You are on page 1of 4

Ref : 3/22/2023 - 11:09:52 AM / Version 2022.11.

04
Date : 3/22/2023
Page : 1/4

CALCULATION SHEET FOR RAMSET ANCHORS


Company : Phone number :
Carried out by : Mail address :
Company : Verbrec Project name : Bowden Rd Bund Assessment
Contact name : Z Zhang Location : 28 Bowden Road
Phone number : 02902097341 Fastening point : 11-01555.00
Mail address :

Comment :

Recommended anchors Product Code: NA


EPCON C6 Plus + Typ. Threaded Rod Grade 8.8 M20 / hef = 205 mm Effective embedment : 205 mm
ETA-18/0675 issued 2021/06/06
For self Cleaning: Use Ramset Dustless Drilling System
methodAdhesive Part Number: REO502J or REO502JEF
Base material
Concrete resistance : C35/45 - fck,cyl = 35 N/mm²
Cracking of concrete : Cracked concrete
Thickness of concrete : 600 mm
Reinforcement type : Wide concrete reinforcement
Edge reinforcement : No edge reinforcement

Conditions
Installation conditions : Dry concrete
Short term temperature : 40 °C
Long term temperature : 24 °C

Anchor plate
Thickness of part to be fixed : 25 mm
Recommended plate thickness : The base plate thickness has not been checked

Clearance diameter : 22 mm
Profile : 310 UB 40.4
Profile position : Ex = 0 mm ; Ey = 0 mm
Stand-off : None

Design method : European/NZS 3101 for seismic loading


Design Actions :

Action [kN] / [kNm] Action type

Combination 1 seismic 0 54 54 0 0 0

Specifications :
Seismic category : C1
Structural Elements
Working life : 50 years
Building importance class: II
Seismicity level (AS 5216:2021 - Table F.3.1): ag.S ≤ 0,05.g
No filled holes
Design options::
Ref : 3/22/2023 - 11:09:52 AM / Version 2022.11.04
Date : 3/22/2023
Page : 2/4

Geometry :

Calculation Hypothesis :
- The anchoring plate is assumed to be sufficient to resist deformation imposed by the load actions.
- Connection between profile and base plate has not been checked

- RAMSET can only be held responsible if the calculation examples exactly reflect the application and if the installation is carried
out according to the instruction given in the RAMSET specifications. The calculation is correct for RAMSET anchors only. The
contractor or specifier should make sure that the base material is able to support the loads especially in the case of a group of
anchors. RAMSET cannot be held responsible if this software package is modified without its written approval.
Ref : 3/22/2023 - 11:09:52 AM / Version 2022.11.04
Date : 3/22/2023
Page : 3/4

Resulting anchors forces

Loads on anchors

Anchor Tensile Shear[x] Shear[y]


1 0 kN 13.5 kN 13.5 kN
2 0 kN 13.5 kN 13.5 kN
3 0 kN 13.5 kN 13.5 kN

4 0 kN 13.5 kN 13.5 kN

0 0 0 0

76.37 19.09

Utilization

Tension load Tension force [kN] Strength [kN]


Combined pullout-concrete cone failure / / /
Concrete cone failure / / /
Splitting failure / / /

Steel failure / / /

Shear load Shear force [kN] Strength [kN]


Concrete Edge failure / / /
Pryout failure 76.37 78.21 97.64
Steel failure 19.09 21.76 87.74

Combined tension and shear loads

THE APPLICATION IS SAFE


Ref : 3/22/2023 - 11:09:52 AM / Version 2022.11.04
Date : 3/22/2023
Page : 4/4

INSTALLATION DATA

EPCON C6 Plus + Typ. Threaded Rod Grade 8.8 M20 / hef = 205 mm Product Code: NA
Effective embedment : 205 mm
ETA-18/0675 issued 2021/06/06

Minimum stud length: 249.5 mm


Effective embedment : 205 mm
Minimum thickness of base material : 249 mm
Hole diameter in the base material : 22 mm
Hole depth in the base material : 205 mm
Installation torque : 180.00 Nm
Base plate thickness : 25 mm
Profile family (section type) : 310 UB 40.4
Clearance diameter : 22 mm

INSTALLATION Method

You might also like