018-018 Cooling System
Specifications
Coolant Capacity
Engine only High Temperature Water Circuit 181 liters [48 gal]
Low Temperature Aftercooler (LTA) Water Circuit 34 liters [9 gal]
Jacket Water Outlet Temperature
High Temperature 90°C [194°F] or 95°C [203°F]
Thermostat Modulating Range (Multiple Turbocharger Engine only)
High Temperature 83° to 95°C [181° to 202°F]
Low Temperature 46° to 57°C [115° to 135°F]
Electronic Temperature Control Valve Modulating Range (Single Turbocharger Engine only)
High Temperature 87° to 90°C [189° to 194°F]
Low Temperature 37° to 40°C [99° to 104°F]
NOTE: Use the monthly average dewpoint to determine the maximum power for a given LTA
return temperature