Catalogue HY11-2500/UK Check Valve, hydraulically pilot-operated

Characteristics Series RHC

Valve without pre-relief RHC 3/2


The valve element is a ball and guarantees a fast open-
ing of the full flow section diameter A → B during the
opening operation. The switching speed of the spool is
damped. An abrupt opening and, as a result, any relief
shocks are thus prevented to a large extent. If they still
appear during the test run, then an additional throttling
point should be installed in the pilot fluid supply line, or a
valve with pre-relief should be used.

Valve with pre-relief RHC 33V


The valve element is a spherically grinded piston (ball
seat) with integrated ball check valve that is opened al-
ready prior of the main piston during the opening opera-
tion and opens a throttling section diameter for a shock-
free relief of the consumer volume. It should be used
primarily for high operating pressure levels and large
consumer volumes. An additional throttling of the pilot Valve with pre-relief and drain port RHCE 33V
fluid line increases the damping effect of the pre- relief. Function identical with RHC 33V, but with drain port. 6

∆ p/Q performance curves

RHC.PM6.5 RH

Parker Hannifin GmbH


Hydraulic Controls Division
6-23 Kaarst, Germany
Catalogue HY11-2500/UK Check Valve, hydraulically pilot-operated
Technical Data / Ordering Code Series RHC

Technical data
Code RHC 3/2 RHC 33V RHCE 33V
Flow [l/min] 25 55 55
Working pressure pmax [bar] 500 500 500
Pilot ratio psi Main valve 4.5:1 2.5:1 2.5:1
Pre-discharging - 10:1 10:1
Pilot flow volume [cm³] 0.4 0.4 0.4
Tightening torque [Nm] 120 120 120
Material Total steel design, valve side bodypart, hardened, polished valve seat
Mounting Screwed-in intake hole of a body, observe dimension tolerance for thread core
hole D1.
Mounting position as desired
Connections A, B = main passage
Z = pilot oil connection
L = drain port not pressurised to the tank
Flow polarity B → A open; A → B in off position
(connection Z not pressurised) blocked drain-free, when no or lower pilot pres-
sure at B than at A A → B open, when the valve is blocked due to the pilot pres
sure at Z (see also pilot pressure pSt).
Opening pressure [bar] approx. 0.5 (B → A)
p
Pilot pressure pSt [bar] For pilot-operation pSt = ψA + 2.5
(orientation calculation)

to keep it open pSt ≈ pB + p + 4.5
y
y see pilot ratio
pA = pressure at A
pB = pressure at B
∆p/Q performance curves (subsequently)
Pressure fluid Hydraulic oil as per DIN 51 524 TI.1 to 3 ISO VG 10 to 68 as per DIN 51 519

6 Viscosity range
Optimal operation
min. approx. 4; max. approx. 1500 mm²/s
approx. 10...500 mm²/s
Also suitable for biodegradable pressure fluids types HEPG (polyalkylene
glycol) and HEES (synth. Ester) at operating temperatures up to approx. 70°C.
Environmental temperature [°C] approx. -40...+80, oil: -25...+80,
watch out for viscosity range Starting temperature permitted up to -40°C, observe
starting viscosity,if the equilibrium temperature in final operation is at least 20K
higher. Biodegradable pressure fluids: observe manufacturing specifications.
While considering the seal compatibility not over +70°C.

Ordering code

RHC
Hydraulic Flow / design
pilot-operated
check valve

Pilot operation Pilot operation


Flow
Code ratio, main valve ratio, pre-
[l/min]
discharging

3/2 4.5 : 1 - 25
33V 2.5 : 1 10 : 1 55
E33V 2.5 : 1 10 : 1 55

RHC.PM6.5 RH

Parker Hannifin GmbH


6-24 Hydraulic Controls Division
Kaarst, Germany
Catalogue HY11-2500/UK Check Valve, hydraulically pilot-operated
Dimensions Series RHC

Dimensions RHC 3/2

l1
ww l2 O-ring l3

Ød1
Ød2
G4h

20°

¹) D1 is decisive for leakage in the pilot line. Leakage at 300 bar ≈


0.05 l/min, if the tolerances are maintained.
²) The thread depth T1-b and the spacing of the hole Ø D3 (connec-
tion side B) T1-c are dependent on the core hole depth T1. The set Intake hole when using screw plugs DIN 908 and 910 with sealing
dimensions a, b, and c must therefore be maintained. rings as per DIN 7603.

Type G l1 l2 l3 d1 d2 a b c D1 D2 D3 D4 T1 T2 WW O-ring Sealing ring

RHC 3/2 M24 x 1.5 46 13 13.5 22 11 22 15 9 22.4 16 12 29 45 19 10 15.3x2.4 24x29x2

Dimensions RHC 33V

6
l1
l2
ww l3 l4
l5
O-ring 1
80-90
Shore
G

O-ring 2
Control spool sealed

Type G l1 l2 l3 l4 l5 L1 L2 D1 D2 D3 D4 D5 t T1 T2 T3 T4 T5 WW

RHC 33V M26 x 1.5 47 28.5 11 15 7.5 16 40 24 16 12 31 11 0.5 46.5 20 28 25 0.5 10

Type O-ring1 O-ring 2 Sealing ring

RHC 33V 15.3 x 2.4 20.35 x 1.78 26 x 31 x 2

RHC.PM6.5 RH

Parker Hannifin GmbH


Hydraulic Controls Division
6-25 Kaarst, Germany
Catalogue HY11-2500/UK Check Valve, hydraulically pilot-operated
Dimensions Series RHC

Dimensions RHCE 33V

Type G l1 l2 l3 l4 l5 L1 L2 L3 D1 D2 D3 D4 D5 D6 D7 D8 T1 T2
6 RHCE 33V M27x2 59 41.5 14 16 7.5 16 36.5 52 12 16 22.7 23 23.7 24 32 12 59 19

Type T3 T4 T5 T6 T7 T8 WW O-ring1 O-ring2 O-ring3 Sealing ring max. tight. torque (Nm)

RHCE 33V 46 38.5 37.5 29 25 0.5 10 15.3x2.4 18.72x2.62 18x2.5 27x32x2 120

RHC.PM6.5 RH

Parker Hannifin GmbH


6-26 Hydraulic Controls Division
Kaarst, Germany