N-6 and N-12 • The alarm message is maintained on the screen once
the fault clears and until it is manually reset
Optimized user interface for easy • Last five alarms are stored in alarm log
operation
Protection
Backlighted alphanumeric multisymbol LCD-display
and ergonomic push buttons enable: • If necessary, the capacitor steps are automatically
disconnected to protect the equipment
• Viewing of electrical information
• Easy browsing in the menus
• Multilingual usage
• Alarm indications
NC-12
Performance
For more advanced power factor
• Intelligent stepping algorithm for optimum step controlling
utilization and fast response
• All traditional stepping sequences also available In addition to the functions of N-6/N-12, the NC-12
provides the following additional features:
Simplified installation and set-up • Measurement of total current harmonic distortion
• Quick and simple mounting and wiring • Graphical analysis of network harmonic currents and
• Insensitive to current transformer polarity and phase voltages
rotation polarity • Possibility of a dual target cos
• A special menu allows controller self-configuration • Possible to configurate steps permanently switched
off or on
Monitoring and protection • Step condition monitoring
• Time stamped alarm log
Alarms • On-line help menus
• Should a disturbance occur on the network or in
the capacitor bank, alarms are indicated on the
A communicating model
screen and alarm contact closure is initiated • Optional communication auxiliary (RS485 Modbus)
N-12 connection examples Technical specification
General data
• Operating temperature: 0…60°C
• Storage temperature: -20°C…60°C
• Colour: RAL 7016
• Standards:
Line-to-Line EMC:
connection - immunity according to IEC 61000-6-2
- emissions according to IEC 61000-6-4
Electrical safety and low voltage directive according
to IEC 61010-1
• Mounting mechanism: panel mounting,
138mmx138mm panel cutout or mounting on
35mm DIN-rail (EN 50022)
• Protection class: IP 41 front face, IP 20 rear face
• Display type:
- N-6 and N-12 backlighted symbol LCD
- NC-12 backlighted dot matrix LCD
• Languages: English, German, French, Portuguese,
Spanish, Swedish, Finnish
• Alarm contact
• Separate fan relay contact
• Temperature measurement:
Line-to-Neutral - N-6 and N-12 with internal temperature probe
connection - NC-12 with optional external temperature probe
• Alarm log
• Serial communication port: RS 485, industry
standard buses with optional communication
adapter (NC-12 type)
Inputs
• Type of connection: phase to phase or phase
to neutral
• Insensitive to CT polarity
NC-12 connection examples • Insensitive to phase rotation polarity
• CT ratio range: 25/5A…6000/5A (all types)
• CT ratio range: 25/1A…6000/1A (NC-12 type only)
Outputs
Line-to-Line
connection • Potential free output contacts:
AC: 1A/400V, 2A/250V, 5A/120V
DC: 0.3A/110V, 0.6A/60V, 2A/24V
Optional accessories
Cos x x
Connected steps x x
Switching counter and duty cycles x x
Network technical data: I, U, S, P, Q x x
Temperature of the capacitor bank x x
Total voltage harmonic distortion THD (U) x x
Alarm log x x
Step status (fixed, auto, disconnected) x
Step capacitance monitoring x
Total current harmonic distortion THD (I) x
Capacitor overload Irms/I1 x
Voltage and current harmonic spectrum x
(1)
alarm threshold values can be configured
In line with our policy of on-going product development we reserve the right to alter specifications.