You are on page 1of 2

PROJECT : PAGE :

CLIENT : DESIGN BY :
JOB NO. : DATE : REVIEW BY :
Concrete Beam Design, for New or Existing, Based on ACI 318-19

INPUT DATA & DESIGN SUMMARY


CONCRETE STRENGTH f 'c = 4 ksi, (28 MPa)
REBAR STRENGTH MAIN fy = 60 ksi, (414 MPa)
STIRRUP fy = 60 ksi, (414 MPa)
FACTORED BENDING MOMENT Mu = 1000 ft-kips, (1356 kN-m)
FACTORED SHEAR FORCE Vu = 230 kip, (1023 kN), (104.33 Tn)
FACTORED TORSIONAL MOMENT Tu = 36.5 ft-kips, (49 kN-m)
SECTION DIMENSIONS bw = 24 in, (610 mm)
h= 48 in, (1219 mm)
hf = 8 in, (203 mm) THE DESIGN IS ADEQUATE.
b= 88 in, (2235 mm), (ACI 318-19 6.3.2.1 & 9.2.4.4)
COMPRESSION REINFORCEMENT 4 # 7
TENSION REINFORCEMENT 6 # 9
SHEAR REINFORCEMENT 4 legs # 4 @ 12 in, (305 mm), o.c.

ANALYSIS
CHECK FLEXURAL CAPACITY emax = 0.003 0.85 f c'
A s' f s'
(
2 0.85 f C' )
e o  e max or , E c  57 f C , E s  29000ksi
'

Ec Fc
   e   e 2

0.85 f C  2 
' c  c  ,
   for 0  e c  e o Parabolic
fC   e o   e o  

0.85 f C , for e c  e o

'

Asfy
e s E s , for e s  e t

fS
 f , for e s  e t
 y

Cover = 1.5 in, (ACI 318 20.6.1) rprov'd = 0.0055 < rmax = 0.0119 , (ACI 318 9.3.3.1)
d= 45.44 in > rmin = 0.0033 , (ACI 318 9.6.1)
d' = 2.44 in [Satisfactory]
f= 0.90 , (ACI 318-19 21.2) c= 5.39 in, by pure math method
ec,max = 0.0006 Fc = 334.34 kips
es,max = 0.0050 , (ACI 318-19 21.2.2) dc = 1.85 in

fMn = 1185.14 ft-k > Mu [Satisfactory]

CHECK SHEAR CAPACITY


Check section limitation (ACI 22.5.5 & 22.5.1.2) Determine concrete capacity (ACI 22.5.5.1)

V u  10f b wd f
'
V C  2b wd fc
'
c 137.93 kips
230.0 < 517.3 kips [Satisfactory]
f=
where 0.75
(1.9 A 2500r wB) b wd
V C + 144.10 kips ,<== applicable
Check shear reinforcement (ACI 22.5)
 f
0 , for V u  V c where A MIN ( f
'
c , 100 ) 63.25
 2
  50b w V d
 Av   0.75 f 'c b w  fV c B MIN  u , 1.0
 s    MAX  ,  , for  V u  fV c M u 0.871
  Re qD   fy f  2
 y 
 f
V u V c , for fV c  V u
 f df y

 Av 
= 0.716 in2 / ft <  s   0.800 in2 / ft [Satisfactory]
  Pr ovD
Check spacing limits for shear reinforcement (ACI 22.6.9.5)
V u  fV c
Vs   0.00 kips, (ACI 22.5.1.1)
f

 d
, 24) for V s  4b wd
'
 MIN ( f
 2 c
S max, shear  = 22 > S= 12 in
 MIN ( d , 12) for V s  4b wd f
'
[Satisfactory]

 4 c
(cont'd)
CHECK TORSION CAPACITY
Check section limitation (ACI 22.7.7.1)
2
  T u Ph   
2
 Vu where f= 0.75 (ACI 21.2)
  +    f  V C + 8 f 'c 
 2    Ph = 258 in, (perimeter of centerline of outermost closed
 b wd   1.7 Aoh  b
 w
d
 transverse torsional reinforcement.)
Aoh = 1,287 in2 (area enclosed by centerline of the outermost
0.215 < 0.474 [Satisfactory] closed transverse torsional reinforcement.)

Check if torsional reinforcement required (ACI 9.5.4.1)

'  Acp 
2 where be = MIN(h-hf , 4hf) = 32 in, (one side, ACI 9.2.4.4)
Tu f f c  Pcp = 160 in, (outside perimeter of the concrete cross
 P cp  section.)
36.5 < 36.5 ft-k Acp = 1,216 in2 (area enclosed by outside perimeter of
Torsional reinforcement NOT reqD. concrete cross section.)

Check the max factored torque causing cracking (ACI 22.7.3.2)


'  Acp 
2

T u  4f f c 
 P cp 
36.5 < 146.1
Reduction of the torsional moment can occur.

Determine the area of one leg of a closed stirrup (ACI 22.7.6.1)

At  T u  Tu  0.00 in2 / ft < actual = 0.2 [Satisfactory]


s 2f A0 f yv 1.7f A0 h f yv

Determine the corresponding area of longitudinal reinforcement (derived from ACI 22.7.6.1 & 9.6.4.3)

  
25b w  
'
At f 5 Acp f c f
A L  MAX  P h  Ph MAX  At ,  
yv yv
, in2
s f f yL f  s f yv  
0.00
 yL yL  
Determine minimum combined area of longitudinal reinforcement
AL, top = As' +0.5AL = 0.00 in2 < actual [Satisfactory]
AL, bot = As +0.5AL = 5.06 in2 < actual [Satisfactory]

Determine minimum diameter for longitudinal reinforcement (ACI 25.7.1.2)


dbL = MAX(0.042 S, 3/8) = 0.50 in < 0.88 in [Satisfactory]

Determine minimum combined area of stirrups (ACI 9.6.4.2 & 9.7.6.3.3)


(Av+2At) / S = 0.40 in2 / ft > MAX [ 0.75(fc')0.5bw/fyv, 50bw/fyv] = 0.24 in2 / ft
Smax, tor = MIN[(Ph/8, 12) = 12 in [Satisfactory]
SreqD = MIN(Smax,shear , Smax,tor) = 12 in > actual [Satisfactory]