1 Input data
Anchor type and diameter: HIT-HY 200 V3 + HIT-Z 3/4
Item number: 2149587 HIT-Z 3/4" x 6 1/2" (element) / 2334276
HIT-HY 200-R V3 (adhesive)
Effective embedment depth: hef,opti = 101.6 mm (hef,limit = 152.4 mm)
Material: DIN EN ISO 4042
Evaluation Service Report: ESR-4868
Issued I Valid: -|-
Proof: Design Method CSA A23.3-14 / Chem.
Stand-off installation: eb = 0.0 mm (no stand-off); t = 8.0 mm
Anchor plate :
R lx x ly x t = 300.0 mm x 300.0 mm x 8.0 mm; (Recommended plate thickness: not calculated)
R
- The anchor calculation is based on a rigid anchor plate assumption.
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
1
Hilti PROFIS Engineering 3.0.79
www.hilti.ca
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - Base plate and anchor rod Date: 04/08/2022
Fastening point:
3 4
Anchor reactions [kN]
Tension force: (+Tension, -Compression) Compression
Anchor Tension force Shear force Shear force x Shear force y
1 1.666 0.043 -0.040 -0.017
2 0.331 0.041 -0.040 -0.011 x
3 1.408 0.048 -0.045 -0.017
Tension
4 0.073 0.046 -0.045 -0.011
Anchor forces are calculated based on the assumption of a rigid anchor plate.
3 Tension load
Load Nf [kN] Capacity Nr [kN] Utilization bN = Nf/Nr Status
Steel Strength* 1.666 83.297 3 OK
Pullout Strength* 1.666 80.755 3 OK
Sustained Tension Load Bond Strength* N/A N/A N/A N/A
Concrete Breakout Failure** 3.477 50.378 7 OK
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
2
Hilti PROFIS Engineering 3.0.79
www.hilti.ca
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - Base plate and anchor rod Date: 04/08/2022
Fastening point:
Variables
2 2
n Ase,N [mm ] futa [N/mm ]
1 216 649.48
Calculations
Ns,uta [kN]
139.994
Results
Ns,uta [kN] fs R Nsar [kN] Nfa [kN]
139.994 0.850 0.700 83.297 1.666
Variables
y c,p la Ncpr,A [kN]
1.000 1.000 124.239
Calculations
-
-
Results
y c,p la Ncpr,A [kN] fc R Ncpr [kN] Nfa [kN]
124.239 0.650 1.000 80.755 1.666
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
3
Hilti PROFIS Engineering 3.0.79
www.hilti.ca
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - Base plate and anchor rod Date: 04/08/2022
Fastening point:
Ncbgr = (AA ) y
Nc
Nc0
ec,N y ed,N y c,N y cp,N Nbr CSA A23.3-14 Eq. D.4
Ncbgr ³ Nfa,g CSA A23.3-14 Table D.1
ANc see CSA A23.3-14, Part D.6.2.1, Fig. D.7
2
ANc0 = 9 hef CSA A23.3-14 Eq. D.5
( )
1
'
y ec,N = 2 eN £ 1.0 CSA A23.3-14 Eq. D.8
1+
3 hef
ef
CSA A23.3-14 Eq. D.11
= MAX(
c ) £
c 1.5h a,min ef
y cp,N , 1.0 CSA A23.3-14 Eq. D.13
c ac ac
1.5
Nbr = kc f c la √ '
fc hef R CSA A23.3-14 Eq. D.6
Variables
' '
hef [mm] e1,N [mm] e2,N [mm] ca,min [mm] y c,N
101.6 76.8 14.9 509.6 1.000
' 2
cac [mm] kc la fc [N/mm ]
152.4 7.0 1.000 32.00
Calculations
ANc [mm ]
2
ANc0 [mm ]
2
y ec1,N y ec2,N y ed,N y cp,N
254,823 92,903 0.665 0.911 1.000 1.000
Results
fc R Nbr [kN] Ncbgr [kN] Nfa,g [kN]
0.650 1.150 30.313 50.378 3.477
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
4
Hilti PROFIS Engineering 3.0.79
www.hilti.ca
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - Base plate and anchor rod Date: 04/08/2022
Fastening point:
4 Shear load
Load Vf [kN] Capacity Vr [kN] Utilization bV = Vf/Vr Status
Steel Strength* 0.048 34.033 1 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength (Concrete Breakout 0.178 132.081 1 OK
Strength controls)**
Concrete edge failure in direction y-** 0.178 78.257 1 OK
Variables
2 2
n Ase,V [mm ] futa [N/mm ]
1 216 649.48
Calculations
Vs,uta [kN]
61.599
Results
Vs,uta [kN] fs R Vsar [kN] Vfa [kN]
61.599 0.850 0.650 34.033 0.048
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
5
Hilti PROFIS Engineering 3.0.79
www.hilti.ca
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - Base plate and anchor rod Date: 04/08/2022
Fastening point:
Nc0
ec,N y ed,N y c,N y cp,N Nbr ]R CSA A23.3-14 Eq. D.45
Vcpgr ³ Vfa,g CSA A23.3-14 Table D.1
ANc see CSA A23.3-14, Part D.6.2.1, Fig. D.7
2
ANc0 = 9 hef CSA A23.3-14 Eq. D.5
( )
1
'
y ec,N = 2 eN £ 1.0 CSA A23.3-14 Eq. D.8
1+
3 hef
ef
CSA A23.3-14 Eq. D.11
= MAX(
c ) £
c 1.5ha,min ef
y cp,N , 1.0 CSA A23.3-14 Eq. D.13
c ac ac
1.5
Nbr = kc f c la √ '
fc hef R CSA A23.3-14 Eq. D.6
Variables
' '
kcp hef [mm] e1,N [mm] e2,N [mm] ca,min [mm]
2 101.6 3.5 10.7 509.6
' 2
y c,N cac [mm] kc la fc [N/mm ]
1.000 152.4 7.0 1.000 32.00
Calculations
ANc [mm ]
2
ANc0 [mm ]
2
y ec1,N y ec2,N y ed,N y cp,N
254,823 92,903 0.977 0.935 1.000 1.000
Results
fc Nbr [kN] Vcpg [kN] R Vcpgr [kN] Vfa,g [kN]
0.650 26.359 132.081 1.000 132.081 0.178
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
6
Hilti PROFIS Engineering 3.0.79
www.hilti.ca
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - Base plate and anchor rod Date: 04/08/2022
Fastening point:
Vcbgr = (AA ) y
Vc
Vc0
ec,V y ed,V y c,V y h,V y a,V(D.7.2.1(c)) Vbr CSA A23.3-14 Eq. D.33
Vcbgr ³ Vfa,g CSA A23.3-14 Table D.1
AVc see CSA A23.3-14, Part D.7.2.1, Fig. D.13
2
AVc0 = 4.5 ca1 CSA A23.3-14 Eq. D.34
( )
1
'
y ec,V = 2ev £ 1.0 CSA A23.3-14 Eq. D.38
1+
3ca1
a1
CSA A23.3-14 Eq. D.41
= 0.58 ( ) √d
l
Vbr
d
e
a f c la √f'c c1.5
a1 R CSA A23.3-14 Eq. D.35
a
Variables
'
ca1 [mm] ca2 [mm] eV [mm] y c,V ha [mm]
339.7 509.6 5.6 1.000 254.0
' 2
le [mm] la da [mm] fc [N/mm ] y a,V(D.7.2.1(c))
101.6 1.000 19.1 32.00 1.000
Calculations
AVc [mm ]
2
AVc0 [mm ]
2
y ec,V y ed,V y h,V
309,677 519,384 0.989 1.000 1.416
Results
fc R Vbr [kN] Vcbgr [kN] Vfa,g [kN]
0.650 1.150 93.685 78.257 0.178
z z
bNV = bN + bV <= 1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
7
Hilti PROFIS Engineering 3.0.79
www.hilti.ca
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - Base plate and anchor rod Date: 04/08/2022
Fastening point:
6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions
explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results
must be checked for agreement with the existing conditions and for plausibility!
• Condition A applies when supplementary reinforcement is used. The R factor is increased for non-steel Design Strengths except Pullout
Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout
Strength. Refer to your local standard.
• Checking the transfer of loads into the base material is required in accordance with CSA A23.3!
• Installation of Hilti adhesive anchor systems shall be performed by personnel trained to install Hilti adhesive anchors. CSA A23.3-14 Annex
D, Clause D.10.1
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
8
Hilti PROFIS Engineering 3.0.79
www.hilti.ca
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - Base plate and anchor rod Date: 04/08/2022
Fastening point:
7 Installation data
Anchor type and diameter: HIT-HY 200 V3 + HIT-Z 3/4
Profile: Rectangular HSS (AISC), HSS7X5X.3125; (L x W x T) = 177.8 mm x Item number: 2149587 HIT-Z 3/4" x 6 1/2" (element) /
127.0 mm x 7.9 mm 2334276 HIT-HY 200-R V3 (adhesive)
Hole diameter in the fixture (pre-setting) : df = 20.6 mm Maximum installation torque: 150 Nm
Hole diameter in the fixture (through fastening) : df = 23.8 mm Hole diameter in the base material: 22.2 mm
Plate thickness (input): 8.0 mm Hole depth in the base material: 101.6 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 203.2 mm
Drilling method: Hammer drilled
Cleaning: Compressed air cleaning of the drilled hole according to instructions
for use is required
3/4 Hilti HIT-Z Carbon steel non-cleaning bonded expansion anchor with Hilti HIT-HY 200 V3 Safe Set System
y
150.0 150.0
50.0
3 4
150.0
200.0
x
150.0
1 2
50.0
Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
9
Hilti PROFIS Engineering 3.0.79
www.hilti.ca
Company: Page: 10