Professional Documents
Culture Documents
3
Company: Page: 1
Specifier: Project: Oami Residence
Address: Sub-Project I Pos. No.: steel-beam
Phone I Fax: | Date: 1/26/2021
E-Mail:
Specifier's comments:
1 Input data
Anchor type and diameter: HIT-HY 200 + HAS 1/2
Effective embedment depth: hef,act = 4.000 in. (hef,limit = - in.)
Material: 5.8
Evaluation Service Report: ESR-3187
Issued I Valid: 4/1/2013 | 3/1/2014
Proof: design method ACI 318 / AC308
Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.500 in.
Anchor plate: lx x ly x t = 10.000 in. x 8.000 in. x 0.500 in.; (Recommended plate thickness: not calculated)
Profile: W shape (AISC); (L x W x T x FT) = 6.380 in. x 6.080 in. x 0.320 in. x 0.455 in.
Base material: cracked concrete, 3000, fc' = 3000 psi; h = 8.000 in., Temp. short/long: 32/32 °F
Installation: hammer drilled hole, installation condition: dry
Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present
edge reinforcement: > No. 4 bar
Seismic loads (cat. C, D, E, or F) no
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.us Profis Anchor 2.4.3
Company: Page: 2
Specifier: Project: Oami Residence
Address: Sub-Project I Pos. No.: steel-beam
Phone I Fax: | Date: 1/26/2021
E-Mail:
3 Tension load
Load Nua [lb] Capacity fNn [lb] Utilization bN = Nua/fNn Status
Steel Strength* N/A N/A N/A N/A
Bond Strength** N/A N/A N/A N/A
Concrete Breakout Strength** N/A N/A N/A N/A
* anchor having the highest loading **anchor group (anchors in tension)
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.us Profis Anchor 2.4.3
Company: Page: 3
Specifier: Project: Oami Residence
Address: Sub-Project I Pos. No.: steel-beam
Phone I Fax: | Date: 1/26/2021
E-Mail:
4 Shear load
Load Vua [lb] Capacity fVn [lb] Utilization bV = Vua/fVn Status
Steel Strength* 3250 3705 88 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength (Bond Strength controls)** 13000 13989 93 OK
Concrete edge failure in direction ** N/A N/A N/A N/A
* anchor having the highest loading **anchor group (relevant anchors)
Variables
n Ase,V [in.2] futa [psi]
1 0.14 72500
Calculations
Vsa [lb]
6175
Results
Vsa [lb] fsteel f Vsa [lb] Vua [lb]
6175 0.600 3705 3250
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.us Profis Anchor 2.4.3
Company: Page: 4
Specifier: Project: Oami Residence
Address: Sub-Project I Pos. No.: steel-beam
Phone I Fax: | Date: 1/26/2021
E-Mail:
√
scr,Na = 20 d tk,uncr ≤ 3 hef
1450
ICC-ES AC308 Eq. (D-16d)
scr,Na
ccr,Na = ICC-ES AC308 Eq. (D-16e)
2
yed,Na = 0.7 + 0.3 c ( )
ca,min
cr,Na
≤ 1.0 ICC-ES AC308 Eq. (D-16m)
[( ) ]
0.5
savg
yg,Na = yg,Na0 + · (1 - yg,Na0) ≥ 1.0 ICC-ES AC308 Eq. (D-16g)
scr,Na
= √n - [(√n - 1) · ( ) ]≥ 1.0
1.5
t k,c
ICC-ES AC308 Eq. (D-16h)
yg,Na0
t k,max,c
kc
tk,max,c = √hef · f'c ICC-ES AC308 Eq. (D-16i)
p·d
( )
1
yec,Na = 2' ≤ 1.0 ICC-ES AC308 Eq. (D-16j)
1 + e,N
scr,Na
yp,Na (
c c
= MAX a,min, cr,Na ≤ 1.0
cac cac ) ICC-ES AC308 Eq. (D-16p)
Na0 = tk,c · kbond · p · d · hef ICC-ES AC308 Eq. (D-16f)
Variables
kcp tk,c,uncr [psi] tk,c [psi] danchor [in.] hef [in.] savg [in.] n
2.000 1880 1051 0.500 4.000 4.500 4
kc f'c [psi] ec1,N [in.] ec2,N [in.] ca,min [in.] cac [in.] kbond
17 3000 0.000 0.000 3.250 7.874 1.00
Calculations
scr,Na [in.] ccr,Na [in.] ANa [in.2] ANa0 [in.2] yed,N tk,max [psi]
11.385 5.693 212.07 129.63 0.871 1186
Results
Vcpg [lb] fconcrete f Vcpg [lb] Vua [lb]
19985 0.700 13989 13000
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.us Profis Anchor 2.4.3
Company: Page: 5
Specifier: Project: Oami Residence
Address: Sub-Project I Pos. No.: steel-beam
Phone I Fax: | Date: 1/26/2021
E-Mail:
5 Warnings
• To avoid failure of the anchor plate the required thickness can be calculated in PROFIS Anchor. Load re-distributions on the anchors due to
elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be sufficiently stiff, in order not to be deformed when
subjected to the loading!
• Condition A applies when supplementary reinforcement is used. The Φ factor is increased for non-steel Design Strengths except Pullout Strength
and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength. Refer to
your local standard.
• Design Strengths of adhesive anchor systems are influenced by the cleaning method. Refer to the INSTRUCTIONS FOR USE given in the
Evaluation Service Report for cleaning and installation instructions
• The present version of the software does not account for adhesive anchor special design provisions corresponding to overhead applications.
Refer to the ICC-ES Evaluation Service Report (e.g. section 4.1.1 of the ICC-ESR 2322) for details.
• Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standard!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.us Profis Anchor 2.4.3
Company: Page: 6
Specifier: Project: Oami Residence
Address: Sub-Project I Pos. No.: steel-beam
Phone I Fax: | Date: 1/26/2021
E-Mail:
6 Installation data
Anchor plate, steel: - Anchor type and diameter: HIT-HY 200 + HAS, 1/2
Profile: W shape (AISC); 6.380 x 6.080 x 0.320 x 0.455 in. Installation torque: 360.001 in.lb
Hole diameter in the fixture: df = 0.563 in. Hole diameter in the base material: 0.563 in.
Plate thickness (input): 0.500 in. Hole depth in the base material: 4.000 in.
Recommended plate thickness: not calculated Minimum thickness of the base material: 5.250 in.
Cleaning: Premium cleaning of the drilled hole is required
y
5.000 5.000
1.500
3 4
4.000
5.000
x
1 2 4.000
1.500
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.us Profis Anchor 2.4.3
Company: Page: 7
Specifier: Project: Oami Residence
Address: Sub-Project I Pos. No.: steel-beam
Phone I Fax: | Date: 1/26/2021
E-Mail:
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan