You are on page 1of 3

Ring Terminal Page 1 of 3

 
019-197   Ring Terminal 
 
 

Connector Replacement 

Terminals are used for various   
connections including grounds 
and fuel shutoff valve supply. 

 
Use wire crimp tool, Part 
Number 3822930, to cut   
and remove the ring   
terminal connector as 
shown. 

 
Use wire crimp tool, Part 
Number 3822930, to   
remove 6 mm [1/4 in] of   
insulation from the harness 
wire. 

mk:@MSITStore:G:\MR_D.CHM::/english/procedures/99/99-019-197.html 13/07/2020
Ring Terminal Page 2 of 3

 
Install the proper-size ring 
terminal on the bare wire.   
The ring terminals that are   
included in the wiring repair 
kit, Part Number 3164572, 
are as follows: 

Ring Terminal 
Part No. 
Size 
No. 10  3823760 
1/2 inch  3823761 
 

 CAUTION     
 
 
Only use wire crimping 
pliers, Part Number 
3822930, when repairing 
electrical terminals. 

Crimp the repair wire on the 
bare wire. 

Use a heat gun, Part Number   
3822860, or open flame to 
heat the shrink tubing. The 
tubing will shrink and make 
the connection waterproof. 
 
 

mk:@MSITStore:G:\MR_D.CHM::/english/procedures/99/99-019-197.html 13/07/2020
Ring Terminal Page 3 of 3