Spark 10M: Imaging Multimode Reader
Spark 10M: Imaging Multimode Reader
I NCU
IS B
YS
AT
AL
I
AN
ON
P RO
ON
TE
TI
CT
EC IO
DET N
Absorbance
DNA quantification
NA labeling efficiency
Cuvette port
Fluorescence intensity
Fluorescence resonance
energy transfer (FRET) With a single click, SparkControl™ gives you fast, accurate cell counts for live/dead analysis
Time-resolved fluorescence
Label-free cell counting and fast viability analysis
resonance energy transfer (TR-FRET)
With its built-in cell counter, the Spark 10M can analyze a broad range of
Fluorescence polarization
cell sizes and types, providing fully automated label-free cell counting and
Luminescence (flash and glow) analysis in less than 30 seconds.
Alpha Technology · Accurate, reproducible cell counting, with flexible area selection for
Luminescence scanning greater sensitivity
· One-click analysis providing cell number, size distribution and viability
Multi-color luminescence
· Export cell images for visual confirmation
(BRET 1, BRET2™, BRET 3, Chroma-Glo™)
· High-precision cell counting, even at low concentrations
SparkControl™ software
· Automated replicate processing for multiple samples in disposable Cell Chips™
SparkControl Magellan™
Tecan’s innovative Cell Chips minimize Spark 10M lets you generate automatic
T RANSCREENER
R
T RANSCREENER
R
T RANSCREENER
R
sample preparation, offering greater mean value calculations of samples in
Red FI validated
application flexibility and opening up multiple disposable Cell Chips.
Far Red FP validated Red TR-FRET validated
No matter what your application, the Spark 10M multimode reader delivers the
ideal combination of advanced capabilities and exceptional ease of use, enhancing
productivity with a series of unique features and benefits.
R = 0,98957
Automated cell imaging and confluence measurements 100
90
Confluence %
microplate to have confidence in your cell-based assay results. 60 10% 30%
50
The problem is that you don’t know how many cells have adhered 40 70% 90%
to the bottom of the microplate, or even grown, over a certain 30
20
period of time. It is now possible to automatically measure cell 10
Maintain stable culture conditions and improve cell growth 600 5000 cells / medium with FCS
An integrated Gas Control Module (GCM™) features two independent 500 ■ Spark
■ no GCM
gas inlets that allow automated control of CO2 and O2 concentrations 400
· Software-controlled, automated adjustments for real-time modulation Comparison of cell proliferation in the
of gas concentrations during a run Spark 10M reader with integrated GCM
and a standard microplate reader.
Absorption
3,5
absorbance measurements
3 Spark 10M’s patent-pending High-Speed Monochromator (HSM) delivers
complete spectra – from 200–1,000 nm – in just 5 seconds. These ultra-
OD
2,5
2 fast measurements offer the speed of a diode array with the precision and
1,5 flexibility of a monochromator for wide-ranging and detailed spectra.
1
0,5
0
Fast absorbance scan of a didymium filter
200 300 400 500 600 700 800 900 1000
Wavelength [nm] from 200–1,000 nm with 1 nm resolution
4.00
is a luminescent bead-based assay technology designed for the measurement
4,00
3.62
3,62
[ng/ml Omnibeads]
3.50
3,50
[ng/mL Omnibeads]
3.00
3,00
light source for excitation, and an IR sensor for well-by-well temperature 2.50
2,50
correction. This results in better sensitivity, uniformity and linearity for 2.00
2,00
1,58
1.58
your Alpha assays. SparkControl also offers preselected filter settings for 1.50
1,50
0.50
settings for future Alpha Technology applications.
0,50
0.00
0,00
Spark
Spark Sparktemp.
Spark temp. corr.
corr.
2.5
2
Ambient
% CV
1.5
Improved temperature control with Te-Cool 28 °C
1
A stable temperature is a prerequisite for getting reliable results. Whether 0.5
need precise, controllable cooling. Now, for the first time, Te-Cool lets you Assays run at equilibrated ambient temperatures
keep your assay stable at a specific temperature for long periods. lead to better sensitivity. The CV is shown for
absorbance readings taken at 570 nm every 5
min with Spark set to ambient temperature with
For most readers, the specified minimum temperature inside a plate reader is Te-Cool vs. a higher temperature set at 28 oC.
defined as a few degrees above ambient. This can vary significantly depending
on the time of year and location, and so will your results. Temperature gradients 1.400 Ambient +8 °C CV=14,6
1.300 Ambient +4 °C
can also occur across a microplate with many readers, leading to poor precision 1.200 Ambient
Luminescence [RLU]
Standard OR
Substrate
FIRST
MEASUREMENT
Substrate
SECOND
MEASUREMENT
High definition well scans provide SparkControl makes it easy to adjust Get instant access to applications
a complete picture of the cell parameters during a run, including and enjoy easy operation with
population in each well for more environmental conditions such as SparkControl’s one-click, workflow-
accurate signals, even with inhomo– temperature (even below ambient) based interface. The software makes
geneous cell layers. The software and the CO2 and O2 levels inside it easy and intuitive to translate your
also provides a qualitative image of the reader. workflow into a saved protocol that
the cell distribution. can be run or edited at any time.
App App
Cuvette Labelleling
Efficiency Automated z-focus adjustment Simplify the workflow for cell-based
enhances the sensitivity of top- assays with the cell confluence
reading fluorescence intensity and feature. Increase confidence for
One-click applications streamline fluorescence polarization modes, cytotoxicity, cell proliferation, and
your workflows, getting you from significantly improving the quality protein expression assays by, for
sample to results faster than ever of results. No matter what your example, automatically controlling
before. plate volume, sample volume or well the addition of compounds at a
shape, this unique feature makes user-defined cell confluence.
it easy to set up your reader for
optimum performance with varying
assay parameters.
SPARK 10M BROCHURE 07
Extended
dynamic range
Detect even very low signals with the SparkControl Magellan is a data analysis package
Spark 10M’s extended dynamic range.
providing powerful data reduction tools for numerous
This function automatically adjusts the
gain settings during a measurement detection modes.
run, allowing the detection of very
low signals without compromising on SparkControl Magellan offers The software provides a suite of
sensitivity. All results are automatically users an array of tools designed to sophisticated functions including:
correlated and displayed within one enhance functionality, simplicity · Full qualitative and quantitative
single data set. and security. EIA analysis
· I deal for microplate-based · A ll major curve fittings, including
applications such as ELISAs, point-to-p oint, linear regression,
end-point assays, kinetic assays, non-linear regression, polynomial,
ratiometric measurements, cubic spline, Akima, logit-log,
multi-label measurements and four- and five-parameter fits
3D scanning · C onvenient handling of dilution
Kinetic assay · Rapidly perform everything from series and ICx calculations
data reduction and curve fitting · G eneral data import and export
protection
to the calculation of kinetic options, as well as automated
parameters, such as Michaelis- import of sample ID lists.
Safeguard your kinetic assays using Menten constants · K inetic data analysis with
automated gain regulation to avoid · V ideo tutorials and example files calculation of slopes, onsets
fluorescence measurements running simplify operation and enzyme kinetics
into saturation. Measurements with · Plate definition editor allows · S pectral calculations to provide
different gain settings are then creation of customized plate rapid background correction,
automatically correlated, allowing geometry files curve smoothing, wavelength
evaluation of the entire dataset. selection, peak identification and
3D scanning
7
Typical performance values*
Absorbance AlphaScreen
Light source Dedicated Limit of detection ≤100 amol/well bio-LCK-P6; 20 µl
xenon flash lamp ≤2.5 ng/ml Omnibeads7; 20 µl
Spectral range 200–1,000 nm Uniformity ≤3.0%
OD range 0–4 OD Z´value ≥0.9
Scan speed (200–1,000 nm) ≤5 sec Fastest read times8 ≤2 min (384-well plate)
Wavelength accuracy <0.3 nm ≤1 min (96-well plate)
Wavelength reproducibility ≤0.3 nm Cell counting
Wavelength ratio accuracy (260/230) <0.08 Size range 4–90 µm
Wavelength ratio accuracy (260/280) <0.07 Counting accuracy +/–10% (10–30 µm)
Precision @ 260 nm <0.2% Counting reproducibility <10% (10–30 µm)
Accuracy @ 260 nm <0.5% Cell concentration 1x104–1x107 cells/ml
Limit of detection (nucleic acids) <1 ng/µl Imaging speed inc. data reduction <30 sec/sample
Number of samples/run ≤8 samples
Fluorescence intensity
Light source Dedicated xenon flash lamp Automated cell imaging
Spectral range Ex: 230–900 nm; Em: 280–900 nm Illumination High power LED
Wavelength accuracy Ex: <1 nm; Em: <2 nm Image Bright-field
Wavelength reproducibility <1 nm Objective 4x
Optical mirrors 50%; 510 nm dichroic Autofocus Laser based
Well scanning Up to 100 x 100 data points Optical resolution 1.3 µm/pixel
Limit of detection1
Gas Control Module
Fusion F/F – top ≤0.25 pM (≤25 amol/well; 100 µl)
Adjustable concentration range – CO2 0.04–10% (vol.)
Fusion M/F or F/M – top ≤0.35 pM (≤35 amol/well; 100 µl)
Adjustable concentration range – O2 0.1–21% (vol.)
Fusion M/M – top ≤0.50 pM (≤50 amol/well; 100 µl)
Concentration accuracy – CO2 <1% (vol.)
Fusion F/F – bottom ≤2.5 pM (≤0.5 fmol/well; 200 µl)
Concentration accuracy – O2 <0.5% (vol.)
Fusion M/F or F/M – bottom ≤3.5 pM (≤0.7 fmol/well; 200 µl)
Fusion M/M – bottom ≤4.0 pM (≤0.8 fmol/well; 200 µl) Reagent injectors
Syringe sizes 0.5 ml; 1 ml
FP (fluorescence polarization)2
Pump speed 100–300 µl/sec
Spectral range 300–850 nm
Injection volume 5–1,000 µl; step size: 1 µl
Precision – Fusion F/F ≤1.5 mP
Dead volume ≤100 µl
Precision – Fusion F/M ≤2.5 mP
Injection accuracy and precision ≤0.5% at 450 µl
Precision – Fusion M/F ≤2.5 mP
Precision – Fusion M/M ≤3.0 mP Temperature control Ambient +4 °C (up to 42 °C)
Uniformity <0.5 °C
TRF (time-resolved fluorescence) 3
Limit of detection – Fusion F/F ≤40 fM (≤4.0 amol/well; 100 µl) Te-Cool cooling module
Limit of detection – Fusion F/M ≤65 fM (≤6.5 amol/well; 100 µl) Temperature range +18–42 °C
Limit of detection – Fusion M/F ≤65 fM (≤6.5 amol/well; 100 µl)
Shaking
Limit of detection – Fusion M/M ≤100 fM (≤10 amol/well; 100 µl)
Linear, orbital, double-orbital;
Luminescence variable amplitudes and frequencies
Spectral range 370–700 nm
Plate formats
Luminescence (glow)
Up to 384 wells; NanoQuant Plate; Cell Chip;
Limit of detection4 ≤9 pM (≤225 amol/well; 25 µl)
Cuvettes; Roboflask
Luminescence (flash)
Limit of detection5 ≤218 fM (≤12 amol/well; 55 µl) Fastest read time
Dynamic range >9 orders of magnitude 96-well plate (FI) ≤13 sec
Multi-color luminescence 38 spectral filters; 384-well plate (FI) ≤30 sec
OD1, OD2, OD3 attenuation filters
* Specifications are subject to change. Performance values represent the average observed factory tested values.
For product specifications refer to operators manual.
1) D
etection limit for fluorescein; Fusion Optics: F-Filter; M-Monochromator; 5) Detection limit for ATP (ENLITEN® Kit)
2) FP detection limit @ 1 nM fluorescein 6) (PE# 6760620; P-Tyr-100 assay kit)
3) Detection limit for europium 7) (PE# 6760626D; Omnibeads)
4) Detection limit for ATP (144-041 ATP detection kit SL [BioTherma]) 8) Including temperature correction
Australia +61 3 9647 4100 Austria +43 62 46 89 33 Belgium +32 15 42 13 19 China +86 21 220 63 206 Denmark +45 70 23 44 50 France +33 4 72 76 04 80
Germany +49 79 51 94 170 Italy +39 02 92 44 790 Japan +81 44 556 73 11 Netherlands +31 18 34 48 17 4 Singapore +65 644 41 886 Spain +34 93 490 01 74
Sweden +46 8 750 39 40 Switzerland +41 44 922 89 22 UK +44 118 9300 300 USA +1 919 361 5200 Other countries +43 62 46 89 33
398454 V3.0 01-2016, 30110115
Tecan Group Ltd. makes every effort to include accurate and up-to-date information within this publication, however, it is possible that omissions or errors
might have occurred. Tecan Group Ltd. cannot, therefore, make any representations or warranties, expressed or implied, as to the accuracy or completeness
of the information provided in this publication. Changes in this publication can be made at any time without notice. All mentioned trademarks are protected
by law. In general, the trademarks and designs referenced herein are trademarks, or registered trademarks, of Tecan Group Ltd., Männedorf, Switzerland. A
complete list may be found at http://www.tecan.com/trademarks. Product names and company names that are not contained in the list but are noted herein
may be the trademarks of their respective owners. For technical details and detailed procedures of the specifications provided in this document please
contact your Tecan representative.
Tecan is in major countries a registered trademark of Tecan Group Ltd., Männedorf, Switzerland.
© 2016 Tecan Trading AG, Switzerland, all rights reserved.
www.tecan.com