You are on page 1of 7

C-FIX 1.109.0.

0
Database version
2022.6.9.13.4
Date
08/01/2023

fischer FZE

Jebel Ali Free Zone Warehouse No XB


P.O. Box 261738 Dubai

Enquiry@fischer.ae
www.fischer.ae

Design Specifications
Anchor
Anchor system fischer Bolt anchor FAZ II
Anchor Bolt anchor FAZ II 16/5,
zinc plated steel
Calculated anchorage 65 mm
depth
Design Data Anchor design in Concrete according European Technical
Assessment ETA-05/0069, Option 1,
Issued 24/04/2020

Geometry / Loads / Scale units


mm, kN, kNm

Value of design actions (including

partial safety factor for the load) Static

Not drawn to scale

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 1
C-FIX 1.109.0.0
Database version
2022.6.9.13.4
Date
08/01/2023

Input data

Design method TR055/ETAG 001, Annex C, Method A


Base material C40/50, EN 206
Concrete condition Cracked, dry hole
Reinforcement No or standard reinforcement. Straight edge reinforcement.
With reinforcement against splitting
Drilling method Hammer drilling
Installation type Push-through installation
Annular gap Annular gap not filled
Type of loading Permanent-Transient/Static
Base plate location Base plate flush installed on base material
Base plate geometry 130 mm x 170 mm x 16 mm
Profile type Customized profile

Design actions *⁾
# NSd VSd,x VSd,y MSd,x MSd,y MT,Sd Type of loading
kN kN kN kNm kNm kNm
1 0.00 -3.00 3.00 0.00 0.00 0.00 Permanent-Transient/Static

*⁾ The required partial safety factors for actions are included

Resulting anchor forces


Tensile action Shear Action Shear Action x Shear Action y
Anchor no. kN kN kN kN
1 0.00 2.12 -1.50 1.50
2 0.00 2.12 -1.50 1.50

max. concrete compressive strain : ‰


max. concrete compressive stress : N/mm²
Resulting tensile actions : kN , X/Y position ( / )
Resulting compression actions : kN , X/Y position ( / )

Resistance to shear loads

Proof Action Capacity Utilisation βV


kN kN %
Steel failure without lever arm * 2.12 44.00 4.8
Concrete pry-out failure 4.24 89.02 4.8
Concrete edge failure 4.24 40.22 10.5

* Most unfavourable anchor

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 2
C-FIX 1.109.0.0
Database version
2022.6.9.13.4
Date
08/01/2023

Steel failure without lever arm

( VRd,s )

VRk,s γMs VRd,s VSd βVs


kN kN kN %
55.00 1.25 44.00 2.12 4.8

βVs
Anchor no. % Group N° Decisive Beta
1 4.8 1 βVs;1
2 4.8 2 βVs;2

Concrete pry-out failure

( VRd,cp )

Eq. (5.6)

Eq. (5.2)

Eq. (5.2a)

Eq. (5.2c)

Eq. (5.2d)

Eq. (5.2e)

VRk,cp γMc VRd,cp VSd βV,cp


kN kN kN %
133.54 1.50 89.02 4.24 4.8

βV,cp
Anchor no. % Group N° Decisive Beta
1, 2 4.8 1 βV,cp;1

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 3
C-FIX 1.109.0.0
Database version
2022.6.9.13.4
Date
08/01/2023

Concrete edge failure

( VRd,c )

Eq. (5.7)

Eq. (5.7a)

Eq. (5.7b/c)

Eq. (5.7e)

Eq. (5.7f)

Eq. (5.7g)

Eq. (5.7h)

VRk,c γMc VRd,c VSd βV,c


kN kN kN %
60.33 1.50 40.22 4.24 10.5

βV,c
Anchor no. % Group N° Decisive Beta
1, 2 10.5 1 βV,c;1

Resistance to combined tensile and shear loads

Proof successful (5.8b)

Information concerning the anchor plate


Base plate details
Plate thickness specified by user without proof t = 16 mm
The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 4
C-FIX 1.109.0.0
Database version
2022.6.9.13.4
Date
08/01/2023

Profile type Customized profile

Technical remarks
All data and information in the software is based on fischer products and common engineering knowledge. Please
check all the proof results against local valid standards and approvals.
As fischer is not the design office, the attached is no guarantee for incorrect input or assumptions. Any
recommendations have to be approved by the building-authority or project engineer. Results are valid only for
anchor system calculated in the attached. If any part of the system is changed, it will invalidate this report and new
calculations would be required. The calculation was done under the assumption that a sufficient
splitting reinforcement is available. In this case the spliiting
failure can be omitted.
The transmission of the anchor loads to the supports of the concrete member shall be shown for the ultimate limit state and
the serviceability limit state; for this purpose, the normal verifications shall be carried out under due consideration of the
actions introduced by the anchors. For these verifications the additional provisions given in the current design method shall
be taken into account.
As a pre-condition the anchor plate is assumed to be flat when subjected to the actions. Therefore, the plate (if present) must
be sufficiently stiff. The C-Fix anchor plate design is based on a proof of stresses and does not allow a statement about the
stiffness of the plate. The proof of the necessary stiffness is not carried out by C-Fix.

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 5
C-FIX 1.109.0.0
Database version
2022.6.9.13.4
Date
08/01/2023

Installation data
Anchor
Anchor system fischer Bolt anchor FAZ II
Anchor Bolt anchor FAZ II 16/5, Art.-No. 522124
zinc plated steel

Accessories Blow-out pump ABG big Art.-No. 89300


SDS Plus-V II 16/160/210 Art.-No. 531827
or alternatively
FHD 16/250/380 Art.-No. 546599
Hammer drilling with or without
suction

Installation details
Thread diameter M 16
Drill hole diameter d0 = 16 mm
Drill hole depth h2 = 113 mm
Calculated anchorage hef = 65 mm
depth
Installation depth hnom = 83 mm
Drilling method Hammer drilling
Drill hole cleaning Only blow out by hand
No borehole cleaning required in
case of using a hollow drill bit, e.g.
fischer FHD.
Installation type Push-through installation
Annular gap Annular gap not filled
Installation torque Tinst = 110.0 Nm
Socket size 24 mm
Base plate thickness t = 16 mm
Total fixing thickness tfix = 16 mm
Tfix,max tfix, max = 25 mm

Base plate details


Base plate material S 235 (St 37)
Base plate thickness t = 16 mm
Clearance hole in base df=18 mm
plate

Attachment
Profile type Customized profile
Distance between profiles 80 mm

Profile dimensions mm
Height 10

Anchor coordinates

x y
Anchor no. mm mm
1 0 55
2 0 -55

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 6
C-FIX 1.109.0.0
Database version
2022.6.9.13.4
Date
08/01/2023

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 7

You might also like