Professional Documents
Culture Documents
SPIT can only be held responsible if the calculation examples exactly reflect the application and if the installation is carried out according to the instruction given in the SPIT specifications. The calculation is correct for SPIT anchors only. The
contractor or specifier should make sure that the base material is able to support the loads especially in the case of a group of anchors. SPIT cannot be held responsible if this software package is modified without its written approval.
Ref : 10/27/2019 4:35 PM / Software version: 1811 Page : 2/4
Design loading Design and Combined Loading
Tensile forces per anchor: Recommended anchors:
Loads on anchors: FIX Z XTREM M12x180/85
Anchor (X,Y) Tensile Shear[x] Shear[y] ETA nb: ETA-15/0388
1 (-65,25) 10.4 kN 0 kN 0 kN Issue: 02/23/2016
2 (65,25) 10.4 kN 0 kN 0 kN
Anchor X Y
1 -65 25
2 65 25
Ref : 10/27/2019 4:35 PM / Software version: 1811 Page : 4/4
Recommended anchors: FIX Z XTREM M12x180/85
Product Code: 057779 / ETA nb: ETA-15/0388 / Issue: 02/23/2016
Installation data:
Effective depth: 70 mm
Minimum thickness of base material: 213 mm
Hole diameter in the base material: 12 mm
Hole depth in the base material: 163 mm
Installation torque: 60.00 Nm
Anchor plate, steel quality : S235
Base plate thickness: 12 mm
Profile family (Section type) : Flat Bars110x12
Clearance diameter: 14 mm
Installation method: