Single Diaphragm
DN100
APPROVALS
GOST-R
EN 837-3
STANDARD SPECIFICATIONS
Dial size : DN100 / DN125 / DN150
? P Range : 0...25 mbar up to 0...25 bar
Mounting pattern : Direct, Bottom connection
Process connection : ¼" NPT (F) x 2 Nos. [HIGH & LOW]
Ingress protection : IP 65
Execution : Dry
www.itec.it P3-07
P302 DIFFERENTIAL PRESSURE GAUGE
DIMENSIONAL DRAWING
Type R2
B ØU Ø6.0 x 3 Nos.
A ØN
120°
ØD
Q ØC
RANGE TABLE
GUIDE TO MAKE RANGE CODE
1. To make range code, use “Unit of Measurements” first (UOM CODE) together with the “RANGE CODE” by replacing ‘x’.
Example; single scale ‘0...10 bar’ shall be B110, dual scale ‘0...10 kg/cm²/psi’ shall be L110
2. Approximate unit conversion; 1 bar = 1.019 kg/cm² = 14.503 psi = 100 kPa = 750.061 mmHg = 1000 mbar = 10197 mmWC
3. For custom dial design, contact ITEC.
psi E mmWC H
kPa S Inch WC 5
kg/cm² K
TEMPERATURE EFFECT
The variation of indication caused by effects of temperature is to be calculated as per the below formula; which is to be added in the specified accuracy while measurement :-
Formula: ± 0.04 x (t2 - t1)% of Full Scale Value
Where t1 = reference temperature (+20°C) & t2 = ambient temperature in °C.
www.itec.it P3-09
P302 DIFFERENTIAL PRESSURE GAUGE
DIMENSIONAL DRAWING
Type B0
F B
A
ØD
ØC
Type B1
F
M B
A R
Q
ØD
L P ØC S
Type B2
F B O
2" Pipe Mounting
Bracket.
A
D
C
J P
ORDERING CODES
1. DIAL SIZE
04
04 100 mm / 4" 05 125 mm / 5" MAGNETIC CONTACTS [PRECISION]
RATING: 230VAC@1A / 48VDC@0.5A
06 150 mm / 6”
CD1 Break contact (1NC)
2. ? P RANGE CD2 Make contact (1NO)
XXXX CD3 2 x Break contact (2NC)
XXXX Refer "Range Table" CD4 2 x Make contact (2NO)
CD5 1 Break + 1 Make (1NC+1NO)
3. MOUNTING PATTERN CD6 1 Make + 1 Break (1NO+1NC)
B0
B0 Direct, Bottom connection CD7 SPDT
B1 Wall/Surface/Projection mounting, Bottom CD8 DPDT
connection INDUCTIVE CONTACTS [ATEX / CE Approved]
B2 2" Pipe/Yoke mounting, Bottom connection RATING: 8VDC@3mA
R2 Panel/Front flange mounting, Centre Back CI1 Break contact (1NC)
connection CI2 Make contact (1NO)
CI3 2 x Break contact (2NC)
4. PROCESS CONNECTION [2 ports: HIGH/LOW] CI4 2 x Make contact (2NO)
02N CI5 1 Break + 1 Make (1NC+1NO)
02N ¼" NPT (F) 13B 3/8" BSP (M)*
CI6 1 Make + 1 Break (1NO+1NC)
14N ½" NPT (M)* 14B ½" BSP (M)*
14M M20 X 1.5 mm (M)* RELAY [FOR RATING UP TO 5A]
*Male threads through adaptors. CI9 Booster relay
Other thread sizes and standards are available.
Gauge accuracy shall be CL 1 & switching accuracy shall be CL 5
5. INGRESS PROTECTION
ER 10. OTHER OPTIONS
ER IP 65 XX
BA Case & Ring in AISI 316 SS (B0)
6. EXECUTION BB Case & Ring in AISI 316 SS (B1)
EA BC Case & Ring in AISI 316 SS (B2)
EA Dry
BI Case & Ring in AISI 316 SS (R2)
Rev 01
EG Dampening liquid filled, glycerine
GL AISI 316 SS movement
EH Dampening liquid filled, silicon oil
GM Dampened movement
EK Dampening liquid, dielectric oil
Options EH / EK will be suppled with Viton rubber parts. GZ External zero adjustment
© 2016 ITEC All rights reserved. Technical specifications are as such at the time of printing. Changes and omissions may happen.
G6 6 pin, M20 x 1.5 mm connector
7. CHAMBER MATERIAL RA Rubber parts, Viton
MC RW Vent plug, ON-OFF type
MC AISI 304 SS MF AISI 316 SS
TA 5 - point calibration certificate
MG AISI 316L SS MN Monel 400
TC Material test certificate 3.1
TM Material test certificate 2.2
8. DIAPHRAGM MATERIAL
DF TN Tested to NACE standards
DF AISI 316 SS DN Monel 400 XF SS tag plate, AISI 304 SS
DG AISI 316L SS XG SS tag plate, AISI 316 SS
8. OPTION: ELECTRIC CONTACTS & RELAYS XR Custom designed dial
XXX XT Dial tag marking
MAGNETIC CONTACTS [ECONOMIC]
RATING: 230VAC@1A / 48VDC@0.5A
CS1 Break contact (1NC)
CS2 Make contact (1NO)
CS3 2 x Break contact (2NC)
CS4 2 x Make contact (2NO)
CS5 1 Break + 1 Make (1NC+1NO)
CS6 1 Make + 1 Break (1NO+1NC)
Ordering Example : P302-04-XXXX-B0-02N-ER-EA-MC-DF
COMPATIBLE ACCESSORIES
CODE DESCRIPTION CODE DESCRIPTION
DXXX Diaphragm seals M103 Three valve manifolds
M105 Five valve manifolds
P3-10 A635 Capillary extension / Impulse tube
www.itec.it