1 Experiment content
1.1 Digital part experiment contain:
1. TTL logical gate parameters test and use 2. CMOS Integration logic gate of the test
3. Gate circuit logic function test 4. Common combination logic function components test
5. Data collect and application 6. Blood type relationship detection circuit and voting circuit
7. RS function of the trigger and test 8. JK trigger logic function and main parameters test
9. The shift register function test 10. Decade computer(CMOS)
11. Asynchronous counter 12. Synchronous counter
13. Count decode display circuit experiment 14. 555 Integrated timer and application
15. Sequential detector 16. Follow type is A/D conversion circuit
17. Artificial control traffic light controller 18. Automobile tail light control circuit
19. Digital circuit design 20. Timing circuit testing and research
21. Wave shape generate and monostable trigger 22. A/D convert circuit
23. D/A convert circuit
1.2 Analog part experimental contents: 1, Rectifier voltage filter and parallel circuit
2, Series voltage stabilizing circuit
3, Integrated voltage stabilizing circuit
4, Integrated power amplifier
5, Complementary symmetry power amplifier
With bread board and expand chip
Supply English user manual
reliable contact, and long service life, high efficiency, effectively prevent electric shock hazard.
Experiments on the front panel with element symbols and main parameters for the student identification.
Visual in experiment box structure is compact and practical, safe and reliable, effectively raises student's
beginning ability, easy maintenance and simple way.
2 System composition
(1) Power supply: three-phase 220 v + 10%, 50 Hz
(2) Coupling inductance of a couple.
(3) Single-phase transformer, transformer ratio than 36 v to 220 v, 50W.
(4) Three-phase headlamp unit load, each phase can be inserted into the 15 w bulb 3 only.
(5) Three-phase load capacitance, 0.47uf/400V、luf/400V、2uf/400V each type with 3 units
(6) Three-phase switch l only. (7) Components set: is there a fuse holder 3, ballast (20 w) l only, only, the
starter resistance, luf, 2uf, 4uf capacitor element and so on. Pointer type voltmeter head l
(8) Pointer type current meter head l.
(9) Three phase four wire leakage circuit breaker is a piece of choose and buy, the user selected
according to specific circumstances.
3 Experiment list
(1) Three meter method measurement circuit equivalent parameters. (2) Research of sinusoidal steady
state circuit phasor. (3) Mutual inductance circuit measurement.
(4) Characteristics of single-phase transformer testing.
(5) Measuring the voltage and current of three-phase ac circuit.
(6) Three-phase circuit power measurement.
(7) Measuring the phase sequence and power factor.
(8) Other electricians control experiment.
10
Experimental list: 1. TTL integrated logical gate parameters test and use 2. Tests of CMOS integrated
logical gate 3. The gate the logic function of the experiment 4. Common combined logic function device
test 5. A half adder, full adder and logic operation experiment 6, seven people voting circuit and blood
type detection circuit 7, RS trigger function test 8, JK, D trigger logic function and main parameters of the
test 9 and 3 state output, and latch 10, asynchronous binary counter experiment 11, synchronous binary
counter 12, functional test of the shift register 13, counting, decoding, display circuit experiment 14, 555
integrated circuits and application 15, waveform and the monostable trigger 16. sequence detector 17,
D/A D/A converters 18, A/D analog-to-digital converter 19, the traffic light controller can be manual
intervention, 20 and digital electronic clock design 21, digital frequency meter 22, automobile tail light
control experiment
11
1 Technical performance
Input voltage: single-phase three-wire system 220 V (1 ± 10%) 50 Hz; 2.2 Working environment: The
ambient temperature is -5 ℃ ~ + 40 ℃; 2.3 Device capacity: <1KVA
2 Training devices:
Provide 1 copy of analog electronic manual;
Provide a digital circuit manual; 3.4.3 Provide 1 set of training wires;
Provide a digital multimeter;
Provide one set of commonly used integrated chips;
3 Experimental items: 1) Use of common electronic instruments 2) Simple test of diode 3) Input and
output characteristics experiment of transistor 4) Single stage amplifier circuit 5) Two-stage amplifier
circuit 6) Negative feedback amplifier circuit 7) Emitter follower 8) Differential amplifier circuit 9) FET
amplifier 10) RC sine wave oscillation circuit 11) LC oscillator and frequency selection amplifier 12) Basic
parameter test of integrated operational amplifier 13) Integrated op amp ratio sum operation circuit 14)
Integrating and Differential Circuits for Integrated Op Amps 15) Voltage comparator circuit with integrated
op amp 16) Waveform generator 17) Active Filter 18) Integrated Power Amplifier 19) complementary
symmetrical power amplifier 20) Integrated voltage regulator 21) Series regulator circuit 22) Thyristor
controllable rectifier circuit 23) Transistor switching characteristics, limiter and clamp 24) Logic function
and parameter test of TTL integrated logic gate 25) Connection and drive of TTL integrated logic circuit
26) Design and test of combinational logic circuits 7) Encoder and its application 28) Decoder and its
application 29) Data selector and its application 30) RS trigger and its application 31) JK trigger and its
application 32) D trigger and its application 33) Counters and their applications 34) Using a gate circuit to
generate a pulse signal 35) Monostable trigger and Schmitt trigger 36) 555 time base circuit and its
application
12
(1) Workbench type structure, upright with steel pipe spraying, aluminum alloy fixed beam, can be fixed
on desktop.(2)The trainer has good safety protection system.
2 Performance parameter(1) Input power: single phase three wire system 220V±10% 50Hz (2)
Dimension: 1200mm×400mm×700mm (3) Completer machine capacity: < 1.5KVA (4) Weight: < 50kg
3 Product formation
3.1 Hanging box frame: Upright on both sides made of 20*40mm steel pipe, its surface deal with
spraying plastics, module fixed beam made of special aluminum alloy.
3.2 Module hanging box: It was assembled with special aluminum, hanging box unified height is
297mm, which is the same size with A4 paper, different module can be used in any combination.
4 Technical Specifications: THE TRAINING SYSTEMS WILL CNSISTS OF THE FOLLWING
MODULES: a)Basic Electronic Circuits Module: Diode and Transistor Switch, Voltage Follower and
Comparator, Zero Crossing Detector, Photoelectric Controller, b)Waveform Generator Module: Schmitt
Trigger and Sparkling Lamp, 555 Delay Circuit and Astable Multi vibrator, Delay Turn off Circuit, OPA
Astable Multi vibrator, c)Digital Circuits Module: BCD Adder and Sub –tractor, Mono-stable and Alarm
Circuit, Touch Switch and 4518 Counter d)Signal Process Circuits Module: R-2R Ladder Network, A/D
and D/A Converter, Low-pass, High pass, Band pass and Band stop Filter e)Regulator DC Power Supply
Module: 7805 and 7905 Regulator Characteristics, 7805 and 7905 Expanded Voltage 780-5 and 7905
Variable Regulator, 7805 and 7905 Current Source, f)LED & Transistor Application Circuits Module:
Electrons Competition – answer Machine, Basic Remote Lamp Controller (DC), Remote Lamp Controller
(AC), Electronic Wheel amusement Machine g)Function Generator & DC Power Supply Module:
Waveforms: Sine, Triangle, square, TTL Pulse, Amplitude: >10 Vpp, Impedance: 50Ω±10%, Duty
Control: 30% ~ 60%, Display: 6 Digit LED Display, Frequency Range: 10Hz to 100 KHz (4 Ranges),
100Hz to 1MHz (4 Ranges), Frequency Control: Separative Coarse and Fine Tuning , Constant Voltage
Output: ±5V, ±12V, Variable Voltage Output: 0V ~ ±15V, Power Requirements: 220 ~ 240V AC, 50Hz
h) Power supply module: Constant output voltage: ±5V, ±12V, Variable output voltage: 0V ~ ±15V,
Power supply: 220 ~ 240V AC, 50Hz.
13
3 Experiment list:
Experiment 1 The use of basic electrical instruments and the calculation of measurement errors,
Experiment 2 Method for reducing the measurement error of the meter, Experiment 3 Ohm's law
Experiment 4 Instrument Range Extension, Experiment 5 Mapping of volt-ampere characteristics of
linear and nonlinear circuit components, Experiment 6 Determination of potential and voltage and
drawing of circuit potential map Experiment 7 Verification of Kirchhoff's Law, Experiment 8 Verification of
the superposition principle, Experiment 9 Equivalent transformation of voltage source and current source,
Experiment 10 Verification of Thevenin's Theorem and Norton's Theorem Test 11 Determination of
equivalent parameters of active two-terminal network, Experiment 12 Determination of maximum power
transmission conditions
Experiment 13 Two-port network test, Experiment 14 Reciprocity Theorem, Experiment 15 Experimental
study of controlled sources VCVS, VCCS, CCVS, CCCS Experiment 16 Observation and measurement
of typical electrical signals, Experiment 17 Response test of RC first-order circuit, Experiment 18: Study
on the response of second-order dynamic circuit, Experiment 19: Determination of impedance
characteristics of R, L and C components Experiment 20 RC string, parallel double T frequency selection
network characteristics test Experiment 21: Research on R, L, C Series Resonant Circuits, Experiment
22 RC dual T frequency selective network Experiment Twenty-three Study of Phasor Trajectories in RL
and RC Series Circuits Experiment 24: R, L, C component characteristics and AC parameters
determination Experiment 25 Measurement of AC circuit parameters Experiment 26 Study on phasor of
sinusoidal steady-state AC circuit Experiment 27 Test of characteristics of single-phase iron core
transformer Experiment 28: Determination of winding polarity of transformer Experiment 29
Verification of single-phase watt-hour meter Experiment 30 Measurement of power factor and phase
sequence Experiment 31: Negative Impedance Converter Experiment thirty-two gyrator
14
2 Experiment list
Digital circuit part: Experiment 1 Transistor Switching Characteristics, Limiter and Clamp, Experiment 2
Logic function and parameter test of TTL integrated logic gate, Experiment 3 Logic function and
parameter test of CMOS integrated logic gate, Experiment 4 Connection and drive of integrated logic
circuits
Experiment 5 Design and test of combinatorial logic circuit, Experiment 6 Decoder and its application
Experiment 7 Data Selector and Its Application, Experiment 8 Trigger and its application, Experiment 9
Counter and its application, Experiment 10 Shift register and its application, Experiment 11 Pulse
Distributor and Its Application, Experiment 12: Using a gate circuit to generate a pulse signal---self-
excited multivibrator Experiment 13 Monostable Trigger and Schmitt Trigger---Pulse Delay and
Waveform Shaping Circuit, Experiment 14 555 time base circuit and its application, Experiment 15 D/A.
A/D converter, Experiment 17 electronic stopwatch, Experiment 18 3-bit DC digital voltmeter, Experiment
19 Digital Frequency Meter Analog electronic tester, Experiment 1 Use of commonly used electronic
instruments, Experiment 2 Simple test of diode, Experiment 3 Experiment of input and output
characteristics of crystal triode, Experiment 4 Single-stage amplifier circuit, Experiment 5 two-stage
amplification circuit, Experiment 6 Negative feedback amplifier circuit, Experiment 7 emitter follower,
Experiment 8 Differential Amplifying Circuit, Experiment 9 FET amplifier, Experiment 10 RC sine wave
oscillation circuit, Experiment 11 LC oscillator and frequency selective amplifier, Experiment 12 Basic
parameter test of integrated operational amplifier, Experiment 13 Integrated Operational Amplitude
Proportional Operation Circuit, Experiment 14 Integration and differential circuits of integrated op amps,
Experiment 15 Voltage Comparator Circuit of Integrated Op Amp
Experiment 16 Waveform Generator, Experiment 17 Active Filter, Experiment 18 Integrated Power
Amplifier Experiment 19 Complementary Symmetrical Power Amplifier, Experiment 20 Integrated Voltage
Regulator Experiment 21 series voltage regulator circuit
15
1 Overview: The training sets include a variety of electronics experiments, raises the student the
corresponding knowledge and skills, suitable for higher vocational colleges, higher technical, secondary
vocational school and technical school related professional teaching and skill training evaluation.
2 Power control panel: The power control panel using aluminum alloy profile panel, enclosed body
structure, and placed at the bottom of a connection as one.
3 Power box (1)Three phases, five wires power input, it has been tested by leakage breaker control,
it has emergency stop button, you can cut off electricity when emergency.
(2) Power box parameters: aluminum profile box, leakage protection circuit breaker, power indicator
light, emergency stop switch, provide AC 220V output socket, DC fixed 5V, plus or minus 12V, DC 0-36V
adjustable output, low voltage AC 6V, 12V output , DC voltmeter, DC ammeter
Feature: (1) Training bench with aluminum column frame structure, the power supply built-in integrated
installation, safe and convenient to use, is not easy to damage. (2) unit circuit hanging box configuration
are complete, combination use, complete variety of critiquing the training content. (3) It can be set for an
experiment subjects related units hang flexible increase or decrease in the box, in order to meet different
user requirements. (4) Training platform has a good safety protection system.
Diode experiment 1) Characteristics of the diode 2) Forward and reverse basis
3) Half-wave rectifier 4) Full wave rectifier 5) Bridge rectifier 6) Shearing 7) Clamping 8) Voltage doubler
Zener diode experiment 1) Characteristics of Zener diodes 2) Voltage stabilizer 3) Fixed Vi / Variable
RL 4) Variable Vi / Fixed RL Transistor experiment configuration 1) Common foundation 2) Common –
Transmitter 3) Common – collectors D.C bias Fixed - bias circuit Emitter - stable bias circuit (self-bias
voltage) voltage - voltage divider bias effect Field effect transistor (FET) 1) Characteristics of JFET 2)
Characteristics of MOSFET PNPN devices 3) SCR 4) Shockley diode 5) Two-terminal AC switch 6)
Triacs 7) IGBT
Operational amplifier experiment 1) Inverting amplifier 2) Non-inverting amplifier
3) summing amplifier 4) Integral amplifier 5) Differential amplifier 6) Comparator amplifier
a - zero level detector b - non-zero level detector
Oscillator experiment 1) b is unstable.
16
There are many matching modules in the experimental platform of communication principle. Here, only
the channel analog module, the software radio modulation module and the software radio demodulation
module, the channel coding and interleaving module, and the channel decoding and deinterleaving
module are described. Other optional modules are not introduced.
1 Technical parameter
Working voltage: single phase three line 220 v ,50 Hz,The machine
capacity: < 200 w ,Outlook size: 60×50×40 cm3 , Safety protection:
has the leakage automatic protection device and ground fault
protection, Fault Settings: with fault setting module can satellite
receiver Settings and hardware circuit fault Settings and eliminate.
2 Training project
Training project 1: satellite TV system component, function, composition and principle of knowledge
Training project 2: satellite TV basic function system demonstration operation practice ,
Training project 3: training satellite receiver regulation, set up and operation training ,
Training project 4: antenna parameters calculation and set operation practice ,
Training project 5: training satellite antenna finder positioning operation practice,
Training project 6: satellite receiver fault finding and correct,
Training project 7: connecting cable and F head terminal production operation practice,
Training project 8: line fault judgment and processing operation practice
Training project 9 designated line connection operation practice, Training 10: design and install a simple
application system operation practice
17
2 Technical specification: 1.Work power: single phase three wires 220V±5% 50Hz
2. Whole capacity:<200W 3. Dimension:160×80×190cm3
3 Training program: 1 Recognize components , function, composition, principle of optical transmission
system between equipment 2. Optical transmission system basic function demonstration and operation
3. Optical audio transmission process simulate operation and training 4. Optical video transmission
process simulate operation and training 5. Optical Patchcord and optical fiber transmission system judge
and test operation training 6 Optical fiber module installation operation training 7 Standard wall cabinet
and optical fiber wire shelf installation and training 8 Optical patchcord connection and training 9 Video
capture card, decoder, cloud head, camera connection and training 10 Video monitor software usage
and training
11 Circuit fault judge and operation training 12 Pointed circuit connection training 13 Design and install a
easy applied system training
18
The trainer can be moved or stop convenient . The workbench panel thick is 25mm high density
substrate. There are universal 4 wheels at the bottom of workbench, there are 2 breakers on wheel. The
trainer can be moved or stop convenient.
1.3 Equip tools: (1) power factor meter hanging box 1 piece (2) Three-phase AC filter Hanging box 1
piece (3) Filter inductive /capacitance Hanging box 1 piece (4) Tachometer Hanging box 1 piece (5)
Condensive load Hanging box 1 piece (6) PWM DC speed adjusting Hanging box 1 piece (7) Three-
phase squirrel cage AC asynchronous motor (8) DC motor(9) Three phases transformer module (10)
Bulb load Hanging box 1 piece (11) 4mm safety electrical cable 25 pieces (12) Electrician tool 1 set (13)
Digital multimeter 1 piece
2 Complete training contents: 2.1 DC motor speed control experiment 2.2 three-phase AC motor with
DC generator power generation 2.3 three-phase transformer experiment (1) the principle and
characteristics of the three-phase transformer (2) static test of three-phase transformer (3) star
connection and function of three-phase transformer (4) three-phase transformer triangle connection and
function 3.4 experiment of single-phase bridge rectifier circuit
19
20
1 Feature: (1) Training workbench using aluminum column frame structure, measuring instrument and
practical power built-in integration installation, practical circuit and device adopts hanging box
combinations, each unit with flexible, easy to use, not easy to damage.(2) The experimental circuit and
devices are fully configured and can be used in combination to complete the practical training contents of
various subjects. (3) The training platform has a good safety protection system.
2 Equipped hanging boxes (1)Switch, potentiometer hanging box(ZE3115S-Module-1)1 piece (2)pulse
control unit hanging box (ZE3115S-Module-2)1 piece (3)Field effector drive circuit hanging box
(ZE3115S-Module-3)1 piece (4)Silicon controlled rectifier module hanging box (ZE3115S-Module-4)1
piece (5)Bidirectional thyristor dimmer circuit hanging box (ZE3115S-Module-5)1 piece (6)Load hanging
box (ZE3115S-Module-6)1 piece (7)Semi-controlled bridge thyristor module hanging box (ZE3115S-
Module-7)1 piece 8)Thyristor trigger circuit module hanging box (ZE3115S-Module-8)1 piece (9)Single
junction transistor trigger circuit module hanging box (ZE3115S-Module-9)1 piece (10)Slide rheostat
hanging box (ZE3115S-Module-10)1 piece (11)Diode module hanging box 1(ZE3115S-Module-11)1
piece (12)Voltage ammeter hanging box (ZE3115S-Module-12)1 piece (13)Power transistor, operational
amplifier circuit. hanging box (ZE3115S-Module-13)1 piece (14) DC voltmeter hanging box (ZE3115S-
Module-14)1 piece (15) DC current meter hanging box (ZE3115S-Module-15)1 piece (16) AC voltmeter
hanging box (ZE3115S-Module-16)1 piece (17) AC ammeter hanging box (ZE3115S-Module-17)1 piece
(18)DC motor hanging box (ZE3115S-Module-18)1 piece
3 Experiments which can be finished: 3.1 thyristor trigger circuit experiment: (1) DC voltage trigger
silicon controlled circuit experiment. (2) single junction transistor triggered controlled circuit experiment.
(3) the double pulse control unit can trigger the silicon controlled circuit experiment. 3.2 speed regulation
experiment of dc motor: (1) DC voltage signal trigger field effect tube drive circuit speed regulation
experiment. (2)PWM signal trigger field effect tube drive circuit speed regulation experiment.
21
22
23
Power control panel use aluminum structure metal panel, all close type
boxes structure, it can connect with down shelf together. Training
workbench use aluminum structure. There are universal 4 wheels at the
bottom of workbench, there are 2 breakers on wheel. The trainer can
be moved or stop convenient . The workbench panel thick is 25mm
high density substrate , there is high temperature high pressure anti-fire
treatment process. It equip with three guide rail type drawer, 2 push
and plug cabinet. Input power: three phases, five wires, 380V 50Hz
Dimension: 1600mm×800mm×1300mm
1 Power control panel
(1) Three phases, five wires power input, it has been tested by leakage breaker
control, it has emergency stop button, you can cut off electricity when emergency.
Control panel supply power indicator, European type power output sockets, and
safety type output interface (3)It equipped AC, with short circuit protection function.
2 Component included
One single-phase transformer (2)One single phase isolating transformer (3)One single phase ring
shape transformer (4)One single self coupling transformer (5)One three phases transformer (6) U
shape and I shape Silicon Steel (7) EI shape and I shape Silicon Steel(8) One load resistor box (9)
4MM SAFETY electrical cables 25 eas Supply English user manual
3 Experiment available 3.1 Single phase transformer experiments (1) Single phase transformer
static test (2) Single phase transformer empty load and load characteristic (3) Single phase transformer
voltage short and current short circuit test (4) Single phase ring shape transformer empty load and load
characteristic test (5) Single phase ring shape transformer short circuit voltage and short current test
3.2 Single phase self-coupling transformer experiments (1) Self-coupling transformer principle
features (2) Self-coupling transformer static test (3) Self-coupling transformer operation and function
features (4) Self-coupling transformer load testing features 3.3 Three phases transformer experiments
(1) Three phases transformer principle features (2) Three phases transformer static test (3) Three
phases transformer star connection and function (4) Three phases transformer delta connection and
function
3.4 Transformer comprehensive training (1) Transformer installation and circuit wire check
(2) Winding DC cold resistor test(3) Insulation resistor test (4) Transformer over load experiment test
(5) Transformer empty load experiments (6) Transformer temperature rise experiments (7) Transformer
load experiments Supply English user manual.
24
one current meter, one power meter, one non power meter. (3)It equipped with indicator, Europe power
plug output, safety output sockets. (4)Inner AC 220V current output, DC 220V wound power, DC 0-220V
continuous adjustable DC armature power, with short circuit protection function.
2 Component included: (1) Series-excited DC machines (2) Parallel wound DC machines one unit (3)
Parallel wound DC generator one unit (4) DC compound generator (5) DC servo motor one unit (6) DC
servo motor drive controller one unit (7) Motor coupling 3 sets (8) Load resistor box one unit (9) 4mm
safety Electrical cables 20 pieces
3 Training content :
3.1 Series wound DC machines experiments (1) Motor function and transmission set test (2) Motor
technical parameter static test (3) Motor control circuit connection and function (4) Motor function
technical parameter test 3.2 Parallel wound DC machines (1) Motor function and transmission set test
(2) Motor technical parameter static test (3) Motor control circuit connection and function (4) Motor
function technical parameter test 3.3 DC compound generator start and stop control (1) Motor
function and transmission set test (2) Motor technical parameter static test (3) Motor control circuit
connection and function (4) Motor function technical parameter test 3.4 DC servo motor experiment (1)
Motor function and transmission set test (2) Motor technical parameter static test (3) Motor control circuit
connection and function (4) Motor function technical parameter test (5) Motor speed adjust control 3.5
Motor comprehensive training (1) Motor installation and circuit check and test (2) Winding DC cold
resistance test (3) Insulation resistor test (4) Motor speed exceed experiments (5) Motor empty
experiments (6) Motor temperature rise experiments (7) Motor stalling experiments (8) Motor load
experiments
Supply English user manual
25
1 Training workbench
Training table adopt aluminum pillar support, universal belting leather at the bottom of the brake, flexible
movement and positioning. Desktop with 25 mm thick substrate with high density, high temperature and
high pressure on the surface of fire prevention board to stick a face processing, equipped with three
drawer guide rail type 2, bottom cabinet two sliding door type, firm structure, the beauty is generous.
2 Power box
1) Three-phase, five wires power input, the residual current circuit breaker control, a stop control button,
an emergency stop button circuit breaker to cut off the power supply.
(2) supporting the voltmeter, ammeter, frequency tables, power factor meter, phase sequence indicator,
and the electronic tachometer.
(3) the configuration and secure power light, European-style outlet power output terminal.
(4) Built-in multiple output voltage DC regulated power supply, with short circuit protection function.
3 Main experiment components set
(1) Three-phase salient pole synchronous generator (with special base) (2) Shunt DC motor (with special
base) (3) Three-phase asynchronous motor with speed measuring unit (4) Load cases (resistor, capacitor,
inductor) (5) Digital multimeter (6) 4mm safety electrical cable
4 Training projects
1)3-phase salient pole generator characteristic experiment
2)3-phase salient pole generator control circuit experiment
3)3-phase salient pole synchronous generator control experiment
4)3-phase salient pole generator load test
5)3-phase salient pole generator running characteristic experiment
Supply English user manual.
26
(10) The contactor interlock circuit control unit (11) Slip ring starter motor rotor unit (12) Start capacitor
units(With discharge resistance) (13) Permanent magnet synchronous motor controller unit (14) Button,
lamp units (15) 4mm safety cable
2 Training content 2.1 Single phase capacitor electro experiment (1) Single phase capacitor static
test (2) Single phase capacitor principle, feature and function test (3) Single phase capacitor start
function control (4) Single phase capacitor double value capacitor switching control 2.2 Single phase
mask pole motor experiment (1) Single phase mask pole motor static test (2) Single phase mask pole
motor principle, feature and function test (3) Single phase mask pole motor start function control 2.3
Three-phase asynchronous double speed motor experiment (1) Three-phase asynchronous double
speed motor static test (2) Three-phase asynchronous double speed motor principle, feature and
function test (3) Three-phase asynchronous double speed motor high speed and low speed function
control (4) Three-phase asynchronous double speed motor speed convert(change speed)control 2.4
Three phase squirrel-cage asynchronous motor experiment (1) Three phase squirrel-cage
asynchronous motor principle and feature (2) Three phase squirrel-cage asynchronous motor static test
(3) Three phase squirrel-cage asynchronous motor function test (4) Three phase squirrel-cage
asynchronous motor Positive and negative conversion to control (5) Three phase squirrel-cage
asynchronous motor star-triangle start control (6) Three phase squirrel-cage asynchronous motor
thermal delay overcurrent relay control (7) Time relay control three phase squirrel-cage asynchronous
motor start and delay stop 2.5 Three-phase winding type slip ring motors experiment (1) Three-
phase winding type slip ring motors principle and feature (2) Three-phase winding type slip ring motors
static test (3) Three-phase winding type slip ring motors connection and function (4) Three-phase
winding type slip ring motors function specification test (5) Three-phase winding type slip ring motors
start and stop control (6)Slip ring rotor starter application 2.6 Three-phase ac permanent magnet
synchronous motor experiment (1) Three-phase ac permanent magnet synchronous motor principle
and feature (2) Three-phase ac permanent magnet synchronous motor static test (3) Three-phase ac
permanent magnet synchronous motor connection and function (4) Three-phase ac permanent magnet
synchronous motor start control experiment, Experiment Supply English user manual.
27
2 Training workbench: Training workbench use aluminum structure. There are universal 4 wheels at
the bottom of workbench, there are 2 breakers on wheel. The trainer can be moved or stop convenient .
The workbench panel thick is 25mm high density substrate , there is high temperature high pressure
anti-fire treatment process. It equip with three guide rail type drawer, 2 push and plug cabinet. The
structure is sound and reliable, outlook is beautiful.
3 Main equipped hanging box type
(1) Industrial class three phase AC inverter(with operate panel)
(2) Inverter transistor brake unit, equip with brake resistor
(3) Three phases asynchronous motor with speed test unit
(4) Sensor analogue signal combination unit
(5) Digital multimeter(with RS232 interface and PC display software)
(6) 4mm safety electrical cable
(7) Electrician tools
4 Training project
Inverter control training project, Inverter parameter setting and frequency adjust experiment,
Inverter speed control circuit, Inverter brake unit brake experiment,
Inverter drive AC motor loader experiment, Inverter PID parameter adjustment experiment,
Inverter output open loop control speed experiment,
Inverter circuit sensor control application experiment, Inverter multi speed run experiment
Inverter program run experiment Instant power off start experiment,
Inverter speed position system experiment,
Inverter close loop system experiment
With English use manual
28
(2)DC servo motor3)DC servo motor controller (4)DC motor (5)control type self synchronous motor
transmitter (6)control type self synchronous motor receiver(7)Photoelectric linear position sensor (8)Belt
transmission line actuator(with Tension Roller and weight)2 units (9)Multi meter one unit (10)Electrician
tools (11)4mm safety Electrical cables (12) Function generator
3 Training content
3.1 DC step motor experiment (1) DC step motor static test (2) DC step motor and drive principle
characteristics and running test (3) DC step motor open loop operation control (4) DC step motor closed-
loop operation control (5) DC step motor load running test (6) DC step motor speed feedback control
3.2 DC motor experiment (1) Principle of DC motor characteristics (2) DC motor static test (3) DC motor
of running test (4) DC motor of open loop operation speed regulation control (5) DC motor speed
regulation control closed loop operation (6) DC motor operation loading test (7) DC motor speed
feedback control
3.3 DC servo motor experiment(1) Principle of DC servo motor characteristics (2) DC servo motor
static test (3) DC servo motor connection and operation (4) DC servo motor operation parameters
measurement (5) DC servo motor drive controller principle and operation characteristics (6) DC servo
motor braking characteristics (7) DC servo motor open loop operation characteristics (8) DC servo motor
closed-loop operating characteristics (9) DC servo motor speed control
3.4 Auto synchro motor experiment(1) Auto synchro motor principle character (2) Control type Auto
synchro motor static test(3) Control type Auto synchro motor function test (4) Auto synchro motor angle
change test
3.5 Mechatronics transmission comprehensive experiment (1) Belt transmission mechanism output
torque test (2) Belt transmission mechanism of linear displacement distance control test (3) Belt
transmission mechanism of loading test (4) Level 2 belt transmission mechanism of synchronous
operation control (5) Level 2 belt transmission mechanism of servo operation control (6) Using
electromagnetic photoelectric linear displacement sensor for distance measurement
29
a. Five line of three-phase power input, the residual current circuit breaker control, a stop control button,
an emergency stop button circuit breaker to cut off the power supply.
b. Configuration and secure power light, European-style outlet power output terminal. c. Configuration of
AC electrical machine is special protection switch, built-in ac power supply, with short circuit protection
function. Power console use metal sheet.
2.2 Training workbench: Training workbench use anti fire panel, it’s sound and beautiful.
2.3 Main components: a. Step motor with controller b. AC servo motor with controller c. DC servo motor
with controller d. Spindle reducer, ratio 40:1 e. Angular position sensor, electrical angle 345 degree f.
Incremental rotary encoder unit, 1024 pulse g. Linear movement unit h.4mm safety cable 25 eas i.
Frequency meter: to test electrical machines electric work power only.
3 Training content
3.1 AC servo motor experiment: a. AC servo motor static test b. AC servo motor principle features and
function test c. AC servo motor start function control d. AC servo motor servo position control e. AC servo
motor angular displacement f. AC servo motor linear displacement g. AC servo motor slow down
positioning control
3.2 DC servo motor experiment: a. DC servo motor static test b. DC servo motor principle features and
function test c. DC servo motor start function control d. DC servo motor servo position control e. DC
servo motor angular displacement f. DC servo motor linear displacement h. DC servo motor slow down
positioning control
3.3 Step motor experiment
a. Step motor static test b. Step motor principle features and function test c. Step motor open loop control
d. Step motor close loop control e. Step motor angular displacement f. Step motor linear displacement g.
Step motor slow down positioning control
3.4 Motor loader experiment: (1) Step motor loader feature experiment (2) AC servo motor loader
feature experiment(3) DC servo motor loader test feature experiment
30
3 Training content
3.1 Single phase capacitive motor experiments: (1) Single-phase capacitor motor static test (2) The
principle of single-phase capacitor motor characteristics and run test (3) Single-phase capacitor motor
start and stop control (4) Single-phase capacitor motor centrifugal switch control
3.2 Three phase asynchronous motor experiments: (1) Three phase asynchronous motor principle
and features (2) Three phase asynchronous motor static test (3) Three phase asynchronous motor
function test (4) Three phase asynchronous motor forward and reverse control (5) Three phase
asynchronous motor star and delta control (6) Three phase asynchronous motor contactor control
3.3 Three phase winding motor experiments: (1) Three phase wind asynchronous motor principle and
features (2) Three phase wind asynchronous motor static test (3) Three phase wind asynchronous motor
connect and function (4) Three phase wind asynchronous motor function technical parameter setting
(5) Three phase wind asynchronous motor start and stop control
3.4 Three phase wind synchronous motor experiments: (1) Three phase wind synchronous motor
principle and features (2) Three phase wind synchronous motor static test (3) Three phase wind
synchronous motor connect and function (4) Three phase wind synchronous motor function technical
parameter setting (5) Three phase wind synchronous motor start and stop control
3.5 Three phases double speed motor experiments: (1) Three phases double speed motor principles
and features (2) Three phases double speed motor static test (3) Three phases double speed motor
connect and function (4) Three phases double speed motor technical parameter function and test (5)
Three phases double speed motor start and stop control (6) Three phases double speed motor high
speed and low speed function (7) Three phases double speed motor speed change control
3.6 Electrical machines comprehensive experiments (1) Electrical machines load features test (2)
Electrical machines function technical parameter test (3) Electrical machines electric technical parameter
test Supply English user manual
31
(3) Three-phase asynchronous two-speed motor high speed and low speed run control (4) Three-phase
asynchronous two-speed motor speed convert(speed change) control 1.3 Three phase squirrel cage
induction motor experiment (1) three phase squirrel cage induction motorprinciple (2) three phase
squirrel cage induction motor static test (3) three phase squirrel cage induction motor run test (4) three
phase squirrel cage induction motor positive and negative rotation control (5) three phase squirrel cage
induction motorstar-triangle start control (6) three phase squirrel cage induction motorheat delayed
overcurrent relay control (7) Time relay control three phase squirrel cage induction motor delay start and
delay stop 1.4 Three phase wind asynchronous motor experiment (1) Three phase wind
asynchronous motorprinciple (2) Three phase wind asynchronous motor static test (3) Three phase
wind asynchronous motorconnection and run (4) Three phase wind asynchronous motorrun parameter (5)
Three phase wind asynchronous motor start and stop control (6) Slip-ring rotor starter training application
1.5 Three-phase AC permanent magnet synchronous motor experiment (1) Three-phase AC
permanent magnet synchronous motorprinciple (2) Three-phase AC permanent magnet synchronous
motor static test (3) Three-phase AC permanent magnet synchronous motorconnection and run (4)
Three-phase AC permanent magnet synchronous motorstart control experiment (5) Three-phase AC
permanent magnet synchronous motor speed adjust experiment (6) Three-phase AC permanent magnet
synchronous motorclose loop control experiment 1.6 DC compound generator experiment (1) DC
compound generator run function and transmission group test (2)DC compound generator technical
parameter static test (3) DC compound generator motor control circuit connection and function (4) DC
compound generator run function and technical parameter test 1.7 Single-phase
transformerexperiment (1) single-phase transformer static test (2) single-phase transformerempty and
load feature test (3) single-phase transformer short circuit voltage and current test (4) single-phase ring
type transformerempty load and load feature test (5) single-phase ring type transformer short circult
voltage and short circuit current test 1.8 Three-phase transformer experiment (1) Three-phase
transformer principle (2) Three-phase transformer static test (3) Three-phase transformer start
connection function (4) Three-phase transformer triangle connection function
32
9. Three-phase overload insurance 10. Three-phase and single-phase power output terminals
11. socket 3.3 matching module (1) Inverter hanging box (2) button module (3) Analog module
(4) Motor module (plus rotary encoder)
3 Experiment and training content: 3.1 Three-phase squirrel cage asynchronous motor inverter control
experiment (BOP control) 3.2 Three-phase squirrel cage asynchronous motor inverter control experiment
terminal control (external button combined with analog control) 3.3 Three-phase squirrel cage
asynchronous motor inverter control experiment (multi-speed control) 3.4 Three-phase squirrel cage
asynchronous motor speed measurement experiment
ZE3124 Controlling and Switching Trainer
1 Technical parameter
(1) Input power: three phase, five wires, 380V±10% 50Hz (2)
Dimension: 1600mm×800mm×1300mm (3) Whole capacity:<
2.0KVA (4) Weight: <200kg
2 Component included
(1)Single-phase capacitor motor(With Centrifugal switch) 1 unit
(2)Three phase squirrel-cage asynchronous motor 1 unit (3)Three-phase winding type slip ring motors 1
unit (4)Time relay control unit (5)Thermal delay overcurrent relay control unit (6)Y-△ commutation switch
control unit (7)The contactor interlock circuit control unit (8)Slip ring starter motor rotor unit (9)Start
capacitor units(With discharge resistance) (10)Button, lamp units (11)4mm safety cable 25 pieces
3 Training content
3.1 Single phase capacitor electro experiment
3.2 Three phase squirrel-cage asynchronous motor experiment
3.3 Three-phase winding type slip ring motors experiment
Supply English user manual
33
(1) Step motor dynamic model experiments (2) Step motor single time trigger mode experiment (3)Step
motor automatic round trip mode (4)Step motor single time round trip mode experiment (5)Step motor
round trip run mode experiment according to set times
34
1 Technical parameter
(1) Input power: single phase, three wires, 380V±10%
50Hz(2) (2) Dimension: 1600mm×800mm×1300mm
(3) machine capacity: < 2KVA
(4) weight: < 290kg
2 Product consist of
(1)Single-phase capacitor start motor(With Centrifugal switch)
(2)Single phase mask pole motor
(3)Three-phase asynchronous double speed motor
(4)Three phase squirrel-cage asynchronous motor
(5)Three-phase winding type slip ring motors
(6)Three-phase ac permanent magnet synchronous motor (7)Time relay control unit
(8)Thermal delay overcurrent relay control unit
(9)Star triangle commutation switch control unit
(10)The contactor interlock circuit control unit
(11)Slip ring starter motor rotor unit
(12)Start capacitor units(With discharge resistance)
(13)Permanent magnet synchronous motor controller unit
(14)Button, lamp units
(15)4mm safety cable
3 Training content:
3.1 Single phase capacitor start motor electro experiment
3.2 Single phase mask pole motor experiment
3.3 Three-phase asynchronous double speed motor experiment
3.4 Three phase squirrel-cage asynchronous motor experiment
3.5 Three-phase winding type slip ring motors experiment
3.6 Three-phase ac permanent magnet synchronous motor experiment
3.7 DC compound generator
3.8 Single phase transformer experiments
3.9 Three phases transformer experiments
35
36
37
(11) Star Delta Starter (12) Grid check module (13) Synchronous inspection relay module (14) Voltage
transformer module (2 pieces) (15) Rectifier module (16) Voltage and current meter module (17)
Indicator module (18) Button module (19) Magnetic powder brake control module (20) Three-phase
multi-function meter module (21) AC contactor module (2 pieces) (22) Time relay module (23) Speed
display instrument module (24) Torque speed display instrument module (25) Rotary encoder (26) DC
shunt motor (0.75 kW, 220V, 1500 rpm) (27) DC series motor (0.75 kW, 220V, 1500 rpm) (28) DC
compound motor (0.75 kW, 220V, 1500 rpm) (29) Three-phase squirrel cage asynchronous motor
(220/380v 50Hz, 1500rpm, 0.75 kW) (30) Three-phase two-speed asynchronous motor (380V 50Hz, 0.75
kW, 1500 and 3000 rpm) (31) Synchronous reversible motor (220/380v 50Hz, 1500rpm 0.75 kW) (32)
Single-phase capacitor motor (230v/50hz, 1500rpm, 0.75 kW) (33) AC/DC universal motor (DC and AC
230V 50Hz, 1500 rpm, 0.75 kW) (34) Three-phase wound slip ring motor (0.75 kW, 220V, 1500 rpm) (35)
Torque measuring device (36) Phase detecting device (37) Tachometer (38) digital multimeter 1 piece
(39) electrical cable 25 pieces
3 Experimental content: Experiment 1 Run-in DC motor operation control experiment
Experiment 2 Series-excited DC motor operation control experiment
Experiment 3 Connection experiment of compound excitation DC motor control circuit
Experiment 4 Three-phase squirrel-cage asynchronous motor star-delta step-down start-up experiment
Experiment 5 Start-up experiment of three-phase wound asynchronous motor rotor series resistance
Experiment 6 Three-phase AC excitation synchronous motor running experiment
Experiment 7 Three-phase two-speed motor running experiment Experiment 8 Single-phase capacitor
motor running experiment Experiment 9 AC and DC universal motor operation control experiment
Experiment 10 Rejecting the motor running control experiment
Experiment 11 Torque, Rotational Speed, and Power Measurement Experiments of Three-Phase AC
Asynchronous Motors
38
2 Features
(1) The training platform adopts an aluminum profile column frame structure with a universal wheel at the
bottom for flexible movement. The measuring instrument and the training power supply are integrated
and installed, which is easy to use and not easy to damage.
(2) The motor is fully equipped and can be used in combination to complete the training content of
various courses.
(3) The training platform has a good security protection system.
3 Contained components: (1) Single-phase capacitor motor 1 piece (2) DC shunt motor 1 piece
(3) Three-phase two-speed motor 1 piece (4) Three-phase squirrel cage asynchronous motor 1 piece
(5) Three-wire wound slip ring motor 1 piece (6) Three-phase AC permanent magnet synchronous motor
1 piece (7) Time relay control unit (8) Thermal delay overcurrent relay control unit (9) Contactor Interlock
Circuit Control Unit (10) Slip ring motor rotor starter unit (11) Start capacitor unit (12) Permanent magnet
synchronous motor controller unit (13) Single-phase transformer 1 piece (14) Three-phase transformer 1
piece (15) Motor control module 1 piece (16) Button, indicator unit
4 Experiment list
4.1 Single-phase capacitor motor related experiments
4.2 Three-phase asynchronous two-speed motor related
4.3 Three-phase squirrel cage asynchronous motor related experiments (
4.4 Three-phase wound motor related experiments
4.5 Three-phase AC permanent magnet synchronous motor related experiments
4.6 Compound excitation DC generator related experiments
4.7 single phase transformer related experiments
4.8 Three-phase transformer related experiment
39
2.2 DC 48V power module (1) Single-phase power input.(2) Configuration with power indicator, two
groups of DC 48V safety power output terminals.(3) The power supply is equipped with a fuse to
facilitate safety. 2.3 AC voltage meter 2.4 AC voltage meter 2.5DC voltage meter 2.6 DC current meter
2.7 Tachometer(2 sets) 2.8 Inverter 2.9 DC driver 2.10 AC Driver 2.11 Limit protect module When the
motor is over the range, the indicator lights up and the power supply to the driver is cut off.
2.12 DC servo speed control module Speed knob: clockwise increase, counterclockwise decrease
2.13 AC servo speed control module Speed knob: clockwise increase, counterclockwise decrease
2.14 DC 24V power module Convert AC 220V power to DC 24V power 2.15 Encoder line
2.16 AC servo control line 2.17 AC servo motor encoder cable 2.18 AC servo motor power cord
2.19 DC servo Uart line 2.20 DC servo control signal line 2.21 DC servo motor power cord
2.22 Three-phase asynchronous motor
3 Experiment list: AC servo motor control
40
1 Performance parameters
(1) Input power: three-phase five-wire system
380V±10% 60Hz
(2) Dimensions: 1600mm × 800mm × 1800mm
(3) Machine capacity: <2KVA
(4) Weight: <200kg
(5) Working conditions: ambient temperature -
10 °C ~ +40 °C Relative humidity <85% (25 °C)
2 Technical Data
2.1 Training table
The training table is supported by aluminum profiles and the universal wheel is attached to the bottom. It
can be moved flexibly and can be adjusted independently according to the ground conditions. The
desktop is made of 25mm thick high-density substrate, and the surface is treated with high-temperature
and high-pressure fireproof board. The structure is firm and the whole is simple and generous.
2.2 Power Box Introduction
1. Total power supply - 4P leakage circuit breaker 2. AC380V three-phase AC output unit 3. Emergency
stop unit 4. DC speed control module 5. Brake controller module 6. Intelligent display table straight
module 7. European socket
2.3 matching module
(1) Motor module The training device is equipped with a DC compound motor and a three-phase squirrel
cage asynchronous motor. As shown below. (2) Torque speed transmitter, magnetic powder brake
module The training device is equipped with a torque speed transmitter and a magnetic powder brake.
Use the brake controller to adjust the torque of the magnetic powder brake, connect the intelligent
display instrument, display the speed, torque and power in real time on the intelligent display device;
connect the data acquisition module to display the speed, torque and power in real time on the computer
software. Torque speed transmitter, magnetic powder brake module
3 Training content
3.1 compound excitation DC motor experiment
3.2 Motor torque, speed, power measurement experiment
3.3 Three-phase squirrel cage asynchronous motor experiment
41
2.2 Power Control Screen Configuration: (1) Three-phase five-wire power input, controlled by leakage
circuit breaker, with emergency stop control button. In emergency, press the emergency stop button
breaker to cut off the power.(2) It is equipped with a power indicator, a power outlet, and a safety power
output terminal.(3) Configure the AC motor special protection switch, built-in AC power supply, with short
circuit protection.(4) Built-in AC power supply with short circuit protection.
2.3 Companion devices: (1) One DC shunt motor (2) 1 set of three-phase asynchronous motor (3) Time
relay control unit (4) Thermal delay overcurrent relay control unit (5) Contactor interlock circuit control
unit(6) Button module (7) DC voltage measurement module (8) AC voltage measurement module
(9) DC current measurement module (10) AC current measurement module
3 Experiment list
3.1 Three-phase squirrel cage asynchronous motor related experiments
3.2 Mutual excitation DC generator related experiments
ZE3314 Motion Control Trainer (DC motor)
1 Performance parameters
(1) Dimensions: 600mm × 400mm × 300mm (2)
Weight: <50kg (3) Working conditions: ambient
temperature -10 °C ~ +40 °C Relative humidity
<85% (25 °C)
2 Experiment list
Experiment 1 Sensor test Experiment 2 DC motor
running test
42
1 Technical parameter
(1) Input power: single phase, three wires, 220V±10%
50Hz (2) Dimension: 1600mm×800mm×1800mm (3)
Whole capacity:<2.0KVA (4) Weight: <200kg
2 Product consist of 2.1 Power control panel Power
control panel use aluminum structure metal panel, all
close type boxes structure
2.2 Training workbench: Training workbench use
aluminum structure.
There are universal 4 wheels at the bottom of workbench, there are 2 breakers on wheel. The trainer can
be moved or stop convenient. The workbench panel thick is 25mm high density substrate , there is high
temperature high pressure anti-fire treatment process. It equip with three guide rail type drawer, 2 push
and plug cabinet. The structure is sound and reliable, outlook is beautiful.
2.3 Power control panel: (1)Single phase, three wire power input, it has been tested by leakage
breaker control, it has emergency stop button, you can cut off electricity when emergency. (2)Control
panel has two point type voltage meter, one current meter, one power meter, one non power meter.
(3)It equipped with indicator, Europe power plug output, safety output sockets. (4)Inner AC 220V current
output, DC 220V wound power, DC 0-220V continuous adjustable DC armature power, with short circuit
protection function.
2.4 Component included: (1) Sky tower light simulation training(2) Traffic light test simulation training(3)
Various liquid mixing simulation training(4) Water level simulation training towers(5) Mail sorting
simulation training(6) Motor control simulation training(7) Responder simulation training(8) Automatic
feeding loading simulation training(9) Automatic packing line simulation training (10) Machining center
simulation training(11) Feed car simulation training(12) Robot simulation training(13) Elevator control test
simulation training(14) Vending machine simulation training (15) Temperature automatic control (16) Multi
meter(17) Teaching edition software for PLC program(not paid edition).(18)English user manual With
teaching edition software, means not licensed edition, crack edition)
43
4.Analog quantity input and output connection training (it requires analog module) 5.Basic instruction
experiment 6.Timer and counter instruction experiment 7.Shifting register instruction experiment
8.Set/reset and pulse instruction experiment 9.Jump instruction experiment 10.Common function
instruction experiment 11.Analog quantity input and output programming training (it requires analog
quantity module)
(6)Automatic mail sorting training (7)vending machine simulates the training(8)elevator simulation
training (9)Traffic light simulation training
(10)Automatic forming machine training(11)electroplating production line simulation training
(12)Automatic washing machine training(13)Motor forward and reverse simulation training.
44
Power control box takes aluminum structure, box type close structure, connect with training frame.
2.2 Configuration for power control box: (1), Single-phase three-wire power input ,the residual
current circuit breaker control, a stop control button, an emergency stop button circuit breaker to cut
off the power supply. (2) the voltmeter and ammeter do output instructions, equipped with 0 to 10 v
and 4-20 ma signal generator.(3) the configuration power light, European-style power input plug and
secure power supply output terminals.(4) built-in ac power supply, with short circuit protection
function.
2.3 Hanging box module: This module can satisfy students do a variety of different experiment,
each test module is made, according to a standard size when installing the first module in the
aluminum casting of beam in top insert card slot, and then aim the module bottom tank under push
down, the module card on the beam. Hanging box module as shown.
3 Equip components
(1) Siemens S7-1200 PLC module and I/O modules hanging box 1 piece
(2) Temperature control box 1 piece
(3) Elevator hanging box 1 piece
(4) Traffic lights hanging box 1 piece
(5) Mechanical and electrical load hanging box 1 piece
(6) Some 2mm safety electrical cable
(7) 4mm safety electrical cable 3 cables
4 Experiment list
(1) Temperature control simulation training
(2) Traffic lights experiment simulation training
(3) Elevator control practice
(4) Mechanical and electrical load simulation training
(5) Siemens S7-1200 PLC programming practice
45
1Performance parameters
(1)Dimensions: 1200mm × 430mm × 375mm
(2) Weight: <50kg
(3) Working conditions: ambient temperature -10 °C ~
+40 °C Relative humidity <85% (25 °C)
2 Experiment List
Experiment 1 Sensor test
Experiment 2 DC motor test
Experiment 3 Elevator operation test
1 Performance parameters
(1) Dimensions: 600mm × 400mm × 200mm (2)
Weight: <50kg (3) Working conditions: ambient
temperature -10 °C ~ +40 °C Relative humidity
<85% (25 °C)
2 Experiment list: Traffic light simulation
46
47
2 Product consist of
2.1 Power control panel: Power control panel use aluminum structure metal panel, all close type boxes
structure
2.2 Training workbench: Training workbench use aluminum structure. There are universal 4 wheels at
the bottom of workbench, there are 2 breakers on wheel. The trainer can be moved or stop convenient .
The workbench panel thick is 25mm high density substrate, there is high temperature high pressure anti-
48
49
(7) PLC07 Elevator control system (8) PLC08 Automatic washing machine control system (9) PLC09
Motor forward and reverse control (10) PLC10 Traffic light control (11) PLC11 Automatic water tower
water level control (12) PLC12 Television transmission tower (13) PLC13 Automatic goods delivery and
loading system (14) PLC14 Relay control experiment (15) PLC 15 Siemens 200 smart PLC (16) PLC16
Button box (17) 2mm safety electrical cable (18) Digital multimeter
3 Experiment which can be finished
(1) Motor forward and reverse simulation training.
(2) Television transmission tower simulation
(3)Traffic light control simulation training
(4) Automatic goods delivery and loading system simulation
(5) Automatic water tower water level control simulation
(6) Automatic molding machine system simulation
(7) Various liquid automatic control system simulation
(8) Automatic punching machine control system simulation
(9) Elevator control system simulation
(10) Automatic mail sorting system simulation
(11) Automatic washing machine control system simulation
(12) Plating control system simulation
(13) Automatic vending machine system simulation
(14) PLC basic instructions training( it doing through experiment 1 to 13)
(15) Relay control experiment ( it doing through experiment 1 to 13)
(16) Software simulation control( it doing through experiment 1 to 13)
50
The training frame is supported by aluminum profile column, which has firm structure, beautiful
appearance and convenient desktop operation.
2.2 Power Module
The power module is AC220V input, DC24V power supply, and power plug wire, which is safe and
convenient.
2.3 button module
The module contains eight lamp buttons, each with a normally closed contact and a normally open
contact, six of which are self-resetting buttons and the other two are self-locking buttons. A plc
digital signal can be input for plc.
2.4 relay module
The module contains three relays, each is with two normally open contacts and two normally closed
contacts. It can be used as an actuator for plc.
2.5 PLC module
The module contains the Siemens CPU1212C DC/DC/DC, SM1223 module and SM1232 module. It
contains 24 digital inputs, 22 thyristor (DC24v) outputs, 2 analog inputs and 2 analog outputs.
2.6 touch screen module
The module contains a MCGS 7-inch color touch screen for monitoring the PLC.
2.7 Equipped components
(1) Network Cable 1 piece (2) PLC programming software CD 1 piece (3) touch screen
programming software 1 piece (4) 5A fuses 10 pieces (5) yellow indicator light 1 piece, green
indicator 1 piece, red indicator 1 piece (6) English manual 1 pieces (7) 2mm safety electrical cable
25 pieces (8) 2mm safety sockets 3 pieces
3 Training content
(1) plc programming training (2) Touch screen programming training (3) Plc and touch screen
communication training (4) Computer and touch screen communication training
(5) Touch screen control plc training (6) Touch screen monitoring plc state training
51
52
2.1 Module digital input The module contains 12 digital inputs, each with a switch analog digital input
state. 2.2 Module Relay Output The module contains 8 relay outputs, each with an LED indicator to
indicate the relay output status. 2.3 Module Analog Input The module contains 4 analog input points for
voltage analog or current analog signals. 2.4 Module analog output The module contains 2 analog
input points for outputting analog signals. 2.5 Total power supply The module power supply is AC220V
input, and the built-in DC24V power supply supplies power to the PLC. Power outlets with switches and
fuses are safe and reliable. 2.6 PLC module The module contains PLC module using Siemens SMART
SR20 module and EM AM06 module, providing 12 digital input, 8 relay output, 4 analog input, 2 analog
output, support memory card. 2.7 PLC DC 24V output The module contains two sets of PLC output
DC24V power supplies. 2.8 PNP type metal sensor (2 sets) The module contains two sets of PNP-type
metal sensors that, when metal is detected, emit a signal that can be used as a PLC input signal.
2.9 DC24V Relay (2 sets) The module contains two sets of DC24V relays (2 sets), which can be used
as PLC external actuators. 2.10 voltage analog signal DC 0-10V output The module contains a set of
DC 0-10V DC voltage analog signal, which can be used as PLC DC voltage analog input signal.
2.11 Current Analog Signal DC 4-20mA Output The module contains a set of DC 4-20mA DC current
analog signal, which can be used as PLC DC current analog input signal.
2.12 Companion devices (1) USB communication line 1 piece (2) PLC programming software CD 1
piece (3) 10A fuses 10 pieces (4) 1 yellow indicator light, 1 green indicator light, 1 red indicator light (5)
English manual 1 piece (6) 2mm test line 25 pieces (7) 2mm terminals 3 pieces
3 Can complete the training content
(1) Computer and PLC communication and programming training
(2) Computer monitoring PLC status training
(3) PLC analog input training
53
(5): Module relay output (6): PLC module (7): PLC DC 24V output(8): Current analog signal DC 4-20mA
output
2.1 Module digital input The module contains 14 digital outputs, each with a switch analog digital input
status and an LED indicator indicating the digital input status.
2.2 Module analog input The module contains 2 analog input points for voltage analog or current
analog signals.
2.3 Voltage analog signal DC 0-10V output The module contains a set of DC 0-10V DC voltage analog
signal, which can be used as PLC DC voltage analog input signal.
2.4 Total power supply The module power supply is AC220V input, and the built-in DC24V power
supply supplies power to the PLC. Power outlets with switches and fuses are safe and reliable.
2.5 Module relay output The module contains 10 relay outputs, each with an LED indicator to indicate
the relay output status.
2.6 PLC module This module contains the Siemens CPU1214C DC/DC/RLY and CM1241 modules. A
total of 14 digital inputs, 10 thyristor (DC24v) outputs, and 2 analog inputs have been introduced to the
module panel.
2.7 PLC DC 24V output The module contains two sets of PLC output DC24V power supplies.
2.8 Current analog signal DC 4-20mA output The module contains a set of DC 4-20mA DC current
analog signal, which can be used as PLC DC current analog input signal.
2.9 Companion devices (1) Communication line 1piece (2) PLC programming software CD 1 piece (3)
10A fuses 10 pieces (4) 1 yellow indicator light, 1 green indicator light, 1 red indicator light (5) English
manual 1 piece (6) 2mm test line 25 pieces (7) 2mm terminals 3 pieces
3 Can complete the training content (1) Computer and PLC communication training (2) PLC
programming training (3) Computer monitoring PLC status training (4) PLC analog input training
54
55
2 Product composition 1: CPU1215c module digital input 2: Module analog input 3: SM1234 module
analog input 4: Total power supply 5: Module relay output 6: PLC module 7: SM1234 module analog
output 8: PLC DC 24V output
2.1 Module digital input The module contains 14 digital outputs, each with a switch analog digital input
status and an LED indicator indicating the digital input status.
2.2 Module analog input The module contains 6 analog input points for voltage analog or current
analog signals.
2.3 Total power supply The module power supply is AC220V input, and the built-in DC24V power
supply supplies power to the PLC. Power outlets with switches and fuses are safe and reliable.
2.4 Module relay output The module contains 10 relay outputs, each with an LED indicator to indicate
the relay output status.
2.5 PLC module The module contains the Siemens CPU1214C DC/DC/RLY, CM1241 module and
CM1234 module. A total of 14 digital inputs, 10 thyristor (DC24v) outputs, 6 analog inputs, and 2 analog
outputs have been introduced to the module panel.
2.6 Module analog output
The module contains 2 analog input points for outputting analog signals.
2.7 PLC DC 24V output
The module contains two sets of PLC output DC24V power supplies.
2.8 Companion devices
(1) cable1 piece (2) PLC programming software CD (3) Wired USB network card 1 piece (4) 10A fuses
10 pieces (5) 1 yellow indicator light, 1 green indicator light, 1 red indicator light (6) English manual 1
piece (7) 2mm test line 25 pieces (8) 2mm terminals 3 pieces
3 Can complete the training content
(1) Computer and PLC communication training (2) PLC programming training (3) Computer monitoring
PLC status training (4) PLC analog input and output training
56
1 Performance parameters
(1) Input power: three-phase four-wire AC380V ± 10%
50Hz (2) Overall dimensions: 1800X1760X700mm (3)
Machine capacity: <1.5KVA (4) Weight: <120kg (5)
Working conditions: ambient temperature -10 ℃ ~ +
40 ℃ relative humidity < 85% (25 ℃) (6) Safety
protection: with leakage voltage and leakage current
protection devices, safety meets national standards
2 Product composition
2.1 Training table The training table is supported by aluminum profile columns, and the universal wheels
at the bottom are equipped with brakes, which can be flexibly moved and positioned. The table top
adopts a 25mm thick high-density substrate, and the surface is treated with high-temperature and high-
pressure fire-resistant board. It is equipped with one three-section drawer type drawer and one bottom
cabinet. The structure is firm and beautiful.
2.2 Training workbench (1) Total power supply-4P earth leakage circuit breaker (2) Emergency stop
unit (3) AC380V three-phase AC output unit + three-phase indicator + three-phase overload insurance (4)
AC220V single-phase AC output unit + indicator + overload insurance (4) Socket (5) DC 24V power
supply (6) Analog voltage DC0-10V signal and analog current DC4-20mA signal unit (7) Analog voltage
DC0-10V signal and analog current DC4-20mA signal unit (8) DC 24V power supply (9) Socket
2.3 Panel module (1) plc master station (CPU 1211C + CM1241 RS232 + CM1243-2) (2) Layout
drawing (3) plc slave (CPU 1211C + CM1241 RS232) (4) S22.5 data decoupling module + AS-i slave
(4DI) (5) Master station terminal module (6) Switch (7) Router (8) Slave terminal module (9) Button
indicator module (10) Touch screen module (11) Button indicator module
2.4 Supporting devices (1) 3 network cables (2) RS232 communication line (3) Wired USB network
card (4) 25 pieces of 4mm safety electrical cable (5) 1 piece of digital multimeter (6) Software CD(not
licensed software, teaching purpose with unlimit users)
3 can complete the training content
(1) Siemens PLC programming training (2) Training of PLC and PLC Ethernet communication
(3) Computer monitoring PLC status training (4) PLC and PLC232 communication training
(5) Touch screen programming (6) PLC and touch screen communication training (7) Training of wireless
communication between PLC and computer LAN (8) AS-I communication training of PLC
57
2 Product composition
2-1 Box part
The training device adopts an aluminum profile frame to close the box, which ensures practical weight
reduction, convenient movement and light weight.
2-2 Terminal block
All wiring is connected to the terminal through wires, and insulated terminals are used for safe wiring.
The terminal has an eye-catching logo to prevent plugging errors.
2-3 Programmable Logic Controller Section
Programmable Logic Controller is a digital computing operation electronic system specially designed for
application in industrial environments. It uses a programmable memory that stores instructions for
performing operations such as logic operations, sequence control, timing, counting, and arithmetic
operations, and controls various types of mechanical equipment or production through digital or analog
input and output. process.
When the programmable logic controller is put into operation, its working process is generally divided
into three stages, namely, input sampling, user program execution and output refresh. Completing the
above three phases is called a scan cycle. During the entire run, the programmable logic controller's
CPU repeatedly performs the above three phases at a certain scan speed.
3 Can complete the test
PLC control technology experiment
58
1 Performance parameter
(1) Input power: single-phase three-wire system,
220V±10% 50Hz
(2) Dimension: 1200mm×600mm×1300mm
(3) Whole capacity:<1.0KVA
(4) Weight: <100kg
(5) Work environment:
Environment temperature: -10℃~+40℃
2 Product composition
2.1 Power control panel: The power control panel uses aluminum alloy panel, all close type box
structure, the upper part uses industrial aluminum profile as detachable hanging box fixed beam, the
training hanging box can be easily removed and installed.
2.2 Training bench: The training bench uses aluminum upright support. There are universal wheels at
the bottom with brake mechanism, the bench can be moved or positioned flexibly. The bench top uses
25mm thick high density substrate, and there is high temperature high pressure anti-fire treatment
process. It is equipped with two three-section rail type drawers, and two double acting door bottom
cabinets. The structure is sound and reliable, outlook is beautiful.
2.3 Power box: (1) Single-phase three-wire power input, it is controlled by leakage breaker, it has
emergency stop button, you can press emergency stop button breaker to cut off electricity when
emergency. (2) Analog voltage meter is used as output indication.(2)It is equipped with power indicator,
Europe power output socket and safety power output terminal.(3) 5V,12V DC power supply output are
built-in, with short circuit protection function.
2.4 Main matching experiment hanging box and devices: (1)CPU (80C535 or 89S52) unit and user
and display unit experiment hanging box.(2) Anti-theft sound and light alarm unit experiment hanging
box(3) Traffic light control unit experiment hanging box (4) Step motor drive and control unit experiment
hanging box (5) Liquid proportion mixing control unit experiment hanging box (6) Tunnel ventilation
system control unit experiment hanging box (7) Temperature measurement and control unit experiment
hanging box (8) Microcontroller programmer and development tools (9) Digital Multimeter (10) K2 test
line (11) 4mm safety electrical cable
3 Training project
1. Microcontroller basic programming experiment: Digital electronic clock circuit experiment
59
2.3 power supply configuration: (1) single phase three-wire power supply input, through leakage
circuit breaker control output, with emergency stop control button, press the emergency stop button
breaker to cut off the power.(3) equipped with power indicator, European power output socket and
secure type power supply terminal.(4) built-in ac power, with short circuit protection.(5) built-in dc power,
with short circuit protection.
2.4 supporting devices: (1) 2 piece cylinders transparent water tank(2) 1 piece transparent storage
tank(3) three piece solenoid valves(4) 1 piece water pump(5) flow sensor 1 piece(6) liquid level sensor
3 piece
(7) water level switch 3 piece(8) PLC module 1 piece(9) 1 set of programming software (teaching
edition)(10) pipe fittings and joint sets
3 Complete training contents: 1. Liquid level control experiment 2. Flow control experiment 3. Double
capacity tank control experiment 4. Comprehensive control experiment of dynamic liquid level flow5. PLC
programming control experiment
60
2 Overview
Process control is the abbreviation of automatic control of production process, which is an important part
of automation technology. Usually refers to the production process of oil, chemical, electric power,
metallurgy, light industry, building materials, nuclear energy, etc. In modern industrial production process,
process control technology is to achieve optimal technical and economic indicators.
Take key technology and equipment system in process industry automation and information system as
the main line, we design advanced process control professional laboratory comprehensive training and
teaching equipment, set up the theme of the major laboratory engineering training base.
This training unit’s design is reasonable, with high versatility, not only satisfy university and college
industrial automation, automatic control etc. specialized subject of professional courses related to the
requirement of experimental teaching, but also suitable for graduate students project topics in the
research and development.
This equipment contained four kinds of process control: level, control, temperature control, pressure
control and flow Control.
3 Experiment list
Experiment 1 Liquid level control
Experiment 2 Flow control
Experiment 3 Temperature control experiment
Experiment 4 Pressure control experiment
61
1 Overall Introduction of the system: 1 Working power: three-phase four-wire 380V±5% 50Hz;
Dimension: Object1600×800×1980; 3 The machine capacity:<5KVA Control signal: voltage0~5V;
2 Hardware and software
1. Power control screen( iron double matte dense coating structure, aluminium panel)
(1) AC power panel (2) Actuator and I/O signal port panel 2. Experiment table 3.AC variable frequency
control (4) Intelligent instrument control 1) Intelligent accommodometer 2) Intelligent clamping
accommodometer 4. Remote data acquisition control 4.1)Remote data acquisition control system hardware
components 4.2) Remote data acquisition thermal resistance input module 4.3) Remote data acquisition
analog quantity output module 4.4) Remote data acquisition analog quantity input module 4.5) RS232/485
communication transverter 4.6) Remote data acquisition control system software components
5 S7-200 PLC process control 5.1 S7-200 system hardware module 5.2 S7-200 PLC programmable control
software
3 Experiment project
1. Process control system structure composition understanding experiment
2. Controlled objects characteristic testing experiment
3. Single loop control system experiment
4. Temperature clamping control system experiment
5. Cascade control system experiment
6. Ratio control system experiment
7. Hysteresis control system experiment
8. Industrial control configuration software configuration control experiment
62
1 Features: Contains a selection of level and flow sensors & indicators, Flow controlled by linear
motorised control valve, On/Off and proportional control, P, PI and full PID control with autotune facility,
Couples with Temperature Trainer for dual loop control, Water used as the process fluid
2 Curriculum Coverage: Flow & Level familiarisation and calibration, Interface familiarisation and
calibration, Controller familiarisation and calibration, Float level transmitter, Pulse flow transmitter,
On-Off control, Study of P, PI and PID control of Level and Flow, Tuning PID controllers, Advanced
process control
3 Study different principles of flow meters
Used flow meters: electromagnetic flow meter, ultrasound flow meter
- rotameter or orifice to measure with transducer
- closed water circuit
Flow meter mounted horizontally or vertically
- equipped with valve to adjust the flow
- electromagnetic flow sensor as a referral for flow meters calibrating
- 2 manometers with double tubes
- differential pressure transmitter from 0 to 2 bars at least
- water tank : 50 L at least
Pump:
- max HMT: 10m
Power supply: 24VDC
- electrical panel
Will be powered by 220V/50Hz
Will be supplied with all necessary accessories
63
Thermistor temperature sensors are located in the inlet and outlet streams of both primary and
secondary sides of the heat exchanger and the outlet of the radiator.
The Trainer can be used with a cold mains water supply through the Auxiliary Temperature Control Pack
which is supplied as part of the system. This comprises a motorised control valve, a flow meter and a
signal conditioning unit. Alternatively the Temperature Trainer can be connected to the Level & Flow
Process Trainer, which then supplies the cold water circuit.
2 Features: Temperature control, P, PI and PID control with autotune facility, Primary circuit flow
controlled by motorised control valv, Primary circuit heater and pump, Secondary circuit fan-assisted
cooling radiator,
Water used as the process fluid.
3 Curriculum Coverage: Temperature familiarisation and calibration, Interface familiarisation and
calibration, Controller familiarisation and calibration, Pulse flow transmitter, On-Off control, Study of P, PI
and PID control of Temperature and Flow, Manual flow control, Temperature process control,
Complex control loops
4 Study different method of temperature measuring: non electrical methods, electrical methods, air
humidity determination, electrical thermal probe calibrating
5 Composed by: immersion heater: Power: 200W at least, Power adjusting provided via power
regulation socket, heating element, Power : 300W, Max temperature: 100°C, thermoses bottle, Pt100, K
type thermocouple with transmitter 4-20 mA, Thermistance CTN, mercury thermometer, bi-blade
thermometer, gas pressure thermometer, temperature measuring band, precision resistances: 10Ω,
100Ω, 1000Ω, psychrometer for humidity measuring:. 2 x temperatures, humidity
Calibrating equipment: precision resistances: 10Ω, 100Ω, 1000Ω, adequate digital multimeter, Electrical
console with 5 screen displayer and control operating (verify for calibrating)
Will be supplied with: case to range probes, wires, measuring bands
- wires set
64
The Pressure Trainer requires a compressed air supply at a recommended input pressure of
40psi. An input filter/drier is used to clean the supplied air. Separately regulated branches provide air for
the process and for valve control. The process branch comprises a regulator, a variable area flow meter,
a pneumatically operated control valve, an orifice block with changeable orifice plates and both
differential and point of measure pressure sensors. The process air flow can be discharged to
atmosphere via adjustable diffused outlets. An air receiver tank can be switched in and out of the circuit.
The valve control branch comprises a regulator and an electrically operated current to pressure input
converter. This is used to regulate the pneumatic control valve in the process line. The input converter
operates from a 4-20 mA signal. Signal conditioning for the sensors is provided by pressure transmitters.
The Differential Pressure Transmitter gives a linear differential pressure sensor output. The system is
fully equipped with pressure gauges to indicate the pressures around the system.
2 Curriculum Coverage: Pressure safety, familiarisation and calibration, Controller familiarisation and
calibration, Automatic control systems, Serial communication, Pneumatic control valve - characteristics
at different pressure ranges, Principles of Proportioning valve and proportional process control, Study of
P, PI and PID control of Pressure, Calibration of the differential pressure sensor & transmitter, Flow
control in the Process rig
3 The apparatus is equipped with: manometer calibrating device: a balance with heights set to product
pressure up to 2 bars at least, Bourdon manometer with visible Bourdon tubes (to see inner mechanism),
U tube manometer, Bourdon manometer to study calibration, inclined tube manometer,
Bourdon manometer to measure vacuum, syringes system to increase or decrease pressure in the
manometers
4 The bench will be supplied with: weight selection for the manometers calibrating device, T
connection, clamp for tubes, funnel, Nylon tube, Silent compressor: pressure 6bars, with safety valve,
powered by 230V / 50Hz
65
66
2 Features
Contains a selection of level, flow, pressure, temperature and PH sensors and indicators
Primary and secondary flow controlled by linear motorised control valves, On/Off and proportional contro
P, PI and full PID control, Can perform dual loop cascade control, Water used as the process fluid
3 Curriculum Coverage
Flow,Level, temperature, pressure and PH familiarisation and calibration, Interface familiarisation and
calibration, Controller familiarisation and calibration, Float level transmitter, Pulse flow transmitter
On-Off control, Study of P, PI and PID control of Level and Flow, Tuning PID controllers, Advanced
process control, Temperature familiarisation and calibration, Interface familiarisation and calibration
Controller familiarisation and calibration, Pulse flow transmitter, On-Off control, Study of P, PI and PID
control of Temperature and Flow, Manual flow control, Temperature process control, Complex control
loops
4 Allows to realize the following applications:
study of industrial regulation loop elements, use and configuration of industrial regulation equipment
tracing and understanding different process characteristic curves, using PLC, data real time display and
analysis, exploitation of the process software
The station is equipped by: fully equipped bench for detailed study of the flow, fully equipped bench for
detailed study of the temperature, fully equipped bench for detailed study of the pressure, fully equipped
bench for detailed study of the level, fully equipped bench for detailed study of the PH
the bench must be installed on rigid frame mounted on rollers with brake and should be corrosion proof,
process software for each bench to be used individually and/or on network (CD/DVD)
Supplied with:
a set of necessary connections with the PC
a set of necessary connection to guaranty the installation and exploitation of the bench
ink jet printer
67
1 Technical capacity
1. Working power supply: single-phase three-wire 220V±5%
50Hz;
2. Dimensions: 1600 × 800 × 1800 mm (L*W*H)
3. Control object power supply: motor AC220V±10%,
regulating valve AC24V±10% 50HZ±10%, heating
AC220V±10%
4. Working environment: -10 ° C ~ 40 ° C, relative humidity:
20% ~ 90% no condensation
5. Working conditions: ambient temperature -10 °C ~
+40 °C Relative humidity <85% (25 °C)
2 Product composition
The installation of the experimental device of the process control system is free from water leakage and
rust, stable operation and low noise. The controlled object is separated from the control electrical system
to avoid electrical leakage caused by liquid leakage:
The experimental device consists of an electrical control box and two controlled objects. The electrical
control box provides various types of power for the system, providing 0-10V and 4-20mA signals, AC24V
and AC220V system power.
68
69
1 Technical Specifications
(1) Input power: Two-phase three-wire, 220V±10%
50Hz
(2) Dimension: 1200mm×600mm×1600mm
(3) Heating power: 1.5KW, Power of agitator: 5W
(4) Heating water tank volume: 20L
(5) Weight: <100kg
(6) Operating conditions: Environment temperature -
10℃~+40℃
2 Product compositions
2.1 Training bench body: Its frame is made of aluminum, its surface is waterproof table-board, there is
4-way AC 220V output power and temperature indicator and controller building in power box, and it is
equipped with cabinet on the bottom.
2.2 Heating water tank: It is made of stainless steel and fixed on the table, its volume is 20L, equipped
with resistance heating and temperature controlling, its outside is insulating layer. There is an agitation
motor on the top of water tank, which drives inner agitating vanes rotating for uniformizing the water
temperature. It is with pointer type thermometer and temperature probe port.
2.3 Temperature probe: Come with various temperature probes, including: 1 thermistor probe for liquids,
1 Platinum resistance probe (PT100) , 1 thermocouple K (Nickel, chrome/nickel-aluminum)
1 thermocouple J (Iron/copper/nickel) , 1 thermocouple S (Platinum-10% rhodium/platinum)
3 Experiments list
Constant temperature and heating control of water temperature
Temperature characteristic of thermistor
Temperature characteristic and method of application of platinum resistor
Temperature characteristic and method of application of thermistor
Temperature characteristic and method of application of K-type thermocouple
Temperature characteristic and method of application of J-type thermocouple
Temperature characteristic and method of application of S-type thermocouple
Use of temperature measurement instrument
Measuring the output difference between different thermocouples at same temperature
with millivoltmeter
70
2- Variable AC Voltage Output: 0-220V(2A), 1xFuse protection, 1xSwitch, 2x4mm safety output terminals,
1xE terminal, 1xDigital voltage and Current meter indication for workstation.
3- Variable DC Voltage & Current Output(w/LED): 0-30V(3A), 1xFuse protection, 1xSwitch, 2x4mm
safety output terminals, 1xDigital voltage and current meter indication, 1xE Terminal for workstation.
4- Function Generator(w/LED): 1xFuse protection, 1xSwitch, 1xE Terminal, 1xDigital synthetised function
generator 3MHz (sine, square, pulse, triangle, TTL) w/ 4xBNC Terminal for workstation. (1xSingle-Pulse
Switch, 1xSignle-Pulse Source output socket, Sine-wave output voltage indicator, 1xSine-wave reduction
switch,1xSine-wave adjusting switch, 1xRectangular & Triangular & Sine-wave output socket,
1xRectangular wave adjusting switch, 1xFrequency fine adjusting switch, 1xFrequency thick adjusting
switch,1xFrequency indicator).
5- Universal Socket out 220V-16A(EU&US-standard type): 2x[2Gang or Double(1p+N+E), 1xCB 2P-16A],
1 for LEFT and 1 Right of the workbench table for workstation.
6-Supply three drawers for put components etc.
7-Supply strengthening treatment, this workbench will not waggle or shake.
8-Catalogues and user manual, ( All in ENGLISH)
2 Equipment parameter
Dimension: 1500mmx 800mmx 750mm,
Weight: 80kgs
Whole capacity: <1KVA
Work power: AC220V±10%, single phase, three wires, 50Hz
71
1 Overview
This trainer is double sides, two work stations for two
students, every work station has independent power,
stainless patch board, hanging box. The control circuit of
electromotor
2 Experiment list
1) Y-△ reduced voltage starting self-control circuit of time relay
2) Contactor self-locking forward control circuit
3) Contactor self-locking forward control circuit with overload protection
4) Inching and continuous mixed forward control circuit
5) Forward and reverse control circuit of contactor interlocking
6) Forward and reverse control circuit of button and contactor double interlocking
7) Position control circuit( also called travel control circuit or limit control circuit)
72
1 Technical parameter
1.Dimension: 1600×800×1800 mm(L×W×H) ,use blue
industrial column, the sectional dimension
123×34(L×W) ,workbench thick is 25mm anti fire
board, patch board dimension is 640×730MM,we
supply free installation seats and installation bolt.
2.Power input: three phases, five wires AC380±10%
50HZ±10% 3.Power control(per work station) :
leakage breaker to control the connect and
disconnect for power, with short circuit protection, leakage protection, Output(per station) :
2 Equipment include the following
2.1 Power control panel: Power control panel use aluminum panel, close type structure, meter box and
power box is individual configuration, there are 2 pcs stainless patch board on workbench, it is easy to
use.
2.2 Training workbench: Training workbench use aluminum structure. There are universal 4 wheels at
the bottom of workbench, there are 2 breakers on wheel. The trainer can be moved or stop convenient .
The workbench panel thick is 25mm high density substrate , there is high temperature high pressure
anti-fire treatment process. It equip with three guide rail type drawer, 2 push and plug cabinet. The
structure is sound and reliable, outlook is beautiful.
2.3 Power box: (1) Three phase five wire power input, go through breaker controller, there is emergency
stop button to cut off power supply.(2) power output for 2 work position for 2 students, independent
output, each location provide as follows:A, three-phase ac 380 V plus or minus 10% frequency, 50 HZ;
Single-phase ac 220 V plus or minus 10% frequency, 50 HZ.B, DC voltage stabilizer: 0 ~ 30 V3A
piecewise adjustable, three and a half digital headers to display voltage, current, with the current limit
type short circuit protection and recovery from soft function, and has the sound and light alarm function.
2.4 meter box: With a pointer type AC voltmeter, ammeter, frequency meter, power meter, power factor
meter, Single-phase kilowatt hour meter.
2.5 Equip composition
a. Stainless patch board 2 pieces b. 600 pairs of stable installation seat and bolt c. Cabinet 1
d. Drawers: 2 e.Wheels:4 f. Brake in wheel 2 pieces g.Brakes:2 h. Aluminum column:2 long, 2 short i.
Power box 1 piece
73
2 Technical data
2.1 Power control panel use aluminum panel, close type structure, meter box and power box is
individual configuration, there are 2 pcs stainless patch board on workbench, it is easy to
use.
2.2 Training workbench: Training workbench use aluminum structure. There are universal 4 wheels at
the bottom of workbench, there are 2 breakers on wheel. The trainer can be moved or stop
convenient . The workbench panel thick is 25mm high density substrate , there is high temperature high
pressure anti-fire treatment process. It equip with three guide rail type drawer, 2 push and plug cabinet.
The structure is sound and reliable, outlook is beautiful.
2.3 Power box: (1)Three phase five wire power input, go through breaker controller, there is emergency
stop button to cut off power supply.(2) power output for 2 work position for 2 students,independent output,
each location provide as follows:A, three-phase ac 380 V plus or minus 10% frequency, 50 HZ; Single-
phase ac 220 V plus or minus 10% frequency, 50 HZ. B, DC voltage stabilizer: 0 ~ 30 V3A piecewise
adjustable, three and a half digital headers to display voltage, current, with the current limit type short
circuit protection and recovery from soft function, and has the sound and light alarm function.
2.4 Equip tools and components
(1) ZE3107 Electrical installation training workbench 1 set
a. Stainless patch board 2 pieces b. 600 pairs of stable installation seat and bolt c. Cabinet 1 d. Drawers:
2 e.Wheels:4 f. Brake in wheel 2 pieces g.Brakes:2 h. Aluminum column:2 long, 2 short i. Power box 1
piece
74
2 Product composition:
2.1 Power control panel: Power control panel use aluminum material panel, close box type structure, it
connect with industrial frame.
2.2 Training workbench: Training workbench use aluminum material column. There are 4 wheels in
bottom, 2 of them has brake, it can move or fix easily. It use 25mm high density base panel, surface use
anti fire high temperature, high pressure treatment, it equip with three guide rail type cabinet, there are 2
drawers,2 push and pull door base cabinet , structure is sound, and beautiful.
2.3 Power box: (1)Three phases, five wires power input, it controlled by leakage breaker. There are
emergency control button, you can press emergency stop button to cut off power supply. (2)Inner AC
voltage meter 1 pc, voltage convert switch 1 pc, AC current meter 1 pc, three phases power meter 1 pc,
single phase AC voltage meter 1 pc, power factor meter 1 pc, frequency meter 1 pc, Watt-hour meter 1
pc.(3)Equip with power indicator, Europe power output socket, safety power output interface.
2.4 Main equip measurement meters and components: (1)Clip-on ammeter (2)Point type multi meter
(3)Digital multi meter (4)Digital capacitance meter (5)Tramegger (6)Transistor digital millivolt meter
(7)40M Signal generator (8)60M Digital dual trace oscilloscope (9)Analogue oscilloscope (10)DC voltage
power (30V3A) (11)Resistor box (12)Mutual inductor and capacitance components box
3 Experiment training project that can be finished: Training 1: understand electrical measurement
meter Training 2: current meter, voltage meter, power meter, frequency meter, power factor meter
usage Training 3: measurement mutual inductor usage Training 4: clip-on ammeter usage Training 5:
point type multi meter usage 6: digital multi meter usage Training 7: digital capacitance meter usage
Training 8: tramegger meter usage Training 9: transistor millvoltmeter usage Training 10: watt-hour meter
usage Training 11: Signal generator usage Training 12: analogue oscilloscope usage Training 13: digital
oscilloscope usage Training 14: DC regulated power supply usage
75
1 Technical parameters
(1) Input power: three-phase five-wire system
380V±10% 60Hz
(2) Dimensions: 1600mm × 400mm × 1200mm
(3) Machine capacity: <1.5KVA
(4) Weight: <150kg
(5) Working conditions: ambient temperature -
10 ° C ~ +40 ° C Relative humidity <85% (25 °
C)
2 Product composition
2.1 Power Control Screen
The power control panel adopts an aluminum alloy profile panel, and the closed box structure is
integrated with the lower placement frame.
2.2 Power Control Screen Configuration
(1) Three-phase five-wire power input, controlled by leakage circuit breaker, with emergency stop
control button. In emergency, press the emergency stop button breaker to cut off the power. (2) It is
equipped with a power indicator, a power outlet, and a safety power output terminal. (3) Configure
the AC motor special protection switch, built-in AC power supply, with short circuit protection. (4)
Built-in AC power supply with short circuit protection.
2.3 Components
(1) Hanging box module
The training device is equipped with 11 hanging box modules, which can be connected through the
4mm safety electrical cable for related experiments.
3 Training content can be completed
3.1 Three-phase AC asynchronous motor related experiments
3.2 series excitation DC motor related experiments
(1) Motion function and transmission group test
(2) Static test of motor technical parameters
(3) Motor control circuit connection and function
(4) Technical test of sports function
76
1 Technical parameters
(1) Input power: three-phase five-wire system 380V±10%
60Hz
(2) Dimensions: 1100mm × 400mm × 1200mm
(3) Machine capacity: <1.5KVA
(4) Weight: <150kg
(5) Working conditions: ambient temperature -10 ° C ~
+40 ° C Relative humidity <85% (25 ° C)
2 Product composition
2.1 Power Control Screen
The power control panel adopts an aluminum alloy profile panel, and the closed box structure is
integrated with the lower placement frame.
2.2 Power Control Screen Configuration
(1) Three-phase five-wire power input, controlled by leakage circuit breaker, with emergency stop
control button. In emergency, press the emergency stop button breaker to cut off the power. (2) It is
equipped with a power indicator, a power outlet, and a safety power output terminal. (3) Configure
the AC motor special protection switch, built-in AC power supply, with short circuit protection. (4)
Built-in AC power supply with short circuit protection.
2.3 Components
(1) Hanging box module
The training device is equipped with 10 hanging box modules, as shown in the following figure,
respectively: button hanging box module, air circuit breaker hanging box module, fuse hanging box
module, bulb load hanging box module, button hanging box module, limit position Switch module,
relay hanging box module, contactor hanging box module. Related experiments can be performed
through the4mm safety connection cable.
2.4 Companion devices
(1) Time relay control unit (2) Thermal delay overcurrent relay control unit (3) Contactor interlock
circuit control unit (4) button module (5) Air circuit breaker module (6) Fuse module (7) Limit switch
module
77
density fireproof board, and the bottom of the countertop is provided with a movable lockable wheel for
easy movement..
2 Performance parameters
(1) Input power: three-phase five-wire system 380V±10% 60Hz
78
2 Performance parameters
(1) Input power: three-phase five-wire system 380V±10% 60Hz (2) Dimensions: 720mm × 550mm ×
1800mm (3) Machine capacity: <1.5KVA (4) Weight: <150kg
(5) Working conditions: ambient temperature -10 ° C ~ +40 ° C Relative humidity <85% (25 ° C)
3 Experiment list
Electrical control training: Experiment 1 Direct start control of three-phase asynchronous motor
Experiment 2 Three-phase asynchronous motor contactor jog control circuit Experiment 3 Three-phase
asynchronous motor contactor self-locking control circuit Experiment 4 three-phase asynchronous motor
stator string resistance step-down starting manual control circuit Experiment 5 Three-phase
asynchronous motor stator string resistance step-down starting automatic control circuit Experiment 6 Y-
△ start automatic control circuit Experiment 7 Contactor self-locking three-phase asynchronous motor
forward and reverse control Experiment 8 button self-locking three-phase motor contactor positive and
negative control Experiment 9 double self-locking three-phase asynchronous motor forward and reverse
control Experiment 10 three-phase asynchronous motor one-way step-down starting and reverse braking
control circuit Experiment 11 Dynamic Braking Control of Three-phase Asynchronous Motor
Experiment 12 sequential control of three-phase asynchronous motor Experiment 13 three-phase
asynchronous motor remote and local control Experiment 14 three-phase asynchronous motor forward
and reverse jog start control circuit Experiment 15 Workbench automatic round trip control line
79
1 Overview
With the German Rittal cabinet form according to the standard for the industrial site electrical design, can
achieve all types of PLC control system, it meet industrial use and training needs.
2 Technical parameter
1. Input power: AC 220V (single three lines) frequency 50 Hz
2. Relative humidity: more than 85%
3. Environmental temperature: 10℃ ~ 40 ℃
4. Equipment weight: about 100 Kg
80
Power box: (1)Three phases, five wires power input, it has been tested by leakage breaker control, it has
emergency stop button, you can cut off electricity when emergency. (2) Power box parameters:
aluminum profile box, leakage protection circuit breaker, power indicator light, emergency stop switch,
provide AC 220V output socket, DC fixed 5V, plus or minus 12V, DC 0-36V adjustable output, low
voltage AC 6V, 12V output , DC voltmeter, DC ammeter
3 Experiment list:
Ohm's law Type of resistor (potentiometer varistor)
1) Series resistance circuit
2) Parallel resistance circuit
3) Kirchhoff's series circuit law
4) Kirchhoff's parallel circuit law
5) Series - Parallel
6) Voltage divider
7) Current divider
8) Star ^ delta 9) delta ^ Star 10) Power transmission
Capacitors and capacitors
1) Series capacitor circuit
2) Parallel capacitor circuit
3) Series - Parallel circuit
4) Grid Analysis (Maxwell)
5) Intersection
6) Superposition theorem
7) Thevenin's theorem
8) Norton's theorem
9) Interaction.
81
82
1 Overview
With the German Rittal cabinet form according to the standard for the industrial site electrical design, can
achieve all types of soft start control circuit structure, control of powerful motor soft start-up operation,
meet industrial use and training needs.
2 Technical parameter
1. Input power: AC380V (three phases five wires) frequency 50 Hz
2. Relative humidity: more than 85%
3. Environmental temperature: 10℃ ~ 40 ℃
4. Equipment weight: about 80 Kg
83
lamp, dual-control double-control switch, sound and light control switch, touch switch, socket, etc., to
meet the teaching requirements and experimental requirements.
3.2 Electrical control part training: This part contains a variety of low-voltage electrical appliances,
such as leakage circuit breakers, fuses, current transformers, contactors, intermediate relays, time relays,
thermal relays, travel switches, buttons, signal lights, transfer switches, voltmeters, ammeters and three-
phase four Circuit meter, etc., meet the teaching requirements and experimental requirements.
3.3 Cabinet part: (1) Three-phase five-wire power input. (2) There are power indicator lights and safety
power output terminals. (3) Controlled by leakage circuit breaker, output three-phase power and single-
phase power.
4 The experiment which can be finished
Electrical control cabinet: Experiment 1 Direct start control of three-phase asynchronous motor.
Experiment 2 Three-phase asynchronous motor contactor jog control circuit. Experiment 3 Three-phase
asynchronous motor contactor self-locking control circuit. Experiment 4 three-phase asynchronous motor
stator connect serial resistance step-down starting manual control circuit. Experiment 5 Three-phase
asynchronous motor stator connect in serial with resistance step-down starting automatic control circuit.
Experiment 6 Y-△ start automatic control circuit. Experiment 7 Contactor self-locking three-phase
asynchronous motor forward and reverse control. Experiment 8 button self-locking three-phase motor
contactor forward and reverse control. Experiment 9 double self-locking three-phase asynchronous
motor forward and reverse control. Experiment 10 three-phase asynchronous motor one-way step-down
starting and reverse braking control circuit. Experiment 11 Dynamic Braking Control of Three-phase
Asynchronous Motor Experimental 12 sequential control of three-phase asynchronous motor.
Experiment 13 three-phase asynchronous motor remote and local control. Experiment 14 three-phase
asynchronous motor forward and reverse jog start control circuit. Experiment 15 Workbench automatic
round trip control circuit Experiment 16 automatic round trip control circuit with jog. Experiment 17
84
85
2 Technical performance
1. Input power: three-phase five-wire system input 380V ± 5%, 50Hz AC, with indicator light.
2. Working environment: ambient temperature range is -5 to +40 °C Relative humidity <85% (25 °C)
altitude <4000m.
3. Device capacity: <1.5KVA.
4. Output AC power: According to different wiring, it can output three-phase 380V and single-phase 220V.
AC 0~250V/2A continuously adjustable; AC 0~36V/2A continuously adjustable; with dual range AC
voltmeter indication. With overcurrent and short circuit protection.
86
87
88
type structure, measuring instrument and load module uses the way of hanging box installation, training
power built-in integrated installation, each unit with flexible, easy to use, not easy to damage.
(2) the experimental circuit and devices are fully configured and can be used in combination to complete
the training contents of a variety of subjects.
(3) the training platform has a good security system.
1.2 Technical parameter
(1) industrial safety power plant: all aluminum alloy structure with dimensions 1160 * 410 * 1050mm
(L*W*H).
(2) power box unit: aluminum profile panel structure, embedded installation of power parts, instrument
and load module with aluminum alloy hanging box unit form, connection convenience.
1.3 Consist components
The ground training device is mainly composed of power box, instrument hanging box and load hanging
box. 1. Power box unit. The power box unit of the training station is shown in the figure below. The power
box panel configuration is as follows: (1) power supply unit (2) IT power network (3) TT power supply
network (4) TN-C-S power supply network (5) 2P circuit breaker (6) power indicator light (7) AC2220V
power supply terminal. 2. Hanging box assembly. 2.1 trigger voltage FV - 1. 2.2 Pulsating DC module
FI-2. 2.3 leakage current module FI-3. 2.4 transformer module TR-1. 2.5 Human resistance testing
module HM-3. 2.6 current and voltage meter module(HM-4). 2.7 Ground resistor module PB-1. 2.8 load
module(LD-1). 2.9 load module LD-4. 2.10 Load module LD-5. 2.11 Load module LD-6. 2.12 Load
module LD-7. 2.13 Load module LD-8
89
1 Product Overview
1.1 Profile
The system can simulate the process of
grounding system, so that students can have a
preliminary intuitive understanding of the
grounding system, and be familiar with the
composition, connection and operation principle of
the grounding system. To cultivate the students'
corresponding knowledge and skills, suitable for
teaching and skills training assessment of higher vocational colleges, secondary vocational schools and
technical schools.
1.2 Feature
(1) training platform adopts aluminum frame type structure, measuring instrument and load module uses
the way of hanging box installation, training power built-in integrated installation, each unit with flexible,
easy to use, not easy to damage. (2) the experimental circuit and devices are fully configured and can be
used in combination to complete the training contents of a variety of subjects. (3) the training platform
has a good security system.
1.3 Technical data
(1) ground training device: all aluminum alloy structure, the shape dimension 800 * 800 * 1580mm (long
width). (2) power box unit: aluminum profile panel structure, embedded installation of power parts,
instrument and load module with aluminum alloy hanging box unit form, connection convenience.
1.4 Composed components
The ground training device is mainly composed of power box, instrument hanging box and load hanging
box.
1. Power box unit.
2.Hanging box components.
2.1 Human body impact current hanging box(PW-1)
2.2 Load module(LD-5).
2.3 Voltage and current meter module(HM-4).
2.4 PB-1 Detector module. 2.5 LD-6 Load module
90
1 Technical parameter
(1) Input power: single phase three wire, 220V±10% 50Hz, (2)
Dimension: 1600mm×800mm×1800mm, (3) Whole capacity:<
2.0KVA, (4) Weight: <100kg, (5) Work condition: Environment
temperature:-10℃~+40℃, Relative humidity: <85%(25℃)
2 Product composition
2.1 Training workbench: Training workbench surface use anti-fire
treatment, it has a long life to use, and has a
to use, and has a beautiful outlook.
2.2 Power control panel
(1)Single phase three wires power input, it goes through electric leakage breakers to be controlled. It has
emergency stop button, when in emergency circumstance, press it, and breakers cut off power
supply.(2)Equip with power indicator, power output plug, safety power output terminal.
2.3 Equip with components: (1)Transformer (2)round resistor meter (3)tramegger (4) Electric cables 25
eas
3. Hanging modules name
1. V/I Measuring module, 2.Probe, 3.Potential trap, 4.Body shock current, 5.Body resistance(50Hz)
6.Transformer-1, 7.Transformer-3, 8.Low voltage protection, 9.Fault current circuit breaker(30 mA)
10.Fault current circuit breaker trigger, 11.Trigger current, 12.Trigger voltage, 13.Body experiment model
14.Load module-1, 15.Load module-4, 16.Load module-5, 17.Load module-6,
18.Load module-7, 19.Load module-8
4 Training content
3.1 Insulation protection training and experiment:(1) Insulation resistor testing (2) Insulation
characteristic testing (3) insulating medium experiment, 3.2 Low voltage protection experiment: (1)
Safety voltage testing (2) Transformer characteristic testing, 3.3 Ground experiment testing: (1)
Ground type (2) Ground bar usage (3) Ground power system and don’t connect ground power system (4)
Multi points network testing (5) Ground resistor testing (6) Ground rod usage and testing,
3.4 Current protection experiment: (1) Zero sequence current application (2) Current leakage breaker
protection(3) Over current fault protection, 3.5 Voltage protection experiment: (1) Zero voltage
protection experiment (2) Over voltage experiment(3) Voltage type breaker protection experiment,
3.6 Circuit resistor testing experiment : (1) Circuit resistor testing (2) Wire resistor testing
91
2-2 physical part: With a real washing machine, you can observe the experimental phenomenon more
intuitively and deepen the impression of various malfunctions of the washing machine.3-3 Electrical
Controller Section: By controlling various faults through switches, various common phenomena in the
actual use of the washing machine can be simulated. The silk screen has a schematic diagram of the
washing machine, which is convenient for students to understand the operating principle of the washing
machine. The control part has a six-hole socket on the side to supply power to the washing machine.
3 Experiment list: Washing machine failure test
and generous. The actual training power is integrated with installation, easy to use and not easy to
damage. (2) the training platform has a good security system.
2 Technical parameter: (1) input power: AC220V / 50Hz, (2) External dimensions: 1565 * 400 *
1070mm, (3) Unit capacity: < 1KVA, (4) Weight< 50kg
3 Product composition: 3.1 Power unit. 3.2 Camera power supply. 3.3 Displayer. 3.4 8 roads analogue
hard disk video(DVR: 7 inch). 3.5 4 pieces of hemisphere surveillance camera ST-8604RH-6mm. 3.6 1.3
millison WebDome ST-V38-130W-3.6mm remote control type. 3.7 1.3 million WebDome ST-V40-
130W-12mm software control type. 3.8 1.3 million web camera. 3.9 AHD 2 million analogue high
resolution camera ST-AHD-A-6mm
92
1 Product overview
1-1 Overview: The training device is a drum training
module, which has the same function as the actual
washing machine. The product can be used to simulate a
variety of washing machine faults to meet a variety of
experimental requirements.
1-2 features: 1. This training machine is developed for the
practical application of washing machine control
technology and can be used according to training
requirements.
washing machine control technology and can be used according to training requirements. 2, using
standardized modular design, placed light. 3, the use of switches to control faults, safe and convenient.
2 Technical parameters
(1) Dimensions: 1350mm × 930mm × 1700mm,
(2) Weight: <150kg,
(3) Working conditions: ambient temperature -10 °C ~ +40 °C
Relative humidity <85% (25 °C)
3 the product composition
3-1 frame part: The frame is made of aluminum profile to ensure the strength while reducing weight and
easy to move. The bottom is equipped with four cushions, which are light and compact.
3-2 physical part: With a real washing machine, you can observe the experimental phenomenon more
intuitively and deepen the impression of various malfunctions of the washing machine.
3-3 Electrical Controller Section: By controlling various faults through switches, various common
phenomena in the actual use of the washing machine can be simulated. The silk screen has a schematic
diagram of the washing machine, which is convenient for students to understand the operating principle
of the washing machine. The control part has a six-hole socket on the side to supply power to the
washing machine.
IV. Experiment list
Washing machine failure test
93
94
95
1.2 Feature: (1) Aluminum profile frame structure is adopted to facilitate the installation of devices. Each
unit is flexible and easy to use and not easily damaged. (2) The experimental devices are fully configured
and can be used in combination to complete a variety of training contents.
1.3 Technical parameter: (1) solar power plant: dimensions 2000 * 2000 * 2040mm (L*W*H). (2) the
aluminum profile frame structure is easy to install and easy to connect.
suitable for the teaching and skills training assessment of higher vocational colleges, vocational schools,
secondary vocational schools and technical schools.
1.2 Feature
(1) the training platform adopts the frame structure of aluminum profile, and the units are flexible and
easy to use and not easily damaged.(2) the experimental circuit and devices are fully configured and can
be used in combination to complete the training contents of a variety of subjects. (3) the training platform
has a good security system.1.3 Technical parameter: Fire alarm system installation: all aluminum alloy
structure, dimensions 1565 * 400 * 1070mm (L*W*H). 1.4 Composed module:1.4.1 Fire alarm control
panel, 1.4.2Power unit, 1.4.3 smoke sensor, 1.4.4 temperature sensor, 1.4.5 Manual fire alarm, 1.4.6
Sound and light alarm
96
97
98
99
3 Equip components : (1) Controller hanging box 1 piece (2) Inverter hanging box 1 piece. (3) Meter
box hanging box 2 pieces (4) Terminal load hanging box 2 pieces. (5)4mm safety electrical connection
cable 40 eas
4 Experiment list: (1) Battery feature test:1) electricity technical parameter 2) Battery connect in series
and parallel (2) Charge controller experiment:1) connect inversed protection experiment 2) Controller
protection on battery overcharge 3) Controller protection on battery over discharging experiment 4) Anti
reverse charge experiment
(3) Simulate wind generating electricity system experiment
(4) Wind energy charging control experiment (5) Generator work power test experiment
(6) Photovoltaic battery open circuit voltage test experiment
(7) Photovoltaic battery short circuit current test experiment
(8) Photovoltaic battery work power test experiment
(9) To test photovoltaic battery different maximum test experiment under different illumination
(10) Photovoltaic battery output feature experiment
(11) Photovoltaic battery charging control principle experiment
(12)Photovoltaic battery anti reverse charging experiment
(13) Photovoltaic battery connect in series and parallel experiment
(14) Inverter basic principle experiment (15) Simple inverter output waveform test experiment
(16) Photovoltaic battery connect in series and in parallel experiment
(17) Inverter basic principle experiment (18) Simple inverter output waveform test experiment
(19) Inverter power drive AC load experiment
(20) Wind and solar generator complementary experiment
100
101
102
103
104
2 Product feature
The product consists of a training model and a test box, modular design, and an simulation light source.
Experiments can also be carried out indoors. The test box is made of thick aluminum alloy frame and
epoxy resin board, which has high compressive strength and good insulation performance. The test box
uses an integrated design to reduce the size and weight of the device and facilitate movement. The
distance between the training module solar panel and the simulation light source is adjustable, which is
convenient for students to test the characteristics of the solar panel. All instruments use digital display
instruments, which can more easily and accurately obtain experimental data and complete experiments.
3 Product technical data
(1) Input power: 220V±10% 50Hz
(2) Dimensions: test box 620*620*180
(3) Training module: 1500mm*410mm*480mm
(4,) Weight: <25KG
(5) Working conditions: ambient temperature 10 ° C ~ 30 ° C
Relative humidity <75% (25 ° C)
4 Experiment list
Experiment 1 Battery charging characteristics and discharge protection
Experiment 2 Solar Generation Set Connection Experiment
Experiment 3 Inverter Test
Experiment 4 Photovoltaic cell open circuit voltage test experiment
105
106
Energy balance in combined heating systems for demonstrate hot water production and hearing. Heat
transfer in an underfloor heating system. Use of heat source for heat pump systems, Pipes, Lengths(not
less than): 10m, 20m, 30m, Material: polytechyene, Wall thickness:2mm, Outer diameter: 16mm,
Operating pressure: max 3bar, Tank: Volume: 200L, Measuring ranges, Temperature: 0..160degree,
Flow rate: 0... 1000L/h, Specifications:Evaporator, 1.5KW variable load electrical heaters, B)compressor
1HP belt driven type, C)condencer, Water colled by internal cooling heaters, D) Expansion valve
Thermostatically controller
SR2102 Educational Photovoltaic System(Off Grid Training Equipment)
1 Capacity
(1) Solar power systems: the aluminum alloy structure, photovoltaic panels angle is adjustable, with
wheels at the bottom of workbench, it can be mobile and lockable, dimension: 1200 * 1200 * 1760 mm
(L*W*H). (2) Off-grid training workbench: fully aluminum alloy structure, with a universal wheel at the
bottom, can be mobile and lockable, dimension 1000 * 800 * 1400 mm (L*W*H). (3) Power box unit:
aluminum panel structure, power supply components embedded installation, instrument and load module
uses the aluminum alloy hanging box unit, the connection is convenient. (5) the S-3000-36 off-grid
inverter parameters
107
1 Product Overview
1.1 Profile
This training system simulate demo wind and solar generate electricity process, enable students to learn
photovoltaic off-grid power generation knowledge, connection, run principle. This trainer cultivate
students hand on ability, it’s suitable for engineering university, training institute, technical schools. It
takes small size axial-flow type generator, lift water in reservoir to spiral water inlet by high-power water
pump, drive vane wheel of generator to generate electricity, generated power is 300W, it takes aluminum
frame, it is equipped with voltmeter, ampere meter, frequency meter and other measurement modules, it
has analog load, it can fully demonstrate electric-generation principle and process of water turbine,
dimension is about 1500*600*1200mm
1.2 Feature
(1)This trainer use aluminum column structure, with measurement meter hanging box, load module
hanging box, there is universal wheels at the bottom, it’s easy to move. (2) photovoltaic solar plate takes
aluminum structure to fix, according to solar angle to adjust solar panel angle degree. There is universal
wheels at the bottom of solar board. (3) It can do many experiment circuit and components, students can
combine them to different circuit, do different experiments and training content, and two of them are with
locker. It’s easy to move and fix. (4) Training workbench with safety protection system.
2 Technical parameter
(1) Input power: 220V±10% 50Hz
(2) Dimensions: test box 620*620*180
(3) Training module: 1500mm*800mm*1800mm
(4,) Weight: <225KG
(5) Working conditions: ambient temperature 10 ° C ~ 30 ° C
108