C-FIX 1.73.0.

0
Database version
2018.12.13.9.39
Date
19/08/2020

fischer FZE

Jebel Ali Free Zone Warehouse No XB


P.O. Box 261738 Dubai

Enquiry@fischer.ae
www.fischer.ae

Design Specifications
Anchor
Anchor system fischer Injection system FIS V
Injection resin FIS V 360 S
Fixing element Threaded rod FIS A M 10 x 150 8.8, zinc plated steel,
property class 8.8
Anchorage depth 70 mm

Geometry / Loads / Scale units


mm, kN, kNm

Value of design actions (including

partial safety factor for the load) Static

Not drawn to scale

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 1
C-FIX 1.73.0.0
Database version
2018.12.13.9.39
Date
19/08/2020

Input data

Design method Design Method ETAG029


Base material Solid light-weight concrete block Vbl, 440x440x4200, EN
771-3,
Compressive strength ≥ 10.0 N/mm², ≥ 2 kg/dm³,
Mortar strength M10 - M20, Joints visible and filled
Drilling method hammer drilling
Installation type Pre-positioned installation
Type of loading Static or quasi-static
Installation condition dry/dry
Base plate location Base plate flush installed on base material
Base plate geometry 100 mm x 600 mm x 8 mm
Profile type None

Design actions *⁾
# NSd VSd,x VSd,y MSd,x MSd,y MT,Sd Type of loading
kN kN kN kNm kNm kNm
1 -2.30 0.27 0.10 0.00 0.00 0.00 Static or quasi-static

*⁾ The required partial safety factors for actions are included

Resulting anchor forces


Tensile action Shear Action Shear Action x Shear Action y
Anchor no. kN kN kN kN
1 0.00 0.14 0.14 0.05
2 0.00 0.14 0.14 0.05

Resulting tensile actions : 0.00 kN , X/Y position ( 0 / 0 )


Resulting compression actions : 2.30 kN , X/Y position ( 0 / 0 )

Resistance to shear loads


Proof Action Capacity Utilisation βV
kN kN %
Steel failure without lever arm 1 0.14 1.60 9.0
Local brick failure single anchor 1 0.14 1.60 9.0
Local brick failure anchor group 0.29 3.20 9.0
0.00 1.60
Brick edge failure single anchor 2 9.0
0.05 1.60
0.27 3.20
Brick edge failure anchor group 3 9.0
0.10 3.20
Pushing out of one brick 0.27 1.60 16.9
1
Most unfavourable anchor
2
Most unfavourable anchor and edge
3
Most unfavourable edge

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 2
C-FIX 1.73.0.0
Database version
2018.12.13.9.39
Date
19/08/2020

Steel failure without lever arm

(VRd,s)

VRk,s γM,s VRd,s VSd βV,s


kN kN kN %
4.00 2.50 1.60 0.14 9.0

Local brick failure single anchor

(VRd,b)

αj,V VRk,b γM,m VRd,b VSd βV,b


kN kN kN %
1.00 4.00 2.50 1.60 0.14 9.0

Local brick failure anchor group


g
(V Rd)

g g g
αj,V V Rk γM,m V Rd VSd β V,b
kN kN kN %
1.00 8.00 2.50 3.20 0.29 9.0

Brick edge failure single anchor

(VRd,c,.)

. αj,V VRk,c,. γM,m VRd,c,. VSd,. βV,c,. βV,c


kN kN kN % %
1.00 4.00 2.50 1.60 0.00 0.0
9.0
1.00 4.00 2.50 1.60 0.05 3.1

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 3
C-FIX 1.73.0.0
Database version
2018.12.13.9.39
Date
19/08/2020

Brick edge failure anchor group


g
(V Rd,c,.)

g g g g g
. αj,V V Rk,c,. γM,m V Rd,c,. V Sd,. β V,c,. β V,c
kN kN kN % %
1.00 8.00 2.50 3.20 0.27 8.4
9.0
1.00 8.00 2.50 3.20 0.10 3.1

Pushing out of one brick

(VRd,pb)

VRk,pb γM,m VRd,pb VSd βV,pb


kN kN kN %
4.00 2.50 1.60 0.27 16.9

Resistance to combined tensile and shear loads

Proof successful Eq. C.5.8b

Information concerning the anchor plate


Base plate details
Plate thickness specified by user without proof t = 8 mm

Profile type None

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 4
C-FIX 1.73.0.0
Database version
2018.12.13.9.39
Date
19/08/2020

Technical remarks
The transmission of the anchor loads to the support shall be shown for the ultimate limit state and the serviceability limit
state. For this purpose, the normal verifications shall be carried out under consideration of the actions introduced by the
anchors. For these verifications the provisions given in the current design method shall be taken into account.
As a pre-condition the anchor plate is assumed to be flat when subjected to the actions. Therefore, the plate must be
sufficiently stiff. The C-Fix anchor plate design is based on a proof of stresses and does not allow a statement about
the stiffness of the plate. The proof of the necessary stiffness is not carried out by C-Fix.

During the design process, the following hints and warnings were issued:

• In the current view a bottom edge is selected. Assuming this as joint from the masonry to the concrete slab we don't
do any calculation for edge failure in this case.

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 5
C-FIX 1.73.0.0
Database version
2018.12.13.9.39
Date
19/08/2020

Installation data
Anchor
Anchor system fischer Injection system FIS V
Injection resin FIS V 360 S (other cartridge sizes Art.-No. 68435
available)
Fixing element Threaded rod FIS A M 10 x 150 8.8, Art.-No. 517935
zinc plated steel, property class 8.8

Accessories FIS MR Plus Art.-No. 545853


Dispenser FIS DM S Art.-No. 511118
Blow-out pump ABG big Art.-No. 89300
Cleaning brush BS 12 Art.-No. 78179
Hammer drill bit SDS Plus IV Art.-No. 504144
12/100/160
Alternative cartdriges FIS V 410 C Art.-No. 77529
FIS V 950 S Art.-No. 17101
The shown cartdriges are
alternative to the highlighted
one above with the same approval
number.

Installation details
Thread diameter M 10
Drill hole diameter d0 = 12 mm
Drill hole depth h1 = 70 mm
Anchorage depth hef = 70 mm
Drilling method hammer drilling
Installation type Pre-positioned installation
Maximum torque Tinst,max = 10.0 Nm
Socket size 17 mm
Base plate thickness t = 8 mm
Total fixing thickness tfix = 8 mm
Tfix,max

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 6
C-FIX 1.73.0.0
Database version
2018.12.13.9.39
Date
19/08/2020

Base plate details


Base plate material Not available
Base plate thickness t = 8 mm
Clearance hole in base df=12 mm
plate

Attachment
Profile type None

Anchor coordinates

x y
Anchor no. mm mm
1 0 250
2 0 -250

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in