You are on page 1of 3
CERTIFICATE NR 601/27/0A/05/2012/A. OF PRODUCT COMPLIENCE WITH REQUIREMENTS OF STRENGTH AND DURABILITY It is stated that according to the results of executed tests, drawers of the ModernBox system distributed by GTV sp. z 0.0. sp. k. ul. Przejazdowa 21 05-800 Pruszkow meets the following requirements: PN-EN 15338 + A1:2010 /EN 15338:2007 + A1:2010 Hardware for furniture — Strength and durability of extension elements and their component - IDT /. Tests conducted according to EN 15338:2007 + A1:2010, points 4 - 6.3.13, according 3 /highest/ test level. Tests were executed: 16.04.2012 — 07.05.2012 The Certificate contains test report /2 numbered pages’, which are an integral part of the Certificate, Engineering Centre For Creating Signed for and on behalf Product Quality ,ATEST” Ltd “ATEST” Ltd” str. Boguslawskiego 16, 60-214 Poznan tel. 61-8 652 689 DIRE Laboratory in Gruszezyn / Poznan str. Leina 12 Kobylnica E “ini. Lucia Kokorniak Poznan, 07.05.2012 ENGINEERING CENTRE FOR CREATIN PRODUCT QUALITY »ATEST” Ltd Test report number 601/27/0A/05/2012/A. Article tested: drawer of the ModernBox system NL 250 mm Page 1 PN-EN 15338 + A1:2010 /EN 15338:2007 + A1:2010 Hardware for furniture — Strength n elements and their component - IDT /. Parameters of test__ [Test result 6.2 Overload test — the first set 622 | Vertical downwards static overload vertical force 300N, | pass, 10 times the extension element did not detach 62.3 | Horizontal sideways static overload horizontal force pass, 150 N, 5 times the extension element did not detach 62.4 | Outwards static overload horizontal force the extension clement 200N did not detach 625, |Slam-shut/open 1,0 m/s, 10 times pass, the extension element | | did not detach 633 Functional tests — the second set 63.4 | Operating forces force <50N ass, the extension element fulfils its function 635 | 1 vertical downwards static load test | vertical foree 200N, | pass, 10 times | the extension element fulfils its function 63.6 | Thorizontal sideways static load horizontal force pass, 100 N, 5 times the extension element fulfils its function 638 | Durability 60 000 cycles pass, ‘the extension element fulfils its function 63.9 | Deflection of front 1omm pass, <4% 63.10 |2 vertical downwards static load vertical force pass, 200, 10 times the extension element fulfils its function 63.11 |2 horizontal sideways static load horizontal force pass, 100 N, 5 times ‘the extension element fulfils its function 63.12 | Operating forces force <50N pass, the extension element fulfils its function 63.13 | Slam-shutopen 0,5 mis, 10 times pass, the extension element fulfils its function en SRES TSE now ATEST” nasa 60 S%¢ Poznan, ul Gogustawsiego 16 tel ax (061) 65-26-09. ip 779:2061474, eG) PRODUCT QUALITY »ATEST” Ltd Test report number 601/27/0A/05/2012/A Article tested: drawer of the ModernBox system NL 500 mm iGINEERING CENTRE FOR CREATING Page 2 110 JEN 15338:2007 + A1:2010 Hardware for furniture — Strength and durability of extension elements and their component - IDT /. Point of standard Parameters of test [Test result 2 Overload test =the first set 62.2 | Vertical downwards static overload vertical force 300 N, pass, 10 times, the extension element did not detach 62.3 | Horizontal sideways static overload horizontal force pass, 150N, 5 times the extension element did not detach 62.4 | Outwards static overload horizontal force the extension element 200 did not detach 62.5 | Slam-shut/open 1,3 mis, 10 times pass, the extension element - did not detach 63 Functional tests — the second set 63.4 [Operating forces force <50N ass, the extension element fulfils its funtion 63.5. |1 vertical downwards static load test [vertical fore 200, | pass, 10 times the extension element | fulfils its function 63.6 | 1 horizontal sideways static load horizontal force pass, | 100N, 5 times the extension element fulfils its funtion 63.8 | Durability 60 000 eyeles ass, the extension clement L = fulfils its function [639 | Deflection of front 22mm pass, | <4% 63.10 |2 vertical downwards static load vertical force pass, 200.N, 10 times the extension element ae fulfils its faction [63.11 [2 horizontal sideways static Toad horizontal force pass, 100N, 5 times the extension element fulfils its function [63.12 | Operating forces force < 50 N pass, | the extension element fulfils its function 63.13 | Slam-shut/open 0.8 mis, 10 times, pass, | the extension element fulfils its function i Maximal loading capacity drawers of the ModemBox system M = 40 kg, yavensn ognopEe sera OAR baer woROBOW UBTEST™ socio 20.0 cola rosea, ul teptsayaiego 16 telex (061) 605-06 88 ip 779001876, eon E1O6B1995. PREZES—

You might also like