File MH28652 Page T1-1 of 62 Issued: 2017-11-28

TEST RECORD NO. 1

GENERAL

The manufacturer submitted samples to be evaluated in accordance NFPA 2112,


Standard on Flame-Resistant Clothing for Protection of Industrial Personnel
Against Short-Duration Thermal Exposures from Fire 2018 Edition (2017-09-06).
Results of testing were in compliance with the requirements.

Test Results relate only to the items tested.

SAMPLES
MPG S000106871 Westex® DH

TESTS PER NFPA 2112-2018

Flame Resistance
Heat & Thermal Shrinkage Resistance
Heat Transfer Performance (HTP)
Manikin (Testing performed at NCSU)

NOTES:

Per the manufacturer’s request the following fabrics were removed from this
file as follows:

Fabric Style File Volume Section

MPG S000106002 Nomex® CXP® MH28652 1 3

Springfield DH EW MH28652 4 1

Nomex MHP 80 MH28652 4 3


File MH28652 Page T1-2 of 62 Issued: 2017-11-28

NOTES (CONT’D):

The following fabrics have a suffix at the end of the 9 numerical characters
of each style that represent a finish as shown in the following table. These
finishes do not interfere with the performance of the fabrics. All the finishes
have been previously applied to different fabrics without showing any
significant result differences from one another.
There are also some fabrics with the exact same composition but have two
different styles either because one is a wider version of the other or
because one uses a natural fiber versus a solution-dyed aramid fiber. None of
these special characteristics affect the performance of the fabric and
therefore no additional testing was necessary.

Fabric style Finish Special Characteristics


MPG S00010624X Westex®
MPG S00010614X Westex® Synergy® or Synergy® is a wider
MPG S00010624X Westex® Synergy® X indicates version of MPG S00010614X
“finish” as Westex® Synergy®
follows: MPG S00010626X Westex®
MPG S00010616X Westex® Synergy® or 1=Freedom Synergy® is a wider
MPG S00010626X Westex® Synergy® 3=Autoclave version of MPG S00010616X
5=Hydropel Westex® Synergy®
6=Comfort
MPG S00010615X Westex® Synergy®
Freedom
MPG S00010646X Westex® Synergy®
MPG S00010617X Westex® Synergy®
MPG S00010634X Westex® Synergy®
MPG S00010682Y Westex® DH
uses natural fiber
MPG S00010682Y Westex® DH or
MPG S00010683Y Westex® DH
MPG S00010683Y Westex® DH
uses solution-dyed aramid
fiber
MPG S00010686Y Westex® DH
uses natural fiber
MPG S00010686Y Westex® DH or Y indicates
MPG S00010687Y Westex® DH
MPG S00010687Y Westex® DH “finish” as
uses solution-dyed aramid
follows:
fiber
1=SD Wick Q
MPG S00010688Y Westex® DH
2=Wick G
uses natural fiber
MPG S00010688Y Westex® DH or 7=Hydropel
MPG S00010689Y Westex® DH
MPG S00010689Y Westex® DH
uses solution-dyed aramid
fiber
MPG S00010680Y Westex® DH
uses natural fiber
MPG S00010680Y Westex® DH or
MPG S00010681Y Westex® DH
MPG S00010681Y Westex® DH
uses solution-dyed aramid
fiber
Z indicates
MPG S00010670Z Nomex™ MHP
“finish” as
uses natural fiber
MPG S00010670Z Nomex™ MHP or follows:
MPG S00010671Z Nomex™ MHP
MPG S00010671Z Nomex™ MHP 1=Wick Q
uses solution-dyed aramid
2=Wick G
fiber
7=FC
File MH28652 Page T1-3 of 62 Issued: 2017-11-28

NOTES (CONT’D):

Testing in accordance with CAN/CGSB 155.20 can be found under File MH28652,
Volume 4 in accordance with the following table:

Test
Old Style Designation New Style Designation Section Record
No
MPG S00010686y Westex® DH or
Springfield DH 1 2
MPG S00010687y Westex® DH
MPG S00010688y Westex® DH or
Springfield DH BW 1 5
MPG S00010689y Westex® DH
MPG S00010682y Westex® DH or
Springfield DH TW 1 5
MPG S00010683y Westex® DH
MPG S00010614x Westex® Synergy® or
Synergy 4531 1 1
MPG S00010624x Westex® Synergy®
Synergy 6531/6581 MPG S00010616x Westex® Synergy® or
1 1
Synergy 6532 MPG S00010626x Westex® Synergy®
MPG S000106169 Westex
MPG S000106159 Westex AllOut 1 9
AllOut
Protera 165-2012 MPG S000106611 Protera 3 2
Protera 175-2012 MPG S000106651 Protera 3 1
Protera 180-2012 MPG S000106621 Protera 3 1
MPG S00010670z Nomex™ MHP or
Nomex MHP 70 3 3
MPG S00010671z Nomex™ MHP

The style designation changes were only editorial and do not affect in any
way the performance of the fabric.

The following editorial changes in fabric composition were made per


clarification of the manufacturer. These changes are only editorial and do
not imply that the fabrics have changed in any way.

New composition per


Style Designation Old Composition manufacturer’s
clarification
Protera 165-2012 or 65% Modacrylic/35% 62% Modacrylic/ 36%
MPG S000106611 Protera Aramid Aramid/ 2% P-140
Protera 175-2012 or 65% Modacrylic/35% 62% Modacrylic/ 36%
MPG S000106651 Protera Aramid Aramid/ 2% P-140
Protera 180-2012 or 65% Modacrylic/35% 62% Modacrylic/ 36%
MPG S000106621 Protera Aramid Aramid/ 2% P-140

Per customer clarification the nominal weight for fabric Style MPG S00010689Y
Westex® (Springfield DH BW) should be 8.5 osy instead of 9.0 osy. This is
only an editorial change and does not imply that the fabric has been modified
in any way.
File MH28652 Page T1-4 of 62 Issued: 2017-11-28

METHOD FOR MASS PER UNIT AREA (WEIGHT) OF ASTM D3776, SECTION 9
FABRIC

Fabric Identification Measured Weight (oz/yd2)


MPG S000106871 Westex® DH 8.24
File MH28652 Page T1-11 of 62 Issued: 2017-11-28

FLAME RESISTANCE TEST (CONT’D) NFPA 2112-2018, SECTION 8.3

Item Type Garment Fabric


MPG S000106871 Westex® DH, 48% Tencel/ 40% Modacrylic/ 12%
Description
Aramid, Twill
Color Black or Navy
Weight 7.5
DO SPECIMENS COMPLY WITH THE REQUIREMENTS OF THE STANDARD [YES/NO] YES

Warp (Wales) Fill (Courses)


Char Melt/ Char Melt/
Conditioning Specimen Afterflame Afterflame
Length Drip Length Drip
(s) (s)
(mm) [Y/N] (mm) [Y/N]
1 0.00 72 N 0.00 28 N
2 0.00 68 N 0.00 27 N
3 0.00 63 N 0.00 34 N
As Received
4 0.00 53 N 0.00 26 N
5 0.00 60 N 0.00 28 N
Average 0.00 63 N/A 0.00 29 N/A
Requirement < 2 < 100 N < 2 < 100 N
1 0.00 55 N 0.00 30 N
2 0.00 61 N 0.00 55 N
After 100 3 0.00 57 N 0.00 25 N
Launderings 4 0.00 68 N 0.00 26 N
5 0.00 55 N 0.00 33 N
Average 0.00 59 N/A 0.00 34 N/A
Requirement < 2 < 100 N < 2 < 100 N
Software Validation: 76083
File MH28652 Page T1-25 of 62 Issued: 2017-11-28

HEAT AND THERMAL SHRINKAGE RESISTANCE TEST NFPA 2112-2018, SECTION 8.4
(CONT’D)

Item Type Garment Fabrics


MPG S000106871 Westex® DH, 48% Tencel/ 40% Modacrylic/ 12%
Description
Aramid, Twill
Color Black or Navy
DO SPECIMENS COMPLY WITH THE REQUIREMENTS OF THE STANDARD [YES/NO] YES

Warp Percent Average Fill Percent Average


Conditioning Specimen Shrinkage Percent Shrinkage Percent
1 2 3 Shrinkage 1 2 3 Shrinkage
1 0.0 0.5 0.0 0.2 -1.0 -1.0 -1.0 -1.0
As Received 2 0.5 0.5 0.5 0.5 -1.0 -1.0 -1.0 -1.0
3 0.5 1.0 0.5 0.7 -1.0 -0.5 -1.0 -0.8
Average 0 Average -1
Requirement > -10 Requirement > -10
1 0.5 0.5 0.0 0.3 -1.0 -1.0 -1.0 -1.0
After 3
2 0.5 0.5 0.5 0.5 -1.0 -1.0 -1.0 -1.0
Launderings
3 0.5 0.5 0.5 0.5 -1.0 -1.0 -1.0
Average 0 Average -1
Requirement > -10 Requirement > -10

Conditioning As Received After 3 Launderings

Specimen 1 2 3 Specimen 1 2 3

Observation Melt & Drip N N N Melt & Drip N N N


[Y/N]
Separate N N N Separate N N N
Ignite N N N Ignite N N N
Requirement N N N N N N

Positive values indicate increase in dimensions. Negative


PH Comments
values indicate shrinkage.
File MH28652 Page T1-40 of 62 Issued: 2017-11-28

HEAT TRANSFER PERFORMANCE TEST (HTP) (CONT’D) NFPA 2112-2018, SECTION 8.2

Item Type Garment Fabrics


MPG S000106871 Westex® DH, 48% Tencel/ 40% Modacrylic/ 12%
Description
Aramid, Twill
Color Black or Navy
DO SPECIMENS COMPLY WITH THE REQUIREMENTS OF THE STANDARD [YES/NO] yes

Contact Test HTP Rating Spaced Test HTP Rating


2 2
(cal/cm ) (cal/cm )
Specimen
After 3 After 3
As Received As Received
Launderings Launderings
1 8.9 10.7 11.0 12.1
2 8.4 10.6 10.7 12.3
3 8.7 10.2 11.0 12.2
Average 8.7 10.5 10.9 12.2
Requirement > 3.0 > 3.0 > 6.0 > 6.0
Individuals
within 10% of Y Y Y Y
Average [Y/N]
Requirement Y Y Y Y
Software Validation: 76083
File MH28652 Page T1-54 of 62 Issued: 2017-11-28

MANIKIN TEST (CONT’D) NFPA 2112-2018, SECTION 8.5

Item Type Fabric – Standard Coveralls


MPG S000106871 Westex® DH, 7.5, 48% Tencel/40% Modacrylic/12%
Description
Aramid, Twill
Report ID 170816D, 170816E,170816F
DO SPECIMENS COMPLY WITH THE REQUIREMENTS OF THE STANDARD [YES/NO] YES

Predicted Percent Total


Conditioning Specimen
Body Burn
1 9.84
2 13.11
After 1 Laundering
3 10.66
Average 11.20
Requirement < 50
File MH28652 Page T1-62 of 62 Issued: 2017-11-28

Test Record No. 1 Summary

The results of this investigation, including construction review and testing,


indicate that the products evaluated comply with the applicable requirements
in NFPA 2112, Standard on Flame-Resistant Clothing for Protection of Industrial
Personnel Against Short-Duration Thermal Exposures from Fire 2018 Edition
(2017-09-06) and CAN/CGSB 155.20, Standard on Workwear for Protection Against
Hydrocarbon Flash Fire, 2000 Edition (2000-09-01) and, therefore, such
products are judged eligible to bear UL's Mark as described on the Conclusion
Page of this Report.

Any information and documentation involving UL Mark services are provided on


behalf of UL LLC or any authorized licensee of UL.
File MH28652 Page C1 Issued: 2017-11-28

CONCLUSION

Samples of the components covered by this Report have been found to comply
with the requirements covering the category and the components are found to
comply with UL’s applicable requirements. The description and test result in
this Report are only applicable to the sample(s) investigated by UL and does
not signify the product(s) described as being covered under UL’s Follow-Up
Service Program. When covered under UL’s Follow-Up Service Program, the
manufacturer is authorized to use the Recognized Marking on such products
which comply with UL’s Follow-Up Service Procedure and any other applicable
requirements of UL LLC. The Recognized Component Mark of UL LLC on the
product, or the Recognized Marking symbol on the product and the Recognized
Component Mark on the smallest unit container in which the product is
packaged, is the only method to identify products investigated by UL to
published requirements and manufactured under UL’s Recognition and Follow-Up
Service.

This Report is intended solely for the use of UL and the Applicant for
establishment of UL certification coverage of the product under UL’s Follow-
Up Service. Any use of the Report other than to indicate that the sample(s)
of the product covered by the Report has been found to comply with UL’s
applicable requirements is not authorized and renders the Report null and
void. UL shall not incur any obligation or liability for any loss, expense,
or punitive damages, arising out of or in connection with the use or reliance
upon the contents of this Report to anyone other than the Applicant as
provided in the agreement between UL and Applicant. Any use or reference to
UL’s name or certification mark(s) by anyone other than the Applicant in
accordance with the agreement is prohibited without the express written
approval of UL. Any information and documentation involving UL Mark services
are provided on behalf of UL LLC or any authorized licensee of UL.

Report By: Reviewed By:

Paola Sanchez-Cruz Amanda H. Newsom


Engineering Associate Engineering Leader

You might also like