Professional Documents
Culture Documents
Date : 9/22/2023
Page : 1/6
CALCULATION SHEET FOR RED HEAD ANCHORS
Company : Florida Engineering Phone number :
Carried out by : DS Mail address : divyang@fleng.com
Company : Florida Engineering Project name : Clemson Womens Sports
Contact name : Divyang Soni Location : South Carolina
Phone number : Fastening point :
Mail address :
Comment :
Recommended anchors
Trubolt Wedge Anchor Carbon Steel (Min. embedment) 3/8 Min. Effective embedment: 1.75 in
Base material
Concrete Strength 3000 psi
Concrete condition: Uncracked
Thickness of concrete : 5 in
Tension load conditions: Condition A Tension
Shear load conditions: Condition A Shear
Edge reinforcement : None or < no. 4 bar
Longitudinal reinforcement should be provided along the edge of the member
Anchor plate
Thickness of part to be fixed : 0.5 in
Recommended plate thickness : 0.4 in with maximum displacement 0 in + fleche 0.098 + maximum strength 18745.3 psi
Clearance diameter : 0.4 in
Profile : HSS 2X2X1/4
Profile position : Ex = 0 in ; Ey = 0 in
Stand-off : None
Conditions
Installation conditions : Dry concrete
Hole drilling method: Hammer drilling
Short term temperature : 130 °F
Long term temperature : 110 °F
Geometry :
Calculation Hypothesis :
The anchoring plate is assumed to be sufficient to resist deformation imposed by the load actions.
REDHEAD can only be held responsible if the calculation examples exactly reflect the application and if the installation is carried
out according to the instruction given in the REDHEAD specifications. The calculation is correct for REDHEAD anchors only. The
contractor or specifier should make sure that the base material is able to support the loads especially in the case of a group of
anchors. REDHEAD cannot be held responsible if this software package is modified without its written approval.
Ref : 9/22/2023 - 10:40:05 AM / Version 2103
Date : 9/22/2023
Page : 3/6
Loads on anchors
1308 654 0 0
154 38
Utilization
Tension load
Pull out strength 654 1565 41.8
Concrete breakout strength 1308 4061 32.2
Shear load
Concrete Breakout Strength 154 2518 6.1
Pryout strength 154 6675 2.3
Steel strength 38 1934 1.99
CALCULATION DETAILS
Tension load - Pull out Strength
The base plate thickness has been checked and this thickness is enough to be considered as rigid
0.4 in with maximum displacement 0 in + fleche 0.098 + maximum
Max. base plate thickness
strength 18745.3 psi
Maximum displacement:
Relative displacement:
Max Von Mises stress:
INSTALLATION DATA
Trubolt Wedge Anchor Carbon Steel (Min. embedment) 3/8 Min. Effective embedment: 1.75 in
INSTALLATION Method