0
Database version
2020.9.11.10.1
Date
03/11/2020
Comment
Chemical Anchor Suspended Glass - Pemasangan Angkur Stout ( h : 5 m ), menggunakan 2 FTRS M10 x 130 mm + FIS
EM Plus kedalamam 90 mm
Design Specifications
Anchor
Anchor system fischer Injection system FIS V
Injection resin FIS V 360 S
Fixing element Threaded rod FIS A M 12 x 140, zinc plated steel,
Property Class 5.8
Calculated anchorage 90 mm
depth
Design Data Specification by manufacturer
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 1
C-FIX 1.90.0.0
Database version
2020.9.11.10.1
Date
03/11/2020
Input data
Design actions *⁾
# NSd VSd,x VSd,y MSd,x MSd,y MT,Sd Type of loading
kN kN kN kNm kNm kNm
1 6.46 0.00 -9.80 0.00 0.00 0.00 Static or quasi-static
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 2
C-FIX 1.90.0.0
Database version
2020.9.11.10.1
Date
03/11/2020
Steel failure
( NRd,s )
βN,s
Anchor no. % Group N° Decisive Beta
1 11.3 1 βN,s;1
2 11.3 2 βN,s;2
( NRd,p )
Eq. (5.2)
Eq. (5.2a)
Eq. (7.14a)
Eq. (7.15)
Eq. (7.16)
Eq. (5.2e)
Eq. (5.2f)
Eq. (5.2g)
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 3
C-FIX 1.90.0.0
Database version
2020.9.11.10.1
Date
03/11/2020
Eq. (5.2h)
Eq. (5.2i)
βN,p
Anchor no. % Group N° Decisive Beta
1, 2 15.6 1 βN,p;1
( NRd,c )
Eq. (5.3)
Eq. (5.3a)
Eq. (5.3c)
Eq. (5.3d)
Eq. (5.3e)
βN,c
Anchor no. % Group N° Decisive Beta
1, 2 12.2 1 βN,c;1
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 4
C-FIX 1.90.0.0
Database version
2020.9.11.10.1
Date
03/11/2020
( VRd,s )
βVs
Anchor no. % Group N° Decisive Beta
1 29.2 1 βVs;1
2 29.2 2 βVs;2
( VRd,cp )
Eq. (5.7)
Eq. (5.2)
Eq. (5.2a)
Eq. (7.14a)
Eq. (7.15)
Eq. (7.16)
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 5
C-FIX 1.90.0.0
Database version
2020.9.11.10.1
Date
03/11/2020
Eq. (5.2e)
Eq. (5.2f)
Eq. (5.2g)
Eq. (5.2h)
Eq. (5.2i)
βV,cp
Anchor no. % Group N° Decisive Beta
1, 2 11.8 1 βV,cp;1
Eq. (5.9b)
Eq. (5.10)
Eq. (5.9b)
Eq. (5.10)
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 6
C-FIX 1.90.0.0
Database version
2020.9.11.10.1
Date
03/11/2020
Technical remarks
All data and information in the software is based on fischer products and common engineering knowledge. Please
check all the proof results against local valid standards and approvals.
As fischer is not the design office, the attached is no guarantee for incorrect input or assumptions. Any
recommendations have to be approved by the building-authority or project engineer. Results are valid only for
anchor system calculated in the attached. If any part of the system is changed, it will invalidate this report and new
calculations would be required.
The transmission of the anchor loads to the supports of the concrete member shall be shown for the ultimate limit state and
the serviceability limit state; for this purpose, the normal verifications shall be carried out under due consideration of the
actions introduced by the anchors. For these verifications the additional provisions given in the current design method shall
be taken into account.
As a pre-condition the anchor plate is assumed to be flat when subjected to the actions. Therefore, the plate must be
sufficiently stiff. The C-Fix anchor plate design is based on a proof of stresses and does not allow a statement about
the stiffness of the plate. The proof of the necessary stiffness is not carried out by C-Fix.
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 7
C-FIX 1.90.0.0
Database version
2020.9.11.10.1
Date
03/11/2020
Installation data
Anchor
Anchor system fischer Injection system FIS V
Injection resin FIS V 360 S (other cartridge sizes Art.-No. 68435
available)
Fixing element Threaded rod FIS A M 12 x 140, Art.-No. 90283
zinc plated steel, Property Class 5.8
Installation details
Thread diameter M 12
Drill hole diameter d0 = 14 mm
Drill hole depth h2 = 100 mm
Calculated anchorage hef = 90 mm
depth
Installation depth hnom = 90 mm
Drilling method hammer drilling
Drill hole cleaning 4 times blowing,
4 times brushing,
4 times blowing
required activities according the
given instruction in the approval
No borehole cleaning required in
case of using a hollow drill bit, e.g.
fischer FHD.
Installation type Push-through installation
Annular gap Annular gap filled
Maximum torque Tinst,max = 40.0 Nm
Socket size 19 mm
Base plate thickness t = 10 mm
Total fixing thickness tfix = 10 mm
Tfix,max
Volume of resin per drill 10 ml/5 scale divisions
hole
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 8
C-FIX 1.90.0.0
Database version
2020.9.11.10.1
Date
03/11/2020
Attachment
Profile type None
Anchor coordinates
x y
Anchor no. mm mm
1 0 50
2 0 -50
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.
Page 9