You are on page 1of 2

Footing Design: Sizing Data For All Load Combinations Page 1 of 1

PRESSURE CHECK FOR ALL LOAD COMBINATIONS


Project Name : 2STOREY HOUSE-FOOTING
Client Name : NE
Engineer Name : CELO
Design File : C:\Users\Marcelo\Documents\sideline\RAKET-
CELO\RCDC\FOOTING...rcdx
Analysis File : C:\Users\Marcelo\Documents\sideline\RAKET- CELO\2STOREY
HOUSE.std
Analysis Last Modified : 2/21/2021 12:33:20 PM

Load Combinations
(L / C):
1. 1.2 (LOAD 1: DL) +1.6 (LOAD 2: LL)

Footing No = FC1
Column No = C1
Design Code = ACI 318M - 2011
Depth of founding layer = 4 m
Density of Soil = 18 kN/cum
Soil Bearing Capacity = 200 kN/sqm
Permissible SBC Increase for EQ = 0 %
Permissible SBC Increase for Wind = 0 %
Live Load Reduction = 0 %
Design cross section by = Average pressure
Footing Type : Pad
Footing Size (L X B X D) : 900mm X 850mm X 300mm
Effective Self Weight = 5.74 kN

Design Table (C1):


L / Analysis Analysis Forces Ptotal Soil Pressures Max. Soil Min. Soil SBC Permissible Loss of
C L/C No =P+ Pressures Pressures Increase Net SBC Contact
P Mx My Eff. P/A Mx/Zxx My/Zyy (kN/sqm) (kN/sqm) (%) (kN/sqm) (%)
(kN) (kNm) (kNm) Self (kN/sqm) (kN/sqm) (kN/sqm)
Wt
(kN)
2 4 99.89 -6.16 -0.02 106.77 139.58 -53.68 -0.18 193.4 85.75 0 200 0
file:///C:/Users/Marcelo/AppData/Local/Temp/tmp1006.tmp 2/22/2021

You might also like