019-197 Ring Terminal
Connector Replacement
Terminals are used for various
connections including grounds
and fuel shutoff valve supply.
Use wire crimp tool, Part
Number 3822930, to cut
and remove the ring
terminal connector as
shown.
Use wire crimp tool, Part
Number 3822930, to
remove 6 mm [1/4 in] of
insulation from the harness
wire.
mk:@MSITStore:G:\MR_D.CHM::/english/procedures/99/99-019-197.html 13/07/2020
Ring Terminal Page 2 of 3
Install the proper-size ring
terminal on the bare wire.
The ring terminals that are
included in the wiring repair
kit, Part Number 3164572,
are as follows:
Ring Terminal
Part No.
Size
No. 10 3823760
1/2 inch 3823761
CAUTION
Only use wire crimping
pliers, Part Number
3822930, when repairing
electrical terminals.
Crimp the repair wire on the
bare wire.
Use a heat gun, Part Number
3822860, or open flame to
heat the shrink tubing. The
tubing will shrink and make
the connection waterproof.
mk:@MSITStore:G:\MR_D.CHM::/english/procedures/99/99-019-197.html 13/07/2020
Ring Terminal Page 3 of 3
Last Modified: 21-Mar-2012
Copyright © 2000-2010 Cummins Inc. All rights reserved.