Crankcase Gases (Blowby) Excessive
Symptom Tree t027
Cause Correction
Check the turbocharger compressor and
Turbocharger oil seal is leaking turbine seals. Refer to Procedures 010-
033.
Check the valve guides for wear.
Cylinder head valve guides are
Replace the cylinder head if necessary.
excessively worn
Refer to Procedure 002-004.
Check the pistons, piston rings, and
Cylinder liner, pistons, or piston rings are
cylinder liner. Refer to Procedures 001-
worn or damaged
043, 001-047 and 001-028.