You are on page 1of 10

Hilti PROFIS Engineering 3.0.

79

www.hilti.ca
Company: Page: 1
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - Base plate and anchor rod Date: 04/08/2022
Fastening point:

Specifier's comments:

1 Input data
Anchor type and diameter: HIT-HY 200 V3 + HIT-Z 3/4
Item number: 2149587 HIT-Z 3/4" x 6 1/2" (element) / 2334276
HIT-HY 200-R V3 (adhesive)
Effective embedment depth: hef,opti = 101.6 mm (hef,limit = 152.4 mm)
Material: DIN EN ISO 4042
Evaluation Service Report: ESR-4868
Issued I Valid: -|-
Proof: Design Method CSA A23.3-14 / Chem.
Stand-off installation: eb = 0.0 mm (no stand-off); t = 8.0 mm

Anchor plate :
R lx x ly x t = 300.0 mm x 300.0 mm x 8.0 mm; (Recommended plate thickness: not calculated)

Profile: Rectangular HSS (AISC), HSS7X5X.3125; (L x W x T) = 177.8 mm x 127.0 mm x 7.9 mm


Base material: 2
cracked concrete, fc' = 32.00 N/mm ; h = 254.0 mm, Temp. short/long: 20/20 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: tension: condition A, shear: condition A; no supplemental splitting reinforcement present
edge reinforcement: none or < 15M bar

R
- The anchor calculation is based on a rigid anchor plate assumption.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

1
Hilti PROFIS Engineering 3.0.79

www.hilti.ca
Company: Page: 2
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - Base plate and anchor rod Date: 04/08/2022
Fastening point:

1.1 Design results


Case Description Forces [kN] / Moments [kNm] Seismic Max. Util. Anchor [%]
1 Combination 1 N = 3.013; Vx = -0.169; Vy = -0.056; no 7
Mx = -0.092; My = 0.331; Mz = 0.002;
Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000;

2 Load case/Resulting anchor forces y

3 4
Anchor reactions [kN]
Tension force: (+Tension, -Compression) Compression
Anchor Tension force Shear force Shear force x Shear force y
1 1.666 0.043 -0.040 -0.017
2 0.331 0.041 -0.040 -0.011 x
3 1.408 0.048 -0.045 -0.017
Tension
4 0.073 0.046 -0.045 -0.011

max. concrete compressive strain: 0.01 [‰]


max. concrete compressive stress: 2 1 2
0.23 [N/mm ]
resulting tension force in (x/y)=(-76.8/-14.9): 3.477 [kN]
resulting compression force in (x/y)=(137.8/86.9): 0.464 [kN]

Anchor forces are calculated based on the assumption of a rigid anchor plate.

3 Tension load
Load Nf [kN] Capacity Nr [kN] Utilization bN = Nf/Nr Status
Steel Strength* 1.666 83.297 3 OK
Pullout Strength* 1.666 80.755 3 OK
Sustained Tension Load Bond Strength* N/A N/A N/A N/A
Concrete Breakout Failure** 3.477 50.378 7 OK

* highest loaded anchor **anchor group (anchors in tension)

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

2
Hilti PROFIS Engineering 3.0.79

www.hilti.ca
Company: Page: 3
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - Base plate and anchor rod Date: 04/08/2022
Fastening point:

3.1 Steel Strength

Ns,uta = Ase futa = ESR value refer to ICC-ES ESR-4868


Nsar = Ase f s futa R CSA A23.3-14 Eq. D.2
Nsar ³ Nfa CSA A23.3-14 Table D.1

Variables
2 2
n Ase,N [mm ] futa [N/mm ]
1 216 649.48

Calculations
Ns,uta [kN]
139.994

Results
Ns,uta [kN] fs R Nsar [kN] Nfa [kN]
139.994 0.850 0.700 83.297 1.666

3.2 Pullout Strength

Ncpr,A = ESR value refer to ICC-ES ESR-4868


Ncpr = y c,p Ncpr,A f c la R CSA A23.3-14 Eq. D.15
Ncpr ³ Nfa CSA A23.3-14 Table D.1

Variables
y c,p la Ncpr,A [kN]
1.000 1.000 124.239

Calculations
-
-

Results
y c,p la Ncpr,A [kN] fc R Ncpr [kN] Nfa [kN]
124.239 0.650 1.000 80.755 1.666

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

3
Hilti PROFIS Engineering 3.0.79

www.hilti.ca
Company: Page: 4
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - Base plate and anchor rod Date: 04/08/2022
Fastening point:

3.3 Concrete Breakout Failure

Ncbgr = (AA ) y
Nc

Nc0
ec,N y ed,N y c,N y cp,N Nbr CSA A23.3-14 Eq. D.4
Ncbgr ³ Nfa,g CSA A23.3-14 Table D.1
ANc see CSA A23.3-14, Part D.6.2.1, Fig. D.7
2
ANc0 = 9 hef CSA A23.3-14 Eq. D.5

( )
1
'
y ec,N = 2 eN £ 1.0 CSA A23.3-14 Eq. D.8
1+
3 hef

y ed,N = 0.7 + 0.3 (1.5h


c
) £ 1.0 a,min

ef
CSA A23.3-14 Eq. D.11

= MAX(
c ) £
c 1.5h a,min ef
y cp,N , 1.0 CSA A23.3-14 Eq. D.13
c ac ac
1.5
Nbr = kc f c la √ '
fc hef R CSA A23.3-14 Eq. D.6

Variables
' '
hef [mm] e1,N [mm] e2,N [mm] ca,min [mm] y c,N
101.6 76.8 14.9 509.6 1.000

' 2
cac [mm] kc la fc [N/mm ]
152.4 7.0 1.000 32.00

Calculations
ANc [mm ]
2
ANc0 [mm ]
2
y ec1,N y ec2,N y ed,N y cp,N
254,823 92,903 0.665 0.911 1.000 1.000

Results
fc R Nbr [kN] Ncbgr [kN] Nfa,g [kN]
0.650 1.150 30.313 50.378 3.477

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

4
Hilti PROFIS Engineering 3.0.79

www.hilti.ca
Company: Page: 5
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - Base plate and anchor rod Date: 04/08/2022
Fastening point:

4 Shear load
Load Vf [kN] Capacity Vr [kN] Utilization bV = Vf/Vr Status
Steel Strength* 0.048 34.033 1 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength (Concrete Breakout 0.178 132.081 1 OK
Strength controls)**
Concrete edge failure in direction y-** 0.178 78.257 1 OK

* highest loaded anchor **anchor group (relevant anchors)

4.1 Steel Strength

Vs,uta = ESR value refer to ICC-ES ESR-4868


Vsar = 0.6 Ase,V f s futa R CSA A23.3-14 Eq. D.31
Vsar ³ Vfa CSA A233-14 Table D.1

Variables
2 2
n Ase,V [mm ] futa [N/mm ]
1 216 649.48

Calculations
Vs,uta [kN]
61.599

Results
Vs,uta [kN] fs R Vsar [kN] Vfa [kN]
61.599 0.850 0.650 34.033 0.048

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

5
Hilti PROFIS Engineering 3.0.79

www.hilti.ca
Company: Page: 6
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - Base plate and anchor rod Date: 04/08/2022
Fastening point:

4.2 Pryout Strength (Concrete Breakout Strength controls)

Vcpgr = kcp [(AA ) y Nc

Nc0
ec,N y ed,N y c,N y cp,N Nbr ]R CSA A23.3-14 Eq. D.45
Vcpgr ³ Vfa,g CSA A23.3-14 Table D.1
ANc see CSA A23.3-14, Part D.6.2.1, Fig. D.7
2
ANc0 = 9 hef CSA A23.3-14 Eq. D.5

( )
1
'
y ec,N = 2 eN £ 1.0 CSA A23.3-14 Eq. D.8
1+
3 hef

y ed,N = 0.7 + 0.3 (1.5h


c
) £ 1.0 a,min

ef
CSA A23.3-14 Eq. D.11

= MAX(
c ) £
c 1.5ha,min ef
y cp,N , 1.0 CSA A23.3-14 Eq. D.13
c ac ac
1.5
Nbr = kc f c la √ '
fc hef R CSA A23.3-14 Eq. D.6

Variables
' '
kcp hef [mm] e1,N [mm] e2,N [mm] ca,min [mm]
2 101.6 3.5 10.7 509.6

' 2
y c,N cac [mm] kc la fc [N/mm ]
1.000 152.4 7.0 1.000 32.00

Calculations
ANc [mm ]
2
ANc0 [mm ]
2
y ec1,N y ec2,N y ed,N y cp,N
254,823 92,903 0.977 0.935 1.000 1.000

Results
fc Nbr [kN] Vcpg [kN] R Vcpgr [kN] Vfa,g [kN]
0.650 26.359 132.081 1.000 132.081 0.178

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

6
Hilti PROFIS Engineering 3.0.79

www.hilti.ca
Company: Page: 7
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - Base plate and anchor rod Date: 04/08/2022
Fastening point:

4.3 Concrete edge failure in direction y-

Vcbgr = (AA ) y
Vc

Vc0
ec,V y ed,V y c,V y h,V y a,V(D.7.2.1(c)) Vbr CSA A23.3-14 Eq. D.33
Vcbgr ³ Vfa,g CSA A23.3-14 Table D.1
AVc see CSA A23.3-14, Part D.7.2.1, Fig. D.13
2
AVc0 = 4.5 ca1 CSA A23.3-14 Eq. D.34

( )
1
'
y ec,V = 2ev £ 1.0 CSA A23.3-14 Eq. D.38
1+
3ca1

y ed,V = 0.7 + 0.3 (1.5c


c
) £ 1.0
a2

a1
CSA A23.3-14 Eq. D.41

y h,V = √1.5ch ³ 1.0 a


a1
CSA A23.3-14 Eq. D.42
0.2

= 0.58 ( ) √d
l
Vbr
d
e
a f c la √f'c c1.5
a1 R CSA A23.3-14 Eq. D.35
a

Variables
'
ca1 [mm] ca2 [mm] eV [mm] y c,V ha [mm]
339.7 509.6 5.6 1.000 254.0

' 2
le [mm] la da [mm] fc [N/mm ] y a,V(D.7.2.1(c))
101.6 1.000 19.1 32.00 1.000

Calculations
AVc [mm ]
2
AVc0 [mm ]
2
y ec,V y ed,V y h,V
309,677 519,384 0.989 1.000 1.416

Results
fc R Vbr [kN] Vcbgr [kN] Vfa,g [kN]
0.650 1.150 93.685 78.257 0.178

5 Combined tension and shear loads


bN = Nf/Nr bV = Vf/Vr z Utilization bN,V [%] Status
0.069 0.002 5/3 2 OK

z z
bNV = bN + bV <= 1

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

7
Hilti PROFIS Engineering 3.0.79

www.hilti.ca
Company: Page: 8
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - Base plate and anchor rod Date: 04/08/2022
Fastening point:

6 Warnings
• The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C,
EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the
anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering
calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions
explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results
must be checked for agreement with the existing conditions and for plausibility!
• Condition A applies when supplementary reinforcement is used. The R factor is increased for non-steel Design Strengths except Pullout
Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout
Strength. Refer to your local standard.
• Checking the transfer of loads into the base material is required in accordance with CSA A23.3!
• Installation of Hilti adhesive anchor systems shall be performed by personnel trained to install Hilti adhesive anchors. CSA A23.3-14 Annex
D, Clause D.10.1

Fastening meets the design criteria!

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

8
Hilti PROFIS Engineering 3.0.79

www.hilti.ca
Company: Page: 9
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - Base plate and anchor rod Date: 04/08/2022
Fastening point:

7 Installation data
Anchor type and diameter: HIT-HY 200 V3 + HIT-Z 3/4
Profile: Rectangular HSS (AISC), HSS7X5X.3125; (L x W x T) = 177.8 mm x Item number: 2149587 HIT-Z 3/4" x 6 1/2" (element) /
127.0 mm x 7.9 mm 2334276 HIT-HY 200-R V3 (adhesive)
Hole diameter in the fixture (pre-setting) : df = 20.6 mm Maximum installation torque: 150 Nm
Hole diameter in the fixture (through fastening) : df = 23.8 mm Hole diameter in the base material: 22.2 mm
Plate thickness (input): 8.0 mm Hole depth in the base material: 101.6 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 203.2 mm
Drilling method: Hammer drilled
Cleaning: Compressed air cleaning of the drilled hole according to instructions
for use is required

3/4 Hilti HIT-Z Carbon steel non-cleaning bonded expansion anchor with Hilti HIT-HY 200 V3 Safe Set System

7.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • - • Dispenser including cassette and mixer
• Properly sized drill bit • Torque wrench

y
150.0 150.0
50.0

3 4
150.0
200.0

x
150.0

1 2
50.0

50.0 200.0 50.0

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -100.0 -100.0 509.6 709.6 509.6 709.6
2 100.0 -100.0 709.6 509.6 509.6 709.6
3 -100.0 100.0 509.6 709.6 709.6 509.6
4 100.0 100.0 709.6 509.6 709.6 509.6

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

9
Hilti PROFIS Engineering 3.0.79

www.hilti.ca
Company: Page: 10
Address: Specifier:
Phone I Fax: | E-Mail:
Design: Drafts_Concrete - Base plate and anchor rod Date: 04/08/2022
Fastening point:

8 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior
to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you
put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by
you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with
regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to
interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability
for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for conformity with the existing conditions and for plausibility!
PROFIS Engineering ( c ) 2003-2022 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

10

You might also like