Professional Documents
Culture Documents
TS1000
Seal supply systems | Thermosiphon systems
Functional description
The TS system performs all the basic
functions of a buffer/barrier system for the
operation of double seals:
Features • to pressurize the buffer chamber
With the EagleBurgmann TS1016
• leakage compensation
thermosiphon system it is possible to
supply buffer/barrier fluid to double and
• buffer/barrier fluid is circulated by
thermosiphon effect or forced circulation
tandem mechanical seals for a broad range
system
of applications. The TS1016 thermosiphon
vessel is available in 2 standard sizes with • to cool the seal
flat ends, sight-glasses for level monitoring • to selectively absorb product leakage and
and with or without cooling coil. TS vessels prevent dry running (tandem
are equipped as standard with all the arrangement)
necessary system connections and Use compressed air or nitrogen for
brackets. The modular system allows the pressurization.
TS1016 vessels to be combined with a wide
range of system components such as, e.g.
level switch, circulation pump, hand refill
pump, thermometer, base frame, etc.
eagleburgmann.com All technical specifications are based on extensive tests and our many years of
experience. The diversity of possible applications, however, means that they can serve
info@eagleburgmann.com only as guide values.
We must be notified of the exact conditions of application before we can provide any
guarantee for a specific case. This is subject to change.
28.12.2020 © EagleBurgmann
1
RELY ON EXCELLENCE
Item Description
1 Buffer/barrier fluid IN (G1/2")
2 Buffer/barrier fluid OUT (G1/2")
3 Cooling water IN (pipe 12 x 1.5 mm)
4 Cooling water OUT (pipe 12 x 1.5 mm)
5 Filling connection with cap (G1/2")
6 Pressure gas connection (1/4" NPT)
7 Connection for level switch (G2")
8 Connection for refill unit (G1/8")
9 Connection for pressure gauge (1/4" NPT)
10 Bracket for refill unit
eagleburgmann.com All technical specifications are based on extensive tests and our many years of
experience. The diversity of possible applications, however, means that they can serve
info@eagleburgmann.com only as guide values.
We must be notified of the exact conditions of application before we can provide any
guarantee for a specific case. This is subject to change.
28.12.2020 © EagleBurgmann
2
RELY ON EXCELLENCE
1 Pressure gauge
2 Thermometer
3 Mechanical seal
4 SPU
5 SPN
6 From PCV, we recommend using a reverse controlled pressure control valve (PCV)
5 Level switch
eagleburgmann.com All technical specifications are based on extensive tests and our many years of
experience. The diversity of possible applications, however, means that they can serve
info@eagleburgmann.com only as guide values.
We must be notified of the exact conditions of application before we can provide any
guarantee for a specific case. This is subject to change.
28.12.2020 © EagleBurgmann
3
RELY ON EXCELLENCE
Product variants
Designation TS1016/A003 TS1016/A013 TS1016/A007 TS1016/A008 TS1016/A200
Standard design ■ ■
Design code PED 2014/68/EU PED 2014/68/EU PED 2014/68/EU PED 2014/68/EU PED / EN 13445
Integrated cooling coil ■ ■ ■
Volume of vessel (liters) 4 4 8 8 8
Volume of tube (liters) 0.2 0.2 0.2
Allowable pressure1) 16 bar 16 bar 16 bar 16 bar 16 bar
(232 PSI) (232 PSI) (232 PSI) (232 PSI) (232 PSI)
Allowable temperature1) -60 °C ... +160 °C -60 °C ... +160 °C -60 °C ... +200 °C -60 °C ... +200 °C -60 °C ... +200 °C
(-76 °F ... +320 °F) (-76 °F ... +320 °F) (-76 °F ... +392 °F) (-76 °F ... +392 °F) (-76 °F ... +392 °F)
Working volume, MAX-MIN (liters) 1.2 1.2 1.3 1.3 1.3
Cooling capacity – 0.2 0.2 0.3 0.3 0.3
without cooling water (kW) 2)
Cooling capacity – 1.0 1.2 1.2
natural circulation (kW) 2)
Cooling capacity – 2.0 2.5 2.5
forced circulation (kW) 2)
Metal parts 1.4571 1.4571 1.4571 1.4571 1.4571
Sight-glass Round Borosilicate Round Borosilicate Reflex Borosilicate Reflex Borosilicate Reflex Borosilicate
Seal PTFE PTFE PTFE PTFE PTFE
1) Design data, permissible working values depend on the actual conditions of service.
2) The cooling performance depends on the available fluids, their temperatures and flow rates. Please contact EagleBurgmann for professionally selecting the
correct heat exchanger.
TS1016/A003
eagleburgmann.com All technical specifications are based on extensive tests and our many years of
experience. The diversity of possible applications, however, means that they can serve
info@eagleburgmann.com only as guide values.
We must be notified of the exact conditions of application before we can provide any
guarantee for a specific case. This is subject to change.
28.12.2020 © EagleBurgmann
4
RELY ON EXCELLENCE
TS1016/A007
eagleburgmann.com All technical specifications are based on extensive tests and our many years of
experience. The diversity of possible applications, however, means that they can serve
info@eagleburgmann.com only as guide values.
We must be notified of the exact conditions of application before we can provide any
guarantee for a specific case. This is subject to change.
28.12.2020 © EagleBurgmann
5