LED DIGITAL DISPLAY


HIGH FUNCTIONALITY
UZU2
PRESSURE SENSORS Series
COMPETENT FUNCTIONALITY WITH YOUR PREFERENCE MODEL FROM
WIDE LINE-UP

m
co
High Repeatability and Clearly Visible LED Display Setting with Easy Key
Resolution at Quick Response with 3 1/2 Digits Operation
Quick response : 2.5ms or less
High resolution : 1/1,000 range
Bright red LED 7-segment display with
3 1/2 digits 10mm .394inch high. The s. Initialization and threshold value setting
are easily attained by the key operation
nt
High repeatability : Within50.2% displayed figures are remarkably with the figure shown on the display.
F.S.51 digit noticeable not only in a dark area, but
ne

Temperature characteristic : Within in a light place.


51% F.S.
The UZU2 senses the pressure level
accurately.
po

Minus sign
om

“1”
appears

Four Output Process Modes Enable Versatile Pressure Level Control Six Pressure Units
ec

Negative (Vacuum) type


Q Hysteresis mode W Window comparator mode
Hysteresis Hysteresis Hysteresis Your customary unit can be selected
ON
in

Comparative Comparative ON from six standards.


output 1 output 1 When the unit is changed, the mea-
OFF OFF
ON Comparative ON sured pressure value and the set val-
l

Comparative
output 2 ues are automatically converted.
on

output 2 OFF
OFF 0 Threshold value 1 Threshold value 2
0 Threshold value 1 Threshold value 2
High vacuum (Negative type) High vacuum (Negative type) The international
High pressure (Positive type) High pressure (Positive type) system of unit (SI)

The common hysteresis of two comparative out- The comparative output keeps the ON state or the InchHg kPa (*1) kgf/cm2
puts can be arbitrarily set. OFF state in between the threshold value 1 and
the threshold value 2 with the default hysteresis.

E Dual output mode R Automatic sensitivity setting mode mmHg psi bar
Hysteresis Hysteresis
: Negative pressure
Comparative ON Comparative ON : Positive pressure
Output 2 OFF output 1 OFF
Comparative ON Comparative ON (*1) : The UZU2M20 and UZU2M22 are assigned
Output 1 output 2 OFF in MPa.
OFF
0 Threshold value 1 Threshold value 2 0 Threshold value 1 Threshold value 2
High vacuum (Negative type) Threshold value 3 High vacuum (Negative type)
High pressure (Positive type) High pressure (Positive type)
As two comparative outputs are acted by the Just a simple simulation of the O.K. level and the
respective threshold values, three-level classifica- N.G. level sets the threshold level automatically.
tion is available such as for Low-Go-High compari- The threshold value 3 can be adjusted with the key
son, stable O.K.-unstable-N.G. evaluation. operation.

269
UZU2 series 0.6.10 11:28 Page 2

APPLICATIONS
Securing chip-component carriage Controlling clamp force Inspecting orientation of glass board
on suction hand Supply pressure is changed in accor- Pressure increases in proportion to
The light weight type does not disturb dance with kinds of workpieces. The tightness of a air gap. By checking for
the movement of the suction hand, UZU2 observes the pressure levels at the indentations of glass boards, the
even it is mounted on the hand. the clamp hand. UZU2 recognizes the orientations of
them. UZU2001

UZU2M02 MODE

UZU2001
E
MOD

DE
MO

IC tray

UZU2001

Vacuum tank
IC
Vacuum pump
Verifying settlement of frame Controlling edge of winding film
High pressure is gained when the With the bifurcated nozzles placed on the both sides of the film, one is for air intak-
frame is exactly seated. ing and the other is for air ejecting with the UZU2, the position of the winding film is
The UZU2 detects a slight pressure acknowledged in right-ward (high pressure), center (middle pressure), or left-ward
change. (low pressure). UZU2M12
UZU2M12

Frame

m
Air MO
DE

MO
DE

co
Test tank
Seats
s.
nt
Air

Analog Voltage Outputs in All A Wide Variety of Models


ne

Models Selectable in mounting style, environmental resistance, and customary manner.


The analog voltage output (1 to 5V) in Standard type/UZU20M0 Flat type/UZU2MM2
po

proportion to the pressure level en-


ables a real-time observation or a multi-
ple-digital-output control.
om

DP

Peak-hold and/or Bottom-hold


2-20

–101
.3k
Pa

OU

Displayable
T1

MO
DE
OU
T2
0-A
DJ
MO
DE

The peak value and/or the bottom value


ec

of the changeable pressure level can Direct piping Mounting on a panel


be displayed. It is useful to notify the Direct mounting on a wall
amplitude range, or the highest or the
in

lowest value before the threshold val- Light weight type/UZU2001


ues are determined. Total weight The UZU2 covers world-wide usage
l

approx. 70g 2.47oz with the Asian type, the North American
Numerical Figure Indication
on

type, and the European type. Each


into Analog Bar Display type provides the customary pressure
Pop-up numerical values are not so unit, the related transistor output, and
readable to catch up with pressure the pressure port.
changes, but the analog bar display The sensor is
helps you read it with ease. mounted on a
suction head of
LED bars reveal the level by every 10%
(F.S. regardless of the pressure unit. ) a chip mounter.

Digital display Analog bar display Pressure unit


European type
The international Output Pressure port
system of unit
(SI)
kgf/cm2 (Positive pressure) NPN and Rc (PT) 1/8 or M5
North Asian mmHg (Negative pressure) analog voltage female thread
American
type North psi (Positive pressure) NPN and
Pa InchHg (Negative pressure) analog voltage NPT 1/8
American
Asian
PNP and
type European bar analog voltage G (PF) 1/8

270
UZU2 series 0.6.10 11:28 Page 3

ORDER GUIDE
Type (Vacuum) Appearance Rated pressure range Model No. Pressure port Comparative output
100kPa –101kPa
Negative
Positive pressure pressure

0 to 1101.3kPa
type
UZU2000
Standard

Asian
type

NPN open-collector
0 to 100.0kPa UZU2010 Rc (PT) 1/8
transistor
1MPa
type

0 to 1.000MPa UZU2020
Light weight

Negative pressure (Vacuum)

Asian

UZU2001 M5 female thread


1101kPa type

NPN open-collector
transistor
0 to 1101.3kPa
European American European American European American
North

UZU2102 NPT 1/8

PNP open-collector
UZU2202 G (PF )1/8
transistor

m
North

NPN open-collector
Flat

100kPa type

UZU2112 NPT 1/8


transistor

co
0 to 100.0kPa
Positive pressure

PNP open-collector
UZU2212 G (PF) 1/8
transistor

s.
North

NPN open-collector
UZU2122
1MPa type

NPT 1/8
transistor
nt
0 to 1.000MPa
PNP open-collector
UZU2222 G (PF) 1/8
ne

transistor
po

OPTION
Panel mounting bracket and
om

Designation Model No. Description Front protective cover

Panel mounting
For mounting on a panel
bracket UZU812 Front protective
ec

(For standard type) (thickness 1 to 3.2mm .039 to .126inch) cover UZU813 –10
1.3
kPa

OU
T1

OU
T2
0-A
DJ
MO
DE

Front protective
For protecting the adjustable front surface
cover UZU813
in

(Use it with the panel mounting bracket.)


(For standard type)
Panel mounting bracket
Sensor mounting UZU812
l

Mounting bracket for standard type


bracket UZU811 Applicable panel
on

(Two M4 screws with washers are attached.) thickness 1 to 3.2mm


(For standard type)
.039 to .126inch

Converts pressure port from female thread


Adaptor bolt UZU814 [Rc (PT) 1/8] to male thread [R (PT) 1/8] Sensor mounting Adaptor bolt
bracket

Adaptor
bolt

Two M426mm .236inch


pan head screws and two
spring washers are
attached.

271
UZU2 series 0.6.10 11:28 Page 4

SPECIFICATIONS
Negative pressure (Vacuum) Positive pressure
Type 1101kPa type 100kPa type 1MPa type
Standard Flat Light weight Standard Flat Standard Flat
Model No.

Asian UZU2000 UZU2001 UZU2010 UZU2020


North American UZU2102 UZU2112 UZU2122
Item European UZU2202 UZU2212 UZU2222
Pressure scale Gauge pressure
Rated pressure range 0 to1101.3kPa 0 to 100.0kPa 0 to 1.000MPa
Setting pressure range 5.1 to1101.3kPa 15.0 to 100.0kPa 10.050 to 1.000MPa
Pressure resistance 490kPa 1.47MPa
Applicable fluid Non-corrosive gas
Selectable units kgf/cm2, bar, psi, mmHg, InchHg kgf/cm2, bar, psi
Supply voltage 12 to 24V DC `10
115 % Ripple P-P 10% or less
Current consumption 50mA or less
<Asian, North American> <European>
NPN open-collector transistor PNP open-collector transistor
Comparative output • Maximum sink current : 100mA • Maximum source current : 100mA
(Comparative output 1, 2 in common) • Applied voltage : 30V DC or less • Applied voltage : 30V DC or less
• Residual voltage : 1V or less (at 100mA sink current) • Residual voltage : 2V or less (at 100mA source current)
0.4V or less (at 16mA sink current)
Utilization category DC-12 or DC-13

m
Output process mode Selectable with key operation either hysteresis mode, window comparator mode, dual output mode, or automatic sensitivity setting mode
Hysteresis 1 digit (2 digits when using psi unit, variable when using hysteresis mode)

co
Repeatability Within50.2% F.S.51digit
Response time 2.5ms or less
Short-circuit protection

Output voltage : 1 to 5V (with rated pressure range)


Incorporated

s. pressure (V)
5
nt
Zero-point : Within 1V55% F.S.
Output

Analog voltage output Span : Within 4V55% F.S.


Linearity : Within51% F.S. 1
ne

High pressure (Positive type)


Output impedance : Approx. 1kΩ
Pressure High vacuum (Negative type)

Display Red LED display 3 1/2 digits (Sampling cycle : 4 times/sec.)


po

Pressure display range 5.1 to1101.3kPa 15.0 to 100.0kPa 10.050 to 1.000MPa


Analog bar display LED-bar step indication by every approx.10% F.S.
Comparative Orange LED (lights up when the comparative output 1 is activated)
om

Operation output 1
indicator Comparative Green LED (lights up when the comparative output 2 is activated)
output 2
Pollution degree 3 (Industrial environment)
ec

Protection Standard • Flat • Light weight types : IP40 (IEC)


Environmental resistance

Ambient temperature 110 to`507C `14 to`1227F (No dew condensation nor icing allowed), Storage : 110 to ` 607C `14 to ` 1407F
in

Ambient humidity 35 to 85%RH, Storage : 35 to 85%RH


EMC Emission : EN50081-2, Immunity : EN50082-2
l

Voltage withstandability 1,000V AC for one min. between all terminals connected and enclosure
on

Insulation resistivity 50MΩ or more at 500V DC Megger between all terminals connected and enclosure
Vibration-proof 10 to 150 Hz frequency, 0.75mm .030inch amplitude, and X, Y, and Z directions each for two hours (unenergized)
Shock-proof 100m/s2 acceleration {approx. 10G}, and X, Y, and Z directions each for three times (unenergized)
Temperature characteristic Within51% F.S. of detection pressure at 207C 687F in 110 to`507C `14 to`1227F temperature range
Asian Standard • Flat type : Rc (PT) 1/8, Light weight type : M5 female thread
Pressure port North American Flat type : NPT 1/8
European Flat type : G (PF) 1/8
Front case : ABS, Rear case : PPS (containing glass fiber), Display surface : Acrylic,
Material
Pressure port attachment : Zinc alloy die-casted [Light weight type : POM (containing glass fiber)]
Cable Oil resistant cabtyre cable 2m 6.562ft long with five 0.15mm2 conductors
Cable extension Maximum extension is 100m 328.084ft overall with an equivalent cable with conductors 0.3mm2 or more
Weight Standard type : Approx. 95g 3.35oz, Flat type : Approx. 120g 4.23oz, Light weight type : Approx. 70g 2.47oz
Accessories UZU815 (Hexagon-socket-head plug for pressure port) : 1 pc. (for standard type only), Unit plate : 1 pc.

272
UZU2 series 0.6.10 11:28 Page 5

I/O CIRCUIT AND WIRING DIAGRAMS


NPN output type
I/O circuit diagram Wiring diagram

Color code 10 0kPa


D (Brown) `V

1kΩ (Gray) Analog voltage


Sensor circuit

output (*1) Load


Z D1 (Black) Comparative output 1 Load ` OUT1 OUT2
12 to 24V DC
Tr1 `10
ZD2 100mA max. 1 115 %
(White) Comparative output 2
0-ADJ MODE

Tr2 ZD3 100mA max.


(Blue) 0V

Internal circuit Users’ circuit

(*1): Make sure of the input impedance of your device when the analog output Brown
is used.
Be sure of a voltage drop when the cable is extended by its resistance. Gray To analog
input Load
circuit
Load
Black 12 to 24V DC
Symbol... D : Reverse polarity protection diode `10
ZD1, ZD2, ZD3 : Surge absorption zener diode 115 %
Tr1, Tr2 : NPN output transistor White

m
Blue

co
s.
nt
PNP output type
ne

I/O circuit diagram Wiring diagram


po

Color code 10 0kPa

D (Brown) `V
om

Tr1 ZD1 (Black) Comparative output 1


Sensor circuit

Tr 2 ZD2 100mA max.


(White) Comparative output 2 ` 12 to 24V DC
OUT1 OUT2

`10
1kΩ
100mA max. Load 1 115 %
(Gray) Analog voltage 0-ADJ MODE
Load
ec

output (*1)
ZD3 (Blue) 0V

Internal circuit Users’ circuit


in

Brown
(*1): Make sure of the input impedance of your device when the analog output
is used.
l

Be sure of a voltage drop when the cable is extended by its resistance. Black
on

White 12 to 24V DC
Symbol... D : Reverse polarity protection diode `10
ZD1, ZD2, ZD3 : Surge absorption zener diode 115 %
Load
Tr1, Tr2 : PNP output transistor Gray To analog
input Load
circuit
Blue

273
UZU2 series 0.6.10 11:28 Page 6

DIMENSIONS (Unit: mm inch)


UZU2000, UZU2010
UZU2020 Standard type

31.6
1.244
30 38.5 2-M3 hexagon-socket-head bolts
1.181 LED display 1.516
(2.1) (25.8) 23.5 5 20
3 1/2 digits .787 2-M4
(.083) (1.016) .925 .197

(11)
(.433) 30 31.6 20
1.181 1.244 .787
(18.9)
(.744) (10.9)
(.429) (6) (.236)
Comparative output 2 Pressure port
Increment key operation indicator Rc (PT) 1/8
Mode selection key
Decrement key
Comparative output 1
(9) operation indicator 8 12
(.354) .315 .472
(18) 13
.512
(.709) 14
.551
φ 3.7 φ .146 cable
2m 6.562ft long

UZU2M02, UZU2M12

m
UZU2M22 Flat type

co
30 35
1.181 1.378
(25.8) LED display
(2.1) 23.5
(.083) (1.016) 3 1/2 digits
.925

(11) s.
nt
(.433) 30
1.181
44.7
1.760 (27.9)
(1.098) (19.9)
ne

(.783) (15) Comparative output 2


(.591)
operation indicator
5.7 .224 Mode selection key
po

Comparative output 1
2-φ 8 φ.315 4.4 .173 deep operation indicator
8.2 Pressure port Rc (PT) 1/8 (*1)
(9) Decrement key
(.354) .323
2-φ 4.3 φ .169 Increment key 16
mounting holes (18)
(.709) .630
om

19.5
20 .768
.787 φ 3.7 φ .146 cable
2m 6.562ft long

(*1): North American type substitutes NPT 1/8, and European type substitutes G (PT) 1/8 for it.
ec

UZU2001 Light weight type


l in

30 33.5
on

1.181 1.319
(25.8) LED display
(2.1) 23.5
(.083) (1.016) 3 1/2 digits .925

(11)
(.433) 30
1.181
41
1.614 (23.7)
(.933) (15.7)
(.618) (10.8)
(.425) Comparative output 2
operation indicator
6.2 .244
Mode selection key
Comparative output 1
2-φ 8 φ.315 4.4 .173 deep operation indicator 5 Pressure port M5 4 .157 deep
(9)
(.354) Decrement key .197
2-φ 4.3 φ .169 (18) 10
mounting holes (.709) Increment key .394
20 18
.787 .709
φ 3.7 φ .146 cable
2m 6.562ft long

274
UZU2 series 0.6.10 11:28 Page 7

DIMENSIONS (Unit: mm inch)

UZU811 Sensor mounting bracket for standard type (Option)

Assembled dimensions
40
1.575 25
25 2-φ 4.2 φ.165 mounting holes
.984
.984 2-φ 4.2 φ.165 mounting holes

11 11
.433 20 .433
.787 48.5
39.5 1.909
28.5 1.555
1.122
31.5
1.240
20
.787 30
2-φ 4.2 φ.165 1.181
12.5 3.6
.492 mounting holes 31.6 38.5
.142 1.244 1.516

20 8
.787 .315 45.8
45.5 1.803
5.8 30
1.791 1.181
.228 30 14.2
1.181 .559
20
.787 t1.6 .063
40 24

m
5.8 .228
1.575 .945

co
Material : SPCC (Uni-chrome plated)
Two M4 2 6mm .236inch pan head screws
and two spring washers are attached.

s.
nt
UZU812 + UZU813 Panel mounting bracket and Protective cover for standard type (Option)
ne

Assembled dimensions
po
om

42.7
1.681

Panel cut-out dimensions


ec

36 +0.5
0
43.7 1.417 +.020
1.720 0
9.7 34
in

.382 1.339
40 4.5 .177
1.575
30 3 .118 36 +0.5
0
l

1.181 1.417 +.020


0
on

40 30 42.7 (*1): Thickness of the panel should be


1.575 1.181 1.681 1 to 3.2mm .039 to .126inch.

275
PRECAUTIONS FOR PROPER USE

All models

This product is not a safety sensor. Its use is not Error messages
intended or designed to protect life and prevent When an error occurs, take the following corrective action.
body injury or property damage from dangerous
parts of machinery. It is a normal pressure Error message Cause Corrective action
detection sensor. Overcurrent due to short- Switch off the power supply
The UZU series is designed for use with non- 0 circuit. and check the load.
corrosive gas. It cannot be used with liquid or cor- 0

rosive gas. Applied pressure at the


Pressure is being applied pressure port should be
during zero-point adjust- brought to atmospheric pres-
Functional description 0 ment. sure and zero-point adjust-
0
ment should be done again.
1 NAiS Applied pressure

pressure
–101.3kPa

Positive
3 exceeds the upper
2

type
limit of displayable

m
pressure range.
0 Applied pressure

pressure
Vacuum
OUT1 OUT2 0
exceeds the lower

co
MODE

type
limit of displayable
0-ADJ
pressure range. Applied pressure should be
4 6 brought within the rated
Applied pressure pressure range.

pressure
s. Positive
5 exceeds the lower

type
limit of displayable
nt pressure range.

Description Function 0 Applied pressure


pressure
0 Vacuum
exceeds the upper
31/2digit LED Displays measured pressure, settings, error
type
ne
1 display (Red)
limit of displayable
messages and key-protect status. pressure range.
Comparative Output 1
2 operation indicator Lights up when Comparative Output 1 is ON.
(Orange)
po

Wiring
Comparative Output 2 Make sure to carry out the wiring in the power supply off
3 operation indicator Lights up when Comparative Output 2 is ON.
(Green)
condition.
m

xIn the initial setting mode, pressing the Verify that the supply voltage variation is within the rating.
key changes the settable digit. If power is supplied from a commercial switching regulator,
In the sensing mode, if both the keys are pressed

xIn the Set Value 1, 2 modes, pressing


ensure that the frame ground (F.G.) terminal of the power
co
simultaneously, zero-point adjustment is done.

the key changes the set value to the


high pressure side in case of positive supply is connected to an actual ground.
4 Increment key ( ) pressure type sensor and to the high
vacuum side in case of vacuum pres-
In case noise generating equipment (switching regulator,
inverter motor, etc.) is used in the vicinity of this sensor,
e

sure type sensor.


xIn the sensing mode, if the key is connect the frame ground (F.G.) terminal of the equipment
lin

pressed continuously for 4 sec. or more, to an actual ground.


the display shows peak hold value.
Do not run the wires together with high-voltage lines or
xIn the initial setting mode, pressing the
key changes the set conditions. power lines or put them in the same raceway. This can
on

xIn the Set Value 1, 2 modes, pressing cause malfunction due to induction.
the key changes the set value to the
low pressure side in case of positive
The analog voltage output is not incorporated with a short-
5 Decrement key ( ) pressure type sensor and to the low circuit protection circuit. Do not directly connect a power
vacuum side in case of vacuum pres- supply or a capacitive load.
sure type sensor.
xIn the sensing mode, if the key is
pressed continuously for 4 sec. or more,
the display shows bottom hold value.
xEach press of the key changes the selected
mode to sensing mode, Set Value 1 (P1) set
mode and Set Value 2 (P2) set mode.
Mode selection key xIn the sensing mode, if the key is pressed
6 continuously for about 3 sec., key-protect can
( MODE ) be set/released.
xIn the sensing mode, if the mode selection
key is pressed while pressing the increment
key ( ), the initial setting mode is obtained.
PRESSURE SENSORS
PRECAUTIONS FOR PROPER USE

All models
Setting
If key-protect has been set, make sure to release key-protect before operating the keys.
(Please refer to ‘Key-protect function’ for the procedure.)
Set Value 1 (P1) and Set Value 2 (P2) can be made common for all the output modes.
The setting of Set Value 2 (P2) with respect to Set Value 1 (P1) can only be towards the high pressure side in case of the
positive pressure type sensor and only towards the high vacuum side in case of the vacuum pressure type sensor.
Set Value 3 (P3) is automatically set to the mid-value of Set Value 1 (P1) and Set Value 2 (P2).
(When setting the pressure value for the automatic sensitivity mode)
The conditions which are set are stored in an EEPROM. Kindly note that the EEPROM has a life span and its guaranteed
life is 100,000 write operation cycles.

Setting procedure

1 Zero-point adjustment 2 Initial setting 3 Pressure value setting Measurement

m
Set ‘Display’, ‘Output mode’, Enter Set Value 1 (P1), Set Value 2 (P2), Commence measurement
Adjust zero-point
and ‘Unit’ Set Value 3 (P3) on completion of setting

co
1 Zero-point adjustment 3 Pressure value setting
The displayed pressure when the pressure port is left For the case when output mode is set to either hysteresis

s.
open is adjusted to zero. mode ( ), window comparator mode ( ) or dual output
The sensor will automatically enter the sensing mode ( ).
NAiS

OUT1
–101.3kPa

OUT2
mode when power is supplied.
Let the pressure port be at atmospheric pressure
nt
‘Set Value 1 (P1)’ and Set Value 2 (P2)’ of the com-
parative outputs are set.
(i.e., no applied pressure condition), and press,
ne
0-ADJ
MODE
NAiS –101.3kPa Press MODE key in the sensing mode to set to Set
simultaneously, the increment and decrement Value 1 (P1) set mode.
keys continuously. OUT1 OUT2 Enter Set Value 1 (P1) using key and key.
is displayed and, when the fingers are MODE
po

0-ADJ
Then, press MODE key to set to Set Value 2 (P2) set
released, zero-point adjustment is completed and
mode.
the sensor returns to the sensing mode.
Enter Set Value 2 (P2) using key and key.
2 Initial setting Then, press MODE key to set to sensing mode.
om

Pressure ‘Unit’, ‘Display’ and ‘Output mode’ of the


comparative outputs are set. For the case when output mode is set to automatic sensitivity
setting mode ( ).
NAiS –101.3kPa
In the sensing mode, press MODE
key while press-
‘Set Value 1 (P1)’, ‘Set Value 2 (P2)’ and ‘Set Value 3 (P3)’
ec

ing key.
Initial setting is displayed. of the comparative outputs are set.
OUT1 OUT2

MODE If sensor is being used for the first time, is NAiS –101.3kPa Press MODE key in the sensing mode to set to Set
0-ADJ
displayed. Value 1 (P1) set mode.
lin

The settable digit blinks. OUT1 OUT2 Within the required permissible pressure range,
The settable digit changes when key is 0-ADJ
MODE
having created a pressure state which is nearest
pressed and the setting is changed when key to the atmospheric pressure, press key to
on

is pressed. enter Set Value 1 (P1).


Then, press MODE key to set to Set Value 2 (P2) set
Change with key mode.
3rd digit 2nd digit 1st digit Within the required permissible pressure range,
having created a pressure state which is nearest
to the high pressure end (for a positive pressure
Unit Output mode Display type sensor) or the high vacuum end (for a
vacuum pressure type sensor), press key to
: kPa or : Hysteresis : Digital
MPa mode display enter Set Value 2 (P2).
Then, press MODE key to set to Set Value 3 (P3) set
: kgf/cm2 : Window : Analog
mode.
pressure type pressure type

comparator bar
mode display
Check Set Value 3 (P3) which has been set
Positive

: bar : Dual output


mode automatically. When Set Value 3 (P3) is to be
changed, enter Set Value 3 (P3) using key
: psi : Automatic
sensitivity and key.
setting mode
After checking and setting, press MODE
key to set to
Vacuum

: mmHg
sensing mode.
: inHg
The automatically set Set Value 3 (P3) can be manually
changed to a value between Set Value 1 (P1) and Set Value 2
(P2).
PRESSURE SENSORS

PRECAUTIONS FOR PROPER USE

All models
Conversion of pressure units
In theUZUseries, the conversion mmHg
kPa MPa kgf/cm2 bar psi inHg atm
(Torr)
to different units is automatically
1kPa 1 1⳯ 10ⳮ3 1.01972⳯ 10ⳮ2 1⳯ 10ⳮ2 1.45038⳯ 10ⳮ1 7.50062 0.2953 9.86923⳯10ⳮ3
done on changing the setting of
the pressure unit. However, this 1MPa 1⳯103 1 1.01972⳯10 1⳯10 1.45038⳯102 7.50062⳯103 0.2953⳯103 9.86923
conversion can also be obtained 1kgf/cm2 9.80665⳯10 9.80665⳯ 10ⳮ2 1 9.80665⳯ 10ⳮ1 1.42234⳯10 7.35559⳯ 102 2.8959⳯10 9.67841⳯10ⳮ1
by multiplying the values by the
coefficients given in the table on 1bar 1⳯102 1⳯10ⳮ1 1.01972 1 1.45038⳯10 7.50062⳯102 2.953⳯10 9.86923⳯10ⳮ1

the right. 1psi 6.89473 6.89473⳯10ⳮ3 7.03065⳯10ⳮ2 6.89473⳯10ⳮ2 1 5.17147⳯10 2.036 6.80457⳯10ⳮ2
1mmHg
1.33322⳯10ⳮ1 1.33322⳯10ⳮ4 1.35951⳯10ⳮ3 1.33322⳯10ⳮ3 1.93368⳯10ⳮ2 1 3.9370⳯ 10ⳮ2 1.31579⳯10ⳮ3
(1Torr)
1inHg 3.3864 3.3864⳯10ⳮ3 3.4531⳯10ⳮ2 3.3864⳯10ⳮ2 0.4912 2.5400⳯10 1 3.342⳯10ⳮ2

1atm 1.01325⳯ 102 1.01325⳯ 10ⳮ1 1.03323 1.01325 1.46960⳯10 7.60000⳯ 102 2.9921⳯10 1

m
Key-protect function Others

co
Key-protect is a function which prevents any unintentional Use within the rated pressure range.
change in the conditions which have been entered in each Do not apply pressure exceeding the pressure with-
setting mode by making the sensor not to respond to the standability value. The diaphragm will get damaged and

s.
key operations. correct operation shall not be maintained.
Setting of key-protect Do not use during the initial transient time (0.5 sec.) after
nt
the power supply is switched on.
NAiS –101.3kPa
In the sensing mode, press MODE key continuously Avoid use of standard type, flat type and light weight type
for about 3 sec. and release it immediately when
ne
of sensors in places where steam and dust is excessive.
OUT1 OUT2 is displayed.
0-ADJ
MODE
Key-protect is set and the sensor returns to the Take care that the sensor does not come in direct contact
sensing mode. with water, oil, grease, or organic solvents, such as,
po

thinner, etc.
Do not insert wires, etc., into the pressure port. The
Release of key-protect diaphragm will get damaged and correct operation shall
not be maintained.
m

NAiS –101.3kPa
In the sensing mode, press MODE key continuously Do not operate the keys with pointed or sharp objects.
for about 3 sec. and release it immediately when
co

OUT1 OUT2 is displayed.


MODE
0-ADJ Key-protect is released and the sensor returns to the
sensing mode.
e
lin
on
PRECAUTIONS FOR PROPER USE

Standard type
Setting of pressure lead direction Piping
The pressure lead direction can be changed by When connecting a hexagon-socket-head plug or coupling
dismantling the pressure port attachment and changing to the pressure port, hold the hexagonal part of the
the mounting direction. The tightening torque of the pressure port with a 12mm spanner and make sure that
hexagon-socket-head bolt (length: 9mm or less) should be the tightening torque is 9.8Nzm or less. Also, in order to
0.29N m or less. prevent any leakage, wind a sealing tape on the coupling
when connecting.
Note: Make sure to close any unused pressure port with the hexagon-
socket-head plug supplied as accessory. However, sealing tape is not required for North American
type (UZU21** ) using NPTF 1/8 coupling. (Sealing tape is
Main body
required if NPT 1/8 coupling is used.)
Hexagon-socket-head bolts
12mm spanner

m
Pressure port Pressure

co
attachment ports

Hexagon-socket-head plug

s.
Flat type
Light weight type nt
Setting of pressure lead direction Piping
The pressure lead direction can be changed by When connecting a coupling to the pressure port, hold the
ne
dismantling the pressure port attachment and changing pressure port attachment with a 16mm (light weight type:
the mounting direction. The tightening torque of the 10mm) spanner and make sure that the tightening torque
hexagon-socket-head bolt (length: 9mm or less) should be is 9.8N m or less (light weight type: 1.47N m or less).
po

0.29N m or less. Also, in order to prevent any leakage, wind a sealing tape
on the coupling when connecting.
Pressure port attachment
m

Hexagon-socket-head bolts

Main body
e co

2-" 4.3mm mounting holes 16mm


(light weight type: 10mm)
lin

Pressure port spanner


on

IP67 type
Piping for pressure measurement inlet port Fitting of front cover
When connecting a coupling to the pressure measurement Insert the bosses on the front cover into the guide holes at
inlet port, hold the pressure port attachment with a the bottom of the pressure port attachment, and push in
spanner and make sure that the tightening torque is the direction of the arrow to fit the hook.
9.8N m or less. Also, in order to prevent any leakage, wind When removing the front cover, release the hook first.
a sealing tape on the coupling when connecting.
Piping for atmospheric pressure inlet port Hook
If there is a possibility of water
Safe place, where
entering into the sensor there is no expo-
sure to water
enclosure through the atmo-
spheric pressure inlet port, Atmospheric
pressure inlet port
connect a tube to the atmo-
M5 coupling
spheric pressure inlet port
through a M5 coupling and
extend the other end of the
Tube Guide holes
tube to a safe place. In this
case, ensure that this end of Pressure measurement
inlet port
the tube does not get clogged.