BATTERY PREVENTIVE MAINTENANCE

Preventive Maintenance

BENEFITS

Protect Power System Availability


Arguably the weakest links in the
power chain, batteries are historically
a leading root cause of data center
downtime. A single bad cell in a
string can put your entire backup
power system at risk.

Whether you use vented lead-acid


(VLA), valve-regulated lead-acid
(VRLA), nickel-cadmium (NiCad), or
lithium-ion (Li-ion), adhering to best
practices for maintenance and testing
is essential for increasing mean time
between failures (MTBF). Often, it is
also a requirement for maintaining a
valid product warranty.

A proper battery maintenance


program that identifies system Maximize service life and eliminate battery-related downtime
anomalies and trends end-of-life with regular and comprehensive preventive maintenance
allows you to repair or replace
batteries before they fail. Batteries are one of the least technical Our battery preventive maintenance
components in your UPS, yet one of the services include:
Benefits most critical. They are electrochemical
yyComplete visual inspection
yy Achieve greater availability and devices that require regular checks to
reliability of your UPS system ensure safe and proper operation. yyBattery measurement
yy Have better insight to From the moment they are placed into yyCorrective maintenance
battery health service, batteries begin to deteriorate due and replacement
to use and environmental conditions. The
yy Experience less best way to ensure high availability is yyComprehensive report
unplanned downtime through a comprehensive preventive
yy Improve battery performance maintenance program. When this program
is executed by a team that performs
yy Extend the useful service life millions of battery transactions a year, while
of your batteries adhering to all manufacturer and Institute
of Electrical and Electronics Engineers
(IEEE) standards, you’ll maximize service
life and minimize downtime.

1
BATTERY PREVENTIVE MAINTENANCE

Complete Visual Inspection Corrective Maintenance


& Replacement Summary
During preventive maintenance visits,
Vertiv™ works to minimize battery-related Visual inspection can identify the need to Batteries are one of the least
UPS failures by performing a complete have cell connections refurbished. This technical components in your UPS,
visual inspection in which our technicians corrective maintenance will be performed making it easy to overlook their
do the following: during the regular maintenance visit. importance in providing backup
yyLook for evidence of corrosion Additionally, essential or preferred power. As a result, UPS battery
contract customers may require the failure is the most common cause of
yyCheck appearance and cleanliness replacement of defective lead-acid unplanned outages.
of battery, rack/cabinet, and batteries. When the battery string meets
From the moment they are placed
battery room Vertiv’s defined conditions, technicians
into service, batteries begin to
will perform replacement as needed.
yyRemove dirt accumulation on the top deteriorate due to use and
of jars Comprehensive Report environmental conditions. The best
way to ensure high availability is
yyInspect for cracks, leaks, or bad cells, Measurement and test results are through a comprehensive
and check connection torques compiled into a detailed report. This preventive maintenance program.
report notes any deficiencies, as well
yyRe-tighten battery connections per as corrective action needed, taken As part of a proactive battery
manufacturer’s specifications and/or planned. management strategy, preventive
(if needed) maintenance optimizes battery
performance and reliability to
Battery Measurement ensure business continuity.
A variety of critical battery parameters Ordering Information
are measured and recorded during
preventive maintenance visits. These To learn more about this service
measurements include: and other Vertiv solutions, visit
VertivCo.com or call
yyTotal float voltage and 1-800-543-2378.
charging current

yyOverall AC ripple voltage and current

yyAmbient temperature

yyTemperatures and float voltage of all


individual jars

yyConnection resistances

yyAll internal ohmic readings