You are on page 1of 6

SIMATIC PT785\SIMATIC 318-PT\CPU 318-2\...

\FC519 - <offline> 11/27/2020 10:54:08 AM

FC519 - <offline>
"50.x2 VERST.SOLLW ZUGSP." DES.PULLVAL ADJUSTMENT
Name: Family:
Author: PT794 Version: 2.0
Block version: 2
Time stamp Code: 06/05/2002 11:10:16 AM
Interface: 11/21/2000 05:34:26 PM
Lengths (block/logic/data): 00900 00718 00026

Object properties:
S7_language 9(2) English (United Kingdom) 11/27/2020 10:46:33 AM

Name Data Type Address Comment


IN 0.0
OUT 0.0
IN_OUT 0.0
TEMP 0.0
RETURN 0.0
RET_VAL 0.0

Block: FC519 50.XX SELECT. DES. PULL TENS. VAL.

Network: 1 UNIT FOR OP AND VISUALISATION

IN THIS NW WE CAN WRITE THE UNIT FOR EACH KIND OF PRODUCTION OF EACH ROOL. THIS
UNIT WILL BE TRANSFERD TO THE OP OR THE VISU.
THIS IS THE ONLY POSITION IN THE PROGRAMM WHERE THE UNIT IS DEFINED.
IN THE FOLLOWING 2 * 5 BYTES YOU CAN WRITE THE UNIT (%, M/MIN), WHICH WILL
SHOWN AT THE OP OR VISU FOR EACH KIND OF PRODUCTION..

BYTE 32 TO BYTE 36 ARE FOR THE INLINE PROGRAMMING,


BYTE 74 TO BYTE 78 ARE FOR THE OUTLINE PROGRAMMING.

THERE ARE MAX. FIVE SIGNS FOR EACH KIND OF PRODUCTION .


NOT USED BYTES MUST FILLED WITH AN EMPTY SIGN.

THE SIGN ' ' MARKS THE STRING AND MUST BE USED.

//UNIT FOR INLINE


L '%' //FIRST SIGN INLINE
T "50.x2 DB SOLLW ZUGSP.".Sollwert_Zugspannung.SOLL DB519.DBB32 -- DESIR
_INLINE_EINHEIT[1] . VALUE UNIT FOR DISPLAY (I
NLINE) ['% ' OR 'M/MIN']
L ' ' //SECOND SIGN INLINE
T "50.x2 DB SOLLW ZUGSP.".Sollwert_Zugspannung.SOLL DB519.DBB33 -- DESIR
_INLINE_EINHEIT[2] . VALUE UNIT FOR DISPLAY (I
NLINE) ['% ' OR 'M/MIN']
L ' ' //THIRD SIGN INLINE
T "50.x2 DB SOLLW ZUGSP.".Sollwert_Zugspannung.SOLL DB519.DBB34 -- DESIR
_INLINE_EINHEIT[3] . VALUE UNIT FOR DISPLAY (I
NLINE) ['% ' OR 'M/MIN']
L ' ' //FOURTH SIGN INLINE
T "50.x2 DB SOLLW ZUGSP.".Sollwert_Zugspannung.SOLL DB519.DBB35 -- DESIR
_INLINE_EINHEIT[4] . VALUE UNIT FOR DISPLAY (I
NLINE) ['% ' OR 'M/MIN']
L ' ' //FIVETH SIGN INLINE
T "50.x2 DB SOLLW ZUGSP.".Sollwert_Zugspannung.SOLL DB519.DBB36 -- DESIR
_INLINE_EINHEIT[5] . VALUE UNIT FOR DISPLAY (I
NLINE) ['% ' OR 'M/MIN']

//UNIT FOR OUTLINE


L 'm' //FIRST SIGN OUTLINE
T "50.x2 DB SOLLW ZUGSP.".Sollwert_Zugspannung.SOLL DB519.DBB74 -- DES.V
_OUTLINE_EINHEIT[1] AL. UNIT FOR DISPLAY (OUTLI
NE) ['% ' OR 'M/MIN']
L '/' //SECOND SIGN OUTLINE
T "50.x2 DB SOLLW ZUGSP.".Sollwert_Zugspannung.SOLL DB519.DBB75 -- DES.V
_OUTLINE_EINHEIT[2] AL. UNIT FOR DISPLAY (OUTLI
NE) ['% ' OR 'M/MIN']

Page 1 of 6
SIMATIC PT785\SIMATIC 318-PT\CPU 318-2\...\FC519 - <offline> 11/27/2020 10:54:08 AM

L 'm' //THIRD SIGN OUTLINE


T "50.x2 DB SOLLW ZUGSP.".Sollwert_Zugspannung.SOLL DB519.DBB76 -- DES.V
_OUTLINE_EINHEIT[3] AL. UNIT FOR DISPLAY (OUTLI
NE) ['% ' OR 'M/MIN']
L 'i' //FOURTH SIGN OUTLINE
T "50.x2 DB SOLLW ZUGSP.".Sollwert_Zugspannung.SOLL DB519.DBB77 -- DES.V
_OUTLINE_EINHEIT[4] AL. UNIT FOR DISPLAY (OUTLI
NE) ['% ' OR 'M/MIN']
L 'n' //FIVETH SIGN OUTLINE
T "50.x2 DB SOLLW ZUGSP.".Sollwert_Zugspannung.SOLL DB519.DBB78 -- DES.V
_OUTLINE_EINHEIT[5] AL. UNIT FOR DISPLAY (OUTLI
NE) ['% ' OR 'M/MIN']

Page 2 of 6
SIMATIC PT785\SIMATIC 318-PT\CPU 318-2\...\FC519 - <offline> 11/27/2020 10:54:08 AM

Network: 2

FC1000
FUNCTION FOR ROLL
DRIVES
"FC-X WALZEN"

EN

DB519
DATA
DES.PULL.V
ALU.ADJUST
MENT
"50.x2 DB
SOLLW
ZUGSP." DB_NR

M0.1
FLAG IS
ALWAYS "1"
"M0.1 FC7
IMMER FREIGABE_
EINS" EIN

M0.1
FLAG IS
ALWAYS "1"
"M0.1 FC7
IMMER
EINS" S_AUS_EIN

M0.1
FLAG IS
ALWAYS "1"
"M0.1 FC7
IMMER WS_
EINS" MITLAUF

M0.0
FLAG IS
ALWAYS "0"
"M0.0 FC7
IMMER WS_
NULL" GEGENLAUF

M0.1
FLAG IS
ALWAYS "1"
"M0.1 FC7
IMMER
EINS" OUTLINE

I122.0
WT
DES.PULLVA
L +
"=13.1+
13P2-S3.1
/1" WT_PLUS

I122.1
WT
DES.PULLVA
L -
"=13.1+
13P2-S3.1
/2" WT_MINUS

M0.0
FLAG IS
ALWAYS "0"
"M0.0 FC7 STOERUNG_
IMMER NETZSCHUE
NULL" TZ

M0.1
FLAG IS
ALWAYS "1"
"M0.1 FC7 STOERUNG_
IMMER FREMDLUEF
EINS" TER

Page 3 of 6
SIMATIC PT785\SIMATIC 318-PT\CPU 318-2\...\FC519 - <offline> 11/27/2020 10:54:08 AM

EINS" TER

M0.1
FLAG IS
ALWAYS "1"
"M0.1 FC7
IMMER STOERUNG_
EINS" UMRICHTER

M0.1
FLAG IS
ALWAYS "1"
"M0.1 FC7 STOERUNG_
IMMER MOTORSCHU
EINS" TZ

M0.0
FLAG IS
ALWAYS "0"
"M0.0 FC7 STOERUNG_
IMMER THERMISTO
NULL" R

M0.0
FLAG IS
ALWAYS "0"
"M0.0 FC7
IMMER STOERUNG_ DB519.DBW1
NULL" RES1 34
"50.x2 DB
M0.0 SOLLW
FLAG IS ZUGSP.".
ALWAYS "0" PAW_ RES_WORD_
"M0.0 FC7 ANZEIGE 134
IMMER STOERUNG_
NULL" RES2 M99.0
FLAG AS
MW108 WILDCARD
DES.VALUE OUTPUT
DRIVE (SCRATCH
"MW108 FLAG)
SOLLWERT SOLL_ A_ "M99.0
ANTRIEBE" ANTRIEB NETZSCHUE DUMMY BIT
TZ OUTPUT"
SOLL_
9.000000e+ INLINE_ M99.0
001 MIN FLAG AS
WILDCARD
SOLL_ OUTPUT
1.100000e+ INLINE_ (SCRATCH
002 MAX FLAG)
A_FU_ "M99.0
SOLL_ REGLERFRE DUMMY BIT
1.000000e+ OUTLINE_ IGABE OUTPUT"
000 MIN
M99.0
SOLL_ FLAG AS
1.000000e+ OUTLINE_ WILDCARD
002 MAX OUTPUT
(SCRATCH
DB519.DBD1 FLAG)
12 "M99.0
FIN.VAL A_FU_ DUMMY BIT
ANALOG MITLAUF OUTPUT"
MODULE
[27647 M99.0
INCREMENTS FLAG AS
] WILDCARD
"50.x2 DB OUTPUT
SOLLW (SCRATCH
ZUGSP.". FLAG)
Sollwert_ "M99.0
Zugspannun A_FU_ DUMMY BIT
g. GEGENLAUF OUTPUT"
MAX_INKR_
Siemens MAX_INKR ENO

Page 4 of 6
SIMATIC PT785\SIMATIC 318-PT\CPU 318-2\...\FC519 - <offline> 11/27/2020 10:54:08 AM

Network: 3 TENSION RATED VALUE TO DISPLAY / MAIN DRIVE

IN PT794 WAS STANDING L 1.999983E+000

L "50.x2 DB SOLLW ZUGSP.".RES_WORD_134 DB519.DBW134


T "=13.1+13P1-12.1" PQW416 -- PAW DESPULLVALU

L "50.x2 DB SOLLW ZUGSP.".Sollwert_Zugspannung.SOLL_OUTLINE_ANALOG_OUT DB519.DBW92 -- DES.VAL. TO ANALOG


MODULE (OUTLINE)
DTR
L 1.687500e+000
/R
RND
T "50.x2 DB SOLLW ZUGSP.".Zugsollwert_DM1 DB519.DBW142

Network: 4 PULL TENS. ACT.VALU

AN "13.01 DB IPW ALLG.".VORWAHL_1_2_STUFIG DB13.DBX0.0 -- PRESELECTIO


N WITHOUT OR WITH COMBI COATER
JC M100
L "=19.1+M1-5.1" PIW296 -- PEW TENSION
ACTUAL DATA COATER
JU M200
M100: NOP 0
L "60.13.1 DB ANTR IPW-E".AIF_OUT_W2 DB604.DBW12 -- DM1 ACT.TEN
S.V
DTR
L 1.687500e+000
*R
RND
// L PEW 306 //ZUGSPANNUNGS ISTWERT DM1
M200: NOP 0
L 0
<=I //LIWITH TO +0% MIN REAL VALUE
JC M001
TAK

M001: DTR //OUTPUT FROM AMPLIFIRE


L 2.764800e+000 //FOR TRACTION DISPLAY MONITOR
/R
A "13.01 DB IPW ALLG.".VORWAHL_1_2_STUFIG DB13.DBX0.0 -- PRESELECTIO
N WITHOUT OR WITH COMBI COATER
JC M102
A "T59 - FC503 - EVERZ" T59 -- WBR CONTROL
ON
JC M002 //WHEN WBR MOVE AWAY DISPLAY 0
JU M103
M102: NOP 0
A "T34 - FC244 - EVERZ" T34 -- WBR COATER
AUTOMATIC ON
JC M002

M103: L 0.000000e+000
M002: T "50.x2 DB SOLLW ZUGSP.".Zugistwert_REAL //TRACTION REAL VALUE 0-100.0% DB519.DBD166
RND
T "50.x2 DB SOLLW ZUGSP.".Zugistwert_INT //TRACTION REAL VALUE 0-100% DB519.DBW144
L 0

AN "13.01 DB IPW ALLG.".VORWAHL_1_2_STUFIG DB13.DBX0.0 -- PRESELECTIO


N WITHOUT OR WITH COMBI COATER
JC M101
L "=19.1+M1-5.1" PIW296 -- PEW TENSION
ACTUAL DATA COATER
JU M201
M101: NOP 0
// L PEW 306 //ZUGSPANNUNGS ISTWERT DM1
L "60.13.1 DB ANTR IPW-E".AIF_OUT_W2 DB604.DBW12 -- DM1 ACT.TEN
S.V
DTR
L 1.687500e+000
*R
RND

M201: NOP 0

>=I //REAL VALUE LOWER 0


JC M003 //OUTPUT 0
A "13.01 DB IPW ALLG.".VORWAHL_1_2_STUFIG DB13.DBX0.0 -- PRESELECTIO
N WITHOUT OR WITH COMBI COATER

Page 5 of 6
SIMATIC PT785\SIMATIC 318-PT\CPU 318-2\...\FC519 - <offline> 11/27/2020 10:54:08 AM

JC M202
A "T59 - FC503 - EVERZ" T59 -- WBR CONTROL
ON
JC M004 //WHEN WBR MOVE AWAY DISPLAY 0
JU M003
M202: NOP 0
A "T34 - FC244 - EVERZ" T34 -- WBR COATER
AUTOMATIC ON
JC M004

M003: L 0
M004: NOP 0

T "=13.1+13P1-12.4" //TRACTIONDISPLAY REAL VALUE +13P2 PQW418 -- PAW ACTPULL


VAL

Network: 5 PULL TENS. ACTVALUE TO VISU

DIV_R
EN

DB519.DBD1 DB519.DBD1
66 70
"50.x2 DB "50.x2 DB
SOLLW SOLLW
ZUGSP.". ZUGSP.".
Zugistwert Zugistwert
_REAL IN1 _VISU_
OUT PROZENT
1.000000e+
002 IN2 ENO

Network: 6

L "50.x2 DB SOLLW ZUGSP.".Zugsollwert_DM1 DB519.DBW142


DTR
L 1.638400e+002
/R
T "50.x2 DB SOLLW ZUGSP.".Zugsollwert_VISU_PROZENT DB519.DBD174