You are on page 1of 1

DATA

Description REMARKS
Model No. Vendor to Provide TM 960 WITH IP 65 PROTECTION, FULL SS BODY
Type ( Pit Less / Pit Type) Pit type PIT TYPE
Capacity 60 M. Ton 60 MT
Platform Size Required 12 Meter X 3 Meter 12 METER x 3 METER
Platform Structure Main Beam, Chequired Plates and Other strucrure supports Confirming to IS 2062 - Make : Jindal
Least Count/ Readability 10 KG ( Vendor to Confirm ) 10 KG
Location Dahej
Indicator Digital ( Vendor to Provide Details) DIGITAL
Model Vendor to Provide TM 960
Display Flame Proof ( Display Details Vendor to Provide details) with SS COVE FLAME PROOF WITH SS COVER
Sensitivity Vendor to Provide 3 ±0.015 mV/V -
Resolution Vendor to Provide 10 KG -
Display Resolution Vendor to Provide 1 IN 200000 -
Non Linearity Vendor to Provide ±0.03 % of FS -
Load Cell Supply Vendor to Provide 10 Volts AC or DC -
Zero Tracking Required <0.02% of load cell Out Put -
Stability Band Required ±1 % of FS -
Filters Vendor to Provide if Required -
Weight Data To Computer Or Printer TO COMPUTER OR PRINTER -
Calibration Point Vendor to Provide -
Serial Output RS 232 /Ethernet/ RS 485 Available RS232, RS 485, ETHERNET -
Power Supply Available 230 V AC 230 V AC, 50 HZ - Single Phase -
Operating Temperature Range 0 TO 50 Deg. C. -10 to 60 degc -
Enclosure MS Powder Coated ( With SS Cover ) - Vendor to Confirm SS COVER -
Load Cell Details -
Make and Model number Vendor to Provide Double Ended Shear Beam Loadcell, -
MAKE : "Essae"
Type Analog ( Atex Approved) Analog Type (ATEX APPROVED) -
Design Capacity of each load cell, Vendor to Provide DSEB Type, 40 KLB -
Allowable over-load on each load ce Vendor to Provide 300 % of Rated Capacity -
- Safe Vendor to Provide 150 % of Rated Capacity -
- Impact or Ultimate Vendor to Provide -
Rated Output Sensitivity Vendor to Provide 3 ±0.015 mV/V -
Protection provided for dust, water,Required - vendor to provide details IP68 -
Input Resistance Vendor to Provide 770±3 Ohm -
Output resistance Vendor to Provide 700±5 Ohm -
Insulation Resistance Vendor to Provide ≥ 5000 Mega Ohms. -
Non- Repeatability Vendor to Provide ±0.02 % of FS -
Non-linearity, % RO Vendor to Provide ±0.03 % of FS -
Hysteresis, % RO Vendor to Provide ±0.03 % of FS -
Creep 30 Min. % RO Vendor to Provide Max 0.02% of FSO -
Zero balance % RO Vendor to Provide ±1 % of FS -
Recommended Voltage Vendor to Provide 10 Volts AC or DC -
Maximum Excitation Voltage Vendor to Provide 10 Volts AC or DC -
Temperature compensation range,Vendor to Provide -10 to 65 deg c -
Operating Temperature Limits, degVendor to Provide -10 to 60 deg c -
Protection Class Vendor to Provide IP68 -
Capacity Vendor to Provide 40 KLB -
MOC SS Electroless Nickel Plated Alloy steel -
Qty. Vendor to Provide 8 No's -
Junction Box Vendor to Provide IP 66/67 enclosure, MOC- SS -
OPTIONAL ACCESSORIES -
CAST IRON TEST WEIGHT 1000Required 1 TON REQUIRED -
Spares Required -
1 LOADCELL, 1 DIGITAL INDICATOR AND
JUNCTION BOX REQUIRE FOR SPARE

Sump & Manhole Details of Sump for Water Logging removal & Manhole for Maintenance - Req -
SCOPE
Supplier
Supervision of Installation & CommRequired EDPL SCOPE -
Government Weights & Measures Required EDPL SCOPE -
Foundation Kit for load cell Required CUSTOMER SCOPE -
Standard software Required ( Vendor to provide complete details of their software ) EDPL SCOPE -
Documents All Test Certificates, Operating & Maintenance Manual, Stamping Certificates EDPL PROVIDE -
Customer -
Computer, Printer & UPS Vendor to Provide Details DETAIL MENTIONED IN OFFER -
Power Supply Vendor to Provide Details 230V AC SINGLE PHASE, 50 HZ -
Earthing Supply Vendor to Provide Details 0 VOLT -
Operating Cabinet Client Want to Put Portable Cabinet - Vendor to Confirm or Provide Details DROWING PROVIDE BY EDPL -
Civil Work of Foundation Vendor to Provide Details ( GA and Foundation Drawings ) -
GA & CIVIL DRAWING PROVIDE BY EDPL

Any Assist for Erection ( Like Un Vendor to Provide Details -


* : VENDOR TO PROVIDE