You are on page 1of 2

Fuse, Harness In-Line Page 1 of 2

 
019-198 Fuse, Harness In-Line
 
 

Inspect

Remove the fuse 
protective covers   
from the fuse(s)   
that are being 
checked. Check 
 
to make sure the   
fuse is installed 
in the fuse holder 
correctly. 

 
If the fuse is 
installed   
correctly, check   
for a blown fuse. 
 
Remove the fuse  
(s) to be 
checked. 
 
 
Touch each one 
of the multimeter 
leads to each 
fuse terminal.   
Measure the 
resistance. 

The multimeter 
must show less 
than 10 ohms, 
which is a closed 

mk:@MSITStore:G:\MR_D.CHM::/english/procedures/99/99-019-198.html 13/07/2020
Fuse, Harness In-Line Page 2 of 2

circuit. If the 
circuit is closed 
then put the fuse 
back into the 
holder and 
connect the fuse 
cover. 
 
 

Last Modified: 21-Mar-2012

Copyright © 2000-2010  Cummins Inc.  All rights reserved. 

mk:@MSITStore:G:\MR_D.CHM::/english/procedures/99/99-019-198.html 13/07/2020