You are on page 1of 7

Ref : 9/28/2022 - 12:46:57 PM / Version 2021.10.

12
Date : 9/28/2022
Page : 1/7

CALCULATION SHEET FOR SPIT ANCHORS


Company : Phone number :
Carried out by : Mail address :
Company : Project name :
Contact name : Location :
Phone number : Fastening point :
Mail address :

Comment :

Recommended anchors
VIPER XTREM + Threaded stud Zn 8.8 / HDG 8.8 M20 / hef = 140 mm Product Code: 060189

Effective embedment : 140 mm


ETA-17/0514 issued 2017/12/13

Base material
Concrete resistance : C40/50
Cracking of concrete : Cracked concrete
Thickness of concrete : 450 mm
Reinforcement type : Wide concrete reinforcement
Edge reinforcement : No edge reinforcement

Conditions
Installation conditions : Dry concrete
Short term temperature : 40 °C
Long term temperature : 24 °C

Anchor plate
Thickness of part to be fixed : 20 mm
Recommended plate thickness : The base plate thickness has not been checked

Clearance diameter : 22 mm
Profile :
Profile position : Ex = 0 mm ; Ey = 0 mm
Stand-off : None

Design method : EN 1992-4 for static, quasi-static loading


Design Actions :

Action [kN] / [kNm] Action type

Combination 1 standard 0 0 -6 2.5 14 0

Specifications :
Static
Sustained Load : False
Ref : 9/28/2022 - 12:46:57 PM / Version 2021.10.12
Date : 9/28/2022
Page : 2/7

Geometry :

Calculation Hypothesis :
- The anchoring plate is assumed to be sufficient to resist deformation imposed by the load actions.
- Connection between profile and base plate has not been checked
- The calculation is done acc. to expert judgement, based on EN 1992-4

- SPIT can only be held responsible if the calculation examples exactly reflect the application and if the installation is carried out
according to the instruction given in the SPIT specifications. The calculation is correct for SPIT anchors only. The
contractor or specifier should make sure that the base material is able to support the loads especially in the case of a group of
anchors. SPIT cannot be held responsible if this software package is modified without its written approval.
Ref : 9/28/2022 - 12:46:57 PM / Version 2021.10.12
Date : 9/28/2022
Page : 3/7

Resulting anchors forces

Loads on anchors

Anchor Tensile Shear[x] Shear[y]


1 0 kN 5 kN -1.5 kN
2 5.51 kN 1.67 kN -1.5 kN
3 11.22 kN -1.67 kN -1.5 kN

4 16.94 kN -5 kN -1.5 kN

33.67 16.94 0 50.9

14.92 5.22

Utilization

Tension load Tension force [kN] Strength [kN]


Combined pullout-concrete cone failure 33.67 46.97 71.7
Concrete cone failure 33.67 59.22 56.9
Splitting failure 33.67 126.16 26.7

Steel failure 16.94 130.67 13.0

Shear load Shear force [kN] Strength [kN]


Concrete Edge failure 8.97 37.7 23.79
Pryout failure 5.22 35.55 14.68
Steel failure 5.22 78.4 6.66

Combined tension and shear loads

THE APPLICATION IS SAFE


Ref : 9/28/2022 - 12:46:57 PM / Version 2021.10.12
Date : 9/28/2022
Page : 4/7

CALCULATION DETAILS

Tension load - Combined pullout-concrete cone failure

Tension load - Concrete cone failure


Ref : 9/28/2022 - 12:46:57 PM / Version 2021.10.12
Date : 9/28/2022
Page : 5/7

Tension load - Splitting failure

Tension load - Steel failure


Ref : 9/28/2022 - 12:46:57 PM / Version 2021.10.12
Date : 9/28/2022
Page : 6/7

Shear load - Concrete edge failure

Shear load - Pryout failure

Shear load - Steel failure


Ref : 9/28/2022 - 12:46:57 PM / Version 2021.10.12
Date : 9/28/2022
Page : 7/7

INSTALLATION DATA

VIPER XTREM + Threaded stud Zn 8.8 / HDG 8.8 M20 / hef = 140 mm Product Code: 060189
Effective embedment : 140 mm
ETA-17/0514 issued 2017/12/13

Minimum stud length: 179.5 mm


Effective embedment : 140 mm
Minimum thickness of base material : 190 mm
Hole diameter in the base material : 25 mm
Hole depth in the base material : 140 mm
Installation torque : 120.00 Nm
Base plate thickness : 20 mm
Profile family (section type) :
Clearance diameter : 22 mm

INSTALLATION Method