www.vishay.com
Vishay BCcomponents
Aluminum Electrolytic Capacitors
SMD (Chip), High Temperature, Low Impedance
FEATURES
• Extended useful life: up to 6000 h at 125 °C
• Polarized aluminum electrolytic capacitors,
non-solid electrolyte, self healing
• SMD-version with base plate, lead (Pb)-free
reflow solderable
• Charge and discharge proof, no peak current limitation
• Advanced temperature reflow soldering according to
140 CRH lower Z 146 CTI
125 °C 125 °C JEDEC® J-STD-020
higher IR
• Vibration proof, 4-pin version and 6-pin version
lower Z
• AEC-Q200 qualified
150 CRZ • High reliability
105 °C
• Low ESR
Fig. 1
• Material categorization: for definitions of compliance
please see www.vishay.com/doc?99912
QUICK REFERENCE DATA
DESCRIPTION VALUE APPLICATIONS
Nominal case sizes 8 x 8 x 10
• SMD technology, for high temperature reflow soldering
(L x W x H in mm) to 18 x 18 x 21 • Industrial and professional applications
Rated capacitance range, CR 10 μF to 4700 μF • Automotive, general industrial, telecom
Tolerance on CR ± 20 % • Smoothing, filtering, buffering
Rated voltage range, UR 16 V to 100 V
MARKING
Category temperature range -55 °C to +125 °C
• Rated capacitance (in μF)
Endurance test at 125 °C 1000 h to 5000 h
• Rated voltage (in V)
Useful life at 125 °C 1500 h to 6000 h
• Date code, in accordance with IEC 60062
Useful life at 40 °C
150 000 h to 400 000 h • Black mark or “-” sign indicating the cathode (the anode is
1.8 x lR applied
identified by bevelled edges)
Shelf life at 0 V, 125 °C 1000 h
• Code indicating group number (T)
Based on sectional
IEC 60384-18 / CECC 32300
specification
PACKAGING
Climatic category IEC 60068 55 / 125 / 56
Supplied in blister tape on reel
SELECTION CHART FOR CR, UR, AND RELEVANT NOMINAL CASE SIZES (L x W x H in mm)
CR UR (V)
(μF) 16 25 35 50 63 80 100
10 10 x 10 x 10 10 x 10 x 10
22 10 x 10 x 10 10 x 10 x 10 10 x 10 x 10
33 8 x 8 x 10 10 x 10 x 10 10 x 10 x 10 10 x 10 x 12
47 10 x 10 x 10 10 x 10 x 10 10 x 10 x 10 10 x 10 x 12 10 x 10 x 12
68 10 x 10 x 10 10 x 10 x 10 10 x 10 x 12 12.5 x 12.5 x 13
10 x 10 x 10 10 x 10 x 12
100 8 x 8 x 10 10 x 10 x 10 12.5 x 12.5 x 13 12.5 x 12.5 x 16
10 x 10 x 12 12.5 x 12.5 x 13
150 10 x 10 x 10 10 x 10 x 12 12.5 x 12.5 x 13 12.5 x 12.5 x 16 16 x 16 x 16
16 x 16 x 21
220 8 x 8 x 10 10 x 10 x 10 10 x 10 x 12 12.5 x 12.5 x 13 12.5 x 12.5 x 16 16 x 16 x 16
18 x 18 x 16
16 x 16 x 21
330 10 x 10 x 10 10 x 10 x 12 12.5 x 12.5 x 13 12.5 x 12.5 x 16 16 x 16 x 16 18 x 18 x 21
18 x 18 x 16
470 10 x 10 x 12 12.5 x 12.5 x 13 12.5 x 12.5 x 16 16 x 16 x 16 16 x 16 x 16 18 x 18 x 21 -
680 12.5 x 12.5 x 13 12.5 x 12.5 x 16 16 x 16 x 16 16 x 16 x 16 18 x 18 x 16 - -
820 16 x 16 x 21 - -
16 x 16 x 21 - -
1000 12.5 x 12.5 x 16 16 x 16 x 16 16 x 16 x 16 18 x 18 x 21
18 x 18 x 16 - -
1200 18 x 18 x 16 18 x 18 x 21 - - -
1500 16 x 16 x 16 16 x 16 x 16 16 x 16 x 21 - - - -
1800 18 x 18 x 21 - - - -
16 x 16 x 21 - - - - -
2200 16 x 16 x 16
18 x 18 x 16 - - - - -
2700 18 x 18 x 21 - - - - -
16 x 16 x 21 - - - - - -
3300
18 x 18 x 16 - - - - - -
3900 18 x 18 x 21 - - - - - -
4700 18 x 18 x 21 - - - - - -
L4-H
2200u
25V
3R-H
1000u
35V
D D
D
12.5 x 12.5 x 13 1213 12.9 12.9 14.0 12.5 1.3 3.6 14.9 2.6
12.5 x 12.5 x 16 1216 12.9 12.9 16.5 12.5 1.3 3.6 14.9 2.8
Table 2
Note
• Detailed tape dimensions see section “PACKAGING”
e
a c a
d
b b f
b
d
a c a a c a
Table 3
T (°C)
TPeak
230
t4
217
t3
200
190
t2
150
t1
25
time (s)
Table 4
Ramp up rate from 200 °C to TPeak 0.5 K/s to 3 K/s 0.5 K/s to 3 K/s 0.5 K/s to 3 K/s
Ramp-down rate from TLiquidus 3 K/s to 6 K/s 3 K/s to 6 K/s 3 K/s to 6 K/s
Notes
• Temperature measuring point on top of the case and on terminals.
• Max. 2 runs with pause of min. 30 min in between.
Table 5
Table 6
1.0 1
2
0.9
1 Curve 1: 16 V
Curve 2: 63 V
0.8 0.1
-60 -40 -20 0 20 40 60 80 100 120 -60 -40 -20 0 20 40 60 80 100 120 140
C0 = Capacitance at 20 °C, 100 Hz Tamb (°C) tan δ0 = Typical tan δ at 20 °C, 100 Hz Tamb (°C)
Fig. 5 - Typical multiplier of capacitance as a function Fig. 6 - Typical multiplier of dissipation factor (tan )
of ambient temperature as a function of ambient temperature
1 1 1
2
3
4
0.1 5
6
0.1 0.01
10 102 103 104 f (Hz) 105 10 100 1000 10 000 100 000
ESR0 = typical ESR at 20 °C, 100 Hz Tamb = 20 °C f (Hz)
Fig. 7 - Typical multiplier of ESR as a function of frequency Fig. 8 - Typical impedance as a function of frequency
IMPEDANCE (Z)
1000 10 000
Z Curve 1: 68-63-1010 Z Curve 1: 10-100-1010
(Ω) Curve 2: 100-63-1012 (Ω) Curve 2: 47-100-1012
Curve 3: 150-63-1213
100 1000 Curve 3: 68-100-1213
Curve 4: 220-63-1216
Curve 5: 470-63-1616 Curve 4 : 100-100-1216
Curve 6: 1000-63-1821 Curve 5 : 150-100-1616
1 Curve 6 : 220-100-1621
10 100
Curve 7 : 330-100-1821
1
2 2
1 3 3
10 4
4
5
5 6
6 7
0.1 1
0.01 0.1
10 100 1000 10 000 100 000 10 100 1000 10 000 100 000
f (Hz) f (Hz)
Fig. 9 - Typical impedance as a function of frequency Fig. 10 - Typical impedance as a function of frequency
MBC242
I A 4.3
IR
4.2
4.1
4.0
3.9
3.8
3.7
3.6
3.5
3.4
3.3
3.2
3.1
3.0
Lifetime multiplier
2.8
1.
0
2.6
1.
5
2.
0
2.4
3.
0
4.
0
2.2
6.
0
8.
2.0
0
(1)
Useful life at 125 °C and IR applied;
30
1.6
see Table 7
60
1.4
10
1.2
0
(1)
20
1.0
0
0.8
40
0.5
0
0.0
40 50 60 70 80 90 100 110 120 130 Tamb (°C)
Fig. 11 - Multiplier of useful life as a function of ambient temperature and ripple current load
Table 9
C/C: ± 30 %
tan 3 x spec. limit
CECC 30301, Tamb = 125 °C; UR and IR applied;
Useful life IL2 spec. limit
subclause 1.8.1 for test duration see Table 7
no short or open circuit
total failure percentage: 1 %
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of
typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding
statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a
particular product with the properties described in the product specification is suitable for use in a particular application.
Parameters provided in datasheets and / or specifications may vary in different applications and performance may vary over
time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk.
Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for
such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document
or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.