t NDT & CORROSION CONTROL SERVICES, PO BOX: 322, DAMMAM-31411, KSA. POSITIVE MATERIAL IDENTIFICATION TEST REPORT. CUSTOMER: J.0.NO/B.I.NO: INSPECTION BY DATE SEPCO ARABIA 10-01525-0004 Qa/gc 10-02-2020 DESCRIPTION: REPORT No# 3707 IDENTIFICATION MARK: 2! '-10-30017-1SA0P2 SA ~ PRG-4-PMr-F- FW-SEC1- 2''- FLANGE EQUIPMENT MODEL SERIAL NO: CALIBRATION VALID UNTIL: MASTER SMART 57W0008 08/07/2020 TEST TECHNIQUE: INSTRUMENT MAKE: DATE: PME. (SPARK) OXFORD INSTRUMENTS . GERNANY GRADE: 3042 Fe # ¢C % Si % Mn % Cr % Mo # Ni & Cu % Nb & Min 0.0000 0.0000 0.0000 18.0 8.00 Max 0.0300 1.00 2.00 20.0 12.0 1 69.7 0.0243 0.452 1.41 19.2 0.117 8.67 0.108 0.0161 1 8 Min Max 1 0.0056 RESULT: ACCEPT / REJECT ACCEPTANCE CRITERIA: 1. Alloy shall be acceptable if the alloying element are each within 10% of the specified range of value. 2. welds with consumables that match or nearly match, the base metal composition shall be within +/- 12.5% of the ranges allowed in ASME section IIC for each element and SAES-A-206 NDT TECHINICIAN SEPCO ARABIA QA/QC SAUDI ARAMCO “ES _A