B RANGE FLAT ANCHORageS
INSTALLATION performances
The post-tensioning equipment is generally Approval static tests according to BS 4447 have been carried out on the anchorages
installed as follows: of the B range.
• Ducts and trumplates installation
They can be used with all classes of standard or super strands (T13, T13S, T15,
• Placement of tendons and anchorages T15S), in concrete structures. B range anchorages can be used on slabs with a
minimal thickness of 180 mm. The minimal concrete compressive strength at
The threading of the strands is carried out before
stressing shall be the following depending on the strand type :
concreting. When the concrete reaches a sufficient
resistance, the recess formwork is removed to allow
the assembly of the anchorage blocks and wedges. Strand type Minimal cylinder concrete Minimal cube concrete
compressive strength compressive strength
• Tensioning T13 S 20 MPa 25 MPa
The stressing of the tendons is carried out strand T15 21 MPa 26 MPa
by strand using a monostrand jack with a specific T15 S 23 MPa 28 MPa
adaptation allowing the correct alignment of the
jack and a mechanical wedges adjustment.
Where the tensioning of anchorages is not possible Bursting reinforcement
from slab edge a specific adaptation with a curved
The recommended bursting reinforcement is described in the sketch below.
nose shall be used.