Vo = Air velocity at face of hood, fpm Q = Required flow through hood, cfm X/D D = Diameter of round hood, ft 2.5 L = Length of Rectangular hood, ft W = Width of rectangular hood, ft A1 = Face area of round hood, sqft A2 = Face area of rectangular hood, sqft
Round hood Round hood, flanged
D L W x Vx A1 A2 Vo Q Vo Q ALFA BETA 0.4 2 2 1 200 0.1257 4 16116 2024 8664 1089 0.500 0.492 Rectangular hood Rectangular hood, flanged Vo Q Vo Q 615 2460 534 2137