Design Specifications
Anchor
Anchor system fischer Bolt anchor FAZ II
Anchor Bolt anchor FAZ II 12/10 R, stainless steel, property class R
Calculated anchorage 50 mm
depth
Design Data Specification by manufacturer

Geometry / Loads / Scale units


mm, kN, kNm

Value of design actions (including

partial safety factor for the load) Static

Not drawn to scale

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 1
C-FIX 1.89.0.0
Database version
2020.6.29.13.59
Date
15/08/2023

B-TOP BRACKET

Input data

Design method TR055/Design method ENSO Mechanical


Base material Normal weight concrete, C30/37, EN 206
Concrete condition Cracked, dry hole
Reinforcement No or standard reinforcement. No edge reinforcement.
Without reinforcement against splitting
Drilling method hammer drilling
Installation type Push-through installation
Annular gap Annular gap filled
Type of loading Static or quasi-static
Base plate location Base plate flush installed on base material
Base plate geometry 140 mm x 220 mm x 10 mm
Profile type Customized profile

Design actions *⁾
# NSd VSd,x VSd,y MSd,x MSd,y MT,Sd Type of loading
kN kN kN kNm kNm kNm
1 0.00 7.91 0.00 0.00 0.62 0.00 Static or quasi-static

*⁾ The required partial safety factors for actions are included

Resulting anchor forces


Tensile action Shear Action Shear Action x Shear Action y
Anchor no. kN kN kN kN
1 4.95 3.98 3.98 0.00
2 4.93 3.93 3.93 0.00

max. concrete compressive strain : 0.13 ‰


max. concrete compressive stress : 4.2 N/mm²
Resulting tensile actions : 9.88 kN , X/Y position ( 0 / 0 )
Resulting compression actions : 9.88 kN , X/Y position ( 63 / 0 )

Resistance to tension loads

Action Capacity Utilisation βN


Proof kN kN %
Steel failure * 4.95 29.53 16.8
Pullout failure * 4.95 16.27 30.4
Concrete cone failure 9.88 20.27 48.7

* Most unfavourable anchor

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 2
C-FIX 1.89.0.0
Database version
2020.6.29.13.59
Date
15/08/2023

B-TOP BRACKET

Steel failure

( NRd,s )

NRk,s γMs NRd,s NSd βN,s


kN kN kN %
44.30 1.50 29.53 4.95 16.8

βN,s
Anchor no. % Group N° Decisive Beta
1 16.8 1 βN,s;1
2 16.7 2 βN,s;2

Pullout failure

( NRd,p )

NRk,p Ψc γMp NRd,p NSd βN,p


kN kN kN %
24.40 1.220 1.50 16.27 4.95 30.4

The given Psi,c-factor may has been determined by interpolation.

βN,p
Anchor no. % Group N° Decisive Beta
1 30.4 1 βN,p;1
2 30.3 2 βN,p;2

Concrete cone failure

( NRd,c )

Eq. (5.2)

Eq. (5.2a)

Eq. (5.2c)

Eq. (5.2d)

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 3
C-FIX 1.89.0.0
Database version
2020.6.29.13.59
Date
15/08/2023

B-TOP BRACKET

Eq. (5.2e)

NRk,c γMc NRd,c NSd βN,c


kN kN kN %
30.41 1.50 20.27 9.88 48.7

βN,c
Anchor no. % Group N° Decisive Beta
1, 2 48.7 1 βN,c;1

Resistance to shear loads

Proof Action Capacity Utilisation βV


kN kN %
Steel failure without lever arm * 3.98 30.64 13.0
Concrete pry-out failure 7.91 62.52 12.7

* Most unfavourable anchor

Steel failure without lever arm

( VRd,s )

VRk,s γMs VRd,s VSd βVs


kN kN kN %
38.30 1.25 30.64 3.98 13.0

βVs
Anchor no. % Group N° Decisive Beta
1 13.0 1 βVs;1
2 12.8 2 βVs;2

Concrete pry-out failure

( VRd,cp )

Eq. (5.6)

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 4
C-FIX 1.89.0.0
Database version
2020.6.29.13.59
Date
15/08/2023

B-TOP BRACKET

Eq. (5.2)

Eq. (5.2a)

Eq. (5.2c)

Eq. (5.2d)

Eq. (5.2e)

VRk,cp γMc VRd,cp VSd βV,cp


kN kN kN %
93.78 1.50 62.52 7.91 12.7

βV,cp
Anchor no. % Group N° Decisive Beta
1, 2 12.7 1 βV,cp;1

Utilization of tension and shear loads

Tension loads Utilisation βN Shear Loads Utilisation βV


% %
Steel failure * 16.8 Steel failure without lever arm * 13.0
Pullout failure * 30.4 Concrete pry-out failure 12.7
Concrete cone failure 48.7
* Most unfavourable anchor

Resistance to combined tensile and shear loads


Utilisation steel
Eq. (5.8a)

Eq. (5.8b)

Eq. (5.9)

Utilisation concrete Proof successful


Eq. (5.8a)

Eq. (5.8b)

Eq. (5.9)

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 5
C-FIX 1.89.0.0
Database version
2020.6.29.13.59
Date
15/08/2023

B-TOP BRACKET

Base plate thickness


Stress distribution pattern within the Base plate details
anchor plate
Anchor plate thickness t = 10 mm
Base plate material S 275
E-modulus E = 210,000 N/mm²
Yield strength Rp,0,2 = 275 N/mm²
Safety factor γM = 1.1
Poisson's ratio ν = 0.3
Utilisation η = 40 %

Profile type Customized profile

Technical remarks
All data and information in the software is based on fischer products and common engineering knowledge. Please
check all the proof results against local valid standards and approvals.
As fischer is not the design office, the attached is no guarantee for incorrect input or assumptions. Any
recommendations have to be approved by the building-authority or project engineer. Results are valid only for
anchor system calculated in the attached. If any part of the system is changed, it will invalidate this report and new
calculations would be required.
The transmission of the anchor loads to the supports of the concrete member shall be shown for the ultimate limit state and
the serviceability limit state; for this purpose, the normal verifications shall be carried out under due consideration of the
actions introduced by the anchors. For these verifications the additional provisions given in the current design method shall
be taken into account.
As a pre-condition the anchor plate is assumed to be flat when subjected to the actions. Therefore, the plate must be
sufficiently stiff. The C-Fix anchor plate design is based on a proof of stresses and does not allow a statement about
the stiffness of the plate. The proof of the necessary stiffness is not carried out by C-Fix.

During the design process, the following hints and warnings were issued:

• Filling Washer Required

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 6
C-FIX 1.89.0.0
Database version
2020.6.29.13.59
Date
15/08/2023

B-TOP BRACKET

Installation data
Anchor
Anchor system fischer Bolt anchor FAZ II
Anchor Bolt anchor FAZ II 12/10 R, Art.-No. 501413
stainless steel, property class R

Accessories FFD 30x14x6 A4 Art.-No. 541987


Blow-out pump ABG big Art.-No. 89300
SDS Plus II 12/100/160 Art.-No. 531803
or alternatively
FHD 12/200/330 Art.-No. 546597
Hammer drilling with or without
suction
The calculation consists a special
washer. With the filling washer it is
assured that the gap between plate
and anchor is eliminated and the
shear load is transfered to every
anchor in equal parts.

Installation details
Thread diameter M 12
Drill hole diameter d0 = 12 mm
Drill hole depth h2 = 85 mm
Calculated anchorage hef = 50 mm
depth
Installation depth hnom = 64 mm
Drilling method hammer drilling
Drill hole cleaning only blow out by hand
No borehole cleaning required in
case of using a hollow drill bit, e.g.
fischer FHD.
Installation type Push-through installation
Annular gap Annular gap filled
Installation torque Tinst = 60.0 Nm
Socket size 19 mm
Base plate thickness t = 10 mm
Total fixing thickness tfix = 16 mm
Tfix,max tfix, max = 30 mm

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 7
C-FIX 1.89.0.0
Database version
2020.6.29.13.59
Date
15/08/2023

B-TOP BRACKET

Base plate details


Base plate material S 275
Base plate thickness t = 10 mm
Clearance hole in base df=14 mm
plate

Attachment
Profile type Customized profile
Distance between profiles 28 mm

Profile dimensions mm
Height 8

Anchor coordinates

x y
Anchor no. mm mm
1 0 72
2 0 -73

The input values and the design results should be checked against local valid standards and approvals. Please respect the disclaimer of warranty in
the license agreement of the Software.

Page 8