You are on page 1of 4
ISG OY V2 SCANIA service FUEL HEATER yh) Contents Function description Work description Installation ot heater and thermo switch Wiring © Saab-Scania AB 1985 3:298 3 3-85 11 27 GT EN Function description SCANIA service Function description ‘Atuel heateris used for counteracting diesel fuel ol waxing in cold weather. Waxin the fue! causes the fue itrs to clog up and this can cause the engine to lose outputor stall ‘The fuel heater operates with electiciy ands ited between the first fue! ter and the cleaner cover. Heatingis controled by athermoswitch thats foundinthe inlet ofthe cleaner on 8, 9and 11 enginesandinthe outlet from the fuel pump on the 14 engines. ‘The thermoswitch turnson the heater viaa relay when the temperaturein the diesel fuel round the thermoswitch is 0°C or, lower. The heateris turned off when tueltemperature reaches 48°C. ‘The thermoswitch activates the relay. The relay turns the heater offor on when the alternator supplies power. status light on the instrument pane! comes on when the heateris turnedon, © Saab-Scania AB 1985 Status light 3-85 11 27 GT EN J Work description service Work description Installation of heater and thermoswitch Warning Beware of diesel fuel, use protective gloves. Remove first fue! iter. Fitseals on heater. Fiter heater and replace fier. 8,9and 11 engines: Remove banjo union screw trominiet tocleaner cover. ‘engines: Remove banjo union screw trom outieton fuel pump. ‘Attach fuel pipe with thermoswitch banjo union screw. Fitthermoswitch in banjo union screw. Bleed uel system with hand pump. Fitting of heater and thermoswitch 3-85 11 27 GTEN © saa sania AS 1985 Work description Wiring 1 2 Open cover of electric central unit. LHD trucks: Remove cover over fan. HD trucks: Remove covers roundsteering column. Remove on of the status ight panels by the steering whee! SCANIA service 8. Fit relay in vacant position in central unit according to wiring diagram below. ‘9. Connectwires to relay and tuse 3 on tuse panel 98, Note. Fuse has tobe rated or 25A (16A for 12V system) 10. Connect wire hamess from heater and thermoswitch to Connect wire harnesses forheater and thermoswitchto heater and thermoswitch Connect earth wiresto earth connection 308 by radiator frame, Route wire haress into cab. Place other wire harness under instrument panel. instrument panel harness. 12, Fitcovers. Electric central unit Fusepanel Monitor Earth connection Earth connection 1266 1267 1378 1374 Circuit diagram G-1985,38922 Fuelheater Relay Status ight Junetion block, 2-pole 11. Connect status light and earth light o earth screw 302. Fit lightand panel he e @ Lg 3-85 1127 GTEN

You might also like