You are on page 1of 10

Hilti PROFIS Engineering 3.0.

93

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - Copy - Concrete - Apr 7, 2024 Date: 7/04/2024
Fastening point:

Specifier's comments:

1 Input data
Anchor type and diameter: HSA M10 hnom1
Return period (service life in years): 50
Item number: 2004128 HSA M10x83 20/10/-
Effective embedment depth: hef = 40.0 mm, hnom = 50.0 mm
Material:
Evaluation Service Report: ETA 11/0374
Issued I Valid: 27/10/2023 | -
Proof: Design Method ETAG (No. 001 Annex C/2010)
Stand-off installation: eb = 0.0 mm (no stand-off); t = 10.0 mm

Anchor plate :
R lx x ly x t = 600.0 mm x 250.0 mm x 10.0 mm; (Recommended plate thickness: 5.0 mm)

Profile: Double flat bar, ; (L x W x T) = 250.0 mm x 310.0 mm x 8.0 mm


Base material: uncracked concrete, C25/30, fc,cube = 30.00 N/mm ; h =150.0 mm
2

Installation: hammer drilled hole, Installation condition: Dry


Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement

R
- The anchor calculation is based on a rigid anchor plate assumption.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

1
Hilti PROFIS Engineering 3.0.93

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - Copy - Concrete - Apr 7, 2024 Date: 7/04/2024
Fastening point:

1.1 Load combination


Case Description Forces [kN] / Moments [kNm] Seismic Fire Max. Util. Anchor [%]
1 WL N = 2.029; Vx = 0.000; Vy = 0.000; no no 58
Mx = 0.000; My = 0.000; Mz = 0.000;

2 LL(1) N = 1.080; Vx = 0.000; Vy = 0.000; no no 31


Mx = 0.000; My = 0.000; Mz = 0.000;

3 LL(2) N = 0.800; Vx = 0.000; Vy = 0.000; no no 23


Mx = 0.000; My = 0.000; Mz = 0.000;

4 LL(3) N = 1.656; Vx = 0.000; Vy = 0.000; no no 47


Mx = 0.000; My = 0.000; Mz = 0.000;

2 Load case/Resulting anchor forces


Controlling load case: 1 WL

y
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y x
1 5.181 0.000 0.000 0.000
1
max. concrete compressive strain: 0.07 [‰] Tension
max. concrete compressive stress: 2.03 [N/mm ]
2
Compression
resulting tension force in (x/y)=(0.0/-75.0): 5.181 [kN]
resulting compression force in (x/y)=(0.0/-123.3): 3.152 [kN]

Anchor forces are calculated based on the assumption of a rigid anchor plate.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

2
Hilti PROFIS Engineering 3.0.93

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - Copy - Concrete - Apr 7, 2024 Date: 7/04/2024
Fastening point:

3 Tension load (ETAG, Annex C, Section 5.2.2)


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel Strength* 5.181 20.000 26 OK
Pullout Strength* 5.181 9.056 58 OK
Concrete Breakout Failure** 5.181 9.330 56 OK
Splitting failure** N/A N/A N/A N/A

* highest loaded anchor **anchor group (anchors in tension)

3.1 Steel Strength

N
NSd £ NRd,s = Rk,s ETAG 001 Annex C, Table 5.2.2.1
gM,s

NRk,s [kN] gM,s NRd,s [kN] NSd [kN]


28.000 1.400 20.000 5.181

3.2 Pullout Strength

y c · NRk,p
NSd £ NRd,p = ETAG 001 Annex C, Table 5.2.2.1
gM,p

NRk,p [kN] yc g M,p NRd,p [kN] NSd [kN]


12.400 1.095 1.500 9.056 5.181

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

3
Hilti PROFIS Engineering 3.0.93

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - Copy - Concrete - Apr 7, 2024 Date: 7/04/2024
Fastening point:

3.3 Concrete Breakout Failure

N
NSd £ NRd,c = Rk,c ETAG 001 Annex C, Table 5.2.2.1
gM,c
0 Ac,N
NRk,c = NRk,c · 0
· y s,N · y re,N · y ec1,N · y ec2,N ETAG 001 Annex C, Eq. (5.2)
Ac,N
0 1,5
NRk,c = k1 · √fck,cube · hef ETAG 001 Annex C, Eq. (5.2a)
0
Ac,N = scr,N · scr,N ETAG 001 Annex C, Eq. (5.2b)
c
y s,N = 0.7 + 0.3 · 1.00 ETAG 001 Annex C, Eq. (5.2c)
ccr,N £
hef
y re,N = 0.5 + 1.00 ETAG 001 Annex C, Eq. (5.2d)
200 £
1
y ec1,N = 1.00 ETAG 001 Annex C, Eq. (5.2e)
2 · ec1,N £
1+
scr,N
1
y ec2,N = 1.00 ETAG 001 Annex C, Eq. (5.2e)
2 · ec2,N £
1+
scr,N

2 0 2
Ac,N [mm ] Ac,N [mm ] ccr,N [mm] scr,N [mm]
14,400 14,400 60.0 120.0

ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N


0.0 1.000 0.0 1.000 1.000 1.000
0
k1 NRk,c [kN] gM,c NRd,c [kN] NSd [kN]
10.100 13.995 1.500 9.330 5.181

Group anchor ID
1

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

4
Hilti PROFIS Engineering 3.0.93

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - Copy - Concrete - Apr 7, 2024 Date: 7/04/2024
Fastening point:

4 Shear load (ETAG, Annex C, Section 5.2.3)


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel Strength (without lever arm)* N/A N/A N/A N/A
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength* N/A N/A N/A N/A
Concrete edge failure in direction ** N/A N/A N/A N/A

* highest loaded anchor **anchor group (relevant anchors)

5 Displacements (highest loaded anchor)


Short term loading:

NSk = 3.838 [kN] dN = 0.2517 [mm]


VSk = 0.000 [kN] dV = 0.0000 [mm]
dNV = 0.2517 [mm]
Long term loading:

NSk = 3.838 [kN] dN = 0.5033 [mm]


VSk = 0.000 [kN] dV = 0.0000 [mm]
dNV = 0.5033 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions
explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results
must be checked for agreement with the existing conditions and for plausibility!
• Checking the transfer of loads into the base material is required in accordance with ETAG 001, Annex C(2010)Section 7! The software
considers that the grout is installed under the anchor plate without creating air voids and before application of the loads.
• The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 4.1 of ETAG 001, Annex C! For larger
diameters of the clearance hole see Chapter 1.1. of ETAG 001, Annex C!
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• The characteristic bond resistances depend on the return period (service life in years): 50

Fastening meets the design criteria!

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

5
Hilti PROFIS Engineering 3.0.93

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - Copy - Concrete - Apr 7, 2024 Date: 7/04/2024
Fastening point:

7 Anchor plate stress check


Scope: For the loads / load combinations applied on the anchor plate, an anchor plate stress check is performed (based on the results of a FE
calculation). This stress check contains normal stresses resulting from bending moments in two directions. The user is responsible to select
an anchor plate thickness that meets the requirement per guideline for a rigid anchor plate (to ensure that the assumed load distribution is
(1)
correct). A detailed description can be found in Mallée.

(1)
Mallée, R.; Riemann, H. (1990): Ankerplattenbefestigungen mit Hinterschnittdübeln,
Bauingenieur 65 (1990), S. 49 - 57, Springer VDI-Verlag, 1990
Mallée, R.; Burkhardt, F. (1999): Befestigungen von Ankerplatten mit Dübeln, Beton und
Stahlbetonbau 94, Heft 12, S. 502 - 511, Ernst & Sohn Verlag, 1999

7.1 Base material properties

Steel type: S 275


2
Yield stress: fy = 275.00 [N/mm ]
Partial safety factor: gm,s = 1.000
2
Ultimate strength: fu = 430.00 [N/mm ]
2
Young's modulus: Es = 210,000.00 [N/mm ]
Poisson ratio: n = 0.3

7.2 Results

Relevant load combination: LC 01

Stress distribution s 11

2
90.27 [N/mm ]

2
-12.13 [N/mm ]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

6
Hilti PROFIS Engineering 3.0.93

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - Copy - Concrete - Apr 7, 2024 Date: 7/04/2024
Fastening point:

Stress distribution s 22

2
40.97 [N/mm ]

2
-56.91 [N/mm ]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

7
Hilti PROFIS Engineering 3.0.93

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - Copy - Concrete - Apr 7, 2024 Date: 7/04/2024
Fastening point:

Deformations (z-direction)
0.2 [mm]

-0.1 [mm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

8
Hilti PROFIS Engineering 3.0.93

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - Copy - Concrete - Apr 7, 2024 Date: 7/04/2024
Fastening point:

8 Installation data
2 2
Anchor plate, steel: S 275; E = 210,000.00 N/mm ; fyk = 275.00 N/mm Anchor type and diameter: HSA M10 hnom1
Profile: Double flat bar, ; (L x W x T) = 250.0 mm x 310.0 mm x 8.0 mm Item number: 2004128 HSA M10x83 20/10/-
Hole diameter in the fixture: df = - mm Maximum installation torque: 25 Nm
Plate thickness (input): 10.0 mm Hole diameter in the base material: 10.0 mm
Recommended plate thickness: 5.0 mm Hole depth in the base material: 55.0 mm
Drilling method: Hammer drilled Minimum thickness of the base material: 100.0 mm
Cleaning: Manual cleaning of the drilled hole according to instructions for use is
required.

Hilti HSA stud anchor with 50 mm embedment, M10 hnom1, Steel galvanized, installationwith torque control bar per ETA 11/0374

8.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Manual blow-out pump • Torque controlled cordless impact tool
• Properly sized drill bit • Hilti SFC 22-A drill driver
• Torque wrench
• Installation torque control bar with suitable
screw driver or torque wrench
• Hammer

y
300.0 300.0

125.0
200.0

x
125.0

1
50.0

300.0 300.0

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 0.0 -75.0 450.0 450.0 500.0 200.0

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

9
Hilti PROFIS Engineering 3.0.93

www.hilti.group/content/hilti/CP/XX/en/non-transactional/light-pages/malaysia.html
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Copy - Copy - Concrete - Apr 7, 2024 Date: 7/04/2024
Fastening point:

9 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior
to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you
put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by
you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with
regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to
interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability
for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2024 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

10