You are on page 1of 7

Ref : 21/09/2022 - 17:24:58 / Version 2021.09.

09
Date : 21/09/2022
Page : 1/7

CALCULATION SHEET FOR RAMSET ANCHORS


Company : Henry and Hymas Consulting Engineers Phone number : 0294178400
Carried out by : Eusuf Iqbal Mail address : eiqbal@hhconsult.com.au
Company : Project name : 20B36
Contact name : Location :
Phone number : Fastening point : footpath support
Mail address :
Comment :

Recommended anchors
ChemSet Reo 502 Plus + ChemSet Anchor Studs Hdg Gr5.8 M16x190 Effective embedment : 80 mm

ETA-18/0675 issued 2021/06/06

Base material
Concrete resistance : 32 Mpa
Cracking of concrete : Cracked concrete
Thickness of concrete : 180 mm
Reinforcement type : Wide concrete reinforcement
Edge reinforcement : Straight edge reinforcement

Conditions
Installation conditions : Dry concrete
Short term temperature : 40 °C
Long term temperature : 24 °C

Anchor plate
Thickness of part to be fixed : 10 mm
Recommended plate thickness : The base plate thickness has not been checked

Clearance diameter : 18 mm
Profile : 150 UB 18.0
Profile position : Ex = 0 mm ; Ey = 0 mm
Stand-off : None

Design method : AS 5216:2018 Design for static, quasi-static loading


Design Actions :

Dimension L : 25 mm
Lg position of gravity center: 25 mm

Weight P : 0 kg
Action F : 68 kN
Action NR : 0 kN

Working life : 0
Ref : 21/09/2022 - 17:24:58 / Version 2021.09.09
Date : 21/09/2022
Page : 2/7

Geometry :

Calculation Hypothesis :

- The anchoring plate is assumed to be sufficient to resist deformation imposed by the load actions.

- Connection between profile and base plate has not been checked

- RAMSET can only be held responsible if the calculation examples exactly reflect the application and if the installation is
carried out according to the instruction given in the RAMSET specifications. The calculation is correct for RAMSET anchors
only. The
contractor or specifier should make sure that the base material is able to support the loads especially in the case of a group of
anchors. RAMSET cannot be held responsible if this software package is modified without its written approval.
Ref : 21/09/2022 - 17:24:58 / Version 2021.09.09
Date : 21/09/2022
Page : 3/7

Resulting anchors forces

Loads on anchors

Anchor Tensile Shear[x] Shear[y]


1 0 kN 0 kN -17 kN
2 0 kN 0 kN -17 kN
3 4.09 kN 0 kN -17 kN

4 4.09 kN 0 kN -17 kN

* * eNx [mm] eNy [mm]


Ng [kN] Nh [kN]

8.19 4.09 0 0

* *
Vg [kN] Vh [kN]

68 17

Utilization

Tension load Tension force [kN] Strength [kN]


Combined pullout-concrete cone failure 8.19 46.94 17.4
Concrete cone failure 8.19 37.14 22.0

Splitting failure 8.19 44.11 18.6


Steel failure 4.09 51.35 8.0

Shear load Shear force [kN] Strength [kN]


Concrete Edge failure 34 97.97 34.71
Pryout failure 68 84.69 80.29
Steel failure 17 31.2 54.49

Combined tension and shear loads

THE APPLICATION IS SAFE


Ref : 21/09/2022 - 17:24:58 / Version
Date : 2021.09.09
21/09/2022
Page : 4/7

CALCULATION DETAILS

Tension load - Combined pullout-concrete cone failure

Tension load - Concrete cone failure


Ref : 21/09/2022 - 17:24:58 / Version 2021.09.09
Date : 21/09/2022
Page : 5/7

Tension load - Splitting failure

Tension load - Steel failure


Ref : 21/09/2022 - 17:24:58 / Version 2021.09.09
Date : 21/09/2022
Page : 6/7

Shear load - Concrete edge failure

Shear load - Pryout failure

Shear load - Steel failure


Ref : 21/09/2022 - 17:24:58 / Version 2021.09.09
Date : 21/09/2022
Page : 7/7

INSTALLATION DATA

ChemSet Reo 502 Plus + ChemSet Anchor Studs Hdg Gr5.8 M16x190 Effective embedment : 80 mm

ETA-18/0675 issued 2021/06/06

Effective embedment : 80 mm
Minimum thickness of base material : 116 mm
Hole diameter in the base material : 18 mm
Hole depth in the base material : 80 mm
Installation torque : 95.00 Nm
Base plate thickness : 10 mm
Profile family (section type) : 150 UB 18.0
Clearance diameter : 18 mm

INSTALLATION Method