You are on page 1of 4

PRE-LIMINARY COLUMN DE

Dead Load Li

L.L 1
L (horizontal) 25 ft   L.L 2
W (vertical) 25 ft Roof Live
Thickness of Slab 0.5833 ft
Conc. Density 150 lb/ft3
S1
Partition Wall 25 S2
Finishes 40 S3
S4
Assumed Beam S5
Width 1 ft S6
Depth 2 ft S7
S8
Assumed Col S9
Length 2 ft S10
Width 2 ft S11
Height 8.5 ft S12
S13
S.W of Slab 54684.38 S14
S.W of Partition Wall 15625 S15
S.W of Finishes 25000
S.W of Beam 15000
S.W of Column 5100

Total Load of 1 Storey 115409.4
For All Stories
Total D.L 1384913 lb

Wu 2161895 lb

Pu 2161.895 kips

ULTIMATE LOAD ON COLUMN
Pu (EQ) 2810.464 kips

fc' 3 ksi
fy 60 ksi
Ast (%) 0.01
fi(Ø) 0.65

Area of Column 2119.75 sq. inch


Proposed Col Size (in) 46 X 46
ESIGN

ive Load Stories 12

50 psf
40 psf
25 psf

Total Story Load
31250 31250
31250 31250
25000 25000
25000 25000
25000 25000
25000 25000
25000 25000
25000 25000
25000 25000
25000 25000
25000 25000
25000 25000
25000 0
25000 0
15625 0

Total L.L 312500 lb
46.04074