You are on page 1of 2

1700

400 300

625
2500

2200
400
700

500 1000 500 2000 2000


200 1000 2000 2000 2000 2000 2000 2000 2000 2000 2000 1000 200
6000
20000
FRONT ELEVATION END ELEVATION
SIDE ELEVATION
2000
6000
2000

MATERIALS PER GREEN HOUSE


1. 6 fans per Green house
2000

2. 4 doors 1000 x 2200 high


3. Fine mesh
Top Fan

Pipe frame PLAN


Purlin Rafter
Roll up Chord Strut
Eave DRYING RACKS

Drying CEMENTED WALK WAY RAIL FACILITY FO THE DISABLED


Racks

Ground DRYING RACKS


Footer
Level

SECTIONAL VIEW
FLOOR PLAN

Drawing title: Consultants:


REV. DESCRIPTION SIGN DATE Project:
1. All dimensions are in millimeters unless otherwise specified. Dimensions to be read not scaled. GREENHOUSE DESIGN FOR GREENHOUSE DESIGN FOR Robert M. Mathenge.
1. DISABLED FARMERS. AREA DISABLED FARMERS. AREA TEL:+254 720 459 526 MA
CAD C

EN
ROMW

TRE
2. Approvals to be done prior to commencing construction. Any discrepancy to be reported before any further works. EMAIL: romwama@gmail.com
2.
3. This drawing to be used in conjunction with relevant structural drawings. 3. romwama@gmail.com

Client: R. Mathenge
Drawn:............................ Sheet No.
1 of 2
4. Adequate drainage shall be maintained at all times during construction and any drainage ditch or structure disturbed G.NORTH & SON LTD. Checked......................... Drawing No. 001- 2021
TEL: +254-020-2343860/234859/2343869, Cell: 0722691646/0733616653
during construction shall be restored to existing conditions or better. WEBSITE: http://gnorth.co.ke Approved.........................
EMAIL: agriculture@gnorth.co.ke 28/02/2021
Date: ...............................
FULL ASSEMBLY

OPEN AT THE TOP

ARRANGEMENT OF
DRYING RACKS, RAIL
AND FLOOR PLAN

Drawing title: Consultants:


REV. DESCRIPTION SIGN DATE Project:
1. All dimensions are in millimeters unless otherwise specified. Dimensions to be read not scaled. GREENHOUSE DESIGN FOR GREENHOUSE DESIGN FOR Robert M. Mathenge.
1. DISABLED FARMERS. AREA DISABLED FARMERS. AREA TEL:+254 720 459 526 AM
A CAD CE

ROMW

NT
RE
2. Approvals to be done prior to commencing construction. Any discrepancy to be reported before any further works. EMAIL: romwama@gmail.com
2.
3. This drawing to be used in conjunction with relevant structural drawings. 3. romwama@gmail.com

Client: R. Mathenge
Drawn:............................ Sheet No.
ISOMETRIC VIEW 2 of 2
4. Adequate drainage shall be maintained at all times during construction and any drainage ditch or structure disturbed G.NORTH & SON LTD. Checked......................... Drawing No. 001- 2021
TEL: +254-020-2343860/234859/2343869, Cell: 0722691646/0733616653
during construction shall be restored to existing conditions or better. WEBSITE: http://gnorth.co.ke Approved.........................
EMAIL: agriculture@gnorth.co.ke 28/02/2021
Date: ...............................