You are on page 1of 7

www.hilti.com.mx Profis Anchor 2.5.

0
Company: Page: 1
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 09/02/2015
E-Mail:

Specifier's comments:

1 Input data
Anchor type and diameter: HIT-HY 150 MAX-SD + Rebar A 615 Gr.60 #4
Effective embedment depth: hef,opti = 70 mm (hef,limit = 168 mm)
Material: ASTM A 615 GR.60
Evaluation Service Report: ESR-3013
Issued I Valid: 01/04/2013 | 01/04/2014
Proof: Design method ACI 318 / AC308
Stand-off installation: eb = 0 mm (no stand-off); t = 12 mm
Anchor plate: lx x ly x t = 300 mm x 300 mm x 12 mm; (Recommended plate thickness: not calculated)
Profile: no profile
Base material: uncracked concrete, 4000, fc' = 4000 psi; h = 200 mm, Temp. short/long: 40/20 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present
edge reinforcement: > No. 4 bar
Seismic loads (cat. C, D, E, or F) no

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.mx Profis Anchor 2.5.0
Company: Page: 2
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 09/02/2015
E-Mail:

2 Load case/Resulting anchor forces


Load case: Design loads
3 y 4
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 0.000 12.000 12.000 0.000
2 0.000 12.000 12.000 0.000 x
3 0.000 12.000 12.000 0.000
4 0.000 12.000 12.000 0.000
max. concrete compressive strain: - [‰]
max. concrete compressive stress: - [N/mm2]
resulting tension force in (x/y)=(0/0): 0.000 [kN]
resulting compression force in (x/y)=(0/0): 0.000 [kN] 1 2

3 Tension load
Load Nua [kN] Capacity fNn [kN] Utilization bN = Nua/fNn Status
Steel Strength* N/A N/A N/A N/A
Bond Strength** N/A N/A N/A N/A
Concrete Breakout Strength** N/A N/A N/A N/A
* anchor having the highest loading **anchor group (anchors in tension)

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.mx Profis Anchor 2.5.0
Company: Page: 3
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 09/02/2015
E-Mail:

4 Shear load
Load Vua [kN] Capacity fVn [kN] Utilization bV = Vua/fVn Status
Steel Strength* 12.000 28.824 42 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength (Bond Strength controls)** 48.000 133.403 36 OK
Concrete edge failure in direction y+** 48.000 75.013 64 OK
* anchor having the highest loading **anchor group (relevant anchors)

4.1 Steel Strength


Vsa = (n 0.6 Ase,V futa) refer to ICC-ES ESR-3013
f Vsteel ≥ Vua ACI 318-08 Eq. (D-2)

Variables
n Ase,V [mm2] futa [N/mm2] (n 0.6 Ase,V futa) [kN]
1 129 620.53 48.041
Calculations
Vsa [kN]
48.041
Results
Vsa [kN] fsteel f Vsa [kN] Vua [kN]
48.041 0.600 28.824 12.000

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.mx Profis Anchor 2.5.0
Company: Page: 4
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 09/02/2015
E-Mail:

4.2 Pryout Strength (Bond Strength controls)

Vcpg =kcp [(AA ) y


Na
Na0
ed,Na yg,Na yec,Na yp,Na Na0 ] ACI 318-08 Eq. (D-31)
f Vcpg ≥ Vua ACI 318-08 Eq. (D-1)
ANa see ICC-ES AC308, Part D.5.3.7
ANa0 = s2cr,Na ICC-ES AC308 Eq. (D-16c)


scr,Na = 20 d tk,uncr ≤ 3 hef
1450
ICC-ES AC308 Eq. (D-16d)
s
ccr,Na = cr,Na ICC-ES AC308 Eq. (D-16e)
2
yed,Na = 0.7 + 0.3 c ( )
ca,min
cr,Na
≤ 1.0 ICC-ES AC308 Eq. (D-16m)

[( ) ]
0.5
savg
yg,Na = yg,Na0 + · (1 - yg,Na0) ≥ 1.0 ICC-ES AC308 Eq. (D-16g)
scr,Na

= √n - [(√n - 1) · ( t ) ]≥ 1.0
1.5
k,c
yg,Na0 ICC-ES AC308 Eq. (D-16h)
t k,max,c
kc
tk,max,c = √ h · f' ICC-ES AC308 Eq. (D-16i)
p · d ef c

( )
1
yec,Na = 2' ≤ 1.0 ICC-ES AC308 Eq. (D-16j)
1 + e,N
scr,Na

yp,Na (c c
= MAX a,min, cr,Na ≤ 1.0
cac cac ) ICC-ES AC308 Eq. (D-16p)
Na0 = tk,c · kbond · p · d · hef ICC-ES AC308 Eq. (D-16f)

Variables
2 2
kcp tk,c,uncr [N/mm ] tk,c [N/mm ] danchor [mm] hef [mm] savg [mm] n
2.000 8.89 8.89 13 70 200 4

kc f'c [psi] ec1,N [mm] ec2,N [mm] ca,min [mm] cac [mm] kbond
24 4000 0 0 150 102 1.00

Calculations
scr,Na [mm] ccr,Na [mm] ANa [mm2] ANa0 [mm2] yed,N
2
tk,max [N/mm ]
210 105 167731 43911 1.000 11.05

yg,Na0 yg,Na yec1,N yec2,N yp,Na Na0 [kN]


1.278 1.006 1.000 1.000 1.000 24.787

Results
Vcpg [kN] fconcrete f Vcpg [kN] Vua [kN]
190.576 0.700 133.403 48.000

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.mx Profis Anchor 2.5.0
Company: Page: 5
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 09/02/2015
E-Mail:

4.3 Concrete edge failure in direction y+

Vcbg = (AA ) y
Vc
Vc0
ec,V yed,V yc,V yh,V yparallel,V Vb ACI 318-08 Eq. (D-22)
f Vcbg ≥ Vua ACI 318-08 Eq. (D-2)
AVc see ACI 318-08, Part D.6.2.1, Fig. RD.6.2.1(b)
AVc0 = 4.5 c2a1 ACI 318-08 Eq. (D-23)

( )
1
yec,V = 2e'v ≤ 1.0 ACI 318-08 Eq. (D-26)
1+
3ca1

yed,V = 0.7 + 0.3 1.5c(


ca2
a1
)
≤ 1.0 ACI 318-08 Eq. (D-28)

yh,V = √
1.5ca1
ha
≥ 1.0 ACI 318-08 Eq. (D-29)

(( ) )
0.2
l 1.5
Vb = 7 e √da l √f'c ca1 ACI 318-08 Eq. (D-24)
da

Variables
ca1 [mm] ca2 [mm] ecV [mm] yc,V ha [mm]
150 - 0 1.400 200

le [mm] l da [mm] f'c [psi] yparallel,V


70 1.000 13 4000 2.000

Calculations
AVc [mm2] AVc0 [mm2] yec,V yed,V yh,V Vb [kN]
130000 101250 1.000 1.000 1.061 28.103
Results
Vcbg [kN] fconcrete f Vcbg [kN] Vua [kN]
107.162 0.700 75.013 48.000

5 Warnings
• Load re-distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be
sufficiently stiff, in order not to be deformed when subjected to the loading! Input data and results must be checked for agreement with the
existing conditions and for plausibility!
• Condition A applies when supplementary reinforcement is used. The Φ factor is increased for non-steel Design Strengths except Pullout Strength
and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength. Refer to
your local standard.
• Design Strengths of adhesive anchor systems are influenced by the cleaning method. Refer to the INSTRUCTIONS FOR USE given in the
Evaluation Service Report for cleaning and installation instructions
• The ACI 318-08 version of the software does not account for adhesive anchor special design provisions corresponding to overhead applications.
• Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI 318 or the relevant standard!

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.mx Profis Anchor 2.5.0
Company: Page: 6
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 09/02/2015
E-Mail:

6 Installation data
Anchor plate, steel: - Anchor type and diameter: HIT-HY 150 MAX-SD + Rebar A 615 Gr.60 #4
Profile: Flat bar; 0 x 0 x 0 mm Installation torque: 0.000 kNm
Hole diameter in the fixture: df = 13 mm Hole diameter in the base material: 16 mm
Plate thickness (input): 12 mm Hole depth in the base material: 70 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 102 mm
Cleaning: Premium cleaning of the drilled hole is required

150 150

50
3 4

150
200
x

150

1 2
50

50 200 50

Coordinates Anchor mm
Anchor x y c-x c+x c-y c+y
1 -100 -100 - - 150 350
2 100 -100 - - 150 350
3 -100 100 - - 350 150
4 100 100 - - 350 150

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.mx Profis Anchor 2.5.0
Company: Page: 7
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 09/02/2015
E-Mail:

7 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and
security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly
complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using
the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in.
Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you.
Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to
compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms
and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific
application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the
regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use
the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case
by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or
programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan