You are on page 1of 17

Structural Calculation Report

Project:
B+G+1 RESIDENTIAL BUILDING
SKY LIGHT DESIGN CALCULATION

SKYLIGHT -2
Rev.00
TABLE OF CONTENTS

B+G+1 RESIDENTIAL BUILDING PROJECT-

535....................................................................................................................................................... 1

1 MATERIAL PROPERTIES

............................................................................................................................................................. 2

1.1 Design of Member: BS 5950-1

.............................................................................................................................................................2

1.2 Structural Fasteners

............................................................................................................................................................ 2

1.3 Glass (AAMA Structural Properties of Glass)

........................................................................................................................................................... 2

1.4 Anchors

............................................................................................................................................................2

2 Wind load

........................................................................................................................................................... 3

3 DESIGN OF

GLASS.............................................................................................................................................. 4

3.1 Vision Glass

.......................................................................................................................................................... 4

4 Skylight analysis

......................................................................................................................................................... 5

5 Analysis result:

........................................................................................................................................................ 8

6 Connection

check:............................................................................................................................................ 9

6.1 Anchor design

....................................................................................................................................................... 9
1 MATERIAL PROPERTIES
1.1 Design of Member: BS 5950-1
1.1.1 Bracket material: BS5950-1
For designing the bracket, Aluminium
For the elastic properties of steel, the following values should be used
Modulus of elasticity: E=200000 N/mm2
Shear Modulus: G=E/ [2(1+v)]
Poisson’s ratio: v=0.3
Coefficient of thermal expansion: α=11.5x10-6 per o C
1.2 Structural Fasteners
1.2.1 AAMA TIR-A9-91 Metal Curtain Wall Fasteners

1.3 Glass (AAMA Structural Properties of Glass)


Modulus of elasticity = 72000 mPa
Coefficient of thermal expansion = 88x10-7 / deg. C
Density = 2500 kg/m3
Poisson’s ratio = 0.22

1.4 Anchors
Design as per ETAG
3 DESIGN OF GLASS
Glass has been designed according to ASTM E 1300 Standard Practice for Determining Load
Resistance of
Glass in Buildings. Input and results from Windows Glass Design are presented below.

3.1 Vision Glass


3.1.1 Check against Wind Load +Dead load

Figure 1: Input and output data from Window Glass Design


LR (load resistance) >1.53kPa therefore OK
Deflection = 12.5mm < b/60; Hence OK As per AS standard
4 Skylight analysis
Self-weight software taken automatically
Dead load (6+1.52+6) +14+6 mm thick glass=0.45Kpa
Tributary width 1=3.06/2+2.4/2=2.73m
Tributary width 2=2.4/2+2.4/2=2.4m
Applied load 1-0.45x2.73=1.1kN/m
Applied load 2-0.45x2.4=0.91kN/m
Wind load:
Typical wind load=1.05Kpa
Applied load 1-1.05*2.73=2.87KN/m
Applied load 2-1.05*2.4=2.52KN/m
Chandler load-1.5

4.1.1 Geometry: 190X50 ALUMINIUM


Figure 2: Member geometry-Mullion

4.1.2 Applied load

Figure 3: Chandler light


Figure 4: Dead load of glass

Figure 5: Wind load downward direction


Figure 6: Wind load Upward direction

Figure 7: Utility ratio


Figure 8: Actual deflection
Actual deflection from the software analysis δact=7.53mm
Allowable deflection δall=min (L/240) =7.75mm >7.53mm. Hence OK

Figure 9: Maximum Reaction

6.1 Anchor design


Fx=1.144kN
Fy=22.167kN
Fz=-0.43kN
C-FIX 1.66.0.0
Database version
2018.1.23.12.1
Date
19/12/2019

APPENDIX-B

fischer FZE

Jebel Ali Free Zone Warehouse No XB


01
P.O. Box 261738 Dubai

Enquiry@fischer.ae
www.fischer.ae

Design Specifications
Anchor
Anchor system fischer Bolt anchor FAZ II
Anchor Bolt anchor FAZ II 10/10, zinc plated steel
Anchorage depth 60 mm
Design Data Anchor design in Concrete according European Technical
Assessment ETA-05/0069, Option 1,
Issued 03/07/2017

Geometry / Loads / Scale units


mm, kN, kNm

Value of design actions (including

partial safety factor for the load) Static

Not drawn to scale

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 1
C-FIX 1.66.0.0
Database version
2018.1.23.12.1
Date
19/12/2019

Input data

Design method TR055/ETAG 001, Annex C, Method A


Base material Normal weight concrete, C35/45, EN 206
Concrete condition Non-cracked, dry hole
Reinforcement Normal or no reinforcement. No edge reinforcement
Drilling method hammer drilling
Installation type Push-through installation
Annular gap Annular gap not filled
Type of loading Static or quasi-static
Base plate location Base plate flush installed on base material
Base plate geometry 150 mm x 200 mm x 10 mm
Profile type Customized profile

Design actions *⁾
# NSd VSd,x VSd,y MSd,x MSd,y MT,Sd Type of loading
kN kN kN kNm kNm kNm
1 -17.00 4.10 9.30 0.00 0.00 0.00 Static or quasi-static

*⁾ The required partial safety factors for actions are included

Resulting anchor forces


Tensile action Shear Action Shear Action x Shear Action y
Anchor no. kN kN kN kN
1 0.00 1.88 0.51 1.81
2 0.00 2.88 0.51 2.84
3 0.00 2.38 1.54 1.81
4 0.00 3.23 1.54 2.84

max. concrete compressive strain : 0.04 ‰


max. concrete compressive stress : 1.5 N/mm²
Resulting tensile actions : 0.00 kN , X/Y position ( 0 / 0 )
Resulting compression actions : 17.00 kN , X/Y position ( 0 / -50 )

Resistance to shear loads

Proof Action Capacity Utilisation βV


kN kN %
Steel failure without lever arm * 3.23 17.12 18.9
Concrete pry-out failure 10.16 101.25 10.0
Concrete edge failure 9.36 17.17 54.5

* Most unfavourable anchor

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 2
C-FIX 1.66.0.0
Database version
2018.1.23.12.1
Date
19/12/2019

Steel failure without lever arm

( VRd,s )

VRk,s γMs VRd,s VSd βVs


kN kN kN %
21.40 1.25 17.12 3.23 18.9

βVs
Anchor no. % Group N° Decisive Beta
1 11.0 1 βVs;1
2 16.8 2 βVs;2
3 13.9 3 βVs;3
4 18.9 4 βVs;4

Concrete pry-out failure

( VRd,cp )

Eq. (5.6)

Eq. (5.2)

Eq. (5.2a)

Eq. (5.2c)

Eq. (5.2d)

Eq. (5.2e)

VRk,cp γMc VRd,cp VSd βV,cp


kN kN kN %
151.87 1.50 101.25 10.16 10.0

βV,cp
Anchor no. % Group N° Decisive Beta
1, 2, 3, 4 10.0 1 βV,cp;1

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 3
C-FIX 1.66.0.0
Database version
2018.1.23.12.1
Date
19/12/2019

Concrete edge failure

( VRd,c )

Eq. (5.7)

Eq. (5.7a)

Eq. (5.7b/c)

Eq. (5.7e)

Eq. (5.7f)

Eq. (5.7g)

Eq. (5.7h)

VRk,c γMc VRd,c VSd βV,c


kN kN kN %
25.76 1.50 17.17 9.36 54.5

βV,c
Anchor no. % Group N° Decisive Beta
1, 2 54.5 1 βV,c;1
3, 4 25.1 2 βV,c;2

Resistance to combined tensile and shear loads

Proof successful (5.8b)

Information concerning the anchor plate


Base plate details
Plate thickness specified by user without proof t = 10 mm

Profile type Customized profile


The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 4
C-FIX 1.66.0.0
Database version
2018.1.23.12.1
Date
19/12/2019

Technical remarks
All data and information in the software is based on fischer products and common engineering knowledge. Please
check all the proof results against local valid standards and approvals.
As fischer is not the design office, the attached is no guarantee for incorrect input or assumptions. Any
recommendations have to be approved by the building-authority or project engineer. Results are valid only for
anchor system calculated in the attached. If any part of the system is changed, it will invalidate this report and new
calculations would be required.
The transmission of the anchor loads to the supports of the concrete member shall be shown for the ultimate limit state and
the serviceability limit state; for this purpose, the normal verifications shall be carried out under due consideration of the
actions introduced by the anchors. For these verifications the additional provisions given in the current design method shall
be taken into account.
As a pre-condition the anchor plate is assumed to be flat when subjected to the actions. Therefore, the plate must be
sufficiently stiff. The C-Fix anchor plate design is based on a proof of stresses and does not allow a statement about
the stiffness of the plate. The proof of the necessary stiffness is not carried out by C-Fix.

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 5
C-FIX 1.66.0.0
Database version
2018.1.23.12.1
Date
19/12/2019

Installation data
Anchor
Anchor system fischer Bolt anchor FAZ II
Anchor Bolt anchor FAZ II 10/10, zinc Art.-No. 94981
plated steel

Accessories Blow-out pump ABG big Art.-No. 89300


Hammer drill bit SDS Plus IV Art.-No. 504140
10/100/160

Installation details
Thread diameter M 10
Drill hole diameter d0 = 10 mm
Drill hole depth h2 = 87 mm
Anchorage depth hef = 60 mm
Drilling method hammer drilling
Drill hole cleaning only blow out by hand
Installation type Push-through installation
Annular gap Annular gap not filled
Installation torque Tinst = 45.0 Nm
Socket size 17 mm
Base plate thickness t = 10 mm
Total fixing thickness tfix = 10 mm
Tfix,max tfix, max = 10 mm

Base plate details


Base plate material Not available
Base plate thickness t = 10 mm
Clearance hole in base df=12 mm
plate

Attachment
Profile type Customized profile

Profile dimensions mm
Height 100
Width 50
Flange thickness 3

Anchor coordinates

x y
Anchor no. mm mm
1 -50 50
2 50 50
3 -50 -50
4 50 -50