You are on page 1of 9

Hilti PROFIS Engineering 3.0.

80

www.hilti.be
Company: MBG Nobel I UZ Gent - kroon Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: BRACING - TOP PLATE Date: 28/09/2022
Fastening Point:

Specifier's comments:

1 Input data
Anchor type and size: HIT-HY 200-A + HAS-U 8.8 M16
Return period (service life in years): 50
Item number: 2237090 HAS-U 8.8 M16x260 (insert) / 2022696
HIT-HY 200-A (mortar)
Hilti Filling Set or any suitable annular gap filling solution
Effective embedment depth: hef,act = 200.0 mm (hef,limit = - mm)
Material: 8.8
Approval No.: ETA 11/0493
Issued I Valid: 10/12/2021 | -
Proof: SOFA design method + fib (07/2011) - after ETAG BOND testing
Stand-off installation: eb = 0.0 mm (no stand-off); t = 25.0 mm

Baseplate :
R lx x ly x t = 200.0 mm x 500.0 mm x 25.0 mm; (Recommended plate thickness: not calculated)

Profile: no profile
Base material: 2
cracked concrete, C40/50, fc,cyl = 40.00 N/mm ; h = 450.0 mm, Temp. short/long: 40/24 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: Reinforcement spacing < 150 mm (any Ø) or < 100 mm (Ø <= 10 mm)
with longitudinal edge reinforcement d >= 12.0 [mm] + close mesh (stirrups, hangers) s <= 100.0
[mm]

Application also possible with HVU2 + HAS-U 8.8 M16_hef1 under the selected boundary conditions.
More information in section Alternative fastening data of this report.

R
- The anchor calculation is based on a rigid baseplate assumption.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

1
Hilti PROFIS Engineering 3.0.80

www.hilti.be
Company: MBG Nobel I UZ Gent - kroon Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: BRACING - TOP PLATE Date: 28/09/2022
Fastening Point:

1.1 Load combination


Case Description Forces [kN] / Moments [kNm] Seismic Fire Max. Util. Anchor [%]
1 UGT2 N = 15.000; Vx = 30.000; Vy = 0.000; no no 45
Mx = 0.000; My = 0.000; Mz = 0.000;
Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000;

2 UGT3 N = 0.000; Vx = 0.000; Vy = 0.000; no no 42


Mx = -7.000; My = 0.000; Mz = 5.000;
Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000;

2 Load case/Resulting anchor forces y


3
Controlling load case: 1 UGT2

Anchor reactions [kN]


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y 2 x
1 5.000 10.000 10.000 0.000 Tension Compression
2 5.000 10.000 10.000 0.000
3 5.000 10.000 10.000 0.000

max. concrete compressive strain: 0.00 [‰]


max. concrete compressive stress: 0.00 [N/mm ]
2 1
resulting tension force in (x/y)=(-50.0/0.0): 15.000 [kN]
resulting compression force in (x/y)=(100.0/0.0): 0.000 [kN]

Anchor forces are calculated based on the assumption of a rigid baseplate.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

2
Hilti PROFIS Engineering 3.0.80

www.hilti.be
Company: MBG Nobel I UZ Gent - kroon Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: BRACING - TOP PLATE Date: 28/09/2022
Fastening Point:

3 Tension load SOFA (fib (07/2011), section 16.2.1)


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel failure* 5.000 83.733 6 OK
Combined pullout-concrete cone failure** 15.000 87.597 18 OK
Concrete Breakout failure** 15.000 97.567 16 OK
Splitting failure** 15.000 220.025 7 OK

* highest loaded anchor **anchor group (anchors in tension)

3.1 Steel failure

NRk,s [kN] gM,s NRd,s [kN] NSd [kN]


125.600 1.500 83.733 5.000

3.2 Combined pullout-concrete cone failure


0 2
Ap,N [mm ]
2
Ap,N [mm ] y A,Np t Rk,ucr,25 [N/mm ]
2
scr,Np [mm] ccr,Np [mm] cmin [mm]
356,390 245,760 0.000 18.00 495.7 247.9 150.0
0
yc t Rk,cr [N/mm ]
2
max t Rk,cr [N/mm ]
2
y g,Np y g,Np
1.072 9.11 13.70 1.335 1.122

ec1,N [mm] y ec1,Np ec2,N [mm] y ec2,Np y s,Np y re,Np


0.0 1.000 0.0 1.000 0.882 1.000
0
NRk,p [kN] NRk,p [kN] gM,p NRd,p [kN] NSd [kN]
91.584 131.396 1.500 87.597 15.000

Group anchor ID
1-3

3.3 Concrete Breakout failure


0 2
Ac,N [mm ]
2
Ac,N [mm ] y A,N ccr,N [mm] scr,N [mm]
450,000 360,000 1.250 300.0 600.0

ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N


0.0 1.000 0.0 1.000 0.850 1.000
0
k1 NRk,c [kN] gM,c NRd,c [kN] NSd [kN]
7.700 137.742 1.500 97.567 15.000

Group anchor ID
1-3

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

3
Hilti PROFIS Engineering 3.0.80

www.hilti.be
Company: MBG Nobel I UZ Gent - kroon Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: BRACING - TOP PLATE Date: 28/09/2022
Fastening Point:

3.4 Splitting failure


0 2
Ac,N [mm ]
2
Ac,N [mm ] y A,N ccr,sp [mm] scr,sp [mm] y h,sp
280,000 160,000 1.750 200.0 400.0 1.480

ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N k1


0.0 1.000 0.0 1.000 0.925 1.000 7.700
0
NRk,c [kN] gM,sp NRd,sp [kN] NSd [kN]
137.742 1.500 220.025 15.000

Group anchor ID
1-3

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

4
Hilti PROFIS Engineering 3.0.80

www.hilti.be
Company: MBG Nobel I UZ Gent - kroon Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: BRACING - TOP PLATE Date: 28/09/2022
Fastening Point:

4 Shear load SOFA (fib (07/2011), section 16.2.2)


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel failure (without lever arm)* 10.000 50.240 20 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout failure** 30.000 175.194 18 OK
Concrete edge failure in direction x+** 30.000 66.685 45 OK

* highest loaded anchor **anchor group (relevant anchors)

4.1 Steel failure (without lever arm)

VRk,s [kN] gM,s VRd,s [kN] VSd [kN]


62.800 1.250 50.240 10.000

4.2 Pryout failure (bond relevant)


0 2
Ap,N [mm ]
2
Ap,N [mm ] y A,Np 2
t Rk,ucr,25 [N/mm ] ccr,Np [mm] scr,Np [mm] cmin [mm]
356,390 245,760 0.000 18.00 247.9 495.7 150.0
0
yc t Rk,cr [N/mm ]
2
max t Rk,cr [N/mm ]
2
k4 y g,Np y g,Np
1.072 9.11 13.70 2.000 1.335 1.122

ec1,V [mm] y ec1,Np ec2,V [mm] y ec2,Np y s,Np y re,Np


0.0 1.000 0.0 1.000 0.882 1.000
0
NRk,p [kN] NRk,p [kN] gM,c,p VRd,cp [kN] VSd [kN]
91.584 131.396 1.500 175.194 30.000

Group anchor ID
1-3

4.3 Concrete edge failure in direction x+

lf [mm] dnom [mm] kV a b


192.0 16.00 1.700 0.113 0.064
0 2
c1 [mm] Ac,V [mm ]
2
Ac,V [mm ] y A,V
150.0 191,250 101,250 1.889

y s,V y h,V y a,V ec,V [mm] y ec,V y re,V y 90°,V


1.000 1.000 1.000 0.0 1.000 1.400 2.500
0
VRk,c [kN] gM,c VRd,c [kN] VSd [kN]
37.825 1.500 66.685 30.000

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

5
Hilti PROFIS Engineering 3.0.80

www.hilti.be
Company: MBG Nobel I UZ Gent - kroon Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: BRACING - TOP PLATE Date: 28/09/2022
Fastening Point:

5 Combined tension and shear loads SOFA (fib (07/2011), section 10.3)
bN bV a Utilization bN,V [%] Status
steel 0.060 0.199 2.000 5 OK
concrete 0.171 0.450 1.500 38 OK

a a
bN + bV <= 1

6 Displacements (highest loaded anchor)


Short term loading:

NSk = 3.704 [kN] dN = 0.0258 [mm]


VSk = 7.407 [kN] dV = 0.2963 [mm]
dNV = 0.2974 [mm]
Long term loading:

NSk = 3.704 [kN] dN = 0.0589 [mm]


VSk = 7.407 [kN] dV = 0.4444 [mm]
dNV = 0.4483 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the baseplate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

7 Warnings
• The anchor design methods in PROFIS Engineering require rigid baseplates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the baseplate are not considered - the
baseplate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required baseplate thickness with CBFEM to limit the stress of the baseplate based on the assumptions explained
above. The proof if the rigid baseplate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be
checked for agreement with the existing conditions and for plausibility!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• Drilled hole cleaning must be performed according to instructions for use (blow twice with oil-free compressed air (min. 6 bar), brush twice,
blow twice with oil-free compressed air (min. 6 bar)).
• Characteristic bond resistances depend on short- and long-term temperatures.
• The design method fib (07/2011) assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by
filling the gap with mortar of sufficient compressive strength (e.g. by using the Hilti Filling set) or by other suitable means
• The compliance with current standards (e.g. EN 1993, AS 4100:1998, etc.) is the responsibility of the user
• Checking the transfer of loads into the base material is required in accordance with fib (07/2011)!
• The characteristic bond resistances depend on the return period (service life in years): 50

Fastening meets the design criteria!

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

6
Hilti PROFIS Engineering 3.0.80

www.hilti.be
Company: MBG Nobel I UZ Gent - kroon Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: BRACING - TOP PLATE Date: 28/09/2022
Fastening Point:

8 Installation data
2 2
Baseplate, steel: S 235; E = 210,000.00 N/mm ; fyk = 235.00 N/mm Anchor type and size: HIT-HY 200-A + HAS-U 8.8 M16
Profile: no profile Item number: 2237090 HAS-U 8.8 M16x260 (insert) /
2022696 HIT-HY 200-A (mortar)
Hole diameter in the fixture: df = 18.0 mm Maximum installation torque: 80 Nm
Plate thickness (input): 25.0 mm Hole diameter in the base material: 18.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 200.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 236.0 mm
Cleaning: Compressed air cleaning of the drilled hole according to instructions
for use is required

Hilti HAS-U threaded rod with HIT-HY 200 injection mortar with 200 mm embedment h_ef, M16, Steel galvanized, Hammer drilling installation
per ETA 11/0493, with annular gaps filled with Hilti Filling Set or any suitable gap solutions

8.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Compressed air with required • Dispenser including cassette and mixer
• Properly sized drill bit accessories to blow from the bottom of • Hilti Filling Set
the hole • Torque wrench
• Proper diameter wire brush

-50.0
y
100.0 100.0
50.0

3
250.0
200.0

2
x
200.0

250.0

1
50.0

50.0 150.0

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -50.0 -200.0 - 150.0 - -
2 -50.0 0.0 - 150.0 - -
3 -50.0 200.0 - 150.0 - -

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

7
Hilti PROFIS Engineering 3.0.80

www.hilti.be
Company: MBG Nobel I UZ Gent - kroon Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: BRACING - TOP PLATE Date: 28/09/2022
Fastening Point:

9 Alternative fastening
9.1 Alternative fastening data

Anchor type and size: HVU2 + HAS-U 8.8 M16_hef1


Return period (service life in years): 50
Item number: 2223835 HAS-U 8.8 M16x190 (insert) / 2164508
HVU2 M16x125 (capsule)
Hilti Filling Set or any suitable annular gap filling solution
Effective embedment depth: hef,act = 125.0 mm, hnom = 125.0 mm
Material: 8.8
Approval No.: ETA-16/0515
Issued I Valid: 13/11/2019 | -
Proof: SOFA design method + fib (07/2011) - after ETAG BOND testing
Stand-off installation: eb = 0.0 mm (no stand-off); t = 25.0 mm

Baseplate :
R lx x ly x t = 200.0 mm x 500.0 mm x 25.0 mm; (Recommended plate thickness: not calculated)

Profile: no profile
Base material: 2
cracked concrete, C40/50, fc,cyl = 40.00 N/mm ; h = 450.0 mm, Temp. short/long: 40/24 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: Reinforcement spacing < 150 mm (any Ø) or < 100 mm (Ø <= 10 mm)
with longitudinal edge reinforcement d >= 12.0 [mm] + close mesh (stirrups, hangers) s <= 100.0
[mm]

Max. Utilisation with HVU2 + HAS-U 8.8 M16_hef1: 50 %


Fastening meets the design criteria!

9.2 Installation data


2 2
Baseplate, steel: S 235; E = 210,000.00 N/mm ; fyk = 235.00 N/mm Anchor type and size: HVU2 + HAS-U 8.8 M16_hef1
Profile: no profile Item number: 2223835 HAS-U 8.8 M16x190 (insert) /
2164508 HVU2 M16x125 (capsule)
Hole diameter in the fixture: df = 18.0 mm Maximum installation torque: 80 Nm
Plate thickness (input): 25.0 mm Hole diameter in the base material: 18.0 mm
Recommended plate thickness: not calculated Hole depth in the base material: 125.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 160.0 mm
Cleaning: Compressed air cleaning of the drilled hole according to instructions
for use is required

Hilti HAS-U threaded rod with HVU2 capsule mortar with 125 mm embedment h_ef, M16_hef1, Steel galvanized, Hammer drilling installation
per ETA-16/0515, with annular gaps filled with Hilti Filling Set or any suitable gap solutions

9.2.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Compressed air with required • HVA square drive shafts
• Properly sized drill bit accessories to blow from the bottom of • Hilti Filling Set
the hole • Torque wrench
• Proper diameter wire brush

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

8
Hilti PROFIS Engineering 3.0.80

www.hilti.be
Company: MBG Nobel I UZ Gent - kroon Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: BRACING - TOP PLATE Date: 28/09/2022
Fastening Point:

10 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior
to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you
put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by
you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with
regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to
interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability
for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

You might also like