Professional Documents
Culture Documents
iPASOLINK VR 4
SPECIFICATIONS
NEC Corporation
7-1, Shiba 5-Chome, Minato-Ku, Tokyo 108-8001, Japan
Submission Prohibited
NEC Group Internal Use Only
GGS-000396-06E
GGS-000396-06E
Printed in Japan
Submission Prohibited
NEC Group Internal Use Only
CONTENTS –i–
iPASOLINK VR 4
SPECIFICATIONS
CONTENTS
1. INTERFACES 1-1
2. SPECIFICATION 2-1
1. INTERFACES
[ON-BOARD
MODEM]
➀ ➁ ➂➃ ➄
➇ ➈➉
11
12 13
➅ ➆
➁ IF1 TNC Connector IF Terminal connecting to the Outdoor Unit (ODU); SYS1
IF2 TNC Connector IF Terminal connecting to the Outdoor Unit (ODU); SYS2
➂ CALL Push Button Press the button to call the opposing site by OW.
➄ CLK High Density D-Sub (Optional) Terminal for Clock Signal input/output. (15 pins)
Connector
➅ ODU PWR IF1 Rocker Switch Switch to supply/shut-down power to ODU 1 (using IF1).
ODU PWR IF2 Rocker Switch Switch to supply/shut-down power to ODU 2 (using IF2).
➆ MEM USB Type-A Connecting terminal for USB memory device. (Supporting
a memory device only.)
➈ LCT RJ-45 Connector Ethernet port for connecting WebLCT. (Supporting 10/
100BASE-TX; Auto-Negotiation, Auto-MDI/MDIX.)
11 NE/1 RJ-45 Connector Two-Way Use: Terminal for connecting DCN Network
downstream., or traffic Ethernet signal input/output Port 1.
(Supporting 10/100/1000BASE-TX; Auto-Negotiation,
Auto-MDI/MDIX)
13 SELV PWR 1/2 DK3100 Power Input Terminal for IDU. SELV, –48 V DC. PWR 2 is
an optional.
1.2.1.2 FAN-CV
1.2.2.1 MODEM-EA
➀ ➁ ➂ ➃
1.2.2.2 MODEM-AV
NOTE: MODEM-AV is currently not available to use when the Equipment
Mode is set to MPLS-TP.
➀ ➁ ➂
1.2.2.4 16E1-A
1.2.2.5 GbE-A
2. SPECIFICATION
1000BASE-SX/LX/CWDM 1.25 Gbps LC (SFP Module) 2 on MC-AV (The rate of Ports #5 and #6
[802.3] on MC-AV are fixed.)
NOTE: 10 GbE Interface is currently not available when the Equipment Mode is set to
MPLS-TP.
2.1.2 E1 Interface
INTERFACE SPEC CONNECTOR SUPPORTING CARD
S-1.1 / L-1.1 [G.957] 2 × 155.52 Mbps LC (SFP Module) 2 on STM1-A Through (up to 6 ports per
IDU)
CWDM
IF (IDU-ODU Interface) –48 V DC, TX IF, TNC 2 on MC-AV (On-Board MODEM) NOTE:
RX IF, ODU SV
1 on MODEM-EA (up to 3 ports per IDU)
NOTE: MODEM-AV is currently not available to use when the Equipment Mode is set
to MPLS-TP.
Radio Capacity
Modulation
CS: 7 MHz CS: 14 MHz CS: 28 MHz CS: 40 MHz CS: 56 MHz
Radio Capacity
Modulation
CS: CS: CS: CS: CS: CS: CS:
7 MHz 14 MHz 28 MHz 40 MHz 56 MHz 80 MHz 112 MHz
NOTE: MODEM-AV is currently not available to use when the Equipment Mode is set
to MPLS-TP.
NOTE: QoS (VLAN Based) is currently not available when the Equipment Mode is set
to MPLS-TP.
2.2.4 MPLS-TP
Functions Supported Items
2.2.6 Synchronization
Functions Supported Items
NOTE: PTP is currently not available when the Equipment Mode is set to MPLS-TP.
2.3.1 STM-1
ITEM SPECIFICATIONS
Maximum Mean Launched Power –28 dBm –34 dBm –34 dBm
Others
2.3.2 1000BASE-X
ITEM SPECIFICATIONS
Maximum Mean Launched Power –17 dBm –19 dBm –22 dBm
Others
2.3.3 10GBASE-R
NOTE: 10 GbE Interface is currently not available when the Equipment Mode is set to
MPLS-TP.
ITEM SPECIFICATIONS
SMSR —— 30 dB 30 dB
Maximum Mean Launched Power –2.8 dBm 0.5 dBm 4.0 dBm
Minimum Mean Launched Power –4.3 dBm –8.2 dBm –4.7 dBm
Maximum Mean Launched Power –1.0 dBm 0.5 dBm –1.0 dBm
Minimum Mean Launched Power –9.9 dBm –14.4 dBm –15.8 dBm
Others
Type of Fiber Cable MMF: SI Cable, Core/ SMF: Core/Clad SMF: Core/Clad
Clad (dia.: 9/125 µm) (dia. 9/125 µm) (dia. 9/125 µm)
3. SYSTEM PERFORMANCES
3.2.1 Temperature
Condition Requirements
Operating –5 to +50°C
Reference: –5 to+45°C by ETSI EN 300 019-1-3
Class 3.1E in the EU market
3.2.2 Humidity
Condition Requirements
Condition Requirements
here
The rated current for iPASOLINK VR 4, which previously was 8 A, has been
changed to 12 A since July 2016 due to newly added systems and functions.
3.4 Others
Category Standards