ZND090-AMT-Td-0001 Rev.

FAST PLANETS Co LTD.,


ENGINEERING DEPARTMENT
P.0. BOX : 34620
RIYADH - 11478

ANALYSIS / COMPARATIVE STUDY


OF EXISTING
25+4.0m Extended Latticed MONOPOLE TOWER
(LTE Project 2011)

Main Site No.: ZND090


ORIGINAL DESIGN LOAD + EXISTING & PROPOSED LOADING CONDITION
LTE Project 2011 ZND090-AMT-Td-0001 Rev.A

TABLE OF CONTENTS

TITLE PAGE NO.

COVER PAGE 1

TABLE OF CONTENTS 2

INTRODUCTION 3

CONCLUSION 3

TOWER COMPARATIVE STUDY 4

TABLE I - WIND LOAD ON ANTENNA SUPPORT PIPE 6


AND OTHER MOUNTED POLE STRUCTURE

TABLE II - STANDARD 25m SELF-SUPPORT MONOPOLE WIND LOAD 7

TOWER DEFLECTION 8

TOWER INFORMATION 9

ATTACHMENT

ORIGINAL TOWER LOAD DESIGN CALCULATION


TOWER PROFILE

Analyzed by: Checked by: Approved by:

J.B.Vasquez J.A.Hasson A.A.Aleem


Telecom Engineer Structural Engineer Projects Manager

Page 2 of 11
LTE Project 2011 ZND090-AMT-Td-0001 Rev.A

Main Site No. ZND090

INTRODUCTION

Tower load comparative study for main site no. ZND090 was performed to compare
the design load against the actual load to determine its feasibility to support the
existing and the proposed new antenna loading to be used for LTE Project 2011.

Refer to pages 4 to 7 for the detailed comparative study of the tower original design
loading and actual loading. Tower existing loading condition and proposed new
antennas and tower physical condition and other relevant information are tabulated on
pages 9 to 11. For information on tower mast geometry and member sizes, see
attachment.

CONCLUSION

The results show that the tower meet the criteria of 39 m/s (140KPH) basic wind
speed. The original design load of the tower is greater than the present actual load and
it is indicative that there is no increase in antenna loads. Hence, we can conclude that
the tower can safely support the existing and the proposed microwave antenna loading
for LTE Project 2011
.

Page 3 of 11
LTE Project 2011 ZND090-AMT-Td-0001 Rev.A

Comparison between original design loads and actual loads for standard 25.0m Monopole tower

Tower height = 25 m
Gh = 1.690

Original Design Loads

Wind speed = 39 m/s


Design Loads Size Dept Qty, n Elevation Kz Fa Fa*Gh*Kz*n Base Moment
(m) (m) (kN) (kN) (kN-m)
PANEL 900 MHZ GSM 9 25.0 1.299 0.89 17.51 437.64
HP 1.20 DIA MW 2 25.0 1.299 1.39 6.10 152.57
HP 2.40 DIA MW 1 25.0 1.299 5.56 12.21 305.15
Tubular Poles 1 25.0 m high GSM LS N/A 4 1.000 N/A 4 N/A 4 4636.41
Mounted Poles 2 2.0 m high GSM LS N/A 4 1.000 N/A 4 N/A 4 2.86
Cantilevered Lattice 3 4.0 m high GSM LS N/A 4 1.000 N/A 4 N/A 4 137.89
Total Base Moment = 5672.52

1 25.0m high Monopole Tubular Pole

2 2.0 m high Mounted Pole

3 4.0m high Cantileverd Lattice


4 Previously gusted (i.e. KZ and Gh equal to 1.0), see Tables I, II & III

Page 4 of 11
LTE Project 2011 ZND090-AMT-Td-0001 Rev.A
Actual Loads
Wind speed = 35 m/s GH = 1.69
Actual Loads Size Dept Qty, n Elevation Kz Fa Fa*Gh*Kz*n Base Moment
(m) (m) (kN) (kN) (kN-m)
LR 0.20 Ø x 2.0m GSM 1 30 1.3687 0.016 0.04 1.08
PANEL 900 MHZ GSM 3 29 1.3555 0.713 4.90 142.10
HP 0.30 DIA. MW 4 28 1.3420 0.120 1.09 30.48
PANEL 1800 MHZ GSM 1 26 1.3139 0.534 1.19 30.83
HP 0.30 DIA. MW 1 24 1.2842 0.120 0.26 6.25
PANEL 900 MHZ GSM 1 25 1.2992 0.713 1.57 39.14
3G 2100 MHZ GSM 1 25 1.2992 0.538 1.18 29.53
HP 0.30 DIA. MW 1 24 1.2842 0.120 0.26 6.25
HP 0.60 DIA. MW 1 23 1.2687 0.350 0.75 17.26
HP 0.30 DIA. MW 1 23 1.2687 0.120 0.26 5.92
HP 0.30 DIA. MW 2 22.5 1.2607 0.120 0.51 11.51
HP 0.30 DIA. MW 1 23 1.2687 0.120 0.26 5.92
NEW LTE 1 GSM 3 26.00 1.314 0.538 3.58 93.18
Tubular Poles 25.0m high GSM LS N/A 2 1.000 N/A 2 N/A 2 3734.14
Mounted Poles 2.0M high GSM LS N/A 2 1.000 N/A 2 N/A 2 2.26
Cantilevered Lattice 4.0m high GSM LS N/A 2 1.000 N/A 2 N/A 2 111.26
Total Base Moment = 4267.11
% Comparison of original design loads versus actual loads = 0.7522
1
New GSM antenna
2
Previously gusted (i.e. KZ and Gh equal to 1.0), see Tables I & II

Conclusion : Since there is no increase in antenna loads, therefore the tower can safely support the existing plus the proposed new loading.

Page 5 of 11
LTE Project 2011 ZND090-AMT-Td-0001 Rev.A

Table I - Wind load on antenna support pipe and other mounted pole & latticed structures.

Tower ht. = 25 m
Wind speed = 39 m/s
G =
h
1
1.5625 1.00 </=GH</=1.25 Sec.2.3.4.1 of TIA-EIA-222-F

Actual Loads Size Dept Length, l Diameter, d Appurtenance Kz Pressure C CF Force, Fc

(mm) (mm) c/l Elev., (m) qz (kPa) (C<4.40) (kN/m)

LR 20ømmx2.0m GSM 2000 20.0 29.80 1.366 1.274 0.912 1.200 0.048

1
multiplied by 1.25, to compensate for the greater gust response for mounted pole structure (EIA/TIA-222-E, Sec. 2.3.4.4)

Table I - Wind load on antenna support pipe and other mounted pole structures.

Tower ht. = 25 m
Wind speed = 35 m/s
G =
h
1
1.5625 1.00 </=GH</=1.25 Sec.2.3.4.1 of TIA-EIA-222-F

Actual Loads Size Dept Length, l Diameter, dAppurtenance Kz Pressure C CF Force, Fc


(mm) (mm) c/l Elev., (m) qz (kPa) (C<4.40) (kN/m)

LR 20ømmx2.0m GSM 2000 20.0 29.80 1.365 1.025 0.818 1.200 0.038

1
multiplied by 1.25, to compensate for the greater gust response for mounted pole structure (EIA/TIA-222-E, Sec. 2.3.4.4)
LTE Project 2011 ZND090-AMT-Td-0001 Rev.A
Total Base Moment = 1042.59

Page 7 of 11
LTE Project 2011 ZND090-AMT-Td-0001 Rev.A

TABLE II - 25.0M SELF-SUPPORTING MONOPOLE TOWER


Typical tower wind load distribution as per section in normal to the tower face.

H= 25 m Heightof Monopole
V= 39 m/s Basic Design Wind speed for the structure
GH = 1.69 Gust Response of Monopole as per Section 2.3.4.2
of TIA-EIA_222-F

SECTION AG(sq.m.) AR(sq.m.) GH*qZ*AF=qz*G


G zequivalent(m) OTM(kN-m)
H*CF*AR(kNs)
1 9.567 9.854 18456.99 130.95 20.482 2682.12
2 10.719 11.041 17668.57 140.46 11.520 1618.10
3 9.121 9.395 14372.05 97.22 3.458 336.187
Total = 4636.41 kN-m

TABLE II - 25.0M SELF-SUPPORTING MONOPOLE TOWER


Typical tower wind load distribution as per section in normal to the tower face.

H= 25 m Heightof Monopole
V= 35 m/s Basic Design Wind speed for the structure
GH = 1.69 Gust Response of Monopole as per Section 2.3.4.2
of TIA-EIA_222-F

SECTION AG(sq.m.) AR(sq.m.) GH*qZ*AF=qz*G


G zequivalent(m) OTM(kN-m)
H*CF*AR(kNs)
1 9.567 9.854 14865.10 105.47 20.482 2160.24
2 10.719 11.041 14230.11 113.12 11.520 1303.14
3 9.121 9.395 11575.13 78.30 3.458 270.761
Total = 3734.14 kN-m
MT-Td-0001 Rev.A
LTE Project 2011 ZND090-AMT-Td-0001 Rev.A

TOWER DEFLECTION

As per original design loads:

ELEV. 45 m/s WIND SPEED 33 m/s WIND SPEED

(m) DEFLECTION (mm) ROTATION (deg) DEFLECTION (mm) ROTATION (deg) ALLOW. TILT/SWAY (deg)

36.00 79.70 0.24 44.00 0.13 0.50

The above shown tower deflection is based on the original design loads (attached); considering
that the existing + proposed antenna loads are less than the original design loads, thus actual
tower deflection will be lesser than the deflection due to original design loads.

Page 8 of 11
LTE Project 2011 ZND090-AMT-Td-0001 Rev.A

TOWER SITE INFORMATION

The following two tables include existing tower loading, proposed loading, physical
condition of the steel tower and foundation and other relevant information.

Page 9 of 11
LTE Project 2011 ZND090-AMT-Td-0001 Rev.A

Site Survey Report - Tower Antenna Loads


Date: 22/05/2009
Site 306-00-000
ANTENNA LOADING DATA FEEDLINES/ LADDER DATA
No. TYPE SIZE ELEV. AZIM. F/L QTY SIZE TYPE REMARKS
(meter) (meter) (deg.) (mm)

NOTES

ANTENNA DATA:
No. Assign a number to each antenna, starting at top of tower and working down.

TYPE Paraboloid (Dish): S- Solid, G- Grid, HP- High Performance (Flat Shielded), R- with Radome
T.V.- UHF, BC- Broadcast, Y- Yagi, D- Directional (cellular), O- Omnidirectional, P- Paging
Reflectors: CHR- Conical Horn Reflector, FPR- Flat Plate Passive Reflectors.
G.S.M.: A- ALLGON, ADC- ADC Dual Polarized.
MISC.: S/S- Self Supporting Tower, G/T- Guyed Tower, P/M- Pole Mount.

SIZE: Indicate diameter in meters for parabolic (microwave dishes), size for other types.
ELEV. Height above ground in meters (Elevation).
AZIM. Azimuth: Show antenna orientation in degrees or compass reading (N, NE, E,SE, S, etc.).
F/L Indicate antenna mount: Face (F) or leg (L).
REMARKS Existing or proposed new antenna(s) designation.

FEEDLINES/ LADDER DATA COMMENTS


QTY: Quantity.
SIZE: Diameter or size in (mm).
TYPE: W- Waveguide, C- Coax, H- Heliax, L- Ladder.
Page 10 of 11
LTE Project 2011 ZND090-AMT-Td-0001 Rev.A

Site Survey Report - Tower Antenna Loads


Date: 22/05/2009
Site 306-00-000
ANTENNA LOADING DATA FEEDLINES/ LADDER DATA
No. TYPE SIZE ELEV. AZIM. F/L QTY SIZE TYPE REMARKS
(meter) (meter) (deg.) (mm)

NOTES

ANTENNA DATA:
No. Assign a number to each antenna, starting at top of tower and working down.

TYPE Paraboloid (Dish): S- Solid, G- Grid, HP- High Performance (Flat Shielded), R- with Radome
T.V.- UHF, BC- Broadcast, Y- Yagi, D- Directional (cellular), O- Omnidirectional, P- Paging
Reflectors: CHR- Conical Horn Reflector, FPR- Flat Plate Passive Reflectors.
G.S.M.: A- ALLGON, ADC- ADC Dual Polarized.
MISC.: S/S- Self Supporting Tower, G/T- Guyed Tower, P/M- Pole Mount.

SIZE: Indicate diameter in meters for parabolic (microwave dishes), size for other types.
ELEV. Height above ground in meters (Elevation).
AZIM. Azimuth: Show antenna orientation in degrees or compass reading (N, NE, E,SE, S, etc.).
F/L Indicate antenna mount: Face (F) or leg (L).
REMARKS Existing or proposed new antenna(s) designation.

FEEDLINES/ LADDER DATA COMMENTS


QTY: Quantity.
SIZE: Diameter or size in (mm).
TYPE: W- Waveguide, C- Coax, H- Heliax, L- Ladder.

Page 10A of 11
LTE Project 2011 ZND090-AMT-Td-0001 Rev.A

TOWER INSPECTION CHECKLIST

Existing Tower Light x Medium Heavy None


Tower Manufacturer Al Babtain Le Blanc Model 36.0 M

Tower Type Tower Cross-Section Tower Members Tower Base outside width 6.70 m
x Self Supporting Triangular Tubular Angle Solid Rd Anchor Bolt Size 25 dia. mm
Guyed Mast x Rectangular Legs x BasePlate Thickness 4.0 cm
Monopole Diagonals x BasePlate dimensions 40x40 cm
Struts x
Tower Conditions:
Guy Wires Structural
x Good, no visible rust or kinks, straight members Yes No
Average, some surface rust, no other damage x Ladder Exists
Below Average, rusty, needs maintenance x Enclosed Ladder
Poor, severe rust, bent/ missing members, bolts or strands x Painted
Loose or corroded bolts or anchor bolts or Guy Hardware Red/White, No. of bands 7
Sagging Guy wires, Tower Out of Plumbness or Twisted

Foundation Type Condition Cement Grout


Piers x Good, no visible cracks or damage x Good
x Raft Average, edges rough, no cracks, edge wear Fair
Piles Below Average, surface cracks, edge wear Poor, missing
Roof Mount Poor cracks, spalding, deteriorating
Others
x Pedestal Size 70 x 70 cm Guy Anchor Size N/A .
Distance from tower to anchor block N/A
Comments :