You are on page 1of 8

C-FIX 1.99.0.

0
Database version
2021.4.3.17.13
Date
17/06/2021

fischer Building Materials India PVT


Ltd.

Prestige Garnet Unit NO- 401, 4th Floor


36, Ulsoor Road
560042 Bengaluru
Phone: +91 08 04 15 11 99 12 01
info@fischer.in
www.fischer.in

Design Specifications
Anchor
Anchor system fischer Bolt anchor FAZ II
Anchor Bolt anchor FAZ II 8/5 K R,
stainless steel
Calculated anchorage 35 mm
depth
Design Data Anchor design in Concrete according European Technical
Assessment ETA-05/0069, Option 1,
Issued 24/04/2020

Geometry / Loads / Scale units


mm, kN, kNm

Value of design actions (including

partial safety factor for the load) Static

Not drawn to scale

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 1
C-FIX 1.99.0.0
Database version
2021.4.3.17.13
Date
17/06/2021

Input data

Design method Design Method EN1992-4:2018 mechanical fastener


Base material C20/25, EN 206
Concrete condition Non-cracked, dry hole
Reinforcement Normal or no reinforcement. No edge reinforcement
Drilling method Hammer drilling
Installation type Push-through installation
Annular gap Annular gap not filled
Type of loading Permanent-Transient/Static
Base plate location Base plate flush installed on base material
Base plate geometry 36 mm x 1,400 mm x 5 mm
Profile type None

Design actions *⁾
# NEd VEd,x VEd,y MEd,x MEd,y MT,Ed Type of loading
kN kN kN kNm kNm kNm
1 1.10 5.40 0.00 0.00 0.00 0.00 Permanent-Transient/Static

*⁾ The required partial safety factors for actions are included

Resulting anchor forces


Tensile action Shear Action Shear Action x Shear Action y
Anchor no. kN kN kN kN
1 0.55 2.70 2.70 0.00
2 0.55 2.70 2.70 0.00

max. concrete compressive strain : 0.00 ‰


max. concrete compressive stress : 0.0 N/mm²
Resulting tensile actions : 1.10 kN , X/Y position ( 0 / 0 )
Resulting compression actions : 0.00 kN , X/Y position ( 0 / 0 )

Resistance to tension loads

Action Capacity Utilisation βN


Proof kN kN %
Steel failure * 0.55 11.33 4.9
Pullout failure * 0.55 9.33 5.9
Concrete cone failure 0.55 6.79 8.1

* Most unfavourable anchor

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 2
C-FIX 1.99.0.0
Database version
2021.4.3.17.13
Date
17/06/2021

Steel failure

( NRd,s )

NRk,s γMs NRd,s NEd βN,s


kN kN kN %
17.00 1.50 11.33 0.55 4.9

βN,s
Anchor no. % Group N° Decisive Beta
1 4.9 1 βN,s;1
2 4.9 2 βN,s;2

Pullout failure

( NRd,p )

NRk,p Ψc γMp NRd,p NEd βN,p


kN kN kN %
14.00 1.000 1.50 9.33 0.55 5.9

The given Psi,c-factor may has been determined by interpolation.

βN,p
Anchor no. % Group N° Decisive Beta
1, 2 5.9 1 βN,p;1

Concrete cone failure

( NRd,c )

Eq. (7.1)

Eq. (7.2)

Eq. (7.4)

Eq. (7.5)

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 3
C-FIX 1.99.0.0
Database version
2021.4.3.17.13
Date
17/06/2021

Eq. (7.6)

Eq. (7.7)

NRk,c γMc NRd,c NEd βN,c


kN kN kN %
10.19 1.50 6.79 0.55 8.1

βN,c
Anchor no. % Group N° Decisive Beta
1 8.1 1 βN,c;1
2 8.1 2 βN,c;2

Resistance to shear loads

Proof Action Capacity Utilisation βV


kN kN %
Steel failure without lever arm * 2.70 13.44 20.1
Concrete pry-out failure 2.70 16.98 15.9
Concrete edge failure 2.70 10.03 26.9

* Most unfavourable anchor

Steel failure without lever arm

( VRd,s )

Eq. (7.35)/
(7.36)

VRk,s γMs VRd,s VEd βVs


kN kN kN %
16.80 1.25 13.44 2.70 20.1

βVs
Anchor no. % Group N° Decisive Beta
1 20.1 1 βVs;1
2 20.1 2 βVs;2

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 4
C-FIX 1.99.0.0
Database version
2021.4.3.17.13
Date
17/06/2021

Concrete pry-out failure

( VRd,cp )

Eq. (7.39a)

Eq. (7.1)

Eq. (7.2)

Eq. (7.4)

Eq. (7.5)

Eq. (7.6)

Eq. (7.7)

VRk,cp γMc VRd,cp VEd βV,cp


kN kN kN %
25.47 1.50 16.98 2.70 15.9

βV,cp
Anchor no. % Group N° Decisive Beta
1 15.9 1 βV,cp;1
2 15.9 2 βV,cp;2

Concrete edge failure

( VRd,c )

Eq. (7.40)

Eq. (7.41)

Eq.
(7.42/7.43)

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 5
C-FIX 1.99.0.0
Database version
2021.4.3.17.13
Date
17/06/2021

Eq. (7.45)

Eq. (7.46)

Eq. (7.48)

Eq. (7.47)

VRk,c γMc VRd,c VEd βV,c


kN kN kN %
15.04 1.50 10.03 2.70 26.9

βV,c
Anchor no. % Group N° Decisive Beta
1 26.9 1 βV,c;1
2 26.9 2 βV,c;2

Utilization of tension and shear loads

Tension loads Utilisation βN Shear Loads Utilisation βV


% %
Steel failure * 4.9 Steel failure without lever arm * 20.1
Pullout failure * 5.9 Concrete pry-out failure 15.9
Concrete cone failure 8.1 Concrete edge failure 26.9

* Most unfavourable anchor

Resistance to combined tensile and shear loads


Utilisation steel

Eq. (7.55)

Utilisation concrete Proof successful

Eq. (7.56)

Information concerning the anchor plate


Base plate details
Plate thickness specified by user without proof t = 5 mm

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 6
C-FIX 1.99.0.0
Database version
2021.4.3.17.13
Date
17/06/2021

Profile type None

Technical remarks
The transmission of the anchor loads to the supports of the concrete member shall be shown for the ultimate limit state and
the serviceability limit state; for this purpose, the normal verifications shall be carried out under due consideration of the
actions introduced by the anchors. For these verifications the additional provisions given in the current design method shall
be taken into account.
As a pre-condition the anchor plate is assumed to be flat when subjected to the actions. Therefore, the plate (if present) must
be sufficiently stiff. The C-Fix anchor plate design is based on a proof of stresses and does not allow a statement about the
stiffness of the plate. The proof of the necessary stiffness is not carried out by C-Fix.

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 7
C-FIX 1.99.0.0
Database version
2021.4.3.17.13
Date
17/06/2021

Installation data
Anchor
Anchor system fischer Bolt anchor FAZ II
Anchor Bolt anchor FAZ II 8/5 K R, Art.-No. 538990
stainless steel

Accessories Blow-out pump ABG big Art.-No. 89300


Quattric II 8/100/165 XP5 Art.-No. 549989

Installation details
Thread diameter M8
Drill hole diameter d0 = 8 mm
Drill hole depth h2 = 55 mm
Calculated anchorage hef = 35 mm
depth
Installation depth hnom = 45 mm
Drilling method Hammer drilling
Drill hole cleaning Only blow out by hand
Installation type Push-through installation
Annular gap Annular gap not filled
Installation torque Tinst = 20.0 Nm
Socket size 13 mm
Base plate thickness t = 5 mm
Total fixing thickness tfix = 5 mm
Tfix,max tfix, max = 5 mm

Base plate details


Base plate material Not available
Base plate thickness t = 5 mm
Clearance hole in base df=9 mm
plate

Attachment
Profile type None

Anchor coordinates

x y
Anchor no. mm mm
1 0 250
2 0 -250

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 8