Spark  10M 

IMAGING MULTIMODE READER


02 SPARK 10M BROCHURE

I NCU
IS B
YS

AT
AL

I
AN

ON
P RO
ON

TE
TI

CT
EC IO
DET N

Engineered with cellular assays in mind .


Capabilities At Tecan, we understand the demands of cell-based
Cell counting and viability analysis applications and the challenges they pose every day.
Automated cell imaging You need a plate reader that ensures not only ideal
Automated cell confluence cellular conditions, but also excellent assay results. And
Cell incubation
that’s exactly what you get with the Spark 10M, which
Evaporation protection
boasts a range of features and capabilities for specialized
Automated microplate lid handling
activities such as fast cell counting and evaluation of cell
Reagent dispensing with heating
and stirring
proliferation by confluence analysis.
Te-Cool™ cooling

Absorbance

DNA quantification

NA labeling efficiency

Cuvette port

Fluorescence intensity

Time-resolved fluorescence (TRF)

Fluorescence resonance
energy transfer (FRET) With a single click, SparkControl™ gives you fast, accurate cell counts for live/dead analysis

Time-resolved fluorescence
Label-free cell counting and fast viability analysis
resonance energy transfer (TR-FRET)
With its built-in cell counter, the Spark 10M can analyze a broad range of
Fluorescence polarization
cell sizes and types, providing fully automated label-free cell counting and
Luminescence (flash and glow) analysis in less than 30 seconds.
Alpha Technology · Accurate, reproducible cell counting, with flexible area selection for
Luminescence scanning greater sensitivity
· One-click analysis providing cell number, size distribution and viability
Multi-color luminescence
· Export cell images for visual confirmation
(BRET 1, BRET2™, BRET 3, Chroma-Glo™)
· High-precision cell counting, even at low concentrations
SparkControl™ software
· Automated replicate processing for multiple samples in disposable Cell Chips™
SparkControl Magellan™

QC tools (IQ/OQ services)

Connect™ microplate stacker

Tecan’s innovative Cell Chips minimize Spark 10M lets you generate automatic
T RANSCREENER
R

T RANSCREENER
R

T RANSCREENER
R
sample preparation, offering greater mean value calculations of samples in
Red FI validated
application flexibility and opening up multiple disposable Cell Chips.
Far Red FP validated Red TR-FRET validated

www.bellbrooklabs.com www.bellbrooklabs.com www.bellbrooklabs.com


new cell counting possibilities.
SPARK 10M BROCHURE 03

No matter what your application, the Spark 10M multimode reader delivers the
ideal combination of advanced capabilities and exceptional ease of use, enhancing
productivity with a series of unique features and benefits.
R = 0,98957
Automated cell imaging and confluence measurements 100
90

It is necessary to normalize results over several wells across a 80


70

Confluence %
microplate to have confidence in your cell-based assay results. 60 10% 30%
50
The problem is that you don’t know how many cells have adhered 40 70% 90%
to the bottom of the microplate, or even grown, over a certain 30
20
period of time. It is now possible to automatically measure cell 10

confluence and image cells in the well of a microplate. This allows 0


0 0,1 0,2 0,3 0,4 0,5 0,6

the system to automatically inject a compound or measure a GFP BCA OD

The growth of HeLa cells at various confluence


signal once a user-defined cell confluence is reached, providing
levels and the corresponding increase of
more reliable results. protein content measured using a BCA assay
protocol.

Maintain stable culture conditions and improve cell growth 600 5000 cells / medium with FCS

An integrated Gas Control Module (GCM™) features two independent 500 ■ Spark
■ no GCM
gas inlets that allow automated control of CO2 and O2 concentrations 400

inside the reader chamber for:

cell growth [%]


300
· Stable long-term cell culture environments
200
· Improved cell viability and extended experiment times without adversely
affecting results
100

· Optimization of gas levels and mixtures with independent regulation 0


0 10 20 30 40 50 60

of CO2 and O2 concentrations time [h]

· Software-controlled, automated adjustments for real-time modulation Comparison of cell proliferation in the
of gas concentrations during a run Spark 10M reader with integrated GCM
and a standard microplate reader.

Evaporation protection to enhance cell viability


Built-in evaporation protection enhances live cell kinetic assays for better
reproducibility and more reliable data. A patent-pending Humidity Cassette
reduces evaporation in standard microplates, minimizing edge effects and
enabling long-term live kinetic studies without the need to switch to dedicated
and costly microplate types; simply use your current, validated plates.

Minimize evaporation and contamination with automated microplate


lid handling
The integrated microplate Lid Lifter™ simplifies applications such as
absorbance and luminescence assays by automatically removing the lid
for measurements. It gives you the flexibility to perform automated
reagent additions during an experiment without manual intervention. This
patented feature optimizes CO2/O2 exchange and minimizes evaporation,
allowing walkaway automation for experiments such as long-term kinetic
assays.

Reagent dispenser with heating and stirring enhances application flexibility


Integrated injectors help to generate consistent data by eliminating
precipitation and salt formation. Independent heating and stirring capabilities
increase the reliability and reproducibility of compound handling, as well as
enabling automated dispensing of viable cells.
04 SPARK 10M BROCHURE

Designed for flexibility. Engineered for performance.

Broaden your format flexibility


Spark 10M reads cuvettes, the low-volume NanoQuant Plate™, disposable Cell Chips, Roboflask ® and is
also compatible with all standard ANSI/SLAS microplate formats up to 384 wells.

Absorption

Absorbance – get a full spectrum quickly, with ultra-fast


4,5

3,5
absorbance measurements
3 Spark 10M’s patent-pending High-Speed Monochromator (HSM) delivers
complete spectra – from 200–1,000 nm – in just 5 seconds. These ultra-
OD

2,5

2 fast measurements offer the speed of a diode array with the precision and
1,5 flexibility of a monochromator for wide-ranging and detailed spectra.
1

0,5

0
Fast absorbance scan of a didymium filter
200 300 400 500 600 700 800 900 1000
Wavelength [nm] from 200–1,000 nm with 1 nm resolution

Ultra-fast DNA quantification


With its High-Speed Monochromator, the Spark 10M provides unparalleled
wavelength accuracy for DNA and protein quantification:
· Improved performance and increased dynamic range from UV to NIR
· Full absorbance spectrum data from 200–1,000 nm in less than 5 seconds
· High accuracy, especially in the deep UV range (230–260 nm), for complete
confidence in your DNA sample QC
· An OD range from 0–4 ensures good linearity, requiring fewer dilutions and
less manual pipetting

Fluorescence – Fusion Optics deliver the best of both worlds


Emission Excitation
Spark 10M is the first instrument to offer independent, user-selectable
  filters and monochromators on both the excitation AND emission sides for
  any measurement. You no longer have to choose between sensitivity OR
flexibility — you can now have both. Every well. Every assay. Every time.
Monochromator Filter
From both the top and bottom of your sample.
®
Fusion Optics:
provides easy access to
flexibility and sensitivity;
always freely selectable in
the SparkControl software.
SPARK 10M BROCHURE 05

Unparalleled flexibility for luminescence


Optimize your assays with Spark 10M’s multi-color luminescence option. The
system offers an excellent dynamic range of 10 9 using up to 3 OD attenuation,
with 40 user-selectable filters to provide unprecedented freedom for virtually
any luminescence measurements, including BRET 1,2,3 and Chroma-Glo.

Using a unique filter-based technique, the desired detection wavelength


for multi-color luminescence measurements can be selected with only a
few mouse clicks.
Enhance your assay performance and
flexibility with multi-color luminescence
and luminescence scanning.

High performance Alpha Technology 5.00


5,00 Detection
Detection Limit
Limit

Alpha Technology comprises AlphaScreen®, AphaLISA® and AlphaPlex®, and 4.50


4,50

4.00
is a luminescent bead-based assay technology designed for the measurement
4,00
3.62
3,62

[ng/ml Omnibeads]
3.50
3,50

of biological interactions. Spark 10M is equipped with a high performance laser

[ng/mL Omnibeads]
3.00
3,00

light source for excitation, and an IR sensor for well-by-well temperature 2.50
2,50

correction. This results in better sensitivity, uniformity and linearity for 2.00
2,00
1,58
1.58
your Alpha assays. SparkControl also offers preselected filter settings for 1.50
1,50

AlphaScreen, AlphaLISA and AlphaPlex, as well as user-selectable filter 1.00


1,00

0.50
settings for future Alpha Technology applications.
0,50

0.00
0,00
Spark
Spark Sparktemp.
Spark temp. corr.
corr.

2.5

2
Ambient

% CV
1.5
Improved temperature control with Te-Cool 28 °C
1
A stable temperature is a prerequisite for getting reliable results. Whether 0.5

you read enzymatic reactions such as luciferase assays, run temperature- 0


0 5 10 15 20
dependent Alpha assays, or study kinetic assays of living organisms, you min

need precise, controllable cooling. Now, for the first time, Te-Cool lets you Assays run at equilibrated ambient temperatures
keep your assay stable at a specific temperature for long periods. lead to better sensitivity. The CV is shown for
absorbance readings taken at 570 nm every 5
min with Spark set to ambient temperature with
For most readers, the specified minimum temperature inside a plate reader is Te-Cool vs. a higher temperature set at 28 oC.
defined as a few degrees above ambient. This can vary significantly depending
on the time of year and location, and so will your results. Temperature gradients 1.400 Ambient +8 °C CV=14,6

1.300 Ambient +4 °C
can also occur across a microplate with many readers, leading to poor precision 1.200 Ambient
Luminescence [RLU]

and variations in your results. 1.100


1.000
CV=7,7
900
A key benefit of Spark’s Te-Cool module is the ability to measure your assay 800

at ambient temperatures, ensuring more stable readings without even 700


600 CV=0,4
needing to know the exact temperature – the software takes care of 500
everything, keeping the measurement chamber at ambient temperature. 400
0 1 2 3 4 5 6
Time [min]

Enzymatic assays are temperature sensitive.


A luminescence assay was measured kinetically
over a time course of 10 min. Best results
with lowest CV were obtained when setting
Connect microplate stacker for Spark 10M Spark 10M at a constant ambient temperature
with Te-Cool.
The Connect is a versatile microplate stacker designed to allow walkaway
batch processing for up to 50 microplates per run. It interfaces directly with
SparkControl Magellan reader software for easy operation, offering increased
throughput for a wide range of applications in genomics, proteomics and drug
discovery.

Connect stacker highlights include:


· Designed for reliable operation and ease of use
· Dark cover to protect light-sensitive well contents
· Allows manual operation of single plates
· Barcode scanner option which can read either short side of the plate
· C hoice of 30- or 50-plate column cassettes to suit your
throughput requirements
06 SPARK 10M BROCHURE

Standard OR

Fast, simple instrument operation is at your fingertips Optimized fluorescence bottom-


reading with Tecan’s unique Optimal
with SparkControl’s touch-optimized, intuitive interface.
Read (OR) function. OR ensures
Engineered to simplify your daily laboratory tasks, very low CVs by performing multiple
SparkControl offers: measurements on spatially separated
spots arrayed across each well.

Substrate

FIRST
MEASUREMENT

Substrate

SECOND
MEASUREMENT

High definition well scans provide SparkControl makes it easy to adjust Get instant access to applications
a complete picture of the cell parameters during a run, including and enjoy easy operation with
population in each well for more environmental conditions such as SparkControl’s one-click, workflow-
accurate signals, even with inhomo– temperature (even below ambient) based interface. The software makes
geneous cell layers. The software and the CO2 and O2 levels inside it easy and intuitive to translate your
also provides a qualitative image of the reader. workflow into a saved protocol that
the cell distribution. can be run or edited at any time.

App App App


Cell Cell Nucleic Acid
Counting Viability Quantitation

App App
Cuvette Labelleling
Efficiency Automated z-focus adjustment Simplify the workflow for cell-based
enhances the sensitivity of top- assays with the cell confluence
reading fluorescence intensity and feature. Increase confidence for
One-click applications streamline fluorescence polarization modes, cytotoxicity, cell proliferation, and
your workflows, getting you from significantly improving the quality protein expression assays by, for
sample to results faster than ever of results. No matter what your example, automatically controlling
before. plate volume, sample volume or well the addition of compounds at a
shape, this unique feature makes user-defined cell confluence.
it easy to set up your reader for
optimum performance with varying
assay parameters.
SPARK 10M BROCHURE 07

Extended
dynamic range

Detect even very low signals with the SparkControl Magellan is a data analysis package
Spark 10M’s extended dynamic range.
providing powerful data reduction tools for numerous
This function automatically adjusts the
gain settings during a measurement detection modes.
run, allowing the detection of very
low signals without compromising on SparkControl Magellan offers The software provides a suite of
sensitivity. All results are automatically users an array of tools designed to sophisticated functions including:
correlated and displayed within one enhance functionality, simplicity · Full qualitative and quantitative
single data set. and security. EIA analysis
· I deal for microplate-based · A ll major curve fittings, including
applications such as ELISAs, point-­to-­p oint, linear regression,
end-point assays, kinetic assays, non-linear regression, polynomial,
ratiometric measurements, cubic spline, Akima, logit-log,
multi-­label measurements and four- and five-parameter fits
3D scanning · C onvenient handling of dilution
Kinetic assay · Rapidly perform everything from series and ICx calculations
data reduction and curve fitting · G eneral data import and export
protection
to the calculation of kinetic options, as well as automated
parameters, such as Michaelis- import of sample ID lists.
Safeguard your kinetic assays using Menten constants · K inetic data analysis with
automated gain regulation to avoid · V ideo tutorials and example files calculation of slopes, onsets
fluorescence measurements running simplify operation and enzyme kinetics
into saturation. Measurements with · Plate definition editor allows · S pectral calculations to provide
different gain settings are then creation of customized plate rapid background correction,
automatically correlated, allowing geometry files curve smoothing, wavelength
evaluation of the entire dataset. selection, peak identification and
3D scanning

SparkControl Magellan makes it easy to Designed to simplify the user experience,


perform complete kinetic data analyses SparkControl Magellan conveniently
including the calculation of slopes, onsets handles all dilution series and ICx
and enzyme kinetics. calculations.

SparkControl Magellan Tracker offers all the functionalities necessary for


compliance with FDA regulation 21 CFR part 11 for electronic records and
signatures, while still providing all the advantages of SparkControl Magellan
Standard.

7
Typical performance values*
Absorbance AlphaScreen
Light source Dedicated Limit of detection ≤100 amol/well bio-LCK-P6; 20 µl
xenon flash lamp ≤2.5 ng/ml Omnibeads7; 20 µl
Spectral range 200–1,000 nm Uniformity ≤3.0%
OD range 0–4 OD Z´value ≥0.9
Scan speed (200–1,000 nm) ≤5 sec Fastest read times8 ≤2 min (384-well plate)
Wavelength accuracy <0.3 nm ≤1 min (96-well plate)
Wavelength reproducibility ≤0.3 nm Cell counting
Wavelength ratio accuracy (260/230) <0.08 Size range 4–90 µm
Wavelength ratio accuracy (260/280) <0.07 Counting accuracy +/–10% (10–30 µm)
Precision @ 260 nm <0.2% Counting reproducibility <10% (10–30 µm)
Accuracy @ 260 nm <0.5% Cell concentration 1x104–1x107 cells/ml
Limit of detection (nucleic acids) <1 ng/µl Imaging speed inc. data reduction <30 sec/sample
Number of samples/run ≤8 samples
Fluorescence intensity
Light source Dedicated xenon flash lamp Automated cell imaging
Spectral range Ex: 230–900 nm; Em: 280–900 nm Illumination High power LED
Wavelength accuracy Ex: <1 nm; Em: <2 nm Image Bright-field
Wavelength reproducibility <1 nm Objective 4x
Optical mirrors 50%; 510 nm dichroic Autofocus Laser based
Well scanning Up to 100 x 100 data points Optical resolution 1.3 µm/pixel
Limit of detection1
Gas Control Module
Fusion F/F – top ≤0.25 pM (≤25 amol/well; 100 µl)
Adjustable concentration range – CO2 0.04–10% (vol.)
Fusion M/F or F/M – top ≤0.35 pM (≤35 amol/well; 100 µl)
Adjustable concentration range – O2 0.1–21% (vol.)
Fusion M/M – top ≤0.50 pM (≤50 amol/well; 100 µl)
Concentration accuracy – CO2 <1% (vol.)
Fusion F/F – bottom ≤2.5 pM (≤0.5 fmol/well; 200 µl)
Concentration accuracy – O2 <0.5% (vol.)
Fusion M/F or F/M – bottom ≤3.5 pM (≤0.7 fmol/well; 200 µl)
Fusion M/M – bottom ≤4.0 pM (≤0.8 fmol/well; 200 µl) Reagent injectors
Syringe sizes 0.5 ml; 1 ml
FP (fluorescence polarization)2
Pump speed 100–300 µl/sec
Spectral range 300–850 nm
Injection volume 5–1,000 µl; step size: 1 µl
Precision – Fusion F/F ≤1.5 mP
Dead volume ≤100 µl
Precision – Fusion F/M ≤2.5 mP
Injection accuracy and precision ≤0.5% at 450 µl
Precision – Fusion M/F ≤2.5 mP
Precision – Fusion M/M ≤3.0 mP Temperature control Ambient +4 °C (up to 42 °C)
Uniformity <0.5 °C
TRF (time-resolved fluorescence) 3

Limit of detection – Fusion F/F ≤40 fM (≤4.0 amol/well; 100 µl) Te-Cool cooling module
Limit of detection – Fusion F/M ≤65 fM (≤6.5 amol/well; 100 µl) Temperature range +18–42 °C
Limit of detection – Fusion M/F ≤65 fM (≤6.5 amol/well; 100 µl)
Shaking
Limit of detection – Fusion M/M ≤100 fM (≤10 amol/well; 100 µl)
Linear, orbital, double-orbital;
Luminescence variable amplitudes and frequencies
Spectral range 370–700 nm
Plate formats
Luminescence (glow)
Up to 384 wells; NanoQuant Plate; Cell Chip;
Limit of detection4 ≤9 pM (≤225 amol/well; 25 µl)
Cuvettes; Roboflask
Luminescence (flash)
Limit of detection5 ≤218 fM (≤12 amol/well; 55 µl) Fastest read time
Dynamic range >9 orders of magnitude 96-well plate (FI) ≤13 sec
Multi-color luminescence 38 spectral filters; 384-well plate (FI) ≤30 sec
OD1, OD2, OD3 attenuation filters

* Specifications are subject to change. Performance values represent the average observed factory tested values.
For product specifications refer to operators manual.
1) D
 etection limit for fluorescein; Fusion Optics: F-Filter; M-Monochromator; 5) Detection limit for ATP (ENLITEN® Kit)
2) FP detection limit @ 1 nM fluorescein 6) (PE# 6760620; P-Tyr-100 assay kit)
3) Detection limit for europium 7) (PE# 6760626D; Omnibeads)
4) Detection limit for ATP (144-041 ATP detection kit SL [BioTherma]) 8) Including temperature correction

Australia +61 3 9647 4100 Austria +43 62 46 89 33 Belgium +32 15 42 13 19 China +86 21 220 63 206 Denmark +45 70 23 44 50 France +33 4 72 76 04 80
Germany +49 79 51 94 170 Italy +39 02 92 44 790 Japan +81 44 556 73 11 Netherlands +31 18 34 48 17 4 Singapore +65 644 41 886 Spain +34 93 490 01 74
Sweden +46 8 750 39 40 Switzerland +41 44 922 89 22 UK +44 118 9300 300 USA +1 919 361 5200 Other countries +43 62 46 89 33
398454 V3.0 01-2016, 30110115

Tecan Group Ltd. makes every effort to include accurate and up-to-date information within this publication, however, it is possible that omissions or errors
might have occurred. Tecan Group Ltd. cannot, therefore, make any representations or warranties, expressed or implied, as to the accuracy or completeness
of the information provided in this publication. Changes in this publication can be made at any time without notice. All mentioned trademarks are protected
by law. In general, the trademarks and designs referenced herein are trademarks, or registered trademarks, of Tecan Group Ltd., Männedorf, Switzerland. A
complete list may be found at http://www.tecan.com/trademarks. Product names and company names that are not contained in the list but are noted herein
may be the trademarks of their respective owners. For technical details and detailed procedures of the specifications provided in this document please
contact your Tecan representative.

Spark multimode reader is for research use only.

Tecan is in major countries a registered trademark of Tecan Group Ltd., Männedorf, Switzerland.
© 2016 Tecan Trading AG, Switzerland, all rights reserved.

www.tecan.com