear Loads Utilisation βV


% %
Steel failure * 11.3 Steel failure without lever arm * 29.2
Combined pull-out and concrete cone failure 15.6 Concrete pry-out failure 11.8
Concrete cone failure 12.2
* Most unfavourable anchor

Resistance to combined tensile and shear loads


Utilisation steel
Eq. (5.9a)

Eq. (5.9b)

Eq. (5.10)

Utilisation concrete Proof successful


Eq. (5.9a)

Eq. (5.9b)

Eq. (5.10)

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 6
C-FIX 1.90.0.0
Database version
2020.9.11.10.1
Date
03/11/2020

Graha DSN, Jakarta Timur

Information concerning the anchor plate


Base plate details
Plate thickness specified by user without proof t = 10 mm

Profile type None

Technical remarks
All data and information in the software is based on fischer products and common engineering knowledge. Please
check all the proof results against local valid standards and approvals.
As fischer is not the design office, the attached is no guarantee for incorrect input or assumptions. Any
recommendations have to be approved by the building-authority or project engineer. Results are valid only for
anchor system calculated in the attached. If any part of the system is changed, it will invalidate this report and new
calculations would be required.
The transmission of the anchor loads to the supports of the concrete member shall be shown for the ultimate limit state and
the serviceability limit state; for this purpose, the normal verifications shall be carried out under due consideration of the
actions introduced by the anchors. For these verifications the additional provisions given in the current design method shall
be taken into account.
As a pre-condition the anchor plate is assumed to be flat when subjected to the actions. Therefore, the plate must be
sufficiently stiff. The C-Fix anchor plate design is based on a proof of stresses and does not allow a statement about
the stiffness of the plate. The proof of the necessary stiffness is not carried out by C-Fix.

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 7
C-FIX 1.90.0.0
Database version
2020.9.11.10.1
Date
03/11/2020

Graha DSN, Jakarta Timur

Installation data
Anchor
Anchor system fischer Injection system FIS V
Injection resin FIS V 360 S (other cartridge sizes Art.-No. 68435
available)
Fixing element Threaded rod FIS A M 12 x 140, Art.-No. 90283
zinc plated steel, Property Class 5.8

Accessories FIS MR Plus Art.-No. 545853


Dispenser FIS DM S Art.-No. 511118
Blow-out pump ABG big Art.-No. 89300
Cleaning brush BS 14 Art.-No. 78180
SDS Plus II 14/100/160 Art.-No. 531815
or alternatively
FHD 14/250/380 Art.-No. 546598
Hammer drilling with or without
suction
Alternative cartdriges FIS V 410 C Art.-No. 77529
The shown cartdriges are
alternative to the highlighted
one above with the same approval
number.

Installation details
Thread diameter M 12
Drill hole diameter d0 = 14 mm
Drill hole depth h2 = 100 mm
Calculated anchorage hef = 90 mm
depth
Installation depth hnom = 90 mm
Drilling method hammer drilling
Drill hole cleaning 4 times blowing,
4 times brushing,
4 times blowing
required activities according the
given instruction in the approval
No borehole cleaning required in
case of using a hollow drill bit, e.g.
fischer FHD.
Installation type Push-through installation
Annular gap Annular gap filled
Maximum torque Tinst,max = 40.0 Nm
Socket size 19 mm
Base plate thickness t = 10 mm
Total fixing thickness tfix = 10 mm
Tfix,max
Volume of resin per drill 10 ml/5 scale divisions
hole

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 8
C-FIX 1.90.0.0
Database version
2020.9.11.10.1
Date
03/11/2020

Graha DSN, Jakarta Timur

Base plate details


Base plate material Not available
Base plate thickness t = 10 mm
Clearance hole in base df=16 mm
plate

Attachment
Profile type None

Anchor coordinates

x y
Anchor no. mm mm
1 0 50
2 0 -50

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in