Why theoretical concrete quantity is more than actual poured qty if there is mass concrete or by
mechanical concrete
 Amit Baluni ·  Aug 26, 2020

A
Aug 26, 2020  #1
Sir, Why theoretical concrete quantity is more than actual poured qty if there is mass concrete or by mechanical concrete ??

Amit Baluni
Apprentice

 Navi-Mum…

Sort by date Sort by votes

V
Aug 27, 2020  #2 
Amit Baluni said:  0
Sir, Why theoretical concrete quantity is more than actual poured qty if there is mass concrete or by mechanical concrete ?? 
V R Suresh Ur theoretical concrete quantity never accounts for volume reduction of reinforcement in case of mass concrete & wastage
Simha during pouring.
Junior Member
 Bengaluru HockeyPuck

A
Aug 27, 2020  #3 
V R Suresh Simha said:  0
Ur theoretical concrete quantity never accounts for volume reduction of reinforcement in case of mass concrete & wastage during 
pouring.
Amit Baluni
Apprentice thanks sir for your reply but can you explain more points which also effect.

 Navi-Mum…

R
Aug 27, 2020  #4 
1. Reinforcement Volume - 1 to 1.5% (Some time more than this in critical foundations)- Reference- My Experience
2. Air Content- up to 1%- Reference- IS 10262 Table 3 0

This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
rahuledu
By continuing to use this site, you are consenting to our use of cookies.
 Accept Learn more…

https://civil4m.com/threads/why-theoretical-concrete-quantity-is-more-than-actual-poured-qty-if-there-is-mass-concrete-or-by-mechanical-concrete.9406/ 1/4
3/28/2021 Why theoretical concrete quantity is more than actual poured qty if there is mass concrete or by mechanical concrete | Civil4M
 Prime CE

 Etah, Uttar …

Aug 30, 2020  #5 


Factors that affects the concrete quantity in practical application.
0
Yield of the concrete = it is like after mixing ingredients as per design, do am i getting volume of concrete equals to 1 cum or
is there any difference.

Dnyan
Deshmukh This volume gets affected due to change in source of the aggregates, if aggregates becomes lighter in density, your concrete
Staff member is going to give you more than a cum in volume for same mix design. it will further reduce the volume of the concrete in case
 Pune of aggregates received are heavier than one used for doing mix design.

Batching Error - The batching plant if looses its calibration on its weight scales, it will impact severely on a produce concrete
like it will overdose the aggregates in a mix which will tend to increase the volume of 1 cum of concrete with same cement
content.

Error in Theoretical Concrete Quantity Calculations - This will also lead to difference between poured and theoretical
quantity either on plus or on minus side.

Pouring Error - In case of the mass concrete pouring less by few mm or few cm could make a huge difference in the concrete
quantity which in most of the cases results in consumption of concrete by less than required amount as per theoretical value.
shenbagaraja pandian and rahuledu

A
Aug 31, 2020  #6 
thanks..
0

Amit Baluni
Apprentice

 Navi-Mum…

Sep 17, 2020  #7 


Dnyan Deshmukh said:  0
Factors that affects the concrete quantity in practical application. 
Sumathi Yield of the concrete = it is like after mixing ingredients as per design, do am i getting volume of concrete equals to 1 cum or is
chowthri there any difference.
Newbie
 Bangalore This volume gets affected due to change in source of the aggregates, if aggregates becomes lighter in density, your concrete is
going to give you more than a cum in volume for same mix Click to expand...
design. it will further reduce the volume of the concrete in case of

Sep 17, 2020  #8 


sorry if am wrong sir...density of aggregate or cement doesn't matter in the sense of concrete volume variation b/w Theoritical
vs actual i guess. It may correct during the output volume of concrete from batching plant. 0

Sumathi
chowthri
Newbie
 Bangalore

Sep 18, 2020  #9 


By stating density, I mean to say specific gravity in simplest way.
0
Specific gravity of the material do impact on the volume of the concrete produced, in case when the concrete production is
This site uses cookies
done bytoweight
help personalise
batching content,
process.tailor your experience and to keep you logged in if you register.

 By continuing to use this site, you are consenting to our use of cookies.
 Accept Learn more…

https://civil4m.com/threads/why-theoretical-concrete-quantity-is-more-than-actual-poured-qty-if-there-is-mass-concrete-or-by-mechanical-concrete.9406/ 2/4
3/28/2021 Why theoretical concrete quantity is more than actual poured qty if there is mass concrete or by mechanical concrete | Civil4M
Dnyan
Deshmukh At the time of concrete mix designing, the weights of the each aggregates are decided base on their specific gravity.
Staff member

 Pune Specific gravity is the ratio of per unit volume of material compared with same unit volume of water (stating it with unit of
kg/cum does not make any difference like, aggregate having specific gravity of 2.9, I could say aggregates weights 2900 kg
per cum in its purest form without any voids in it, but as its a ratio in mathematical calculations kg and cum get removed).

crush aggregates when taken as cum quantity, it will weight less due to presence of voids in it, if we compare it with same
aggregate / rock which is in size of 1m x 1m x 1m.

example - I have to put 750 kg of 20 mm aggregates in concrete. if its specific gravity becomes low due to higher porosity or
voids in it. the volume which it makes to same weight will get increase and will make my concrete more than a cum for same
mix design. same way if its specific gravity increases my volume will become less for same required weight of aggregate in
mix, this will result into less volume of concrete.

Heavy weight concrete is produced by using heavy aggregates where the volume of the concrete is same but weights of
aggregates are more.

so changes in specific gravity of aggregates do impact on the volume of concrete produced with it.
Mehboob

S
Oct 9, 2020  #10 
Hello Sir, Can you Please make a Share an Excel Sheet for Concrete Mix Designs for all Grades
I Could See only M10,M25 and M30 and that one is with Fly Ash and one is with Pure Cement. 0

So it would be helpful if you can share all grades



Sreevastatp M10, M20,M25,M30 Grades with Fly Ash
Newbie
 Hyderabad

Oct 10, 2020  #11 


For concrete mix design program in excel sheet
0
Concrete Mix Design Excel Program up to M85 Grade - Now do it in e…
Concrete Mix Design Excel Program As we know the concrete ingredients 
Dnyan properties are not same in all area, so the properties of ingredient affects the
mix design and a designed made at some place in KanyaKumari can not be
Deshmukh
used at Kashmir. So referring a design made by someone for his work at...
Staff member
civil4m.com
 Pune

For understanding and doing concrete mix designing.

Become Concrete Master - Concrete Mix Designing


Concrete is a material which is a basic for any project. I will be helping you
out by sharing my experience with all of you (You too can help me in
learning new tech's in this field by sharing your experience through doing
post on forum). After reading all posts you will be in position to say...
civil4m.com

You must log in or register to reply here.

Similar threads

A Is there any IS code where mentioned bend deduction while calculating cut length of a ring .... Replies: 1 Today at 9:39
Amit Baluni · Thursday at 7:13 PM Views: 39 AM
Dnyan
Deshmukh

red & white type stone in coarse aggregate good or bed for concrete work? Replies: 1 Today at 9:22
vala akshit mansukhbhai · Wednesday at 4:01 PM Views: 37 AM
This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register. Dnyan
 By continuing to use this site, you are consenting to our use of cookies.
 Accept Learn more…
Deshmukh

https://civil4m.com/threads/why-theoretical-concrete-quantity-is-more-than-actual-poured-qty-if-there-is-mass-concrete-or-by-mechanical-concrete.9406/ 3/4
3/28/2021 Why theoretical concrete quantity is more than actual poured qty if there is mass concrete or by mechanical concrete | Civil4M

T Can anyone share with me Excel spreadsheet for construction management. Please share. Replies: 1 Wednesday at
thanyani.nemangaka@gmail.com Views: 62 12:44 AM
thanyani.nemangaka@gmail. · Monday at 10:25 AM HockeyPuck

N Request for Method Statement of Mass concrete temperature testing using thermocouple. Replies: 5 Yesterday at S
Nawab M A · Mar 18, 2021 Views: 141 12:38 PM
Srinivasan G

redosing of admixture and water in ready mix concrete after 3 to 4 hours is safe or not? Replies: 2 Mar 16, 2021
vala akshit mansukhbhai · Mar 13, 2021 Views: 130 vala akshit
mansukhbhai

Share:       

Contact us Terms and rules Privacy policy Help  

Forum software by XenForo® © 2010-2021 XenForo Ltd. | Civil4M © 2017-2021 | Global Institute of Strategic Business Leaders PVT LTD |

This site uses cookies to help personalise content, tailor your experience and to keep you logged in if you register.
 By continuing to use this site, you are consenting to our use of cookies.
 Accept Learn more…

https://civil4m.com/threads/why-theoretical-concrete-quantity-is-more-than-actual-poured-qty-if-there-is-mass-concrete-or-by-mechanical-concrete.9406/ 4/4

You might also like