You are on page 1of 103

Daikin Altherma high

temperature split
Technical Data
EPRA014-018DV

EEDEN22
TABLE OF CONTENTS

EPRA014-018DV
1 Features 4
EPRA014-018DV4

2 Specifications 5

3 Electrical data 87

4 Capacity graphs 88
Cooling Capacity Graphs 88
Heating Capacity Graphs 90

5 Capacity tables 92
Certification Programs 92
Domestic Hot Water performance 93

6 Dimensional drawings 94

7 Piping diagrams 95

8 Wiring diagrams 96
Wiring Diagrams - Single Phase 96

9 Sound data 97
Sound Pressure Spectrum - Cooling 97
Sound Pressure Spectrum - Heating 98
Sound Pressure Spectrum Quiet Mode 99

10 Installation 101
Installation Method 101

11 Operation range 102

3
Daikin Altherma high temperature split • EPRA014-018DV

1 Features
1 - 1 EPRA014-018DV
›› By heat pump operation only, the outdoor unit delivers a leaving ›› The unit’s sleek design blends in with other household appliances.
water temperature of 70°C at -15°C ambient temperature ›› Choosing for an R-32 product, reduces the environmental impact
1 ›› By -15°C ambient temperature, the outdoor unit limits heating with 68% compared to R-410A, leads directly to lower energy
capacity loss consumption thanks to its high energy efficiency and has a 30%
›› Outdoor unit extracts heat from the outdoor air, even at -28°C lower refrigerant charge

Guaranteed
operation
down to -28°C

4 E PRA014-018DV
Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETBH16E6V + ETBH16E6V + ETBH16E6V +
Technical specifications
EPRA14DV3 EPRA16DV3 EPRA18DV3
Heating capacity Min. kW 3.70 (1) 3.96 (1) 4.40 (1)
Nom. kW 5.69 (2) 9.00 (2) 2
Max. kW 10.18 (1) 10.91 (1) 12.12 (1)
Power input Heating Min. kW 0.88 (3) 0.95 (3) 1.05 (3)
Nom. kW 1.22 (2) 1.80 (2)
Max. kW 2.09 (3) 2.24 (3) 2.49 (3)
COP 4.67 (2) 5.00 (2)
Pump Type Grundfos UPMXL GEO 25-125 130 PWM
Nominal Heating kPa 111.2 (4) 97.4 (4)
ESP unit
Water side Heat Water Heating Nom. l/min 16.3 (2) 25.8 (2)
exchanger flow rate
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manu- Name or trademark Daikin Europe N.V.
facturer
details
Product Air-to-water heat pump Yes
descrip- Brine-to-water heat pump No
tion Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated Yes
Water-to-water heat pump No
LW(A) SoundIndoor dB(A) 44.0
power level
(according to
EN14825)
LW(A) Sound pow- Outdoor dB(A) 54.0
er level (according
to EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Space heating Air to Rated airflow (outdoor) m³/h 3,918 3,960
general water
unit
Other Capacity control Inverter
Pck (Crankcase heater mode) kW 0.000
Poff (Off mode) kW 0.021
Psb (Standby mode) kW 0.021
Pto (Thermostat off) kW 0.041
Inte- Psup kW 6.0
grated Type of energy input Electrical
supple-
mentary
heater
Space heating Average General Annual energy kWh 7,211
climate consumption
water ηs (Seasonal % 140
outlet space heating
55°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 26
gy consumption
(GCV)
SCOP 3.58
Seasonal space heating A++
eff. class
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB)

Daikin Altherma high temperature split • EPRA014-018DV 5


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETBH16E6V + ETBH16E6V + ETBH16E6V +
Technical specifications
EPRA14DV3 EPRA16DV3 EPRA18DV3
Space heating Average A Condition COPd 2.47
2 climate (-7°CDB/-8°CWB) Pdh kW 11.2
water PERd % 98.8
outlet B Con- Cdh (Degradation heating) 1.0
55°C dition COPd 3.56
(2°CD- Pdh kW 6.9
B/1°CWB) PERd % 142.4
C Con- Cdh (Degradation heating) 1.0
dition COPd 4.44
(7°CD- Pdh kW 6.9
B/6°CWB) PERd % 177.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.72
Pdh kW 6.2
PERd % 228.8
Tol (tem- COPd 2.19
perature Pdh kW 12.2
operat- PERd % 87.6
ing limit) TOL °C -10
WTOL °C 55
Rated Psup (at Tdesign kW 0.3
heat -10°C)
output
supple-
mentary
capacity
Tbiv COPd 2.19
(bivalent Pdh kW 12.2
tempera- PERd % 87.6
ture) Tbiv °C -10
Cold General Annual energy kWh 9,654
climate consumption
water ηs (Seasonal % 125
outlet space heating
55°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 35
gy consumption
(GCV)
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.74
Pdh kW 7.5
PERd % 109.6
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 5.8
B/1°CWB) PERd % 146.8

6 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETBH16E6V + ETBH16E6V + ETBH16E6V +
Technical specifications
EPRA14DV3 EPRA16DV3 EPRA18DV3
Space heating Cold C Con- Cdh (Degradation heating) 1.0
climate dition COPd 4.69 2
water (7°CD- Pdh kW 5.6
outlet B/6°CWB) PERd % 187.6
55°C D Condition COPd 6.12
(12°CDB/11°CWB) Pdh kW 6.2
PERd % 244.8
Tol (tem- COPd 1.65
perature Pdh kW 10.6
operat- PERd % 66.0
ing limit) TOL °C -22
WTOL °C 55
G Con- COPd 2.17
dition Pdh kW 10.3
(-15°CDB/- PERd % 86.8
)
Tbiv COPd 1.90
(bivalent Pdh kW 11.0
tempera- PERd % 76.0
ture) Tbiv °C -18
Rated Psup (at Tdesign kW 1.9
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 4,090
climate consumption
water ηs (Seasonal % 160
outlet space heating
55°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 15
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 2.45
(2°CD- Pdh kW 10.0
B/1°CWB) PERd % 98.0
C Con- Cdh (Degradation heating) 1.0
dition COPd 3.69
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 147.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.39
Pdh kW 5.9
PERd % 215.6
Tbiv COPd 3.27
(bivalent
tempera-
ture)

Daikin Altherma high temperature split • EPRA014-018DV 7


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETBH16E6V + ETBH16E6V + ETBH16E6V +
Technical specifications
EPRA14DV3 EPRA16DV3 EPRA18DV3
Space heating Warm Tbiv Pdh kW 9.9
2 climate (bivalent PERd % 130.8
water tempera- Tbiv °C 5
outlet ture)
55°C
Water H Condi- Max. kW 11.1 11.8
outlet tion (-2°C
45°C /-)
Average General Annual energy kWh 5,726
climate consumption
water ηs (Seasonal % 177
outlet space heating
35°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 21
gy consumption
(GCV)
SCOP 4.51
Seasonal space heating A+++
eff. class
A Condition COPd 3.12
(-7°CDB/-8°CWB) Pdh kW 11.1
PERd % 124.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 4.44
(2°CD- Pdh kW 6.7
B/1°CWB) PERd % 177.6
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.84
(7°CD- Pdh kW 5.7
B/6°CWB) PERd % 233.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.40
Pdh kW 6.0
PERd % 296.0
Tol (tem- COPd 2.76
perature Pdh kW 11.1
operat- PERd % 110.4
ing limit) TOL °C -10
WTOL °C 35
Tbiv COPd 3.12
(bivalent Pdh kW 11.1
tempera- PERd % 124.8
ture) Tbiv °C -7
Rated Psup (at Tdesign kW 1.4
heat -10°C)
output
supple-
mentary
capacity
Cold General Annual energy kWh 7,417
climate consumption
water ηs (Seasonal % 163
outlet space heating
35°C efficiency)

8 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETBH16E6V + ETBH16E6V + ETBH16E6V +
Technical specifications
EPRA14DV3 EPRA16DV3 EPRA18DV3
Space heating Cold General Prated at -22°C kW 13
climate Qhe Annual ener- Gj 27 2
water gy consumption
outlet (GCV)
35°C A Condition COPd 3.50
(-7°CDB/-8°CWB) Pdh kW 8.0
PERd % 140.0
B Con- Cdh (Degradation heating) 1.0
dition COPd 5.07
(2°CD- Pdh kW 4.9
B/1°CWB) PERd % 202.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 6.10
(7°CD- Pdh kW 5.3
B/6°CWB) PERd % 244.0
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.03
Pdh kW 5.7
PERd % 281.2
Tol (tem- COPd 2.16
perature Pdh kW 10.1
operat- PERd % 86.4
ing limit) TOL °C -22
WTOL °C 35
G Con- COPd 2.62
dition Pdh kW 10.7
(-15°CDB/- PERd % 104.8
)
Tbiv COPd 2.62
(bivalent Pdh kW 10.7
tempera- PERd % 104.8
ture) Tbiv °C -15
Rated Psup (at Tdesign kW 2.4
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 2,885
climate consumption
water ηs (Seasonal % 229
outlet space heating
35°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 10
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 9.8
Space heating Warm B Con- PERd % 146.8
climate dition
water (2°CD-
outlet B/1°CWB)
35°C C Con- Cdh (Degradation heating) 1.0
dition COPd 5.60
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 224.0
Tbiv COPd 4.95
(bivalent Pdh kW 9.8
tempera- PERd % 198.0
ture) Tbiv °C 5
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.60
Pdh kW 6.1
PERd % 304.0
(1)Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C |
(2)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(3)Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 |
(4)DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed |
Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB |
Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB |
Test at Ta DB/WB 7°C/6°C. According to EN 16147.

Daikin Altherma high temperature split • EPRA014-018DV 9


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETBH16E9W + ETBH16E9W + ETBH16E9W +
Technical specifications
EPRA14DV3 EPRA16DV3 EPRA18DV3
Heating capacity Min. kW 3.70 (1) 3.96 (1) 4.40 (1)
2 Nom. kW 5.69 (2) 9.00 (2)
Max. kW 10.18 (1) 10.91 (1) 12.12 (1)
Power input Heating Min. kW 0.88 (3) 0.95 (3) 1.05 (3)
Nom. kW 1.22 (2) 1.80 (2)
Max. kW 2.09 (3) 2.24 (3) 2.49 (3)
COP 4.67 (2) 5.00 (2)
Pump Type Grundfos UPMXL GEO 25-125 130 PWM
Nominal Heating kPa 111.2 (4) 97.4 (4)
ESP unit
Water side Heat Water Heating Nom. l/min 16.3 (2) 25.8 (2)
exchanger flow rate
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manu- Name or trademark Daikin Europe N.V.
facturer
details
Product Air-to-water heat pump Yes
descrip- Brine-to-water heat pump No
tion Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated Yes
Water-to-water heat pump No
LW(A) SoundIndoor dB(A) 44.0
power level
(according to
EN14825)
LW(A) Sound pow- Outdoor dB(A) 54.0
er level (according
to EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Space heating Air to Rated airflow (outdoor) m³/h 3,918 3,960
general water
unit
Other Capacity control Inverter
Pck (Crankcase heater mode) kW 0.000
Poff (Off mode) kW 0.021
Psb (Standby mode) kW 0.021
Pto (Thermostat off) kW 0.041
Inte- Psup kW 9.0
grated Type of energy input Electrical
supple-
mentary
heater
Space heating Average General Annual energy kWh 7,211
climate consumption
water ηs (Seasonal % 140
outlet space heating
55°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 26
gy consumption
(GCV)
SCOP 3.58
Seasonal space heating A++
eff. class
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB)

10 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETBH16E9W + ETBH16E9W + ETBH16E9W +
Technical specifications
EPRA14DV3 EPRA16DV3 EPRA18DV3
Space heating Average A Condition COPd 2.47
climate (-7°CDB/-8°CWB) Pdh kW 11.2 2
water PERd % 98.8
outlet B Con- Cdh (Degradation heating) 1.0
55°C dition COPd 3.56
(2°CD- Pdh kW 6.9
B/1°CWB) PERd % 142.4
C Con- Cdh (Degradation heating) 1.0
dition COPd 4.44
(7°CD- Pdh kW 6.9
B/6°CWB) PERd % 177.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.72
Pdh kW 6.2
PERd % 228.8
Tol (tem- COPd 2.19
perature Pdh kW 12.2
operat- PERd % 87.6
ing limit) TOL °C -10
WTOL °C 55
Rated Psup (at Tdesign kW 0.3
heat -10°C)
output
supple-
mentary
capacity
Tbiv COPd 2.19
(bivalent Pdh kW 12.2
tempera- PERd % 87.6
ture) Tbiv °C -10
Cold General Annual energy kWh 9,654
climate consumption
water ηs (Seasonal % 125
outlet space heating
55°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 35
gy consumption
(GCV)
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.74
Pdh kW 7.5
PERd % 109.6
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 5.8
B/1°CWB) PERd % 146.8

Daikin Altherma high temperature split • EPRA014-018DV 11


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETBH16E9W + ETBH16E9W + ETBH16E9W +
Technical specifications
EPRA14DV3 EPRA16DV3 EPRA18DV3
Space heating Cold C Con- Cdh (Degradation heating) 1.0
2 climate dition COPd 4.69
water (7°CD- Pdh kW 5.6
outlet B/6°CWB) PERd % 187.6
55°C D Condition COPd 6.12
(12°CDB/11°CWB) Pdh kW 6.2
PERd % 244.8
Tol (tem- COPd 1.65
perature Pdh kW 10.6
operat- PERd % 66.0
ing limit) TOL °C -22
WTOL °C 55
G Con- COPd 2.17
dition Pdh kW 10.3
(-15°CDB/- PERd % 86.8
)
Tbiv COPd 1.90
(bivalent Pdh kW 11.0
tempera- PERd % 76.0
ture) Tbiv °C -18
Rated Psup (at Tdesign kW 1.9
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 4,090
climate consumption
water ηs (Seasonal % 160
outlet space heating
55°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 15
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 2.45
(2°CD- Pdh kW 10.0
B/1°CWB) PERd % 98.0
C Con- Cdh (Degradation heating) 1.0
dition COPd 3.69
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 147.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.39
Pdh kW 5.9
PERd % 215.6
Tbiv COPd 3.27
(bivalent
tempera-
ture)

12 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETBH16E9W + ETBH16E9W + ETBH16E9W +
Technical specifications
EPRA14DV3 EPRA16DV3 EPRA18DV3
Space heating Warm Tbiv Pdh kW 9.9
climate (bivalent PERd % 130.8 2
water tempera- Tbiv °C 5
outlet ture)
55°C
Water H Condi- Max. kW 11.1 11.8
outlet tion (-2°C
45°C /-)
Average General Annual energy kWh 5,726
climate consumption
water ηs (Seasonal % 177
outlet space heating
35°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 21
gy consumption
(GCV)
SCOP 4.51
Seasonal space heating A+++
eff. class
A Condition COPd 3.12
(-7°CDB/-8°CWB) Pdh kW 11.1
PERd % 124.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 4.44
(2°CD- Pdh kW 6.7
B/1°CWB) PERd % 177.6
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.84
(7°CD- Pdh kW 5.7
B/6°CWB) PERd % 233.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.40
Pdh kW 6.0
PERd % 296.0
Tol (tem- COPd 2.76
perature Pdh kW 11.1
operat- PERd % 110.4
ing limit) TOL °C -10
WTOL °C 35
Tbiv COPd 3.12
(bivalent Pdh kW 11.1
tempera- PERd % 124.8
ture) Tbiv °C -7
Rated Psup (at Tdesign kW 1.4
heat -10°C)
output
supple-
mentary
capacity
Cold General Annual energy kWh 7,417
climate consumption
water ηs (Seasonal % 163
outlet space heating
35°C efficiency)

Daikin Altherma high temperature split • EPRA014-018DV 13


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETBH16E9W + ETBH16E9W + ETBH16E9W +
Technical specifications
EPRA14DV3 EPRA16DV3 EPRA18DV3
Space heating Cold General Prated at -22°C kW 13
2 climate Qhe Annual ener- Gj 27
water gy consumption
outlet (GCV)
35°C A Condition COPd 3.50
(-7°CDB/-8°CWB) Pdh kW 8.0
PERd % 140.0
B Con- Cdh (Degradation heating) 1.0
dition COPd 5.07
(2°CD- Pdh kW 4.9
B/1°CWB) PERd % 202.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 6.10
(7°CD- Pdh kW 5.3
B/6°CWB) PERd % 244.0
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.03
Pdh kW 5.7
PERd % 281.2
Tol (tem- COPd 2.16
perature Pdh kW 10.1
operat- PERd % 86.4
ing limit) TOL °C -22
WTOL °C 35
G Con- COPd 2.62
dition Pdh kW 10.7
(-15°CDB/- PERd % 104.8
)
Tbiv COPd 2.62
(bivalent Pdh kW 10.7
tempera- PERd % 104.8
ture) Tbiv °C -15
Rated Psup (at Tdesign kW 2.4
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 2,885
climate consumption
water ηs (Seasonal % 229
outlet space heating
35°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 10
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 9.8
Space heating Warm B Con- PERd % 146.8
climate dition
water (2°CD-
outlet B/1°CWB)
35°C C Con- Cdh (Degradation heating) 1.0
dition COPd 5.60
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 224.0
Tbiv COPd 4.95
(bivalent Pdh kW 9.8
tempera- PERd % 198.0
ture) Tbiv °C 5
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.60
Pdh kW 6.1
PERd % 304.0
(1)Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C |
(2)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(3)Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 |
(4)DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed |
Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB |
Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB |
Test at Ta DB/WB 7°C/6°C. According to EN 16147.

14 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
Technical specifications ETBX16E6V + EPRA14DV3 ETBX16E6V + EPRA16DV3 ETBX16E6V + EPRA18DV3
Heating capacity Min. kW 3.70 (1) 3.96 (1) 4.40 (1)
Nom. kW 5.69 (2) 9.00 (2)

Cooling capacity
Max.
Nom.
kW
kW
10.18 (1)
10.6 (3) / 6.90 (4)
10.91 (1)
11.5 (3) / 7.88 (4)
12.12 (1)
12.5 (3) / 8.86 (4)
2
Power input Heating Min. kW 0.88 (5) 0.95 (5) 1.05 (5)
Nom. kW 1.22 (2) 1.80 (2)
Max. kW 2.09 (5) 2.24 (5) 2.49 (5)
Cooling Nom. kW 2.55 (3) / 2.56 (4) 2.80 (3) / 2.93 (4) 3.05 (3) / 3.31 (4)
COP 4.67 (2) 5.00 (2)
EER 4.13 (3) / 2.70 (4) 4.11 (3) / 2.69 (4) 4.09 (3) / 2.68 (4)
Pump Type Grundfos UPMXL GEO 25-125 130 PWM
Nominal Heating kPa 111.2 (6) 97.4 (6)
ESP unit
Water side Heat Water Heating Nom. l/min 16.3 (2) 25.8 (2)
exchanger flow rate
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manu- Name or trademark Daikin Europe N.V.
facturer
details
Product Air-to-water heat pump Yes
descrip- Brine-to-water heat pump No
tion Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated Yes
Water-to-water heat pump No
LW(A) Sound Indoor dB(A) 44.0
power level
(according to
EN14825)
LW(A) Sound pow- Outdoor dB(A) 54.0
er level (according
to EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Space heating Air to Rated airflow (outdoor) m³/h 3,918 3,960
general water
unit
Other Capacity control Inverter
Pck (Crankcase heater mode) kW 0.000
Poff (Off mode) kW 0.021
Psb (Standby mode) kW 0.021
Pto (Thermostat off) kW 0.041
Inte- Psup kW 6.0
grated Type of energy input Electrical
supple-
mentary
heater
Space heating Average General Annual energy kWh 7,134
climate consumption
water ηs (Seasonal % 142
outlet space heating
55°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 26
gy consumption
(GCV)

Daikin Altherma high temperature split • EPRA014-018DV 15


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
Technical specifications ETBX16E6V + EPRA14DV3 ETBX16E6V + EPRA16DV3 ETBX16E6V + EPRA18DV3
Space heating Average General SCOP 3.62
climate Seasonal space heating A++
2 water
outlet
eff. class
A Condition Cdh (Degradation heating) 1.0
55°C (-7°CDB/-8°CWB) COPd 2.47
Pdh kW 11.2
PERd % 98.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.56
(2°CD- Pdh kW 6.9
B/1°CWB) PERd % 142.4
C Con- Cdh (Degradation heating) 1.0
dition COPd 4.44
(7°CD- Pdh kW 6.9
B/6°CWB) PERd % 177.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.72
Pdh kW 6.2
PERd % 228.8
Tol (tem- COPd 2.19
perature Pdh kW 12.2
operat- PERd % 87.6
ing limit) TOL °C -10
WTOL °C 55
Rated Psup (at Tdesign kW 0.3
heat -10°C)
output
supple-
mentary
capacity
Tbiv COPd 2.19
(bivalent Pdh kW 12.2
tempera- PERd % 87.6
ture) Tbiv °C -10
Cold General Annual energy kWh 9,609
climate consumption
water ηs (Seasonal % 125
outlet space heating
55°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 35
gy consumption
(GCV)
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.74
Pdh kW 7.5
PERd % 109.6
B Con- Cdh (Degradation heating) 1.0
dition
(2°CD-
B/1°CWB)

16 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
Technical specifications ETBX16E6V + EPRA14DV3 ETBX16E6V + EPRA16DV3 ETBX16E6V + EPRA18DV3
Space heating Cold B Con- COPd 3.67
climate dition Pdh kW 5.8
water
outlet
(2°CD-
B/1°CWB)
PERd % 146.8
2
55°C C Con- Cdh (Degradation heating) 1.0
dition COPd 4.69
(7°CD- Pdh kW 5.6
B/6°CWB) PERd % 187.6
D Condition COPd 6.12
(12°CDB/11°CWB) Pdh kW 6.2
PERd % 244.8
Tol (tem- COPd 1.65
perature Pdh kW 10.6
operat- PERd % 66.0
ing limit) TOL °C -22
WTOL °C 55
G Con- COPd 2.17
dition Pdh kW 10.3
(-15°CDB/- PERd % 86.8
)
Tbiv COPd 1.90
(bivalent Pdh kW 11.0
tempera- PERd % 76.0
ture) Tbiv °C -18
Rated Psup (at Tdesign kW 1.9
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 3,997
climate consumption
water ηs (Seasonal % 164
outlet space heating
55°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 14
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 2.45
(2°CD- Pdh kW 10.0
B/1°CWB) PERd % 98.0
C Con- Cdh (Degradation heating) 1.0
dition COPd 3.69
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 147.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.39

Daikin Altherma high temperature split • EPRA014-018DV 17


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
Technical specifications ETBX16E6V + EPRA14DV3 ETBX16E6V + EPRA16DV3 ETBX16E6V + EPRA18DV3
Space heating Warm D Condition Pdh kW 5.9
climate (12°CDB/11°CWB) PERd % 215.6
2 water
outlet
Tbiv
(bivalent
COPd
Pdh kW
3.27
9.9
55°C tempera- PERd % 130.8
ture) Tbiv °C 5
Water H Condi- Max. kW 11.1 11.8
outlet tion (-2°C
45°C /-)
Average General Annual energy kWh 5,649
climate consumption
water ηs (Seasonal % 180
outlet space heating
35°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 20
gy consumption
(GCV)
SCOP 4.57
Seasonal space heating A+++
eff. class
A Condition COPd 3.12
(-7°CDB/-8°CWB) Pdh kW 11.1
PERd % 124.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 4.44
(2°CD- Pdh kW 6.7
B/1°CWB) PERd % 177.6
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.84
(7°CD- Pdh kW 5.7
B/6°CWB) PERd % 233.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.40
Pdh kW 6.0
PERd % 296.0
Tol (tem- COPd 2.76
perature Pdh kW 11.1
operat- PERd % 110.4
ing limit) TOL °C -10
WTOL °C 35
Tbiv COPd 3.12
(bivalent Pdh kW 11.1
tempera- PERd % 124.8
ture) Tbiv °C -7

18 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
Technical specifications ETBX16E6V + EPRA14DV3 ETBX16E6V + EPRA16DV3 ETBX16E6V + EPRA18DV3
Space heating Average Rated Psup (at Tdesign kW 1.4
climate heat -10°C)
water
outlet
output
supple-
2
35°C mentary
capacity
Cold General Annual energy kWh 7,370
climate consumption
water ηs (Seasonal % 164
outlet space heating
35°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 27
gy consumption
(GCV)
A Condition COPd 3.50
(-7°CDB/-8°CWB) Pdh kW 8.0
PERd % 140.0
B Con- Cdh (Degradation heating) 1.0
dition COPd 5.07
(2°CD- Pdh kW 4.9
B/1°CWB) PERd % 202.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 6.10
(7°CD- Pdh kW 5.3
B/6°CWB) PERd % 244.0
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.03
Pdh kW 5.7
PERd % 281.2
Tol (tem- COPd 2.16
perature Pdh kW 10.1
operat- PERd % 86.4
ing limit) TOL °C -22
WTOL °C 35
G Con- COPd 2.62
dition Pdh kW 10.7
(-15°CDB/- PERd % 104.8
)
Tbiv COPd 2.62
(bivalent Pdh kW 10.7
tempera- PERd % 104.8
ture) Tbiv °C -15
Rated Psup (at Tdesign kW 2.4
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 2,792
climate consumption
water ηs (Seasonal % 236
outlet space heating
35°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 10
gy consumption
(GCV)

Daikin Altherma high temperature split • EPRA014-018DV 19


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
Technical specifications ETBX16E6V + EPRA14DV3 ETBX16E6V + EPRA16DV3 ETBX16E6V + EPRA18DV3
Space heating Warm B Con- Cdh (Degradation heating) 1.0
climate dition COPd 3.67
2 water
outlet
(2°CD-
B/1°CWB)
Pdh
PERd
kW
%
9.8
146.8
35°C C Con- Cdh (Degradation heating) 1.0
dition COPd 5.60
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 224.0
Tbiv COPd 4.95
(bivalent Pdh kW 9.8
tempera- PERd % 198.0
ture) Tbiv °C 5
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.60
Pdh kW 6.1
PERd % 304.0
(1)Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C |
(2)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(3)Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB |
(4)Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB |
(5)Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 |
(6)DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed |
Test at Ta DB/WB 7°C/6°C. According to EN 16147.

ETBX16E9W + ETBX16E9W + ETBX16E9W +


Technical specifications
EPRA14DV3 EPRA16DV3 EPRA18DV3
Heating capacity Min. kW 3.70 (1) 3.96 (1) 4.40 (1)
Nom. kW 5.69 (2) 9.00 (2)
Max. kW 10.18 (1) 10.91 (1) 12.12 (1)
Cooling capacity Nom. kW 10.6 (3) / 6.90 (4) 11.5 (3) / 7.88 (4) 12.5 (3) / 8.86 (4)
Power input Heating Min. kW 0.88 (5) 0.95 (5) 1.05 (5)
Nom. kW 1.22 (2) 1.80 (2)
Max. kW 2.09 (5) 2.24 (5) 2.49 (5)
Cooling Nom. kW 2.55 (3) / 2.56 (4) 2.80 (3) / 2.93 (4) 3.05 (3) / 3.31 (4)
COP 4.67 (2) 5.00 (2)
EER 4.13 (3) / 2.70 (4) 4.11 (3) / 2.69 (4) 4.09 (3) / 2.68 (4)
Pump Type Grundfos UPMXL GEO 25-125 130 PWM
Nominal Heating kPa 111.2 (6) 97.4 (6)
ESP unit
Water side Heat Water Heating Nom. l/min 16.3 (2) 25.8 (2)
exchanger flow rate
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manu- Name or trademark Daikin Europe N.V.
facturer
details
Product Air-to-water heat pump Yes
descrip- Brine-to-water heat pump No
tion Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated Yes
Water-to-water heat pump No
LW(A) Sound Indoor dB(A) 44.0
power level
(according to
EN14825)
LW(A) Sound pow- Outdoor dB(A) 54.0
er level (according
to EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Space heating Air to Rated airflow (outdoor) m³/h 3,918 3,960
general water
unit
Other Capacity control Inverter
Pck (Crankcase heater mode) kW 0.000
Poff (Off mode) kW 0.021
Psb (Standby mode) kW 0.021
Pto (Thermostat off) kW 0.041
Inte- Psup kW 9.0
grated Type of energy input Electrical
supple-
mentary
heater

20 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETBX16E9W + ETBX16E9W + ETBX16E9W +
Technical specifications
EPRA14DV3 EPRA16DV3 EPRA18DV3
Space heating Average General Annual energy kWh 7,134
climate consumption 2
water ηs (Seasonal % 142
outlet space heating
55°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 26
gy consumption
(GCV)
Space heating Average General SCOP 3.62
climate Seasonal space heating A++
water eff. class
outlet A Condition Cdh (Degradation heating) 1.0
55°C (-7°CDB/-8°CWB) COPd 2.47
Pdh kW 11.2
PERd % 98.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.56
(2°CD- Pdh kW 6.9
B/1°CWB) PERd % 142.4
C Con- Cdh (Degradation heating) 1.0
dition COPd 4.44
(7°CD- Pdh kW 6.9
B/6°CWB) PERd % 177.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.72
Pdh kW 6.2
PERd % 228.8
Tol (tem- COPd 2.19
perature Pdh kW 12.2
operat- PERd % 87.6
ing limit) TOL °C -10
WTOL °C 55
Rated Psup (at Tdesign kW 0.3
heat -10°C)
output
supple-
mentary
capacity
Tbiv COPd 2.19
(bivalent Pdh kW 12.2
tempera- PERd % 87.6
ture) Tbiv °C -10
Cold General Annual energy kWh 9,609
climate consumption
water ηs (Seasonal % 125
outlet space heating
55°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 35
gy consumption
(GCV)
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.74
Pdh kW 7.5
PERd % 109.6
B Con- Cdh (Degradation heating) 1.0
dition
(2°CD-
B/1°CWB)

Daikin Altherma high temperature split • EPRA014-018DV 21


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETBX16E9W + ETBX16E9W + ETBX16E9W +
Technical specifications
EPRA14DV3 EPRA16DV3 EPRA18DV3
Space heating Cold B Con- COPd 3.67
2 climate dition Pdh kW 5.8
water (2°CD- PERd % 146.8
outlet B/1°CWB)
55°C C Con- Cdh (Degradation heating) 1.0
dition COPd 4.69
(7°CD- Pdh kW 5.6
B/6°CWB) PERd % 187.6
D Condition COPd 6.12
(12°CDB/11°CWB) Pdh kW 6.2
PERd % 244.8
Tol (tem- COPd 1.65
perature Pdh kW 10.6
operat- PERd % 66.0
ing limit) TOL °C -22
WTOL °C 55
G Con- COPd 2.17
dition Pdh kW 10.3
(-15°CDB/- PERd % 86.8
)
Tbiv COPd 1.90
(bivalent Pdh kW 11.0
tempera- PERd % 76.0
ture) Tbiv °C -18
Rated Psup (at Tdesign kW 1.9
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 3,997
climate consumption
water ηs (Seasonal % 164
outlet space heating
55°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 14
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 2.45
(2°CD- Pdh kW 10.0
B/1°CWB) PERd % 98.0
C Con- Cdh (Degradation heating) 1.0
dition COPd 3.69
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 147.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.39

22 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETBX16E9W + ETBX16E9W + ETBX16E9W +
Technical specifications
EPRA14DV3 EPRA16DV3 EPRA18DV3
Space heating Warm D Condition Pdh kW 5.9
climate (12°CDB/11°CWB) PERd % 215.6 2
water Tbiv COPd 3.27
outlet (bivalent Pdh kW 9.9
55°C tempera- PERd % 130.8
ture) Tbiv °C 5
Water H Condi- Max. kW 11.1 11.8
outlet tion (-2°C
45°C /-)
Average General Annual energy kWh 5,649
climate consumption
water ηs (Seasonal % 180
outlet space heating
35°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 20
gy consumption
(GCV)
SCOP 4.57
Seasonal space heating A+++
eff. class
A Condition COPd 3.12
(-7°CDB/-8°CWB) Pdh kW 11.1
PERd % 124.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 4.44
(2°CD- Pdh kW 6.7
B/1°CWB) PERd % 177.6
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.84
(7°CD- Pdh kW 5.7
B/6°CWB) PERd % 233.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.40
Pdh kW 6.0
PERd % 296.0
Tol (tem- COPd 2.76
perature Pdh kW 11.1
operat- PERd % 110.4
ing limit) TOL °C -10
WTOL °C 35
Tbiv COPd 3.12
(bivalent Pdh kW 11.1
tempera- PERd % 124.8
ture) Tbiv °C -7

Daikin Altherma high temperature split • EPRA014-018DV 23


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETBX16E9W + ETBX16E9W + ETBX16E9W +
Technical specifications
EPRA14DV3 EPRA16DV3 EPRA18DV3
Space heating Average Rated Psup (at Tdesign kW 1.4
2 climate heat -10°C)
water output
outlet supple-
35°C mentary
capacity
Cold General Annual energy kWh 7,370
climate consumption
water ηs (Seasonal % 164
outlet space heating
35°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 27
gy consumption
(GCV)
A Condition COPd 3.50
(-7°CDB/-8°CWB) Pdh kW 8.0
PERd % 140.0
B Con- Cdh (Degradation heating) 1.0
dition COPd 5.07
(2°CD- Pdh kW 4.9
B/1°CWB) PERd % 202.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 6.10
(7°CD- Pdh kW 5.3
B/6°CWB) PERd % 244.0
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.03
Pdh kW 5.7
PERd % 281.2
Tol (tem- COPd 2.16
perature Pdh kW 10.1
operat- PERd % 86.4
ing limit) TOL °C -22
WTOL °C 35
G Con- COPd 2.62
dition Pdh kW 10.7
(-15°CDB/- PERd % 104.8
)
Tbiv COPd 2.62
(bivalent Pdh kW 10.7
tempera- PERd % 104.8
ture) Tbiv °C -15
Rated Psup (at Tdesign kW 2.4
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 2,792
climate consumption
water ηs (Seasonal % 236
outlet space heating
35°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 10
gy consumption
(GCV)

24 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETBX16E9W + ETBX16E9W + ETBX16E9W +
Technical specifications
EPRA14DV3 EPRA16DV3 EPRA18DV3
Space heating Warm B Con- Cdh (Degradation heating) 1.0
climate dition COPd 3.67 2
water (2°CD- Pdh kW 9.8
outlet B/1°CWB) PERd % 146.8
35°C C Con- Cdh (Degradation heating) 1.0
dition COPd 5.60
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 224.0
Tbiv COPd 4.95
(bivalent Pdh kW 9.8
tempera- PERd % 198.0
ture) Tbiv °C 5
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.60
Pdh kW 6.1
PERd % 304.0
(1)Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C |
(2)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(3)Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB |
(4)Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB |
(5)Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 |
(6)DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed |
Test at Ta DB/WB 7°C/6°C. According to EN 16147.

ETSH16P30E + ETSH16P50E + ETSH16P30E + ETSH16P50E + ETSH16P30E + ETSH16P50E +


Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Heating capacity Min. kW 3.70 (1) 3.96 (1) 4.40 (1)
Nom. kW 5.69 (2) 9.00 (2)
Max. kW 10.18 (1) 10.91 (1) 12.12 (1)
Power input Heating Min. kW 0.88 (3) 0.95 (3) 1.05 (3)
Nom. kW 1.22 (2) 1.80 (2)
Max. kW 2.09 (3) 2.24 (3) 2.49 (3)
COP 4.67 (2) 5.00 (2)
Pump Type Grundfos UPMXL 20-125 CHBL RT
Water side Heat Water Heating Nom. l/min 16.3 (2) 25.8 (2)
exchanger flow rate
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manu- Name or trademark Daikin Europe N.V.
facturer
details
Product Air-to-water heat pump Yes
descrip- Brine-to-water heat pump No
tion Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated No
Water-to-water heat pump No
LW(A) Sound Indoor dB(A) 45.6
power level
(according to
EN14825)
LW(A) Sound pow- Outdoor dB(A) 54.0
er level (according
to EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Space heating Air to Rated airflow (outdoor) m³/h 3,918 3,960
general water
unit
Other Capacity control Inverter
Pck (Crankcase heater mode) kW 0.000
Poff (Off mode) kW 0.021
Psb (Standby mode) kW 0.021
Pto (Thermostat off) kW 0.041

Daikin Altherma high temperature split • EPRA014-018DV 25


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSH16P30E + ETSH16P50E + ETSH16P30E + ETSH16P50E + ETSH16P30E + ETSH16P50E +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Domestic hot General Declared load profile L XL L XL L XL
2 water heating Function to fix water heating during No
off peak hours
Average AEC (Annual electricity kWh 825 1,338 825 1,338 825 1,338
climate consumption)
COPdhw 2.86 3.00 2.86 3.00 2.86 3.00
Heat up time 1h 25min 1h 44min 1h 25min 1h 44min 1h 25min 1h 44min
Mixed water at 40°C l 193.0 245.0 193.0 245.0 193.0 245.0
ηwh (water heating effi- % 124 125 124 125 124 125
ciency)
Qelec (Daily electricity kWh 4.075 6.346 4.075 6.346 4.075 6.346
consumption)
Reference hot water tem- °C 47.0 44.4 47.0 44.4 47.0 44.4
perature
Stand-by power input W 57.4 46.2 57.4 46.2 57.4 46.2
Domestic hot Average Water heating energy efficiency class A+
water heating climate
Cold AEC (Annual electricity kWh 1,151 1,570 1,151 1,570 1,151 1,570
climate consumption)
COPdhw 2.08 2.57 2.08 2.57 2.08 2.57
Heat up time 1h 22min 1h 45min 1h 22min 1h 45min 1h 22min 1h 45min
Mixed water at 40°C l 159.0 243.0 159.0 243.0 159.0 243.0
ηwh (water heating effi- % 89 107 89 107 89 107
ciency)
Qelec (Daily electricity kWh 5.595 7.416 5.595 7.416 5.595 7.416
consumption)
Reference hot water tem- °C 45.4 44.3 45.4 44.3 45.4 44.3
perature
Stand-by power input W 64.0 48.7 64.0 48.7 64.0 48.7
Warm AEC (Annual electricity kWh 696 1,155 696 1,155 696 1,155
climate consumption)
COPdhw 3.36 3.46 3.36 3.46 3.36 3.46
Heat up time 1h 40min 2h 02min 1h 40min 2h 02min 1h 40min 2h 02min
Mixed water at 40°C l 191.0 240.0 191.0 240.0 191.0 240.0
ηwh (water heating effi- % 147 145 147 145 147 145
ciency)
Qelec (Daily electricity kWh 3.468 5.516 3.468 5.516 3.468 5.516
consumption)
Reference hot water tem- °C 46.9 44.3 46.9 44.3 46.9 44.3
perature
Stand-by power input W 54.5 46.0 54.5 46.0 54.5 46.0
Space heating Average General Annual energy kWh 7,211
climate consumption
water ηs (Seasonal % 140
outlet space heating
55°C efficiency)
Prated at -10°C kW 12.5
Qhe Annual ener- Gj 26
gy consumption
(GCV)
SCOP 3.58
Seasonal space heating A++
eff. class
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.47
Pdh kW 11.2
PERd % 98.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.56
(2°CD- Pdh kW 6.9
B/1°CWB) PERd % 142.4
C Con- Cdh (Degradation heating) 1.0
dition COPd 4.44
(7°CD- Pdh kW 6.9
B/6°CWB) PERd % 177.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.72

26 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSH16P30E + ETSH16P50E + ETSH16P30E + ETSH16P50E + ETSH16P30E + ETSH16P50E +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Average D Condition Pdh kW 6.2
climate (12°CDB/11°CWB) PERd % 228.8 2
water Tol (tem- COPd 2.19
outlet perature Pdh kW 12.2
55°C operat- PERd % 87.6
ing limit) TOL °C -10
WTOL °C 55
Rated Psup (at Tdesign kW 0.3
heat -10°C)
output
supple-
mentary
capacity
Tbiv COPd 2.19
(bivalent Pdh kW 12.2
tempera- PERd % 87.6
ture) Tbiv °C -10
Cold General Annual energy kWh 9,654
climate consumption
water ηs (Seasonal % 125
outlet space heating
55°C efficiency)
Prated at -22°C kW 12.5
Qhe Annual ener- Gj 35
gy consumption
(GCV)
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.74
Pdh kW 7.5
PERd % 109.6
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 5.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 4.69
(7°CD- Pdh kW 5.6
B/6°CWB) PERd % 187.6
D Condition COPd 6.12
(12°CDB/11°CWB) Pdh kW 6.2
PERd % 244.8
Tol (tem- COPd 1.65
perature Pdh kW 10.6
operat- PERd % 66.0
ing limit) TOL °C -22
WTOL °C 55
G Con- COPd 2.17
dition
(-15°CDB/-
)

Daikin Altherma high temperature split • EPRA014-018DV 27


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSH16P30E + ETSH16P50E + ETSH16P30E + ETSH16P50E + ETSH16P30E + ETSH16P50E +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Cold G Con- Pdh kW 10.3
2 climate dition PERd % 86.8
water (-15°CDB/-
outlet )
55°C Tbiv COPd 1.90
(bivalent Pdh kW 11.0
tempera- PERd % 76.0
ture) Tbiv °C -18
Rated Psup (at Tdesign kW 1.9
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 4,090
climate consumption
water ηs (Seasonal % 160
outlet space heating
55°C efficiency)
Prated at 2°C kW 12.5
Qhe Annual ener- Gj 15
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 2.45
(2°CD- Pdh kW 10.0
B/1°CWB) PERd % 98.0
C Con- Cdh (Degradation heating) 1.0
dition COPd 3.69
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 147.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.39
Pdh kW 5.9
PERd % 215.6
Tbiv COPd 3.27
(bivalent Pdh kW 9.9
tempera- PERd % 130.8
ture) Tbiv °C 5
Water H Condi- Max. kW 11.1 11.8
outlet tion (-2°C
45°C /-)
Average General Annual energy kWh 5,726
climate consumption
water ηs (Seasonal % 177
outlet space heating
35°C efficiency)
Prated at -10°C kW 12.5
Qhe Annual ener- Gj 21
gy consumption
(GCV)
SCOP 4.51
Seasonal space heating A+++
eff. class
A Condition COPd 3.12
(-7°CDB/-8°CWB) Pdh kW 11.1
PERd % 124.8

28 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSH16P30E + ETSH16P50E + ETSH16P30E + ETSH16P50E + ETSH16P30E + ETSH16P50E +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Average B Con- Cdh (Degradation heating) 1.0
climate dition COPd 4.44 2
water (2°CD- Pdh kW 6.7
outlet B/1°CWB) PERd % 177.6
35°C C Con- Cdh (Degradation heating) 1.0
dition COPd 5.84
(7°CD- Pdh kW 5.7
B/6°CWB) PERd % 233.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.40
Pdh kW 6.0
PERd % 296.0
Tol (tem- COPd 2.76
perature Pdh kW 11.1
operat- PERd % 110.4
ing limit) TOL °C -10
WTOL °C 35
Tbiv COPd 3.12
(bivalent Pdh kW 11.1
tempera- PERd % 124.8
ture) Tbiv °C -7
Rated Psup (at Tdesign kW 1.4
heat -10°C)
output
supple-
mentary
capacity
Cold General Annual energy kWh 7,417
climate consumption
water ηs (Seasonal % 163
outlet space heating
35°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 26.7
gy consumption
(GCV)
A Condition COPd 3.50
(-7°CDB/-8°CWB) Pdh kW 8.0
PERd % 140.0
B Con- Cdh (Degradation heating) 1.0
dition COPd 5.07
(2°CD- Pdh kW 4.9
B/1°CWB) PERd % 202.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 6.10
(7°CD- Pdh kW 5.3
B/6°CWB) PERd % 244.0

Daikin Altherma high temperature split • EPRA014-018DV 29


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSH16P30E + ETSH16P50E + ETSH16P30E + ETSH16P50E + ETSH16P30E + ETSH16P50E +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Cold D Condition Cdh (Degradation heating) 1.0
2 climate (12°CDB/11°CWB) COPd 7.03
water Pdh kW 5.7
outlet PERd % 281.2
35°C Tol (tem- COPd 2.16
perature Pdh kW 10.1
operat- PERd % 86.4
ing limit) TOL °C -22
WTOL °C 35
G Con- COPd 2.62
dition Pdh kW 10.7
(-15°CDB/- PERd % 104.8
)
Tbiv COPd 2.62
(bivalent Pdh kW 10.7
tempera- PERd % 104.8
ture) Tbiv °C -15
Rated Psup (at Tdesign kW 2.4
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 2,885
climate consumption
water ηs (Seasonal % 229
outlet space heating
35°C efficiency)
Prated at 2°C kW 12.5
Qhe Annual ener- Gj 10
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 9.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.60
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 224.0
Tbiv COPd 4.95
(bivalent Pdh kW 9.8
tempera- PERd % 198.0
ture) Tbiv °C 5
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.60
Pdh kW 6.1
PERd % 304.0
(1)Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C |
(2)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(3)Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 |
Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB |
Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB

ETSHB16P30E + ETSHB16P50E + ETSHB16P30E + ETSHB16P50E + ETSHB16P30E + ETSHB16P50E +


Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Heating capacity Min. kW 3.70 (1) 3.96 (1) 4.40 (1)
Nom. kW 5.69 (2) 9.00 (2)
Max. kW 10.18 (1) 10.91 (1) 12.12 (1)
Power input Heating Min. kW 0.88 (3) 0.95 (3) 1.05 (3)
Nom. kW 1.22 (2) 1.80 (2)
Max. kW 2.09 (3) 2.24 (3) 2.49 (3)
COP 4.67 (2) 5.00 (2)
Pump Type Grundfos UPMXL 20-125 CHBL RT
Water side Heat Water Heating Nom. l/min 16.3 (2) 25.8 (2)
exchanger flow rate

30 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSHB16P30E + ETSHB16P50E + ETSHB16P30E + ETSHB16P50E + ETSHB16P30E + ETSHB16P50E +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manu- Name or trademark Daikin Europe N.V. 2
facturer
details
Product Air-to-water heat pump Yes
descrip- Brine-to-water heat pump No
tion Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated No
Water-to-water heat pump No
LW(A) Sound Indoor dB(A) 45.6
power level
(according to
EN14825)
LW(A) Sound pow- Outdoor dB(A) 54.0
er level (according
to EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Space heating Air to Rated airflow (outdoor) m³/h 3,918 3,960
general water
unit
Other Capacity control Inverter
Pck (Crankcase heater mode) kW 0.000
Poff (Off mode) kW 0.021
Psb (Standby mode) kW 0.021
Pto (Thermostat off) kW 0.041
Domestic hot General Declared load profile L XL L XL L XL
water heating Function to fix water heating during No
off peak hours
Average AEC (Annual electricity kWh 825 1,338 825 1,338 825 1,338
climate consumption)
COPdhw 2.86 3.00 2.86 3.00 2.86 3.00
Heat up time 1h 25min 1h 44min 1h 25min 1h 44min 1h 25min 1h 44min
Mixed water at 40°C l 193.0 245.0 193.0 245.0 193.0 245.0
ηwh (water heating effi- % 124 125 124 125 124 125
ciency)
Qelec (Daily electricity kWh 4.075 6.346 4.075 6.346 4.075 6.346
consumption)
Reference hot water tem- °C 47.0 44.4 47.0 44.4 47.0 44.4
perature
Stand-by power input W 57.4 46.2 57.4 46.2 57.4 46.2
Domestic hot Average Water heating energy efficiency class A+
water heating climate
Cold AEC (Annual electricity kWh 1,151 1,570 1,151 1,570 1,151 1,570
climate consumption)
COPdhw 2.08 2.57 2.08 2.57 2.08 2.57
Heat up time 1h 22min 1h 45min 1h 22min 1h 45min 1h 22min 1h 45min
Mixed water at 40°C l 159.0 243.0 159.0 243.0 159.0 243.0
ηwh (water heating effi- % 89 107 89 107 89 107
ciency)
Qelec (Daily electricity kWh 5.595 7.416 5.595 7.416 5.595 7.416
consumption)
Reference hot water tem- °C 45.4 44.3 45.4 44.3 45.4 44.3
perature
Stand-by power input W 64.0 48.7 64.0 48.7 64.0 48.7
Warm AEC (Annual electricity kWh 696 1,155 696 1,155 696 1,155
climate consumption)
COPdhw 3.36 3.46 3.36 3.46 3.36 3.46
Heat up time 1h 40min 2h 02min 1h 40min 2h 02min 1h 40min 2h 02min
Mixed water at 40°C l 191.0 240.0 191.0 240.0 191.0 240.0
ηwh (water heating effi- % 147 145 147 145 147 145
ciency)
Qelec (Daily electricity kWh 3.468 5.516 3.468 5.516 3.468 5.516
consumption)
Reference hot water tem- °C 46.9 44.3 46.9 44.3 46.9 44.3
perature
Stand-by power input W 54.5 46.0 54.5 46.0 54.5 46.0

Daikin Altherma high temperature split • EPRA014-018DV 31


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSHB16P30E + ETSHB16P50E + ETSHB16P30E + ETSHB16P50E + ETSHB16P30E + ETSHB16P50E +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Average General Annual energy kWh 7,211
2 climate consumption
water ηs (Seasonal % 140
outlet space heating
55°C efficiency)
Prated at -10°C kW 12.5
Qhe Annual ener- Gj 26
gy consumption
(GCV)
SCOP 3.58
Seasonal space heating A++
eff. class
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.47
Pdh kW 11.2
PERd % 98.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.56
(2°CD- Pdh kW 6.9
B/1°CWB) PERd % 142.4
C Con- Cdh (Degradation heating) 1.0
dition COPd 4.44
(7°CD- Pdh kW 6.9
B/6°CWB) PERd % 177.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.72

32 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSHB16P30E + ETSHB16P50E + ETSHB16P30E + ETSHB16P50E + ETSHB16P30E + ETSHB16P50E +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Average D Condition Pdh kW 6.2
climate (12°CDB/11°CWB) PERd % 228.8 2
water Tol (tem- COPd 2.19
outlet perature Pdh kW 12.2
55°C operat- PERd % 87.6
ing limit) TOL °C -10
WTOL °C 55
Rated Psup (at Tdesign kW 0.3
heat -10°C)
output
supple-
mentary
capacity
Tbiv COPd 2.19
(bivalent Pdh kW 12.2
tempera- PERd % 87.6
ture) Tbiv °C -10
Cold General Annual energy kWh 9,654
climate consumption
water ηs (Seasonal % 125
outlet space heating
55°C efficiency)
Prated at -22°C kW 12.5
Qhe Annual ener- Gj 35
gy consumption
(GCV)
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.74
Pdh kW 7.5
PERd % 109.6
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 5.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 4.69
(7°CD- Pdh kW 5.6
B/6°CWB) PERd % 187.6
D Condition COPd 6.12
(12°CDB/11°CWB) Pdh kW 6.2
PERd % 244.8
Tol (tem- COPd 1.65
perature Pdh kW 10.6
operat- PERd % 66.0
ing limit) TOL °C -22
WTOL °C 55
G Con- COPd 2.17
dition
(-15°CDB/-
)

Daikin Altherma high temperature split • EPRA014-018DV 33


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSHB16P30E + ETSHB16P50E + ETSHB16P30E + ETSHB16P50E + ETSHB16P30E + ETSHB16P50E +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Cold G Con- Pdh kW 10.3
2 climate dition PERd % 86.8
water (-15°CDB/-
outlet )
55°C Tbiv COPd 1.90
(bivalent Pdh kW 11.0
tempera- PERd % 76.0
ture) Tbiv °C -18
Rated Psup (at Tdesign kW 1.9
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 4,090
climate consumption
water ηs (Seasonal % 160
outlet space heating
55°C efficiency)
Prated at 2°C kW 12.5
Qhe Annual ener- Gj 15
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 2.45
(2°CD- Pdh kW 10.0
B/1°CWB) PERd % 98.0
C Con- Cdh (Degradation heating) 1.0
dition COPd 3.69
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 147.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.39
Pdh kW 5.9
PERd % 215.6
Tbiv COPd 3.27
(bivalent Pdh kW 9.9
tempera- PERd % 130.8
ture) Tbiv °C 5
Water H Condi- Max. kW 11.1 11.8
outlet tion (-2°C
45°C /-)
Average General Annual energy kWh 5,726
climate consumption
water ηs (Seasonal % 177
outlet space heating
35°C efficiency)
Prated at -10°C kW 12.5
Qhe Annual ener- Gj 21
gy consumption
(GCV)
SCOP 4.51
Seasonal space heating A+++
eff. class
A Condition COPd 3.12
(-7°CDB/-8°CWB) Pdh kW 11.1
PERd % 124.8

34 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSHB16P30E + ETSHB16P50E + ETSHB16P30E + ETSHB16P50E + ETSHB16P30E + ETSHB16P50E +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Average B Con- Cdh (Degradation heating) 1.0
climate dition COPd 4.44 2
water (2°CD- Pdh kW 6.7
outlet B/1°CWB) PERd % 177.6
35°C C Con- Cdh (Degradation heating) 1.0
dition COPd 5.84
(7°CD- Pdh kW 5.7
B/6°CWB) PERd % 233.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.40
Pdh kW 6.0
PERd % 296.0
Tol (tem- COPd 2.76
perature Pdh kW 11.1
operat- PERd % 110.4
ing limit) TOL °C -10
WTOL °C 35
Tbiv COPd 3.12
(bivalent Pdh kW 11.1
tempera- PERd % 124.8
ture) Tbiv °C -7
Rated Psup (at Tdesign kW 1.4
heat -10°C)
output
supple-
mentary
capacity
Cold General Annual energy kWh 7,417
climate consumption
water ηs (Seasonal % 163
outlet space heating
35°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 26.7
gy consumption
(GCV)
A Condition COPd 3.50
(-7°CDB/-8°CWB) Pdh kW 8.0
PERd % 140.0
B Con- Cdh (Degradation heating) 1.0
dition COPd 5.07
(2°CD- Pdh kW 4.9
B/1°CWB) PERd % 202.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 6.10
(7°CD- Pdh kW 5.3
B/6°CWB) PERd % 244.0

Daikin Altherma high temperature split • EPRA014-018DV 35


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSHB16P30E + ETSHB16P50E + ETSHB16P30E + ETSHB16P50E + ETSHB16P30E + ETSHB16P50E +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Cold D Condition Cdh (Degradation heating) 1.0
2 climate (12°CDB/11°CWB) COPd 7.03
water Pdh kW 5.7
outlet PERd % 281.2
35°C Tol (tem- COPd 2.16
perature Pdh kW 10.1
operat- PERd % 86.4
ing limit) TOL °C -22
WTOL °C 35
G Con- COPd 2.62
dition Pdh kW 10.7
(-15°CDB/- PERd % 104.8
)
Tbiv COPd 2.62
(bivalent Pdh kW 10.7
tempera- PERd % 104.8
ture) Tbiv °C -15
Rated Psup (at Tdesign kW 2.4
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 2,885
climate consumption
water ηs (Seasonal % 229
outlet space heating
35°C efficiency)
Prated at 2°C kW 12.5
Qhe Annual ener- Gj 10
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 9.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.60
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 224.0
Tbiv COPd 4.95
(bivalent Pdh kW 9.8
tempera- PERd % 198.0
ture) Tbiv °C 5
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.60
Pdh kW 6.1
PERd % 304.0
(1)Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C |
(2)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(3)Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 |
Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB |
Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB

ETSX16P30E ETSX16P50E ETSX16P30E ETSX16P50E ETSX16P30E ETSX16P50E


Technical specifications + + + + + +
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Heating capacity Min. kW 3.70 (1) 3.96 (1) 4.40 (1)
Nom. kW 5.69 (2) 9.00 (2)
Max. kW 10.18 (1) 10.91 (1) 12.12 (1)
Cooling capacity Nom. kW 10.6 (3) / 6.90 (4) 11.5 (3) / 7.88 (4) 12.5 (3) / 8.86 (4)
Power input Heating Min. kW 0.88 (5) 0.95 (5) 1.05 (5)
Nom. kW 1.22 (2) 1.80 (2)
Max. kW 2.09 (5) 2.24 (5) 2.49 (5)
Cooling Nom. kW 2.55 (3) / 2.56 (4) 2.80 (3) / 2.93 (4) 3.05 (3) / 3.31 (4)
COP 4.67 (2) 5.00 (2)
EER 4.13 (3) / 2.70 (4) 4.11 (3) / 2.69 (4) 4.09 (3) / 2.68 (4)
Pump Type Grundfos UPMXL 20-125 CHBL RT
Water side Heat Water Heating Nom. l/min 16.3 (2) 25.8 (2)
exchanger flow rate

36 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSX16P30E ETSX16P50E ETSX16P30E ETSX16P50E ETSX16P30E ETSX16P50E
Technical specifications + + + + + +
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium 2
Manu- Name or trademark Daikin Europe N.V.
facturer
details
Product Air-to-water heat pump Yes
descrip- Brine-to-water heat pump No
tion Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated No
Water-to-water heat pump No
LW(A) Sound Indoor dB(A) 45.6
power level
(according to
EN14825)
LW(A) Sound pow- Outdoor dB(A) 54.0
er level (according
to EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Space heating Air to Rated airflow (outdoor) m³/h 3,918 3,960
general water
unit
Other Capacity control Inverter
Pck (Crankcase heater mode) kW 0.000
Poff (Off mode) kW 0.021
Psb (Standby mode) kW 0.021
Pto (Thermostat off) kW 0.041
Domestic hot General Declared load profile L XL L XL L XL
water heating Function to fix water heating during No
off peak hours
Average AEC (Annual electricity kWh 825 1,338 825 1,338 825 1,338
climate consumption)
COPdhw 2.86 3.00 2.86 3.00 2.86 3.00
Heat up time 1h 25min 1h 44min 1h 25min 1h 44min 1h 25min 1h 44min
Mixed water at 40°C l 193.0 245.0 193.0 245.0 193.0 245.0
ηwh (water heating effi- % 124 125 124 125 124 125
ciency)
Domestic hot Average Qelec (Daily electricity kWh 4.075 6.346 4.075 6.346 4.075 6.346
water heating climate consumption)
Reference hot water tem- °C 47.0 44.4 47.0 44.4 47.0 44.4
perature
Stand-by power input W 57.4 46.2 57.4 46.2 57.4 46.2
Water heating energy efficiency class A+
Cold AEC (Annual electricity kWh 1,151 1,570 1,151 1,570 1,151 1,570
climate consumption)
COPdhw 2.08 2.57 2.08 2.57 2.08 2.57
Heat up time 1h 22min 1h 45min 1h 22min 1h 45min 1h 22min 1h 45min
Mixed water at 40°C l 159.0 243.0 159.0 243.0 159.0 243.0
ηwh (water heating effi- % 89 107 89 107 89 107
ciency)
Qelec (Daily electricity kWh 5.595 7.416 5.595 7.416 5.595 7.416
consumption)
Reference hot water tem- °C 45.4 44.3 45.4 44.3 45.4 44.3
perature
Stand-by power input W 64.0 48.7 64.0 48.7 64.0 48.7
Warm AEC (Annual electricity kWh 696 1,155 696 1,155 696 1,155
climate consumption)
COPdhw 3.36 3.46 3.36 3.46 3.36 3.46
Heat up time 1h 40min 2h 02min 1h 40min 2h 02min 1h 40min 2h 02min
Mixed water at 40°C l 191.0 240.0 191.0 240.0 191.0 240.0
ηwh (water heating effi- % 147 145 147 145 147 145
ciency)
Qelec (Daily electricity kWh 3.468 5.516 3.468 5.516 3.468 5.516
consumption)
Reference hot water tem- °C 46.9 44.3 46.9 44.3 46.9 44.3
perature
Stand-by power input W 54.5 46.0 54.5 46.0 54.5 46.0

Daikin Altherma high temperature split • EPRA014-018DV 37


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSX16P30E ETSX16P50E ETSX16P30E ETSX16P50E ETSX16P30E ETSX16P50E
Technical specifications + + + + + +
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
2 Space heating Average General Annual energy kWh 7,134
climate consumption
water ηs (Seasonal % 142
outlet space heating
55°C efficiency)
Prated at -10°C kW 12.5
Qhe Annual ener- Gj 26
gy consumption
(GCV)
SCOP 3.62
Seasonal space heating A++
eff. class
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.47
Pdh kW 11.2
PERd % 98.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.56
(2°CD- Pdh kW 6.9
B/1°CWB) PERd % 142.4
C Condition Cdh (Degradation heating) 1.0
(7°CDB/6°CWB) COPd 4.44
Pdh kW 6.9

38 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSX16P30E ETSX16P50E ETSX16P30E ETSX16P50E ETSX16P30E ETSX16P50E
Technical specifications + + + + + +
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Average C Con- PERd % 177.6 2
climate dition
water (7°CD-
outlet B/6°CWB)
55°C D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.72
Pdh kW 6.2
PERd % 228.8
Tol (tem- COPd 2.19
perature Pdh kW 12.2
operat- PERd % 87.6
ing limit) TOL °C -10
WTOL °C 55
Rated Psup (at Tdesign kW 0.3
heat -10°C)
output
supple-
mentary
capacity
Tbiv COPd 2.19
(bivalent Pdh kW 12.2
tempera- PERd % 87.6
ture) Tbiv °C -10
Cold General Annual energy kWh 9,609
climate consumption
water ηs (Seasonal % 125
outlet space heating
55°C efficiency)
Prated at -22°C kW 12.5
Qhe Annual ener- Gj 35
gy consumption
(GCV)
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.74
Pdh kW 7.5
PERd % 109.6
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 5.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 4.69
(7°CD- Pdh kW 5.6
B/6°CWB) PERd % 187.6
D Condition COPd 6.12
(12°CDB/11°CWB) Pdh kW 6.2
PERd % 244.8
Tol (tempera- COPd 1.65
ture operating Pdh kW 10.6
limit) PERd % 66.0

Daikin Altherma high temperature split • EPRA014-018DV 39


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSX16P30E ETSX16P50E ETSX16P30E ETSX16P50E ETSX16P30E ETSX16P50E
Technical specifications + + + + + +
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
2 Space heating Cold Tol (tem- TOL °C -22
climate perature WTOL °C 55
water operat-
outlet ing limit)
55°C G Con- COPd 2.17
dition Pdh kW 10.3
(-15°CDB/- PERd % 86.8
)
Tbiv COPd 1.90
(bivalent Pdh kW 11.0
tempera- PERd % 76.0
ture) Tbiv °C -18
Rated Psup (at Tdesign kW 1.9
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 3,997
climate consumption
water ηs (Seasonal % 164
outlet space heating
55°C efficiency)
Prated at 2°C kW 12.5
Qhe Annual ener- Gj 14
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 2.45
(2°CD- Pdh kW 10.0
B/1°CWB) PERd % 98.0
C Con- Cdh (Degradation heating) 1.0
dition COPd 3.69
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 147.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.39
Pdh kW 5.9
PERd % 215.6
Tbiv COPd 3.27
(bivalent Pdh kW 9.9
tempera- PERd % 130.8
ture) Tbiv °C 5
Water H Condi- Max. kW 11.1 11.8
outlet tion (-2°C
45°C /-)
Average General Annual energy kWh 5,649
climate consumption
water ηs (Seasonal % 180
outlet space heating
35°C efficiency)
Prated at -10°C kW 12.5
Qhe Annual ener- Gj 20
gy consumption
(GCV)
SCOP 4.57
Seasonal space heating A+++
eff. class

40 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSX16P30E ETSX16P50E ETSX16P30E ETSX16P50E ETSX16P30E ETSX16P50E
Technical specifications + + + + + +
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Average A Condition COPd 3.12 2
climate (-7°CDB/-8°CWB) Pdh kW 11.1
water PERd % 124.8
outlet B Con- Cdh (Degradation heating) 1.0
35°C dition COPd 4.44
(2°CD- Pdh kW 6.7
B/1°CWB) PERd % 177.6
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.84
(7°CD- Pdh kW 5.7
B/6°CWB) PERd % 233.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.40
Pdh kW 6.0
PERd % 296.0
Tol (tem- COPd 2.76
perature Pdh kW 11.1
operat- PERd % 110.4
ing limit) TOL °C -10
WTOL °C 35
Tbiv COPd 3.12
(bivalent Pdh kW 11.1
tempera- PERd % 124.8
ture) Tbiv °C -7
Rated Psup (at Tdesign kW 1.4
heat -10°C)
output
supple-
mentary
capacity
Cold General Annual energy kWh 7,370
climate consumption
water ηs (Seasonal % 164
outlet space heating
35°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 26.5
gy consumption
(GCV)
A Condition COPd 3.50
(-7°CDB/-8°CWB) Pdh kW 8.0
PERd % 140.0
B Con- Cdh (Degradation heating) 1.0
dition COPd 5.07
(2°CD- Pdh kW 4.9
B/1°CWB) PERd % 202.8
C Con- Cdh (Degradation heating) 1.0
dition
(7°CD-
B/6°CWB)

Daikin Altherma high temperature split • EPRA014-018DV 41


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSX16P30E ETSX16P50E ETSX16P30E ETSX16P50E ETSX16P30E ETSX16P50E
Technical specifications + + + + + +
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
2 Space heating Cold C Con- COPd 6.10
climate dition Pdh kW 5.3
water (7°CD- PERd % 244.0
outlet B/6°CWB)
35°C D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.03
Pdh kW 5.7
PERd % 281.2
Tol (tem- COPd 2.16
perature Pdh kW 10.1
operat- PERd % 86.4
ing limit) TOL °C -22
WTOL °C 35
G Con- COPd 2.62
dition Pdh kW 10.7
(-15°CDB/- PERd % 104.8
)
Tbiv COPd 2.62
(bivalent Pdh kW 10.7
tempera- PERd % 104.8
ture) Tbiv °C -15
Rated Psup (at Tdesign kW 2.4
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 2,792
climate consumption
water ηs (Seasonal % 236
outlet space heating
35°C efficiency)
Prated at 2°C kW 12.5
Qhe Annual ener- Gj 10
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 9.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.60
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 224.0
Tbiv COPd 4.95
(bivalent Pdh kW 9.8
tempera- PERd % 198.0
ture) Tbiv °C 5
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB)
Space heating Warm D Condition COPd 7.60
climate (12°CDB/11°CWB) Pdh kW 6.1
water PERd % 304.0
(1)Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C |
(2)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(3)Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB |
(4)Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB |
(5)Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511

ETSXB16P30E + ETSXB16P50E + ETSXB16P30E + ETSXB16P50E + ETSXB16P30E + ETSXB16P50E +


Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Heating capacity Min. kW 3.70 (1) 3.96 (1) 4.40 (1)
Nom. kW 5.69 (2) 9.00 (2)
Max. kW 10.18 (1) 10.91 (1) 12.12 (1)
Cooling capacity Nom. kW 10.6 (3) / 6.90 (4) 11.5 (3) / 7.88 (4) 12.5 (3) / 8.86 (4)
Power input Heating Min. kW 0.88 (5) 0.95 (5) 1.05 (5)
Nom. kW 1.22 (2) 1.80 (2)
Max. kW 2.09 (5) 2.24 (5) 2.49 (5)
Cooling Nom. kW 2.55 (3) / 2.56 (4) 2.80 (3) / 2.93 (4) 3.05 (3) / 3.31 (4)
COP 4.67 (2) 5.00 (2)
EER 4.13 (3) / 2.70 (4) 4.11 (3) / 2.69 (4) 4.09 (3) / 2.68 (4)

42 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSXB16P30E + ETSXB16P50E + ETSXB16P30E + ETSXB16P50E + ETSXB16P30E + ETSXB16P50E +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Pump Type Grundfos UPMXL 20-125 CHBL RT
Water side Heat Water Heating Nom. l/min 16.3 (2) 25.8 (2) 2
exchanger flow rate
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manu- Name or trademark Daikin Europe N.V.
facturer
details
Product Air-to-water heat pump Yes
descrip- Brine-to-water heat pump No
tion Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated No
Water-to-water heat pump No
LW(A) Sound Indoor dB(A) 45.6
power level
(according to
EN14825)
LW(A) Sound pow- Outdoor dB(A) 54.0
er level (according
to EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Space heating Air to Rated airflow (outdoor) m³/h 3,918 3,960
general water
unit
Other Capacity control Inverter
Pck (Crankcase heater mode) kW 0.000
Poff (Off mode) kW 0.021
Psb (Standby mode) kW 0.021
Pto (Thermostat off) kW 0.041
Domestic hot General Declared load profile L XL L XL L XL
water heating Function to fix water heating during No
off peak hours
Average AEC (Annual electricity kWh 825 1,338 825 1,338 825 1,338
climate consumption)
COPdhw 2.86 3.00 2.86 3.00 2.86 3.00
Heat up time 1h 25min 1h 44min 1h 25min 1h 44min 1h 25min 1h 44min
Mixed water at 40°C l 193.0 245.0 193.0 245.0 193.0 245.0
ηwh (water heating effi- % 124 125 124 125 124 125
ciency)
Domestic hot Average Qelec (Daily electricity kWh 4.075 6.346 4.075 6.346 4.075 6.346
water heating climate consumption)
Reference hot water tem- °C 47.0 44.4 47.0 44.4 47.0 44.4
perature
Stand-by power input W 57.4 46.2 57.4 46.2 57.4 46.2
Water heating energy efficiency class A+
Cold AEC (Annual electricity kWh 1,151 1,570 1,151 1,570 1,151 1,570
climate consumption)
COPdhw 2.08 2.57 2.08 2.57 2.08 2.57
Heat up time 1h 22min 1h 45min 1h 22min 1h 45min 1h 22min 1h 45min
Mixed water at 40°C l 159.0 243.0 159.0 243.0 159.0 243.0
ηwh (water heating effi- % 89 107 89 107 89 107
ciency)
Qelec (Daily electricity kWh 5.595 7.416 5.595 7.416 5.595 7.416
consumption)
Reference hot water tem- °C 45.4 44.3 45.4 44.3 45.4 44.3
perature
Stand-by power input W 64.0 48.7 64.0 48.7 64.0 48.7
Warm AEC (Annual electricity kWh 696 1,155 696 1,155 696 1,155
climate consumption)
COPdhw 3.36 3.46 3.36 3.46 3.36 3.46
Heat up time 1h 40min 2h 02min 1h 40min 2h 02min 1h 40min 2h 02min
Mixed water at 40°C l 191.0 240.0 191.0 240.0 191.0 240.0
ηwh (water heating effi- % 147 145 147 145 147 145
ciency)
Qelec (Daily electricity kWh 3.468 5.516 3.468 5.516 3.468 5.516
consumption)
Reference hot water tem- °C 46.9 44.3 46.9 44.3 46.9 44.3
perature
Stand-by power input W 54.5 46.0 54.5 46.0 54.5 46.0

Daikin Altherma high temperature split • EPRA014-018DV 43


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSXB16P30E + ETSXB16P50E + ETSXB16P30E + ETSXB16P50E + ETSXB16P30E + ETSXB16P50E +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Average General Annual energy kWh 7,134
2 climate consumption
water ηs (Seasonal % 142
outlet space heating
55°C efficiency)
Prated at -10°C kW 12.5
Qhe Annual ener- Gj 26
gy consumption
(GCV)
SCOP 3.62
Seasonal space heating A++
eff. class
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.47
Pdh kW 11.2
PERd % 98.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.56
(2°CD- Pdh kW 6.9
B/1°CWB) PERd % 142.4
C Condition Cdh (Degradation heating) 1.0
(7°CDB/6°CWB) COPd 4.44
Pdh kW 6.9

44 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSXB16P30E + ETSXB16P50E + ETSXB16P30E + ETSXB16P50E + ETSXB16P30E + ETSXB16P50E +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Average C Con- PERd % 177.6
climate dition 2
water (7°CD-
outlet B/6°CWB)
55°C D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.72
Pdh kW 6.2
PERd % 228.8
Tol (tem- COPd 2.19
perature Pdh kW 12.2
operat- PERd % 87.6
ing limit) TOL °C -10
WTOL °C 55
Rated Psup (at Tdesign kW 0.3
heat -10°C)
output
supple-
mentary
capacity
Tbiv COPd 2.19
(bivalent Pdh kW 12.2
tempera- PERd % 87.6
ture) Tbiv °C -10
Cold General Annual energy kWh 9,609
climate consumption
water ηs (Seasonal % 125
outlet space heating
55°C efficiency)
Prated at -22°C kW 12.5
Qhe Annual ener- Gj 35
gy consumption
(GCV)
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.74
Pdh kW 7.5
PERd % 109.6
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 5.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 4.69
(7°CD- Pdh kW 5.6
B/6°CWB) PERd % 187.6
D Condition COPd 6.12
(12°CDB/11°CWB) Pdh kW 6.2
PERd % 244.8
Tol (tempera- COPd 1.65
ture operating Pdh kW 10.6
limit) PERd % 66.0

Daikin Altherma high temperature split • EPRA014-018DV 45


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSXB16P30E + ETSXB16P50E + ETSXB16P30E + ETSXB16P50E + ETSXB16P30E + ETSXB16P50E +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Cold Tol (tem- TOL °C -22
2 climate perature WTOL °C 55
water operat-
outlet ing limit)
55°C G Con- COPd 2.17
dition Pdh kW 10.3
(-15°CDB/- PERd % 86.8
)
Tbiv COPd 1.90
(bivalent Pdh kW 11.0
tempera- PERd % 76.0
ture) Tbiv °C -18
Rated Psup (at Tdesign kW 1.9
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 3,997
climate consumption
water ηs (Seasonal % 164
outlet space heating
55°C efficiency)
Prated at 2°C kW 12.5
Qhe Annual ener- Gj 14
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 2.45
(2°CD- Pdh kW 10.0
B/1°CWB) PERd % 98.0
C Con- Cdh (Degradation heating) 1.0
dition COPd 3.69
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 147.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.39
Pdh kW 5.9
PERd % 215.6
Tbiv COPd 3.27
(bivalent Pdh kW 9.9
tempera- PERd % 130.8
ture) Tbiv °C 5
Water H Condi- Max. kW 11.1 11.8
outlet tion (-2°C
45°C /-)
Average General Annual energy kWh 5,649
climate consumption
water ηs (Seasonal % 180
outlet space heating
35°C efficiency)
Prated at -10°C kW 12.5
Qhe Annual ener- Gj 20
gy consumption
(GCV)
SCOP 4.57
Seasonal space heating A+++
eff. class

46 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSXB16P30E + ETSXB16P50E + ETSXB16P30E + ETSXB16P50E + ETSXB16P30E + ETSXB16P50E +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Average A Condition COPd 3.12
climate (-7°CDB/-8°CWB) Pdh kW 11.1 2
water PERd % 124.8
outlet B Con- Cdh (Degradation heating) 1.0
35°C dition COPd 4.44
(2°CD- Pdh kW 6.7
B/1°CWB) PERd % 177.6
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.84
(7°CD- Pdh kW 5.7
B/6°CWB) PERd % 233.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.40
Pdh kW 6.0
PERd % 296.0
Tol (tem- COPd 2.76
perature Pdh kW 11.1
operat- PERd % 110.4
ing limit) TOL °C -10
WTOL °C 35
Tbiv COPd 3.12
(bivalent Pdh kW 11.1
tempera- PERd % 124.8
ture) Tbiv °C -7
Rated Psup (at Tdesign kW 1.4
heat -10°C)
output
supple-
mentary
capacity
Cold General Annual energy kWh 7,370
climate consumption
water ηs (Seasonal % 164
outlet space heating
35°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 26.5
gy consumption
(GCV)
A Condition COPd 3.50
(-7°CDB/-8°CWB) Pdh kW 8.0
PERd % 140.0
B Con- Cdh (Degradation heating) 1.0
dition COPd 5.07
(2°CD- Pdh kW 4.9
B/1°CWB) PERd % 202.8
C Con- Cdh (Degradation heating) 1.0
dition
(7°CD-
B/6°CWB)

Daikin Altherma high temperature split • EPRA014-018DV 47


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETSXB16P30E + ETSXB16P50E + ETSXB16P30E + ETSXB16P50E + ETSXB16P30E + ETSXB16P50E +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Cold C Con- COPd 6.10
2 climate dition Pdh kW 5.3
water (7°CD- PERd % 244.0
outlet B/6°CWB)
35°C D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.03
Pdh kW 5.7
PERd % 281.2
Tol (tem- COPd 2.16
perature Pdh kW 10.1
operat- PERd % 86.4
ing limit) TOL °C -22
WTOL °C 35
G Con- COPd 2.62
dition Pdh kW 10.7
(-15°CDB/- PERd % 104.8
)
Tbiv COPd 2.62
(bivalent Pdh kW 10.7
tempera- PERd % 104.8
ture) Tbiv °C -15
Rated Psup (at Tdesign kW 2.4
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 2,792
climate consumption
water ηs (Seasonal % 236
outlet space heating
35°C efficiency)
Prated at 2°C kW 12.5
Qhe Annual ener- Gj 10
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 9.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.60
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 224.0
Tbiv COPd 4.95
(bivalent Pdh kW 9.8
tempera- PERd % 198.0
ture) Tbiv °C 5
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB)
Space heating Warm D Condition COPd 7.60
climate (12°CDB/11°CWB) Pdh kW 6.1
water PERd % 304.0
(1)Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C |
(2)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(3)Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB |
(4)Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB |
(5)Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511

ETVH16S18E6V + ETVH16S23E6V + ETVH16S18E6V + ETVH16S23E6V + ETVH16S18E6V + ETVH16S23E6V +


Technical specifications EPRA14DAV3 EPRA16DAV3 EPRA18DAV3
EPRA14DV3 EPRA16DV3 EPRA18DV3
Heating capacity Min. kW 3.70 (1) 3.96 (1) 4.40 (1)
Nom. kW 5.69 (2) 9.00 (2)
Max. kW 10.18 (1) 10.91 (1) 12.12 (1)
Power input Heating Min. kW 0.88 (3) 0.95 (3) 1.05 (3)
Nom. kW 1.22 (2) 1.80 (2)
Max. kW 2.09 (3) 2.24 (3) 2.49 (3)
Domestic Nom. kWh 2.57 (4) 2.85 (4) 2.57 (4) 2.85 (4) 2.57 (4) 2.85 (4)
hot water
from 10°C
to 50°C

48 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVH16S18E6V + ETVH16S23E6V + ETVH16S18E6V + ETVH16S23E6V + ETVH16S18E6V + ETVH16S23E6V +
Technical specifications
EPRA14DV3 EPRA14DAV3 EPRA16DV3 EPRA16DAV3 EPRA18DV3 EPRA18DAV3
Heat up time from 10°C to 50°C hr 1h02min at 1h13min at 1h02min at 1h13min at 1h02min at 1h13min at
7°C ambient 7°C ambient 7°C ambient 7°C ambient 7°C ambient 7°C ambient 2
temperature temperature temperature temperature temperature temperature
COP 4.67 (2) 5.00 (2)
Pump Type Grundfos UPMXL GEO 25-125 130 PWM
Nominal Heating kPa 111.2 (5) 97.4 (5)
ESP unit
Water side Heat Water Heating Nom. l/min 16.3 (2) 25.8 (2)
exchanger flow rate
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manu- Name or trademark Daikin Europe N.V.
facturer
details
Product Air-to-water heat pump Yes
descrip- Brine-to-water heat pump No
tion Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated Yes
Water-to-water heat pump No
LW(A) SoundIndoor dB(A) 44.0
power level
(according to
EN14825)
LW(A) Sound pow- Outdoor dB(A) 54.0
er level (according
to EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Tank Name Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel
domestic hot domestic hot domestic hot domestic hot domestic hot domestic hot
water tank 180 l water tank 230 L water tank 180 l water tank 230 L water tank 180 l water tank 230 L
Space heating Air to Rated airflow (outdoor) m³/h 3,918 3,960
general water
unit
Other Capacity control Inverter
Pck (Crankcase heater mode) kW 0.000
Poff (Off mode) kW 0.021
Psb (Standby mode) kW 0.021
Pto (Thermostat off) kW 0.041
Domestic hot General Declared load profile L XL L XL L XL
water heating

Space heating Inte- Psup kW 6.0


general grated Type of energy input Electrical
supple-
mentary
heater
Domestic hot Average AEC (Annual electricity kWh 935 1,547 935 1,547 935 1,547
water heating climate consumption)
COPdhw 2.62 2.61 2.62 2.61 2.62 2.61
Heat up time 1h 06min 1h 19min 1h 06min 1h 19min 1h 06min 1h 19min

Daikin Altherma high temperature split • EPRA014-018DV 49


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVH16S18E6V + ETVH16S23E6V + ETVH16S18E6V + ETVH16S23E6V + ETVH16S18E6V + ETVH16S23E6V +
Technical specifications
EPRA14DV3 EPRA14DAV3 EPRA16DV3 EPRA16DAV3 EPRA18DV3 EPRA18DAV3
Domestic hot Average ηwh (water heating effi- % 110 108 110 108 110 108
2 water heating climate ciency)
Qelec (Daily electricity kWh 4.450 7.320 4.450 7.320 4.450 7.320
consumption)
Reference hot water tem- °C 52.5
perature
Stand-by power input W 34.2 49.2 34.2 49.2 34.2 49.2
Water heating energy efficiency class A
Cold AEC (Annual electricity kWh 1,091 1,814 1,091 1,814 1,091 1,814
climate consumption)
COPdhw 2.26 2.23 2.26 2.23 2.26 2.23
Heat up time 1h 04min 1h 16min 1h 04min 1h 16min 1h 04min 1h 16min
ηwh (water heating effi- % 94 92 94 92 94 92
ciency)
Qelec (Daily electricity kWh 5.170 8.560 5.170 8.560 5.170 8.560
consumption)
Reference hot water tem- °C 52.5
perature
Stand-by power input W 36.4 54.4 36.4 54.4 36.4 54.4
Warm AEC (Annual electricity kWh 843 1,388 843 1,388 843 1,388
climate consumption)
COPdhw 2.90
Heat up time 1h 15min 1h 30min 1h 15min 1h 30min 1h 15min 1h 30min
ηwh (water heating effi- % 122 121 122 121 122 121
ciency)
Qelec (Daily electricity kWh 4.020 6.570 4.020 6.570 4.020 6.570
consumption)
Reference hot water tem- °C 52.5
perature
Stand-by power input W 32.9 46.1 32.9 46.1 32.9 46.1
Space heating Average General Annual energy kWh 7,211
climate consumption
water ηs (Seasonal % 140
outlet space heating
55°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 26
gy consumption
(GCV)
SCOP 3.58
Seasonal space heating A++
eff. class
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.47
Pdh kW 11.2
PERd % 98.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.56
(2°CD- Pdh kW 6.9
B/1°CWB) PERd % 142.4
C Con- Cdh (Degradation heating) 1.0
dition COPd 4.44
(7°CD- Pdh kW 6.9
B/6°CWB) PERd % 177.6

50 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVH16S18E6V + ETVH16S23E6V + ETVH16S18E6V + ETVH16S23E6V + ETVH16S18E6V + ETVH16S23E6V +
Technical specifications
EPRA14DV3 EPRA14DAV3 EPRA16DV3 EPRA16DAV3 EPRA18DV3 EPRA18DAV3
Space heating Average D Condition Cdh (Degradation heating) 1.0
climate (12°CDB/11°CWB) COPd 5.72 2
water Pdh kW 6.2
outlet PERd % 228.8
55°C Tol (tem- COPd 2.19
perature Pdh kW 12.2
operat- PERd % 87.6
ing limit) TOL °C -10
WTOL °C 55
Rated Psup (at Tdesign kW 0.3
heat -10°C)
output
supple-
mentary
capacity
Tbiv COPd 2.19
(bivalent Pdh kW 12.2
tempera- PERd % 87.6
ture) Tbiv °C -10
Cold General Annual energy kWh 9,654
climate consumption
water ηs (Seasonal % 125
outlet space heating
55°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 35
gy consumption
(GCV)
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.74
Pdh kW 7.5
PERd % 109.6
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 5.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 4.69
(7°CD- Pdh kW 5.6
B/6°CWB) PERd % 187.6
D Condition COPd 6.12
(12°CDB/11°CWB) Pdh kW 6.2
PERd % 244.8
Tol (tem- COPd 1.65
perature Pdh kW 10.6
operat- PERd % 66.0
ing limit) TOL °C -22

Daikin Altherma high temperature split • EPRA014-018DV 51


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVH16S18E6V + ETVH16S23E6V + ETVH16S18E6V + ETVH16S23E6V + ETVH16S18E6V + ETVH16S23E6V +
Technical specifications
EPRA14DV3 EPRA14DAV3 EPRA16DV3 EPRA16DAV3 EPRA18DV3 EPRA18DAV3
Space heating Cold Tol (tem- WTOL °C 55
2 climate perature
water operat-
outlet ing limit)
55°C G Con- COPd 2.17
dition Pdh kW 10.3
(-15°CDB/- PERd % 86.8
)
Tbiv COPd 1.90
(bivalent Pdh kW 11.0
tempera- PERd % 76.0
ture) Tbiv °C -18
Rated Psup (at Tdesign kW 1.9
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 4,090
climate consumption
water ηs (Seasonal % 160
outlet space heating
55°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 15
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 2.45
(2°CD- Pdh kW 10.0
B/1°CWB) PERd % 98.0
C Con- Cdh (Degradation heating) 1.0
dition COPd 3.69
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 147.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.39
Pdh kW 5.9
PERd % 215.6
Tbiv COPd 3.27
(bivalent Pdh kW 9.9
tempera- PERd % 130.8
ture) Tbiv °C 5
Water H Condi- Max. kW 11.1 11.8
outlet tion (-2°C
45°C /-)
Average General Annual energy kWh 5,726
climate consumption
water ηs (Seasonal % 177
outlet space heating
35°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 21
gy consumption
(GCV)
SCOP 4.51
Seasonal space heating A+++
eff. class
A Condition COPd 3.12
(-7°CDB/-8°CWB)

52 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVH16S18E6V + ETVH16S23E6V + ETVH16S18E6V + ETVH16S23E6V + ETVH16S18E6V + ETVH16S23E6V +
Technical specifications
EPRA14DV3 EPRA14DAV3 EPRA16DV3 EPRA16DAV3 EPRA18DV3 EPRA18DAV3
Space heating Average A Condition Pdh kW 11.1
climate (-7°CDB/-8°CWB) PERd % 124.8 2
water B Con- Cdh (Degradation heating) 1.0
outlet dition COPd 4.44
35°C (2°CD- Pdh kW 6.7
B/1°CWB) PERd % 177.6
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.84
(7°CD- Pdh kW 5.7
B/6°CWB) PERd % 233.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.40
Pdh kW 6.0
PERd % 296.0
Tol (tem- COPd 2.76
perature Pdh kW 11.1
operat- PERd % 110.4
ing limit) TOL °C -10
WTOL °C 35
Tbiv COPd 3.12
(bivalent Pdh kW 11.1
tempera- PERd % 124.8
ture) Tbiv °C -7
Rated Psup (at Tdesign kW 1.4
heat -10°C)
output
supple-
mentary
capacity
Cold General Annual energy kWh 7,417
climate consumption
water ηs (Seasonal % 163
outlet space heating
35°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 27
gy consumption
(GCV)
A Condition COPd 3.50
(-7°CDB/-8°CWB) Pdh kW 8.0
PERd % 140.0
B Con- Cdh (Degradation heating) 1.0
dition COPd 5.07
(2°CD- Pdh kW 4.9
B/1°CWB) PERd % 202.8
C Condition Cdh (Degradation heating) 1.0
(7°CDB/6°CWB) COPd 6.10

Daikin Altherma high temperature split • EPRA014-018DV 53


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVH16S18E6V + ETVH16S23E6V + ETVH16S18E6V + ETVH16S23E6V + ETVH16S18E6V + ETVH16S23E6V +
Technical specifications
EPRA14DV3 EPRA14DAV3 EPRA16DV3 EPRA16DAV3 EPRA18DV3 EPRA18DAV3
Space heating Cold C Con- Pdh kW 5.3
2 climate dition PERd % 244.0
water (7°CD-
outlet B/6°CWB)
35°C D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.03
Pdh kW 5.7
PERd % 281.2
Tol (tem- COPd 2.16
perature Pdh kW 10.1
operat- PERd % 86.4
ing limit) TOL °C -22
WTOL °C 35
G Con- COPd 2.62
dition Pdh kW 10.7
(-15°CDB/- PERd % 104.8
)
Tbiv COPd 2.62
(bivalent Pdh kW 10.7
tempera- PERd % 104.8
ture) Tbiv °C -15
Rated Psup (at Tdesign kW 2.4
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 2,885
climate consumption
water ηs (Seasonal % 229
outlet space heating
35°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 10
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 9.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.60
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 224.0
Tbiv COPd 4.95
(bivalent Pdh kW 9.8
tempera- PERd % 198.0
ture) Tbiv °C 5
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.60
Space heating Warm D Condition Pdh kW 6.1
climate (12°CDB/11°CWB) PERd % 304.0
water
(1)Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C |
(2)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(3)Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 |
(4)Test at Ta DB/WB 7°C/6°C. According to EN 16147. |
(5)DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed |
Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB |
Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB

ETVH16S18E9W + ETVH16S23E9W + ETVH16S18E9W + ETVH16S23E9W + ETVH16S18E9W + ETVH16S23E9W +


Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Heating capacity Min. kW 3.70 (1) 3.96 (1) 4.40 (1)
Nom. kW 5.69 (2) 9.00 (2)
Max. kW 10.18 (1) 10.91 (1) 12.12 (1)
Power input Heating Min. kW 0.88 (3) 0.95 (3) 1.05 (3)
Nom. kW 1.22 (2) 1.80 (2)
Max. kW 2.09 (3) 2.24 (3) 2.49 (3)
Domestic Nom. kWh 2.57 (4) 2.85 (4) 2.57 (4) 2.85 (4) 2.57 (4) 2.85 (4)
hot water
from 10°C
to 50°C

54 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVH16S18E9W + ETVH16S23E9W + ETVH16S18E9W + ETVH16S23E9W + ETVH16S18E9W + ETVH16S23E9W +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Heat up time from 10°C to 50°C hr 1h02min at 1h13min at 1h02min at 1h13min at 1h02min at 1h13min at
7°C ambient 7°C ambient 7°C ambient 7°C ambient 7°C ambient 7°C ambient 2
temperature temperature temperature temperature temperature temperature
COP 4.67 (2) 5.00 (2)
Pump Type Grundfos UPMXL GEO 25-125 130 PWM
Nominal Heating kPa 111.2 (5) 97.4 (5)
ESP unit
Water side Heat Water Heating Nom. l/min 16.3 (2) 25.8 (2)
exchanger flow rate
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manu- Name or trademark Daikin Europe N.V.
facturer
details
Product Air-to-water heat pump Yes
descrip- Brine-to-water heat pump No
tion Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated Yes
Water-to-water heat pump No
LW(A) SoundIndoor dB(A) 44.0
power level
(according to
EN14825)
LW(A) Sound pow- Outdoor dB(A) 54.0
er level (according
to EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Tank Name Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel
domestic hot domestic hot domestic hot domestic hot domestic hot domestic hot
water tank 180 l water tank 230 L water tank 180 l water tank 230 L water tank 180 l water tank 230 L
Space heating Air to Rated airflow (outdoor) m³/h 3,918 3,960
general water
unit
Other Capacity control Inverter
Pck (Crankcase heater mode) kW 0.000
Poff (Off mode) kW 0.021
Psb (Standby mode) kW 0.021
Pto (Thermostat off) kW 0.041
Domestic hot General Declared load profile L XL L XL L XL
water heating

Space heating Inte- Psup kW 9.0


general grated Type of energy input Electrical
supple-
mentary
heater
Domestic hot Average AEC (Annual electricity kWh 935 1,547 935 1,547 935 1,547
water heating climate consumption)
COPdhw 2.62 2.61 2.62 2.61 2.62 2.61
Heat up time 1h 06min 1h 19min 1h 06min 1h 19min 1h 06min 1h 19min

Daikin Altherma high temperature split • EPRA014-018DV 55


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVH16S18E9W + ETVH16S23E9W + ETVH16S18E9W + ETVH16S23E9W + ETVH16S18E9W + ETVH16S23E9W +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Domestic hot Average ηwh (water heating effi- % 110 108 110 108 110 108
2 water heating climate ciency)
Qelec (Daily electricity kWh 4.450 7.320 4.450 7.320 4.450 7.320
consumption)
Reference hot water tem- °C 52.5
perature
Stand-by power input W 34.2 49.2 34.2 49.2 34.2 49.2
Water heating energy efficiency class A
Cold AEC (Annual electricity kWh 1,091 1,814 1,091 1,814 1,091 1,814
climate consumption)
COPdhw 2.26 2.23 2.26 2.23 2.26 2.23
Heat up time 1h 04min 1h 16min 1h 04min 1h 16min 1h 04min 1h 16min
ηwh (water heating effi- % 94 92 94 92 94 92
ciency)
Qelec (Daily electricity kWh 5.170 8.560 5.170 8.560 5.170 8.560
consumption)
Reference hot water tem- °C 52.5
perature
Stand-by power input W 36.4 54.4 36.4 54.4 36.4 54.4
Warm AEC (Annual electricity kWh 843 1,388 843 1,388 843 1,388
climate consumption)
COPdhw 2.90
Heat up time 1h 15min 1h 30min 1h 15min 1h 30min 1h 15min 1h 30min
ηwh (water heating effi- % 122 121 122 121 122 121
ciency)
Qelec (Daily electricity kWh 4.020 6.570 4.020 6.570 4.020 6.570
consumption)
Reference hot water tem- °C 52.5
perature
Stand-by power input W 32.9 46.1 32.9 46.1 32.9 46.1
Space heating Average General Annual energy kWh 7,211
climate consumption
water ηs (Seasonal % 140
outlet space heating
55°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 26
gy consumption
(GCV)
SCOP 3.58
Seasonal space heating A++
eff. class
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.47
Pdh kW 11.2
PERd % 98.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.56
(2°CD- Pdh kW 6.9
B/1°CWB) PERd % 142.4
C Con- Cdh (Degradation heating) 1.0
dition COPd 4.44
(7°CD- Pdh kW 6.9
B/6°CWB) PERd % 177.6

56 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVH16S18E9W + ETVH16S23E9W + ETVH16S18E9W + ETVH16S23E9W + ETVH16S18E9W + ETVH16S23E9W +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Average D Condition Cdh (Degradation heating) 1.0
climate (12°CDB/11°CWB) COPd 5.72 2
water Pdh kW 6.2
outlet PERd % 228.8
55°C Tol (tem- COPd 2.19
perature Pdh kW 12.2
operat- PERd % 87.6
ing limit) TOL °C -10
WTOL °C 55
Rated Psup (at Tdesign kW 0.3
heat -10°C)
output
supple-
mentary
capacity
Tbiv COPd 2.19
(bivalent Pdh kW 12.2
tempera- PERd % 87.6
ture) Tbiv °C -10
Cold General Annual energy kWh 9,654
climate consumption
water ηs (Seasonal % 125
outlet space heating
55°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 35
gy consumption
(GCV)
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.74
Pdh kW 7.5
PERd % 109.6
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 5.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 4.69
(7°CD- Pdh kW 5.6
B/6°CWB) PERd % 187.6
D Condition COPd 6.12
(12°CDB/11°CWB) Pdh kW 6.2
PERd % 244.8
Tol (tem- COPd 1.65
perature Pdh kW 10.6
operat- PERd % 66.0
ing limit) TOL °C -22

Daikin Altherma high temperature split • EPRA014-018DV 57


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVH16S18E9W + ETVH16S23E9W + ETVH16S18E9W + ETVH16S23E9W + ETVH16S18E9W + ETVH16S23E9W +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Cold Tol (tem- WTOL °C 55
2 climate perature
water operat-
outlet ing limit)
55°C G Con- COPd 2.17
dition Pdh kW 10.3
(-15°CDB/- PERd % 86.8
)
Tbiv COPd 1.90
(bivalent Pdh kW 11.0
tempera- PERd % 76.0
ture) Tbiv °C -18
Rated Psup (at Tdesign kW 1.9
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 4,090
climate consumption
water ηs (Seasonal % 160
outlet space heating
55°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 15
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 2.45
(2°CD- Pdh kW 10.0
B/1°CWB) PERd % 98.0
C Con- Cdh (Degradation heating) 1.0
dition COPd 3.69
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 147.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.39
Pdh kW 5.9
PERd % 215.6
Tbiv COPd 3.27
(bivalent Pdh kW 9.9
tempera- PERd % 130.8
ture) Tbiv °C 5
Water H Condi- Max. kW 11.1 11.8
outlet tion (-2°C
45°C /-)
Average General Annual energy kWh 5,726
climate consumption
water ηs (Seasonal % 177
outlet space heating
35°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 21
gy consumption
(GCV)
SCOP 4.51
Seasonal space heating A+++
eff. class
A Condition COPd 3.12
(-7°CDB/-8°CWB)

58 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVH16S18E9W + ETVH16S23E9W + ETVH16S18E9W + ETVH16S23E9W + ETVH16S18E9W + ETVH16S23E9W +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Average A Condition Pdh kW 11.1
climate (-7°CDB/-8°CWB) PERd % 124.8 2
water B Con- Cdh (Degradation heating) 1.0
outlet dition COPd 4.44
35°C (2°CD- Pdh kW 6.7
B/1°CWB) PERd % 177.6
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.84
(7°CD- Pdh kW 5.7
B/6°CWB) PERd % 233.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.40
Pdh kW 6.0
PERd % 296.0
Tol (tem- COPd 2.76
perature Pdh kW 11.1
operat- PERd % 110.4
ing limit) TOL °C -10
WTOL °C 35
Tbiv COPd 3.12
(bivalent Pdh kW 11.1
tempera- PERd % 124.8
ture) Tbiv °C -7
Rated Psup (at Tdesign kW 1.4
heat -10°C)
output
supple-
mentary
capacity
Cold General Annual energy kWh 7,417
climate consumption
water ηs (Seasonal % 163
outlet space heating
35°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 27
gy consumption
(GCV)
A Condition COPd 3.50
(-7°CDB/-8°CWB) Pdh kW 8.0
PERd % 140.0
B Con- Cdh (Degradation heating) 1.0
dition COPd 5.07
(2°CD- Pdh kW 4.9
B/1°CWB) PERd % 202.8
C Condition Cdh (Degradation heating) 1.0
(7°CDB/6°CWB) COPd 6.10

Daikin Altherma high temperature split • EPRA014-018DV 59


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVH16S18E9W + ETVH16S23E9W + ETVH16S18E9W + ETVH16S23E9W + ETVH16S18E9W + ETVH16S23E9W +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Cold C Con- Pdh kW 5.3
2 climate dition PERd % 244.0
water (7°CD-
outlet B/6°CWB)
35°C D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.03
Pdh kW 5.7
PERd % 281.2
Tol (tem- COPd 2.16
perature Pdh kW 10.1
operat- PERd % 86.4
ing limit) TOL °C -22
WTOL °C 35
G Con- COPd 2.62
dition Pdh kW 10.7
(-15°CDB/- PERd % 104.8
)
Tbiv COPd 2.62
(bivalent Pdh kW 10.7
tempera- PERd % 104.8
ture) Tbiv °C -15
Rated Psup (at Tdesign kW 2.4
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 2,885
climate consumption
water ηs (Seasonal % 229
outlet space heating
35°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 10
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 9.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.60
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 224.0
Tbiv COPd 4.95
(bivalent Pdh kW 9.8
tempera- PERd % 198.0
ture) Tbiv °C 5
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.60
Space heating Warm D Condition Pdh kW 6.1
climate (12°CDB/11°CWB) PERd % 304.0
water
(1)Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C |
(2)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(3)Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 |
(4)Test at Ta DB/WB 7°C/6°C. According to EN 16147. |
(5)DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed |
Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB |
Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB

ETVX16S18E6V + ETVX16S23E6V + ETVX16S18E6V + ETVX16S23E6V + ETVX16S18E6V + ETVX16S23E6V +


Technical specifications EPRA14DAV3 EPRA16DAV3 EPRA18DAV3
EPRA14DV3 EPRA16DV3 EPRA18DV3
Heating capacity Min. kW 3.70 (1) 3.96 (1) 4.40 (1)
Nom. kW 5.69 (2) 9.00 (2)
Max. kW 10.18 (1) 10.91 (1) 12.12 (1)
Cooling capacity Nom. kW 10.6 (3) / 6.90 (4) 11.5 (3) / 7.88 (4) 12.5 (3) / 8.86 (4)

60 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVX16S18E6V + ETVX16S23E6V + ETVX16S18E6V + ETVX16S23E6V + ETVX16S18E6V + ETVX16S23E6V +
Technical specifications
EPRA14DAV3 EPRA14DV3 EPRA16DAV3 EPRA16DV3 EPRA18DAV3 EPRA18DV3
Power input Heating Min. kW 0.88 (5) 0.95 (5) 1.05 (5)
Nom. kW 1.22 (2) 1.80 (2) 2
Max. kW 2.09 (5) 2.24 (5) 2.49 (5)
Cooling Nom. kW 2.55 (3) / 2.56 (4) 2.80 (3) / 2.93 (4) 3.05 (3) / 3.31 (4)
Domestic Nom. kWh 2.57 (6) 2.85 (6) 2.57 (6) 2.85 (6) 2.57 (6) 2.85 (6)
hot water
from 10°C
to 50°C
Heat up time from 10°C to 50°C hr 1h02min at 1h13min at 1h02min at 1h13min at 1h02min at 1h13min at
7°C ambient 7°C ambient 7°C ambient 7°C ambient 7°C ambient 7°C ambient
temperature temperature temperature temperature temperature temperature
COP 4.67 (2) 5.00 (2)
EER 4.13 (3) / 2.70 (4) 4.11 (3) / 2.69 (4) 4.09 (3) / 2.68 (4)
Pump Type Grundfos UPMXL GEO 25-125 130 PWM
Nominal Heating kPa 111.2 (7) 97.4 (7)
ESP unit
Water side Heat Water Heating Nom. l/min 16.3 (2) 25.8 (2)
exchanger flow rate
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manu- Name or trademark Daikin Europe N.V.
facturer
details
Product Air-to-water heat pump Yes
descrip- Brine-to-water heat pump No
tion Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated Yes
Water-to-water heat pump No
LW(A) SoundIndoor dB(A) 44.0
power level
(according to
EN14825)
LW(A) Sound pow- Outdoor dB(A) 54.0
er level (according
to EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Tank Name Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel
domestic hot domestic hot domestic hot domestic hot domestic hot domestic hot
water tank 180 l water tank 230 L water tank 180 l water tank 230 L water tank 180 l water tank 230 L
Space heating Air to Rated airflow (outdoor) m³/h 3,918 3,960
general water
unit
Other Capacity control Inverter
Pck (Crankcase heater mode) kW 0.000
Poff (Off mode) kW 0.021
Psb (Standby mode) kW 0.021
Pto (Thermostat off) kW 0.041
Domestic hot General Declared load profile L XL L XL L XL
water heating

Space heating Inte- Psup kW 6.0


general grated Type of energy input Electrical
supple-
mentary
heater

Daikin Altherma high temperature split • EPRA014-018DV 61


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVX16S18E6V + ETVX16S23E6V + ETVX16S18E6V + ETVX16S23E6V + ETVX16S18E6V + ETVX16S23E6V +
Technical specifications
EPRA14DAV3 EPRA14DV3 EPRA16DAV3 EPRA16DV3 EPRA18DAV3 EPRA18DV3
Domestic hot Average AEC (Annual electricity kWh 935 1,547 935 1,547 935 1,547
2 water heating climate consumption)
COPdhw 2.62 2.61 2.62 2.61 2.62 2.61
Heat up time 1h 06min 1h 19min 1h 06min 1h 19min 1h 06min 1h 19min
ηwh (water heating effi- % 110 108 110 108 110 108
ciency)
Qelec (Daily electricity kWh 4.450 7.320 4.450 7.320 4.450 7.320
consumption)
Reference hot water tem- °C 52.5
perature
Stand-by power input W 34.2 49.2 34.2 49.2 34.2 49.2
Water heating energy efficiency class A
Cold AEC (Annual electricity kWh 1,091 1,814 1,091 1,814 1,091 1,814
climate consumption)
COPdhw 2.26 2.23 2.26 2.23 2.26 2.23
Heat up time 1h 04min 1h 16min 1h 04min 1h 16min 1h 04min 1h 16min
ηwh (water heating effi- % 94 92 94 92 94 92
ciency)
Qelec (Daily electricity kWh 5.170 8.560 5.170 8.560 5.170 8.560
consumption)
Reference hot water tem- °C 52.5
perature
Stand-by power input W 36.4 54.4 36.4 54.4 36.4 54.4
Warm AEC (Annual electricity kWh 843 1,388 843 1,388 843 1,388
climate consumption)
COPdhw 2.90
Heat up time 1h 15min 1h 30min 1h 15min 1h 30min 1h 15min 1h 30min
ηwh (water heating effi- % 122 121 122 121 122 121
ciency)
Qelec (Daily electricity kWh 4.020 6.570 4.020 6.570 4.020 6.570
consumption)
Reference hot water tem- °C 52.5
perature
Stand-by power input W 32.9 46.1 32.9 46.1 32.9 46.1
Space heating Average General Annual energy kWh 7,134
climate consumption
water ηs (Seasonal % 142
outlet space heating
55°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 26
gy consumption
(GCV)
SCOP 3.62
Seasonal space heating A++
eff. class
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.47
Pdh kW 11.2
PERd % 98.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.56
(2°CD- Pdh kW 6.9
B/1°CWB) PERd % 142.4
C Con- Cdh (Degradation heating) 1.0
dition
(7°CD-
B/6°CWB)

62 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVX16S18E6V + ETVX16S23E6V + ETVX16S18E6V + ETVX16S23E6V + ETVX16S18E6V + ETVX16S23E6V +
Technical specifications
EPRA14DAV3 EPRA14DV3 EPRA16DAV3 EPRA16DV3 EPRA18DAV3 EPRA18DV3
Space heating Average C Con- COPd 4.44
climate dition Pdh kW 6.9 2
water (7°CD- PERd % 177.6
outlet B/6°CWB)
55°C D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.72
Pdh kW 6.2
PERd % 228.8
Tol (tem- COPd 2.19
perature Pdh kW 12.2
operat- PERd % 87.6
ing limit) TOL °C -10
WTOL °C 55
Rated Psup (at Tdesign kW 0.3
heat -10°C)
output
supple-
mentary
capacity
Tbiv COPd 2.19
(bivalent Pdh kW 12.2
tempera- PERd % 87.6
ture) Tbiv °C -10
Cold General Annual energy kWh 9,609
climate consumption
water ηs (Seasonal % 125
outlet space heating
55°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 35
gy consumption
(GCV)
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.74
Pdh kW 7.5
PERd % 109.6
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 5.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 4.69
(7°CD- Pdh kW 5.6
B/6°CWB) PERd % 187.6
D Condition COPd 6.12
(12°CDB/11°CWB) Pdh kW 6.2
PERd % 244.8
Tol (tem- COPd 1.65
perature
operat-
ing limit)

Daikin Altherma high temperature split • EPRA014-018DV 63


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVX16S18E6V + ETVX16S23E6V + ETVX16S18E6V + ETVX16S23E6V + ETVX16S18E6V + ETVX16S23E6V +
Technical specifications
EPRA14DAV3 EPRA14DV3 EPRA16DAV3 EPRA16DV3 EPRA18DAV3 EPRA18DV3
Space heating Cold Tol (tem- Pdh kW 10.6
2 climate perature PERd % 66.0
water operat- TOL °C -22
outlet ing limit) WTOL °C 55
55°C G Con- COPd 2.17
dition Pdh kW 10.3
(-15°CDB/- PERd % 86.8
)
Tbiv COPd 1.90
(bivalent Pdh kW 11.0
tempera- PERd % 76.0
ture) Tbiv °C -18
Rated Psup (at Tdesign kW 1.9
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 3,997
climate consumption
water ηs (Seasonal % 164
outlet space heating
55°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 14
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 2.45
(2°CD- Pdh kW 10.0
B/1°CWB) PERd % 98.0
C Con- Cdh (Degradation heating) 1.0
dition COPd 3.69
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 147.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.39
Pdh kW 5.9
PERd % 215.6
Tbiv COPd 3.27
(bivalent Pdh kW 9.9
tempera- PERd % 130.8
ture) Tbiv °C 5
Water H Condi- Max. kW 11.1 11.8
outlet tion (-2°C
45°C /-)
Average General Annual energy kWh 5,649
climate consumption
water ηs (Seasonal % 180
outlet space heating
35°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 20
gy consumption
(GCV)

64 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVX16S18E6V + ETVX16S23E6V + ETVX16S18E6V + ETVX16S23E6V + ETVX16S18E6V + ETVX16S23E6V +
Technical specifications
EPRA14DAV3 EPRA14DV3 EPRA16DAV3 EPRA16DV3 EPRA18DAV3 EPRA18DV3
Space heating Average General SCOP 4.57
climate Seasonal space heating A+++ 2
water eff. class
outlet A Condition COPd 3.12
35°C (-7°CDB/-8°CWB) Pdh kW 11.1
PERd % 124.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 4.44
(2°CD- Pdh kW 6.7
B/1°CWB) PERd % 177.6
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.84
(7°CD- Pdh kW 5.7
B/6°CWB) PERd % 233.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.40
Pdh kW 6.0
PERd % 296.0
Tol (tem- COPd 2.76
perature Pdh kW 11.1
operat- PERd % 110.4
ing limit) TOL °C -10
WTOL °C 35
Tbiv COPd 3.12
(bivalent Pdh kW 11.1
tempera- PERd % 124.8
ture) Tbiv °C -7
Rated Psup (at Tdesign kW 1.4
heat -10°C)
output
supple-
mentary
capacity
Cold General Annual energy kWh 7,370
climate consumption
water ηs (Seasonal % 164
outlet space heating
35°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 27
gy consumption
(GCV)
A Condition COPd 3.50
(-7°CDB/-8°CWB) Pdh kW 8.0
PERd % 140.0
B Condition Cdh (Degradation heating) 1.0
(2°CDB/1°CWB) COPd 5.07
Pdh kW 4.9

Daikin Altherma high temperature split • EPRA014-018DV 65


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVX16S18E6V + ETVX16S23E6V + ETVX16S18E6V + ETVX16S23E6V + ETVX16S18E6V + ETVX16S23E6V +
Technical specifications
EPRA14DAV3 EPRA14DV3 EPRA16DAV3 EPRA16DV3 EPRA18DAV3 EPRA18DV3
Space heating Cold B Con- PERd % 202.8
2 climate dition
water (2°CD-
outlet B/1°CWB)
35°C C Con- Cdh (Degradation heating) 1.0
dition COPd 6.10
(7°CD- Pdh kW 5.3
B/6°CWB) PERd % 244.0
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.03
Pdh kW 5.7
PERd % 281.2
Tol (tem- COPd 2.16
perature Pdh kW 10.1
operat- PERd % 86.4
ing limit) TOL °C -22
WTOL °C 35
G Con- COPd 2.62
dition Pdh kW 10.7
(-15°CDB/- PERd % 104.8
)
Tbiv COPd 2.62
(bivalent Pdh kW 10.7
tempera- PERd % 104.8
ture) Tbiv °C -15
Rated Psup (at Tdesign kW 2.4
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 2,792
climate consumption
water ηs (Seasonal % 236
outlet space heating
35°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 10
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 9.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.60
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 224.0
Tbiv COPd 4.95
(bivalent Pdh kW 9.8
tempera- PERd % 198.0
Space heating Warm Tbiv Tbiv °C 5
climate (bivalent
water tempera-
outlet ture)
35°C D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.60
Pdh kW 6.1
PERd % 304.0
(1)Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C |
(2)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(3)Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB |
(4)Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB |
(5)Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 |
(6)Test at Ta DB/WB 7°C/6°C. According to EN 16147. |
(7)DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed

ETVX16S18E9W + ETVX16S23E9W + ETVX16S18E9W + ETVX16S23E9W + ETVX16S18E9W + ETVX16S23E9W +


Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Heating capacity Min. kW 3.70 (1) 3.96 (1) 4.40 (1)
Nom. kW 5.69 (2) 9.00 (2)
Max. kW 10.18 (1) 10.91 (1) 12.12 (1)
Cooling capacity Nom. kW 10.6 (3) / 6.90 (4) 11.5 (3) / 7.88 (4) 12.5 (3) / 8.86 (4)

66 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVX16S18E9W + ETVX16S23E9W + ETVX16S18E9W + ETVX16S23E9W + ETVX16S18E9W + ETVX16S23E9W +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Power input Heating Min. kW 0.88 (5) 0.95 (5) 1.05 (5)
Nom. kW 1.22 (2) 1.80 (2) 2
Max. kW 2.09 (5) 2.24 (5) 2.49 (5)
Cooling Nom. kW 2.55 (3) / 2.56 (4) 2.80 (3) / 2.93 (4) 3.05 (3) / 3.31 (4)
Domestic Nom. kWh 2.57 (6) 2.85 (6) 2.57 (6) 2.85 (6) 2.57 (6) 2.85 (6)
hot water
from 10°C
to 50°C
Heat up time from 10°C to 50°C hr 1h02min at 1h13min at 1h02min at 1h13min at 1h02min at 1h13min at
7°C ambient 7°C ambient 7°C ambient 7°C ambient 7°C ambient 7°C ambient
temperature temperature temperature temperature temperature temperature
COP 4.67 (2) 5.00 (2)
EER 4.13 (3) / 2.70 (4) 4.11 (3) / 2.69 (4) 4.09 (3) / 2.68 (4)
Pump Type Grundfos UPMXL GEO 25-125 130 PWM
Nominal Heating kPa 111.2 (7) 97.4 (7)
ESP unit
Water side Heat Water Heating Nom. l/min 16.3 (2) 25.8 (2)
exchanger flow rate
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manu- Name or trademark Daikin Europe N.V.
facturer
details
Product Air-to-water heat pump Yes
descrip- Brine-to-water heat pump No
tion Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated Yes
Water-to-water heat pump No
LW(A) SoundIndoor dB(A) 44.0
power level
(according to
EN14825)
LW(A) Sound pow- Outdoor dB(A) 54.0
er level (according
to EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Tank Name Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel
domestic hot domestic hot domestic hot domestic hot domestic hot domestic hot
water tank 180 l water tank 230 L water tank 180 l water tank 230 L water tank 180 l water tank 230 L
Space heating Air to Rated airflow (outdoor) m³/h 3,918 3,960
general water
unit
Other Capacity control Inverter
Pck (Crankcase heater mode) kW 0.000
Poff (Off mode) kW 0.021
Psb (Standby mode) kW 0.021
Pto (Thermostat off) kW 0.041
Domestic hot General Declared load profile L XL L XL L XL
water heating

Space heating Inte- Psup kW 9.0


general grated Type of energy input Electrical
supple-
mentary
heater

Daikin Altherma high temperature split • EPRA014-018DV 67


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVX16S18E9W + ETVX16S23E9W + ETVX16S18E9W + ETVX16S23E9W + ETVX16S18E9W + ETVX16S23E9W +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Domestic hot Average AEC (Annual electricity kWh 935 1,547 935 1,547 935 1,547
2 water heating climate consumption)
COPdhw 2.62 2.61 2.62 2.61 2.62 2.61
Heat up time 1h 06min 1h 19min 1h 06min 1h 19min 1h 06min 1h 19min
ηwh (water heating effi- % 110 108 110 108 110 108
ciency)
Qelec (Daily electricity kWh 4.450 7.320 4.450 7.320 4.450 7.320
consumption)
Reference hot water tem- °C 52.5
perature
Stand-by power input W 34.2 49.2 34.2 49.2 34.2 49.2
Water heating energy efficiency class A
Cold AEC (Annual electricity kWh 1,091 1,814 1,091 1,814 1,091 1,814
climate consumption)
COPdhw 2.26 2.23 2.26 2.23 2.26 2.23
Heat up time 1h 04min 1h 16min 1h 04min 1h 16min 1h 04min 1h 16min
ηwh (water heating effi- % 94 92 94 92 94 92
ciency)
Qelec (Daily electricity kWh 5.170 8.560 5.170 8.560 5.170 8.560
consumption)
Reference hot water tem- °C 52.5
perature
Stand-by power input W 36.4 54.4 36.4 54.4 36.4 54.4
Warm AEC (Annual electricity kWh 843 1,388 843 1,388 843 1,388
climate consumption)
COPdhw 2.90
Heat up time 1h 15min 1h 30min 1h 15min 1h 30min 1h 15min 1h 30min
ηwh (water heating effi- % 122 121 122 121 122 121
ciency)
Qelec (Daily electricity kWh 4.020 6.570 4.020 6.570 4.020 6.570
consumption)
Reference hot water tem- °C 52.5
perature
Stand-by power input W 32.9 46.1 32.9 46.1 32.9 46.1
Space heating Average General Annual energy kWh 7,134
climate consumption
water ηs (Seasonal % 142
outlet space heating
55°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 26
gy consumption
(GCV)
SCOP 3.62
Seasonal space heating A++
eff. class
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.47
Pdh kW 11.2
PERd % 98.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.56
(2°CD- Pdh kW 6.9
B/1°CWB) PERd % 142.4
C Con- Cdh (Degradation heating) 1.0
dition
(7°CD-
B/6°CWB)

68 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVX16S18E9W + ETVX16S23E9W + ETVX16S18E9W + ETVX16S23E9W + ETVX16S18E9W + ETVX16S23E9W +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Average C Con- COPd 4.44
climate dition Pdh kW 6.9 2
water (7°CD- PERd % 177.6
outlet B/6°CWB)
55°C D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.72
Pdh kW 6.2
PERd % 228.8
Tol (tem- COPd 2.19
perature Pdh kW 12.2
operat- PERd % 87.6
ing limit) TOL °C -10
WTOL °C 55
Rated Psup (at Tdesign kW 0.3
heat -10°C)
output
supple-
mentary
capacity
Tbiv COPd 2.19
(bivalent Pdh kW 12.2
tempera- PERd % 87.6
ture) Tbiv °C -10
Cold General Annual energy kWh 9,609
climate consumption
water ηs (Seasonal % 125
outlet space heating
55°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 35
gy consumption
(GCV)
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.74
Pdh kW 7.5
PERd % 109.6
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 5.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 4.69
(7°CD- Pdh kW 5.6
B/6°CWB) PERd % 187.6
D Condition COPd 6.12
(12°CDB/11°CWB) Pdh kW 6.2
PERd % 244.8
Tol (tem- COPd 1.65
perature
operat-
ing limit)

Daikin Altherma high temperature split • EPRA014-018DV 69


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVX16S18E9W + ETVX16S23E9W + ETVX16S18E9W + ETVX16S23E9W + ETVX16S18E9W + ETVX16S23E9W +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Cold Tol (tem- Pdh kW 10.6
2 climate perature PERd % 66.0
water operat- TOL °C -22
outlet ing limit) WTOL °C 55
55°C G Con- COPd 2.17
dition Pdh kW 10.3
(-15°CDB/- PERd % 86.8
)
Tbiv COPd 1.90
(bivalent Pdh kW 11.0
tempera- PERd % 76.0
ture) Tbiv °C -18
Rated Psup (at Tdesign kW 1.9
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 3,997
climate consumption
water ηs (Seasonal % 164
outlet space heating
55°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 14
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 2.45
(2°CD- Pdh kW 10.0
B/1°CWB) PERd % 98.0
C Con- Cdh (Degradation heating) 1.0
dition COPd 3.69
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 147.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.39
Pdh kW 5.9
PERd % 215.6
Tbiv COPd 3.27
(bivalent Pdh kW 9.9
tempera- PERd % 130.8
ture) Tbiv °C 5
Water H Condi- Max. kW 11.1 11.8
outlet tion (-2°C
45°C /-)
Average General Annual energy kWh 5,649
climate consumption
water ηs (Seasonal % 180
outlet space heating
35°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 20
gy consumption
(GCV)

70 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVX16S18E9W + ETVX16S23E9W + ETVX16S18E9W + ETVX16S23E9W + ETVX16S18E9W + ETVX16S23E9W +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Average General SCOP 4.57
climate Seasonal space heating A+++ 2
water eff. class
outlet A Condition COPd 3.12
35°C (-7°CDB/-8°CWB) Pdh kW 11.1
PERd % 124.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 4.44
(2°CD- Pdh kW 6.7
B/1°CWB) PERd % 177.6
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.84
(7°CD- Pdh kW 5.7
B/6°CWB) PERd % 233.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.40
Pdh kW 6.0
PERd % 296.0
Tol (tem- COPd 2.76
perature Pdh kW 11.1
operat- PERd % 110.4
ing limit) TOL °C -10
WTOL °C 35
Tbiv COPd 3.12
(bivalent Pdh kW 11.1
tempera- PERd % 124.8
ture) Tbiv °C -7
Rated Psup (at Tdesign kW 1.4
heat -10°C)
output
supple-
mentary
capacity
Cold General Annual energy kWh 7,370
climate consumption
water ηs (Seasonal % 164
outlet space heating
35°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 27
gy consumption
(GCV)
A Condition COPd 3.50
(-7°CDB/-8°CWB) Pdh kW 8.0
PERd % 140.0
B Condition Cdh (Degradation heating) 1.0
(2°CDB/1°CWB) COPd 5.07
Pdh kW 4.9

Daikin Altherma high temperature split • EPRA014-018DV 71


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVX16S18E9W + ETVX16S23E9W + ETVX16S18E9W + ETVX16S23E9W + ETVX16S18E9W + ETVX16S23E9W +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Cold B Con- PERd % 202.8
2 climate dition
water (2°CD-
outlet B/1°CWB)
35°C C Con- Cdh (Degradation heating) 1.0
dition COPd 6.10
(7°CD- Pdh kW 5.3
B/6°CWB) PERd % 244.0
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.03
Pdh kW 5.7
PERd % 281.2
Tol (tem- COPd 2.16
perature Pdh kW 10.1
operat- PERd % 86.4
ing limit) TOL °C -22
WTOL °C 35
G Con- COPd 2.62
dition Pdh kW 10.7
(-15°CDB/- PERd % 104.8
)
Tbiv COPd 2.62
(bivalent Pdh kW 10.7
tempera- PERd % 104.8
ture) Tbiv °C -15
Rated Psup (at Tdesign kW 2.4
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 2,792
climate consumption
water ηs (Seasonal % 236
outlet space heating
35°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 10
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 9.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.60
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 224.0
Tbiv COPd 4.95
(bivalent Pdh kW 9.8
tempera- PERd % 198.0
Space heating Warm Tbiv Tbiv °C 5
climate (bivalent
water tempera-
outlet ture)
35°C D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.60
Pdh kW 6.1
PERd % 304.0
(1)Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C |
(2)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(3)Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB |
(4)Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB |
(5)Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 |
(6)Test at Ta DB/WB 7°C/6°C. According to EN 16147. |
(7)DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed

ETVZ16S18E6V + ETVZ16S23E6V + ETVZ16S18E6V + ETVZ16S23E6V + ETVZ16S18E6V + ETVZ16S23E6V +


Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Heating capacity Min. kW 3.70 (1) 3.96 (1) 4.40 (1)
Nom. kW 5.69 (2) 9.00 (2)
Max. kW 10.18 (1) 10.91 (1) 12.12 (1)
Cooling capacity Nom. kW 10.6 (3) / 6.90 (4) - 11.5 (3) / 7.88 (4) - 12.5 (3) / 8.86 (4) -

72 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVZ16S18E6V + ETVZ16S23E6V + ETVZ16S18E6V + ETVZ16S23E6V + ETVZ16S18E6V + ETVZ16S23E6V +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Power input Heating Min. kW 0.88 (5) 0.95 (5) 1.05 (5)
Nom. kW 1.22 (2) 1.80 (2) 2
Max. kW 2.09 (5) 2.24 (5) 2.49 (5)
Domestic Nom. kWh 2.57 (6) 2.85 (6) 2.57 (6) 2.85 (6) 2.57 (6) 2.85 (6)
hot water
from 10°C
to 50°C
Heat up time from 10°C to 50°C hr 1h02min at 1h13min at 1h02min at 1h13min at 1h02min at 1h13min at
7°C ambient 7°C ambient 7°C ambient 7°C ambient 7°C ambient 7°C ambient
temperature temperature temperature temperature temperature temperature
COP 4.67 (2) 5.00 (2)
Pump Type Grundfos UPML GEO 25-105 130 PWM
Pump Additional Nominal Heating kPa 97.6 (7) 84.1 (7)
Zone ESP unit
Pump Main Zone Nominal Heating kPa 90.2 (7) 80.0 (7)
ESP unit
Water side Heat Water Heating Nom. l/min 16.3 (2) 25.8 (2)
exchanger flow rate
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manu- Name or trademark Daikin Europe N.V.
facturer
details
Product Air-to-water heat pump Yes
descrip- Brine-to-water heat pump No
tion Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated Yes
Water-to-water heat pump No
LW(A) SoundIndoor dB(A) 44.0
power level
(according to
EN14825)
LW(A) Sound pow- Outdoor dB(A) 54.0
er level (according
to EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Tank Name Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel
domestic hot domestic hot domestic hot domestic hot domestic hot domestic hot
water tank 180 l water tank 230 L water tank 180 l water tank 230 L water tank 180 l water tank 230 L
Space heating Air to Rated airflow (outdoor) m³/h 3,918 3,960
general water
unit
Other Capacity control Inverter
Pck (Crankcase heater mode) kW 0.000
Poff (Off mode) kW 0.021
Psb (Standby mode) kW 0.021
Pto (Thermostat off) kW 0.041
Domestic hot General Declared load profile L XL L XL L XL
water heating

Space heating Inte- Psup kW 6.0


general grated Type of energy input Electrical
supple-
mentary
heater
Domestic hot Average AEC (Annual electricity kWh 935 1,547 935 1,547 935 1,547
water heating climate consumption)

Daikin Altherma high temperature split • EPRA014-018DV 73


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVZ16S18E6V + ETVZ16S23E6V + ETVZ16S18E6V + ETVZ16S23E6V + ETVZ16S18E6V + ETVZ16S23E6V +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Domestic hot Average COPdhw 2.62 2.61 2.62 2.61 2.62 2.61
2 water heating climate Heat up time 1h 06min 1h 19min 1h 06min 1h 19min 1h 06min 1h 19min
ηwh (water heating effi- % 110 108 110 108 110 108
ciency)
Qelec (Daily electricity kWh 4.450 7.320 4.450 7.320 4.450 7.320
consumption)
Reference hot water tem- °C 52.5
perature
Stand-by power input W 34.2 49.2 34.2 49.2 34.2 49.2
Water heating energy efficiency class A
Cold AEC (Annual electricity kWh 1,091 1,814 1,091 1,814 1,091 1,814
climate consumption)
COPdhw 2.26 2.23 2.26 2.23 2.26 2.23
Heat up time 1h 04min 1h 16min 1h 04min 1h 16min 1h 04min 1h 16min
ηwh (water heating effi- % 94 92 94 92 94 92
ciency)
Qelec (Daily electricity kWh 5.170 8.560 5.170 8.560 5.170 8.560
consumption)
Reference hot water tem- °C 52.5
perature
Stand-by power input W 36.4 54.4 36.4 54.4 36.4 54.4
Warm AEC (Annual electricity kWh 843 1,388 843 1,388 843 1,388
climate consumption)
COPdhw 2.90
Heat up time 1h 15min 1h 30min 1h 15min 1h 30min 1h 15min 1h 30min
ηwh (water heating effi- % 122 121 122 121 122 121
ciency)
Qelec (Daily electricity kWh 4.020 6.570 4.020 6.570 4.020 6.570
consumption)
Reference hot water tem- °C 52.5
perature
Stand-by power input W 32.9 46.1 32.9 46.1 32.9 46.1
Space heating Average General Annual energy kWh 7,211
climate consumption
water ηs (Seasonal % 140
outlet space heating
55°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 26
gy consumption
(GCV)
SCOP 3.58
Seasonal space heating A++
eff. class
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.47
Pdh kW 11.2
PERd % 98.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.56
(2°CD- Pdh kW 6.9
B/1°CWB) PERd % 142.4
C Condition Cdh (Degradation heating) 1.0
(7°CDB/6°CWB) COPd 4.44

74 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVZ16S18E6V + ETVZ16S23E6V + ETVZ16S18E6V + ETVZ16S23E6V + ETVZ16S18E6V + ETVZ16S23E6V +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Average C Con- Pdh kW 6.9
climate dition PERd % 177.6 2
water (7°CD-
outlet B/6°CWB)
55°C D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.72
Pdh kW 6.2
PERd % 228.8
Tol (tem- COPd 2.19
perature Pdh kW 12.2
operat- PERd % 87.6
ing limit) TOL °C -10
WTOL °C 55
Rated Psup (at Tdesign kW 0.3
heat -10°C)
output
supple-
mentary
capacity
Tbiv COPd 2.19
(bivalent Pdh kW 12.2
tempera- PERd % 87.6
ture) Tbiv °C -10
Cold General Annual energy kWh 9,654
climate consumption
water ηs (Seasonal % 125
outlet space heating
55°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 35
gy consumption
(GCV)
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.74
Pdh kW 7.5
PERd % 109.6
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 5.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 4.69
(7°CD- Pdh kW 5.6
B/6°CWB) PERd % 187.6
D Condition COPd 6.12
(12°CDB/11°CWB) Pdh kW 6.2
PERd % 244.8
Tol (tempera- COPd 1.65
ture operating Pdh kW 10.6
limit)

Daikin Altherma high temperature split • EPRA014-018DV 75


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVZ16S18E6V + ETVZ16S23E6V + ETVZ16S18E6V + ETVZ16S23E6V + ETVZ16S18E6V + ETVZ16S23E6V +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Cold Tol (tem- PERd % 66.0
2 climate perature TOL °C -22
water operat- WTOL °C 55
outlet ing limit)
55°C G Con- COPd 2.17
dition Pdh kW 10.3
(-15°CDB/- PERd % 86.8
)
Tbiv COPd 1.90
(bivalent Pdh kW 11.0
tempera- PERd % 76.0
ture) Tbiv °C -18
Rated Psup (at Tdesign kW 1.9
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 4,090
climate consumption
water ηs (Seasonal % 160
outlet space heating
55°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 15
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 2.45
(2°CD- Pdh kW 10.0
B/1°CWB) PERd % 98.0
C Con- Cdh (Degradation heating) 1.0
dition COPd 3.69
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 147.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.39
Pdh kW 5.9
PERd % 215.6
Tbiv COPd 3.27
(bivalent Pdh kW 9.9
tempera- PERd % 130.8
ture) Tbiv °C 5
Water H Condi- Max. kW 11.1 11.8
outlet tion (-2°C
45°C /-)
Average General Annual energy kWh 5,726
climate consumption
water ηs (Seasonal % 177
outlet space heating
35°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 21
gy consumption
(GCV)
SCOP 4.51

76 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVZ16S18E6V + ETVZ16S23E6V + ETVZ16S18E6V + ETVZ16S23E6V + ETVZ16S18E6V + ETVZ16S23E6V +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Average General Seasonal space heating A+++
climate eff. class 2
water A Condition COPd 3.12
outlet (-7°CDB/-8°CWB) Pdh kW 11.1
35°C PERd % 124.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 4.44
(2°CD- Pdh kW 6.7
B/1°CWB) PERd % 177.6
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.84
(7°CD- Pdh kW 5.7
B/6°CWB) PERd % 233.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.40
Pdh kW 6.0
PERd % 296.0
Tol (tem- COPd 2.76
perature Pdh kW 11.1
operat- PERd % 110.4
ing limit) TOL °C -10
WTOL °C 35
Tbiv COPd 3.12
(bivalent Pdh kW 11.1
tempera- PERd % 124.8
ture) Tbiv °C -7
Rated Psup (at Tdesign kW 1.4
heat -10°C)
output
supple-
mentary
capacity
Cold General Annual energy kWh 7,417
climate consumption
water ηs (Seasonal % 163
outlet space heating
35°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 27
gy consumption
(GCV)
A Condition COPd 3.50
(-7°CDB/-8°CWB) Pdh kW 8.0
PERd % 140.0
B Con- Cdh (Degradation heating) 1.0
dition COPd 5.07
(2°CD- Pdh kW 4.9
B/1°CWB) PERd % 202.8

Daikin Altherma high temperature split • EPRA014-018DV 77


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVZ16S18E6V + ETVZ16S23E6V + ETVZ16S18E6V + ETVZ16S23E6V + ETVZ16S18E6V + ETVZ16S23E6V +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Cold C Con- Cdh (Degradation heating) 1.0
2 climate dition COPd 6.10
water (7°CD- Pdh kW 5.3
outlet B/6°CWB) PERd % 244.0
35°C D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.03
Pdh kW 5.7
PERd % 281.2
Tol (tem- COPd 2.16
perature Pdh kW 10.1
operat- PERd % 86.4
ing limit) TOL °C -22
WTOL °C 35
G Con- COPd 2.62
dition Pdh kW 10.7
(-15°CDB/- PERd % 104.8
)
Tbiv COPd 2.62
(bivalent Pdh kW 10.7
tempera- PERd % 104.8
ture) Tbiv °C -15
Rated Psup (at Tdesign kW 2.4
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 2,885
climate consumption
water ηs (Seasonal % 229
outlet space heating
35°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 10
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 9.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.60
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 224.0
Tbiv COPd 4.95
(bivalent Pdh kW 9.8
tempera- PERd % 198.0
ture) Tbiv °C 5
Space heating Warm D Condition Cdh (Degradation heating) 1.0
climate (12°CDB/11°CWB) COPd 7.60
water Pdh kW 6.1
outlet PERd % 304.0
(1)Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C |
(2)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(3)Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB |
(4)Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB |
(5)Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 |
(6)Test at Ta DB/WB 7°C/6°C. According to EN 16147. |
(7)DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed

ETVZ16S18E9W + ETVZ16S23E9W + ETVZ16S18E9W + ETVZ16S23E9W + ETVZ16S18E9W + ETVZ16S23E9W +


Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Heating capacity Min. kW 3.70 (1) 3.96 (1) 4.40 (1)
Nom. kW 5.69 (2) 9.00 (2)
Max. kW 10.18 (1) 10.91 (1) 12.12 (1)
Power input Heating Min. kW 0.88 (3) 0.95 (3) 1.05 (3)
Nom. kW 1.22 (2) 1.80 (2)
Max. kW 2.09 (3) 2.24 (3) 2.49 (3)
Domestic Nom. kWh 2.57 (4) 2.85 (4) 2.57 (4) 2.85 (4) 2.57 (4) 2.85 (4)
hot water
from 10°C
to 50°C

78 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVZ16S18E9W + ETVZ16S23E9W + ETVZ16S18E9W + ETVZ16S23E9W + ETVZ16S18E9W + ETVZ16S23E9W +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Heat up time from 10°C to 50°C hr 1h02min at 1h13min at 1h02min at 1h13min at 1h02min at 1h13min at
7°C ambient 7°C ambient 7°C ambient 7°C ambient 7°C ambient 7°C ambient 2
temperature temperature temperature temperature temperature temperature
COP 4.67 (2) 5.00 (2)
Pump Type Grundfos UPML GEO 25-105 130 PWM
Pump Additional Nominal Heating kPa 97.6 (5) 84.1 (5)
Zone ESP unit
Pump Main Zone Nominal Heating kPa 90.2 (5) 80.0 (5)
ESP unit
Water side Heat Water Heating Nom. l/min 16.3 (2) 25.8 (2)
exchanger flow rate
General Supplier/ Name and address Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
Manu- Name or trademark Daikin Europe N.V.
facturer
details
Product Air-to-water heat pump Yes
descrip- Brine-to-water heat pump No
tion Heat pump combination heater Yes
Low-temperature heat pump No
Supplementary heater integrated Yes
Water-to-water heat pump No
LW(A) SoundIndoor dB(A) 44.0
power level
(according to
EN14825)
LW(A) Sound pow- Outdoor dB(A) 54.0
er level (according
to EN14825)
Sound condition Ecodesign and energy label Sound power in heating mode, measured according to the EN12102 under conditions of the EN14825
Tank Name Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel
domestic hot domestic hot domestic hot domestic hot domestic hot domestic hot
water tank 180 l water tank 230 L water tank 180 l water tank 230 L water tank 180 l water tank 230 L
Space heating Air to Rated airflow (outdoor) m³/h 3,918 3,960
general water
unit
Other Capacity control Inverter
Pck (Crankcase heater mode) kW 0.000
Poff (Off mode) kW 0.021
Psb (Standby mode) kW 0.021
Pto (Thermostat off) kW 0.041
Domestic hot General Declared load profile L XL L XL L XL
water heating

Space heating Inte- Psup kW 9.0


general grated Type of energy input Electrical
supple-
mentary
heater
Domestic hot Average AEC (Annual electricity kWh 935 1,547 935 1,547 935 1,547
water heating climate consumption)
COPdhw 2.62 2.61 2.62 2.61 2.62 2.61

Daikin Altherma high temperature split • EPRA014-018DV 79


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVZ16S18E9W + ETVZ16S23E9W + ETVZ16S18E9W + ETVZ16S23E9W + ETVZ16S18E9W + ETVZ16S23E9W +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Domestic hot Average Heat up time 1h 06min 1h 19min 1h 06min 1h 19min 1h 06min 1h 19min
2 water heating climate ηwh (water heating effi- % 110 108 110 108 110 108
ciency)
Qelec (Daily electricity kWh 4.450 7.320 4.450 7.320 4.450 7.320
consumption)
Reference hot water tem- °C 52.5
perature
Stand-by power input W 34.2 49.2 34.2 49.2 34.2 49.2
Water heating energy efficiency class A
Cold AEC (Annual electricity kWh 1,091 1,814 1,091 1,814 1,091 1,814
climate consumption)
COPdhw 2.26 2.23 2.26 2.23 2.26 2.23
Heat up time 1h 04min 1h 16min 1h 04min 1h 16min 1h 04min 1h 16min
ηwh (water heating effi- % 94 92 94 92 94 92
ciency)
Qelec (Daily electricity kWh 5.170 8.560 5.170 8.560 5.170 8.560
consumption)
Reference hot water tem- °C 52.5
perature
Stand-by power input W 36.4 54.4 36.4 54.4 36.4 54.4
Warm AEC (Annual electricity kWh 843 1,388 843 1,388 843 1,388
climate consumption)
COPdhw 2.90
Heat up time 1h 15min 1h 30min 1h 15min 1h 30min 1h 15min 1h 30min
ηwh (water heating effi- % 122 121 122 121 122 121
ciency)
Qelec (Daily electricity kWh 4.020 6.570 4.020 6.570 4.020 6.570
consumption)
Reference hot water tem- °C 52.5
perature
Stand-by power input W 32.9 46.1 32.9 46.1 32.9 46.1
Space heating Average General Annual energy kWh 7,211
climate consumption
water ηs (Seasonal % 140
outlet space heating
55°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 26
gy consumption
(GCV)
SCOP 3.58
Seasonal space heating A++
eff. class
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.47
Pdh kW 11.2
PERd % 98.8
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.56
(2°CD- Pdh kW 6.9
B/1°CWB) PERd % 142.4
C Condition Cdh (Degradation heating) 1.0
(7°CDB/6°CWB) COPd 4.44
Pdh kW 6.9

80 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVZ16S18E9W + ETVZ16S23E9W + ETVZ16S18E9W + ETVZ16S23E9W + ETVZ16S18E9W + ETVZ16S23E9W +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Average C Con- PERd % 177.6
climate dition 2
water (7°CD-
outlet B/6°CWB)
55°C D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.72
Pdh kW 6.2
PERd % 228.8
Tol (tem- COPd 2.19
perature Pdh kW 12.2
operat- PERd % 87.6
ing limit) TOL °C -10
WTOL °C 55
Rated Psup (at Tdesign kW 0.3
heat -10°C)
output
supple-
mentary
capacity
Tbiv COPd 2.19
(bivalent Pdh kW 12.2
tempera- PERd % 87.6
ture) Tbiv °C -10
Cold General Annual energy kWh 9,654
climate consumption
water ηs (Seasonal % 125
outlet space heating
55°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 35
gy consumption
(GCV)
A Condition Cdh (Degradation heating) 1.0
(-7°CDB/-8°CWB) COPd 2.74
Pdh kW 7.5
PERd % 109.6
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 5.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 4.69
(7°CD- Pdh kW 5.6
B/6°CWB) PERd % 187.6
D Condition COPd 6.12
(12°CDB/11°CWB) Pdh kW 6.2
PERd % 244.8
Tol (tempera- COPd 1.65
ture operating Pdh kW 10.6
limit) PERd % 66.0

Daikin Altherma high temperature split • EPRA014-018DV 81


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVZ16S18E9W + ETVZ16S23E9W + ETVZ16S18E9W + ETVZ16S23E9W + ETVZ16S18E9W + ETVZ16S23E9W +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Cold Tol (tem- TOL °C -22
2 climate perature WTOL °C 55
water operat-
outlet ing limit)
55°C G Con- COPd 2.17
dition Pdh kW 10.3
(-15°CDB/- PERd % 86.8
)
Tbiv COPd 1.90
(bivalent Pdh kW 11.0
tempera- PERd % 76.0
ture) Tbiv °C -18
Rated Psup (at Tdesign kW 1.9
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 4,090
climate consumption
water ηs (Seasonal % 160
outlet space heating
55°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 15
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 2.45
(2°CD- Pdh kW 10.0
B/1°CWB) PERd % 98.0
C Con- Cdh (Degradation heating) 1.0
dition COPd 3.69
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 147.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 5.39
Pdh kW 5.9
PERd % 215.6
Tbiv COPd 3.27
(bivalent Pdh kW 9.9
tempera- PERd % 130.8
ture) Tbiv °C 5
Water H Condi- Max. kW 11.1 11.8
outlet tion (-2°C
45°C /-)
Average General Annual energy kWh 5,726
climate consumption
water ηs (Seasonal % 177
outlet space heating
35°C efficiency)
Prated at -10°C kW 13
Qhe Annual ener- Gj 21
gy consumption
(GCV)
SCOP 4.51
Seasonal space heating A+++
eff. class

82 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVZ16S18E9W + ETVZ16S23E9W + ETVZ16S18E9W + ETVZ16S23E9W + ETVZ16S18E9W + ETVZ16S23E9W +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Average A Condition COPd 3.12
climate (-7°CDB/-8°CWB) Pdh kW 11.1 2
water PERd % 124.8
outlet B Con- Cdh (Degradation heating) 1.0
35°C dition COPd 4.44
(2°CD- Pdh kW 6.7
B/1°CWB) PERd % 177.6
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.84
(7°CD- Pdh kW 5.7
B/6°CWB) PERd % 233.6
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.40
Pdh kW 6.0
PERd % 296.0
Tol (tem- COPd 2.76
perature Pdh kW 11.1
operat- PERd % 110.4
ing limit) TOL °C -10
WTOL °C 35
Tbiv COPd 3.12
(bivalent Pdh kW 11.1
tempera- PERd % 124.8
ture) Tbiv °C -7
Rated Psup (at Tdesign kW 1.4
heat -10°C)
output
supple-
mentary
capacity
Cold General Annual energy kWh 7,417
climate consumption
water ηs (Seasonal % 163
outlet space heating
35°C efficiency)
Prated at -22°C kW 13
Qhe Annual ener- Gj 27
gy consumption
(GCV)
A Condition COPd 3.50
(-7°CDB/-8°CWB) Pdh kW 8.0
PERd % 140.0
B Con- Cdh (Degradation heating) 1.0
dition COPd 5.07
(2°CD- Pdh kW 4.9
B/1°CWB) PERd % 202.8
C Con- Cdh (Degradation heating) 1.0
dition
(7°CD-
B/6°CWB)

Daikin Altherma high temperature split • EPRA014-018DV 83


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
ETVZ16S18E9W + ETVZ16S23E9W + ETVZ16S18E9W + ETVZ16S23E9W + ETVZ16S18E9W + ETVZ16S23E9W +
Technical specifications
EPRA14DV3 EPRA14DV3 EPRA16DV3 EPRA16DV3 EPRA18DV3 EPRA18DV3
Space heating Cold C Con- COPd 6.10
2 climate dition Pdh kW 5.3
water (7°CD- PERd % 244.0
outlet B/6°CWB)
35°C D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB) COPd 7.03
Pdh kW 5.7
PERd % 281.2
Tol (tem- COPd 2.16
perature Pdh kW 10.1
operat- PERd % 86.4
ing limit) TOL °C -22
WTOL °C 35
G Con- COPd 2.62
dition Pdh kW 10.7
(-15°CDB/- PERd % 104.8
)
Tbiv COPd 2.62
(bivalent Pdh kW 10.7
tempera- PERd % 104.8
ture) Tbiv °C -15
Rated Psup (at Tdesign kW 2.4
heat -22°C)
output
supple-
mentary
capacity
Warm General Annual energy kWh 2,885
climate consumption
water ηs (Seasonal % 229
outlet space heating
35°C efficiency)
Prated at 2°C kW 13
Qhe Annual ener- Gj 10
gy consumption
(GCV)
B Con- Cdh (Degradation heating) 1.0
dition COPd 3.67
(2°CD- Pdh kW 9.8
B/1°CWB) PERd % 146.8
C Con- Cdh (Degradation heating) 1.0
dition COPd 5.60
(7°CD- Pdh kW 7.9
B/6°CWB) PERd % 224.0
Tbiv COPd 4.95
(bivalent Pdh kW 9.8
tempera- PERd % 198.0
ture) Tbiv °C 5
D Condition Cdh (Degradation heating) 1.0
(12°CDB/11°CWB)
Space heating Warm D Condition COPd 7.60
climate (12°CDB/11°CWB) Pdh kW 6.1
water PERd % 304.0
(1)Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C |
(2)Condition: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(3)Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 |
(4)Test at Ta DB/WB 7°C/6°C. According to EN 16147. |
(5)DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed |
Cooling: EW 23°C; LW 18°C; ambient conditions: 35°CDB |
Cooling: EW 12°C; LW 7°C; ambient conditions: 35°CDB

Technical Specifications EPRA14DV3 EPRA16DV3 EPRA18DV3


Casing Colour Silver / Black
Material Polyester painted galvanised steel plate
Dimensions Unit Height mm 1,003
Width mm 1,270
Depth mm 533
Packed Height mm 1,340
unit Width mm 1,440
Depth mm 690
Weight Unit kg 146
Packed unit kg 182

84 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
Technical Specifications EPRA14DV3 EPRA16DV3 EPRA18DV3
Packing Material Carton / Wood (pallet) / PE (Straps) / Plastic foil
Weight kg 27
Heat exchanger Length
Rows Quantity
mm 1,200
3
2
Fin pitch mm 2.20
Passes Quantity 10
Face area m² 119
Stages Quantity 44
Tube type ø7 Hi-XSL
Fin Type WF fin
Treatment Anti-corrosion treatment (PE)
Fan Type Propeller fan
Quantity 1
Air flow Heating Nom. m³/min 65.3 66.0
rate Cooling Nom. m³/min 106
Discharge direction Horizontal
Fan motor Quantity 1
Model Brushless DC motor
Output W 210
Drive Direct drive
Speed Steps 12
Heating Nom. rpm 470 475
Cooling Nom. rpm 750
Compressor Quantity 1
Model JT90KFDM@SP
Type Hermetically sealed scroll compressor
Compressor Starting method Inverter driven
PED Category Category III
Operation range Heating Min. °CDB -28.0
Max. °CDB 35
Cooling Min. °CDB 10
Max. °CDB 43
Domestic Max. °CDB 35
hot water Min. °CDB -28
PED Most Name Compressor
critical Ps*V Bar*l 213
part
Piping connections Water inlet heat exchanger diameter inch G1" (male)
Water outlet heat exchanger diameter inch G1" (male)
Sound power level Heating Nom. dBA 56.0 (1) 59.0 (1)
Cooling Nom. dBA 56.0 (1) 59.0 (1)
Sound pressure Heating Nom. dBA 43.0 (2) 48.0 (2)
level Cooling Nom. dBA 43.0 (2) 48.0 (2)
Night Heating dBA 54.0 (2)
quiet
mode
Refrigerant Type R-32
GWP 675.0
Charge TCO2Eq 2.84
Charge kg 4.20
Control Expansion valve
Circuits Quantity 1
Refrigerant oil Type FW68DE
Charged volume l 1.85
Piping connections Piping OU - IU Max. m 50
length
High Design pressure bar 56
pressure
side
Level dif- IU - OU Max. m 10.0
ference
Water Filter ball valve Yes
circuit
Defrost control Sensor for outdoor heat exchanger temperature
Capacity control Method Inverter controlled
Safety devices Item 01 High pressure switch
02 Low pressure switch
03 Fuse
04 Compressor motor protection
05 Pressure relief valve

Daikin Altherma high temperature split • EPRA014-018DV 85


Daikin Altherma high temperature split • EPRA014-018DV

2 Specifications
1 - 1 EPRA014-018DV
Electrical Specifications EPRA14DV3 EPRA16DV3 EPRA18DV3
Power supply Name V3
Phase 1~
2 Frequency
Voltage
Hz
V
50
230
Voltage Min. % -10
range cos phi Nom. 0.90 0.95
Max. 0.98
Max. % 10
Current Minimum Ssc value kVa Equipment complying with EN / IEC 61000-3-12
Recommended fuses A 32
Inverter Min. % 40 (3) 39 (3) 37 (3)
modula-
tion
Wiring connec- For Remark See installation manual outdoor unit
tions power
supply
For Remark See installation manual indoor unit
connec-
tion with
indoor
(1)Cooling Ta 35°C - LWE 18°C (DT = 5°C); Heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) |
(2)The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for
more information. Condition: Ta DB/WB 7°C/6°C - LWC 3 |
(3)Percentage of heating capacity at Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)

86 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

3 Electrical data
3 - 1 Electrical Data
EPRA014-018DV
EPRA014-018DW
3

* Electrical meter specification

Pulse meter type/voltage-free contact for 5 V DC detection by PCB.


-
- Possible number of pulses
·0.1· pulse/kWh
·1· pulse/kWh
·10· pulse/kWh
·100· pulse/kWh
·1000· pulse/kWh
- Pulse duration
minimum On time: ·40ms·
Minimum OFF time: ·100ms·
- Measurement type (depending on installation)
Single-phase AC meter
Three-phase AC meter
Balanced loads
Three-phase AC meter
Unbalanced loads

* Electrical meter installation guideline

- It is the responsibility of the installer to cover the complete power


consumption with electrical meters (combination of estimation and
metering is not allowed).

- Required number of electrical meters

Outdoor unit type EPRA(14/16/18)(D/E)A*


Indoor unit type ETB(H/X)16(D/E)A* ETV(H/X/Z)16S*(D/E)A*
Backup heater
6V 9W 6V 9W
type
Backup heater 1~ 3~ 3~ 1~ 3~ 3~
power supply 230V 230V 400V 230V 230V 400V
Backup heater 2 / 4 3 / 6 2 / 4 3 / 6
6 kW 6 kW
configuration / 6 kW / 9 kW / 6 kW / 9 kW
Normal kWh rate power supply
1~ 1 - - 1 - -
Electrical
3~ balanced - - - - - -
meter type
3~ unbalanced - 1 1 - 1 1
Preferential kWh rate power supply
1~ 2 1 1 2 1 1
Electrical
3~ balanced - - - - - -
meter type
3~ unbalanced - 1 1 - 1 1

4D126533A

Daikin Altherma high temperature split • EPRA014-018DV 87


Daikin Altherma high temperature split • EPRA014-018DV

4 Capacity graphs
4 - 1 Cooling Capacity Graphs
EPRA014-018DV
EPRA014-018DW
4
EPRA14DA* cooling capacity low sound mode
7
Cooling capacity (kW)

4
20 25 30 35 40 43
ambient T

LWT 7C̊ LWT 13C̊ LWT 18C̊

EPRA16DA* cooling capacity low sound mode


7
Cooling capacity (kW)

4
20 25 30 35 40 43
ambient T

LWT 7C̊ LWT 13C̊ LWT 18C̊

EPRA18DA* cooling capacity low sound mode


8

7
Cooling capacity (kW)

4
20 25 30 35 40 43
ambient T

LWT 7C̊ LWT 13C̊ LWT 18C̊

4D126947

88 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

4 Capacity graphs
4 - 1 Cooling Capacity Graphs
EPRA014-018DV

4
EPRA14DAV3 maximum cooling capacity
11

10
Cooling capacity (kW)

6
20 25 30 35 40 43
ambient T

LWT 7C̊ LWT 13C̊ LWT 18C̊

EPRA16DAV3 maximum cooling capacity


12

11
Cooling capacity (kW)

10

7
20 25 30 35 40 43
ambient T

LWT 7C̊ LWT 13C̊ LWT 18C̊

EPRA18DAV3 maximum cooling capacity


13

12
Cooling capacity (kW)

11

10

8
20 25 30 35 40 43
ambient T

LWT 7C̊ LWT 13C̊ LWT 18C̊

4D126949

Daikin Altherma high temperature split • EPRA014-018DV 89


Daikin Altherma high temperature split • EPRA014-018DV

4 Capacity graphs
4 - 2 Heating Capacity Graphs
EPRA014-018DV

4
EPRA14DAV3 integrated maximum heating capacity
11

10
Heating capacity (kW)

7
-25 -20 -15 -7 -2 2 7
ambient T

LWT 55C̊ LWT 65C̊ LWT 70C̊

EPRA16DAV3 integrated maximum heating capacity


12

11
Heating capacity (kW)

10

8
-25 -20 -15 -7 -2 2 7
ambient T

LWT 55C̊ LWT 65C̊ LWT 70C̊

EPRA18DAV3 integrated maximum heating capacity


13

12
Heating capacity (kW)

11

10

8
-25 -20 -15 -7 -2 2 7
ambient T

LWT 55C̊ LWT 65C̊ LWT 70C̊

4D126946A

90 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

4 Capacity graphs
4 - 2 Heating Capacity Graphs
EPRA014-018DV
EPRA014-018DW
4
EPRA14DA* integrated heating capacity low sound mode
8
Heating capacity (kW)

4
-25 -20 -15 -7 -2 2 7
ambient T

LWT 55C̊ LWT 65C̊ LWT 70C̊

EPRA16DA* integrated heating capacity low sound mode


9
Heating capacity (kW)

6
-25 -20 -15 -7 -2 2 7
ambient T

LWT 55C̊ LWT 65C̊ LWT 70C̊

EPRA18DA* integrated heating capacity low sound mode


10
Heating capacity (kW)

6
-25 -20 -15 -7 -2 2 7
ambient T

LWT 55C̊ LWT 65C̊ LWT 70C̊

4D126948

Daikin Altherma high temperature split • EPRA014-018DV 91


Daikin Altherma high temperature split • EPRA014-018DV

5 Capacity tables
5 - 1 Certification Programs
EPRA014-018DV
EPRA014-018DW
Rated data for certification programmes - heating mode

5 EPRA14DAV3 EPRA16DAV3 EPRA18DAV3 EPRA14DAW1 EPRA16DAW1 EPRA18DAW1 Used for:


Tamb EWC LWC HC COP HC COP HC COP HC COP HC COP HC COP
[°C] [°C] [°C] [kW] [kW] [kW] [kW] [kW] [kW]
7/6 30 35 5,69 4,67 9,00 5,00 9,00 5,00 5,90 4,79 9,00 5,00 9,00 5,00 Keymark, EHPA
2/1 (30) 35 7,88 4,31 7,88 4,31 7,88 4,31 7,52 4,09 7,52 4,09 7,52 4,09 EHPA
-7/-8 (30) 35 10,81 3,27 11,78 3,21 12,78 3,15 10,18 3,21 11,40 3,13 12,67 3,05 General
7/6 40 45 7,92 3,42 7,92 3,42 7,92 3,42 7,92 3,42 7,92 3,42 7,92 3,42 General
7/6 47 55 7,24 3,01 7,24 3,01 7,24 3,01 7,24 2,93 7,24 2,93 7,24 2,93 Keymark, EHPA
-7/-8 47 55 9,81 2,25 9,81 2,25 9,81 2,25 9,21 2,22 9,21 2,22 9,21 2,22 GET Databse

Rated data for certification programmes - cooling mode

EPRA14DAV3 EPRA16DAV3 EPRA18DAV3 EPRA14DAW1 EPRA16DAW1 EPRA18DAW1 Used for:


Tamb EWE LWE CC EER CC EER CC EER CC EER CC EER CC EER
[°C] [°C] [°C] [kW] [kW] [kW] [kW] [kW] [kW]
35 23 18 10,55 4,13 11,51 4,11 12,46 4,09 10,55 4,13 11,51 4,11 12,46 4,09 General
35 12 7 6,90 2,7 7,88 2,69 8,86 2,68 6,90 2,7 7,88 2,69 8,86 2,68 DAPT General

Rated data for certification programmes - domestic hot water performance

Indoor unit ETV*16S18(D/E)A* ETV*16S23(D/E)A* ETS(X/H)(B/-)16P30EF ETS(X/H)(B/-)16P50EF Used for:


Outdoor unit EPRA*DAV3 EPRA*DAW1 EPRA*DAV3 EPRA*DAW1 EPRA*DAW1 EPRA*DAV3 EPRA*DAW1 EPRA*DAV3
Application Average climate Average climate Average climate Average climate
Domestic hot water tank
294L 477L
volume 180L 230L
Tapping pattern L XL L XL
Heat-up time (hh:mm:ss) 01:06:36 01:19:36 01:25:18 01:44:06
ϑwh [°C] 52,5 52,5 47,0 44,4 Keymark
Pes [W] 34,2 42,9 49,2 58,5 57,7 57,4 46,5 45,2
V40 [l] 240 298 193,0 245
ηwh [%] 109,5 105,7 108,3 106,6 124 124 125 125
COPDHW [] 2,62 2,51 2,61 2,55 2,85 2,86 2,99 3

Symbols
HC Heating capacity measured according to EN 14511
CC Cooling capacity, measured according to ·EN 14511·.
COP/EER Coefficient of Performance/Energy efficiency ratio according to EN 14511.
EWC Entering water condenser temperature [°C]
LWC Leaving water condensor temperature [°C]
EWE Entering water evaporator temperature [°C]
LWE Leaving water evaporator temperature [°C]
Tamb Ambient temperature [°C DB/WB]
ϑwh Reference Domestic hot water temperature [°C] According to EN16147.
Pes Standby power input According to EN16147.
Veq40 Equivalent domestic hot water volume [l] According to EN16147.
ηwh Efficiency [%] Domestic hot water heating mode According to EN16147.
COPDHW Domestic hot water COP
4D126945E

92 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

5 Capacity tables
5 - 2 Domestic Hot Water performance
EPRA014‐018DV
EPRA014‐018DW
Heat‐up times
5

95,00
EPRA(14/16/18)DA* + ETV*16S23(D/E)A*
EPRA(14/16/18)DA* + ETV*16S18(D/E)A*
85,00

75,00
Heat‐up time (min)

65,00

55,00

45,00

35,00
35 40 45 50 55 60 65

Domestic hot water tank temperature [°C]

Model name Heat‐up time domestic hot water tank until 45°C
EPRA(14/16/18)DA* + ETV*16S18(D/E)A* ∙55∙ min.
EPRA(14/16/18)DA* + ETV*16S23(D/E)A* ∙65∙ min.

Notes
1. Time the indoor unit (heat pump only operation) requires to heat up the domestic hot water tank from 10°C to the indicated 
temperature.
See the operation range for maximum domestic hot water tank temperature during heat pump only operation.

Selection guide for the domestic hot water tank volume
(1)
Veq 40°C = the amount of water with a temperature of 40°C that can be tapped when the domestic hot water tank is heated to a 
certain temperature, and the temperature of the cold inlet water is 10°C.

ETV*16S18(D/E)A*
580
ETV*16S23(D/E)A*
530
Medium tapping pattern EN 16147 (= 2 persons)

480 Large tapping pattern EN 16147 (= 3~4 persons)

X‐large tapping pattern EN 16147 (= 5~6 persons)
430
Veq 40°C [l]

380

330

280

230

180

130
40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Domestic hot water tank temperature [°C]

If a higher daily Veq 40°C is required, then additional heat‐up cycles are required within 24 hours.
See the operation manual for more information.

Notes
(1) According to EN16147.
 4D126944A

Daikin Altherma high temperature split • EPRA014-018DV 93


Daikin Altherma high temperature split • EPRA014-018DV

6 Dimensional drawings
6 - 1 Dimensional Drawings
EPRA014-018DV
EPRA014-018DW
ne nwis
6

f"==[
r ---�7
TI
11210.1,
460
Low pressure switch
1
Muffler2
3
High pressure switch ·41. 7 bar·
4
Accumulator
5
Compressor
6
Solenoid valve (low pressure bypass)
7
Solenoid valve (hot gas pass)
8
Solenoid valve Qiquid)
9
4-way valve
1O
Capillary tube
4-way valve
11
Coil
12 Plate heat exchanger
13 Electronic expansion valve (main)
14 Electronic expansion valve (injection)
15 High pressure switch ·56 bar·
16 Pressure sensor
17 Fan
18 Service port ·5/16"· flare
o::-,,=-�,-"=,c_�-�,-,--,-------_J
19 Shut-off valve / filter (included accessory)
20 Drain elbow (included accessory)
1 Sealing (included accessory)
�--------�

3D124101C

94 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

7 Piping diagrams
7 - 1 Piping Diagrams
EPRA014-018DV
EPRA014-018DW
Outdoor unit
PCB
Cooling
Service port
7
·5/16"· flare
Y1E 11
Electronic expansion
valve S1NPH Pressure sensor
Check valve

R6T
6
* Filter Muffler

1 Economiser
S*PH High pressure
switch
R1T

M1F
12 Y3E
Y4S 16 Leaving water sv
sv

Solenoid valve
sv Capillary tube
Gas R10T 10
Y2S 14 17 M1F Fan motor
20
4-way valve
R5T 17
S2PH

Liquid R9T 9 S1PL Low pressure


5
switch
Entering water

E1HHEX
Accumulator
T
R4
18
13 Y1S
4 S1NPH 22
Plate heat exchanger

sv
*
15 Y3S 1~ LEGEND
S1PH 19
R2T
2
R3T

3 Pinched pipe
8 R7T 7
21 3~
R8T
S1PL

M1C Compressor

1 R1T: Ambient thermistor 9 R9T: Inlet water thermistor Heating


2 R2T: Thermistor (discharge) 10 R10T: Outlet water thermistor Cooling
3 R3T: Thermistor (suction) 11 Y1E: Electronic expansion valve (main)
4 R4T: Thermistor (heat exchanger) 12 Y3E: Electronic expansion valve (injection) High pressure switch ·(5.6 MPa)·
19 S1PH:
(Distributor) 13 Y1S: Solenoid valve (4-way valve)
5 R5T: Thermistor (heat exchanger middle)
14 Y2S: Solenoid valve (low pressure bypass)
20 S2PH: High pressure switch ·(4.17MPa)·
6 R6T: Thermistor (liquid) 15 Y3S: Solenoid valve (hot gas bypass)
7 R7T: Thermistor (compressor shell) 16 Y4S: Solenoid valve (liquid injection)
Screw connection ·1" M· 21 S1PL: Low pressure switch
8 R8T: Thermistor (compressor port) 17
18 E1HHEX: Plate heat exchanger
Heater
22 S1NPH: High pressure sensor

3D124079C

Daikin Altherma high temperature split • EPRA014-018DV 95


8

96
8
8 - 1

 
%/8 *51</:  
1   
%51 ;0 =&1  
/ / 1  
)8 *51</:  
4', =&1     ;0 
=& +$3  
1+] $3
 & 1   
9 =&1  =&1  $3  
=&1  (++(; (++(; (++(;  
57 57  ;0
7$1    
Wr Wr ;0
 

%/.
%/8
5('
5(' %/8
  
$3 /$ 1$ ;$ $3
 
  
)8 ;$ ;$ ;$  
     
)8  
5  .5

=)
 
 $3 $3
 
*51 (
=) .5 ;$ .5   
Wiring diagrams

)8 $3  



  

=)

&  
=) .5 5 ;$ ;$ 
7& 5& ;0    
&   
$3
 (+  
     
=) ;$
( / 1 /% 1% ;$ ;$  
㻿㻱㻱㻌㻺㻻㼀㻱㻌㻡
5(' %/8 )8  
            <6 $3  
;$ ( ;$  
*51
;$  
 
=& =&
Wiring Diagrams - Single Phase

=&1  <6 <6 <6  


1  1 
$3  
㻿㻱㻱㻌㻺㻻㼀㻱㻌㻠  
;$   
/& 1& ;$ ;$ ;$ ;$ 63+  
                      ;$
.5 3!
;$ ;$ .5 .5 .5     
.0 63+  
;$ ;$
5  
3!
 
=) 36   
57 57 57 57 57 57 57 57 57
5 ;$  
95 .5   
9' Wr Wr Wr Wr Wr Wr Wr Wr
;<  
+3 +3 +3  63/
   
                  
;$ 3 㻿㻱㻱㻌㻺㻻㼀㻱㻌㻠  
/5 /5 /5   +3 +3 +3 +3 
;$ ;$ ;$ ;$  
97 '6
;$ ;$ 21  <(  

97  
%6 %6 %6 %6 2)) +$3 ;$  0 <(<(  
97      

㻿㻱㻱㻌㻺㻻㼀㻱㻌㻢 <(  
9' 9' 9' ;$
 &  <(  
  <(
㻿㻱㻱㻌㻺㻻㼀㻱㻌㻡 㻿㻱㻱㻌㻺㻻㼀㻱㻌㻡 ;$  0  

       ;$ ;$   
)8
5 ;$ (  
  
  *51 
㻼㼛㼟㼕㼠㼕㼛㼚㻌㼛㼒㻌㼏㼛㼙㼜㼞㼑㼟㼟㼛㼞㻌㼠㼑㼞㼙㼕㼚㼍㼘 95 06 ;$   
=&1 
613+

0)   


8 9 :  
  
=&       
1 
5(' :+7 %/8  
8 9 :      
06    
0& a
    



Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV
Daikin Altherma high temperature split • EPRA014-018DV

9 Sound data
9 - 1 Sound Pressure Spectrum - Cooling
EPRA014‐018DV
EPRA014‐018DW Cooling Sound
EPRA14* EPRA16* EPRA18*
9
70 70 70 70 70 70
NR75 NR75 NR75

65 65 65
NR70 NR70 NR70

60 60 60 60 60 60
NR65 NR65 NR65

55 55 55
NR60 NR60 NR60
Sound pressure level [dB]

Sound pressure level [dB]

Sound pressure level [dB]
50 50 50 50 50 50
NR55 NR55
NR55
45 45 45
NR50 NR50
NR50
40 40 40 40 40 40
NR45 NR45
NR45
35 35 35
NR40 NR40
NR40
30 NR35 30 30 30 30 NR35 30
NR35

25 NR30 25 NR30 25 NR30

20 NR25 20 20 20 20 NR25 20
NR25

15 NR20 15 15 NR20
NR0 NR5 NR10NR15 NR20 NR0 NR5 NR10NR15
NR0 NR5 NR10 NR15
10 10 10 10 10 10
63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA

Octave band centre frequency [Hz] Octave band centre frequency [Hz] Octave band centre frequency [Hz]

Notes
1. Data is valid at free field condition.
Measured in a semi‐anechoic chamber
2. Data is valid at nominal operation condition.
3. dBA = A‐weighted sound pressure level (A scale according to IEC).
4. Reference acoustic pressure 0 dB = 20 µPa
5. If the sound is measured under actual installation conditions, the measured value will be 
higher due to environmental noise and sound reflections.

Measuring location (discharge side)

 3D126758-1
EPRA014‐018DV
EPRA014‐018DW
EPRA14* EPRA16* EPRA18*
70 70 70 70 70 70
NR75 NR75 NR75
65 65 65
NR70 NR70 NR70
60 60 60 60 60 60
NR65 NR65 NR65

55 55 55
NR60 NR60 NR60
50 50 50 50 50 50
Sound pressure level [dB]

Sound pressure level [dB]
Sound pressure level [dB]

NR55 NR55 NR55


45 45 45
NR50 NR50 NR50
40 40 40 40 40 40
NR45 NR45 NR45
35 35 35
NR40 NR40 NR40
30 NR35 30 30 NR35 30 30 NR35 30

25 NR30 25 NR30 25 NR30

20 NR25 20 20 NR25 20 20 NR25 20

NR20 15 NR20 15 NR20


15
NR0 NR5 NR10 NR15 NR0 NR5 NR10 NR15 NR0 NR5 NR10 NR15
10 10 10 10 10 10
63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA
1/3 Octave band centre frequency [Hz] 1/3 Octave band centre frequency [Hz] 1/3 Octave band centre frequency [Hz]

Notes
1. Data is valid at free field condition.
Measured in a semi‐anechoic chamber
2. Data is valid at nominal operation condition.
3. dBA = A‐weighted sound pressure level (A scale according to IEC).
4. Reference acoustic pressure 0 dB = 20 µPa
5. If the sound is measured under actual installation conditions, the measured value will be higher
due to environmental noise and sound reflections.

Measuring location (discharge side)

 3D126758-2

Daikin Altherma high temperature split • EPRA014-018DV 97


Daikin Altherma high temperature split • EPRA014-018DV

9 Sound data
9 - 2 Sound Pressure Spectrum - Heating
EPRA014‐018DV
EPRA014‐018DW Heating Sound 
EPRA14* EPRA16* EPRA18*

9 70
NR75
70 70
NR75
70 70
NR75
70

65 65 65
NR70 NR70 NR70

60 60 60 60 60 60
NR65 NR65 NR65
55 55 55
NR60 NR60

Sound pressure level [dB]
Sound pressure level [dB]

Sound pressure level [dB]
NR60
50 50 50 50 50 50
NR55 NR55
NR55
45 45 45
NR50 NR50
NR50
40 40 40 40 40 40
NR45 NR45
NR45
35 35 35
NR40 NR40
NR40
30 NR35 30 30 30 30 NR35 30
NR35

25 NR30 25 NR30 25 NR30

20 NR25 20 20 20 20 NR25 20
NR25

15 NR20 15 15 NR20
NR0 NR5 NR10 NR15 NR20 NR0 NR5 NR10 NR15
NR0 NR5 NR10 NR15
10 10 10 10 10 10
63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA

Octave band centre frequency [Hz] Octave band centre frequency [Hz] Octave band centre frequency [Hz]

Notes (graphics only)
1. Data is valid at free field condition.
Measured in a semi‐anechoic chamber
2. Data is valid at nominal operation condition.
3. dBA = A‐weighted sound pressure level (A scale according to IEC).
4. Reference acoustic pressure 0 dB = 20 µPa
5. If the sound is measured under actual installation conditions, the measured value will be higher due to 
environmental noise and sound reflections.

Day Night

Sound power level [dB] Sound power level [dB]

Day Night EPRA14* EPRA16* EPRA18* EPRA14* EPRA16* EPRA18* Measuring location (discharge side)

Low noise level 
Default 60,2 60,2 60,2 53,7 53,7 53,7
∙2∙
Low noise level 
Low noise level ∙2∙ 53,7 53,7 53,7 49,5 49,5 49,5
∙3∙
Full load (maximum fan rps and maximum compressor rps for the dedicated low noise mode)

 3D125215A-1
EPRA014‐018DV
EPRA014‐018DW
EPRA14* EPRA16* EPRA18*
70 70 70 70 70 70
NR75 NR75 NR75
65 65 65
NR70 NR70 NR70
60 60 60 60 60 60
NR65 NR65 NR65

55 55 55
NR60 NR60 NR60
Sound pressure level [dB]

Sound pressure level [dB]

Sound pressure level [dB]

50 50 50 50 50 50
NR55 NR55 NR55
45 45 45
NR50 NR50 NR50
40 40 40 40 40 40
NR45 NR45 NR45
35 35 35
NR40 NR40 NR40
30 NR35 30 30 NR35 30 30 NR35 30

25 NR30 25 NR30 25 NR30

20 NR25 20 20 NR25 20 20 NR25 20

NR20 15 NR20 15 NR20


15
NR0 NR5 NR10 NR15 NR0 NR5 NR10 NR15 NR0 NR5 NR10 NR15
10 10 10 10 10 10
63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA
1/3 Octave band centre frequency [Hz] 1/3 Octave band centre frequency [Hz] 1/3 Octave band centre frequency [Hz]

Notes
1. Data is valid at free field condition.
Measured in a semi‐anechoic chamber
2. Data is valid at nominal operation condition.
3. dBA = A‐weighted sound pressure level (A scale according to IEC).
4. Reference acoustic pressure 0 dB = 20 µPa
5. If the sound is measured under actual installation conditions, the measured value will be higher
due to environmental noise and sound reflections.

Measuring location (discharge side)

 3D125215A-2

98 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

9 Sound data
9 - 3 Sound Pressure Spectrum Quiet Mode
EPRA014‐018DV
Heating Low Sound Mode 2
EPRA014‐018DW
EPRA14* EPRA16* EPRA18*
9
70 70 70 70 70 70
NR75 NR75 NR75

65 65 65
NR70 NR70 NR70

60 60 60 60 60 60
NR65 NR65 NR65

55 55 55
NR60 NR60
Sound pressure level [dB]

Sound pressure level [dB]
NR60

Sound pressure level [dB]
50 50 50 50 50 50
NR55 NR55
NR55
45 45 45
NR50 NR50
NR50
40 40 40 40 40 40
NR45 NR45
NR45
35 35 35
NR40 NR40
NR40
30 NR35 30 30 30 30 NR35 30
NR35

25 NR30 25 NR30 25 NR30

20 NR25 20 20 20 20 NR25 20
NR25

15 NR20 15 15 NR20
NR0 NR5 NR10NR15 NR20 NR0NR5 NR10NR15
NR0NR5 NR10 NR15
10 10 10 10 10 10
63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA
Octave band centre frequency [Hz] Octave band centre frequency [Hz] Octave band centre frequency [Hz]

Notes
1. Data is valid at free field condition.
Measured in a semi‐anechoic chamber
2. Data is valid at nominal operation condition.
3. dBA = A‐weighted sound pressure level (A scale according to IEC).
4. Reference acoustic pressure 0 dB = 20 µPa
5. If the sound is measured under actual installation conditions, the measured value will be
higher due to environmental noise and sound reflections.

Measuring location (discharge side)
 3D125214-1
EPRA014‐018DV
EPRA014‐018DW
EPRA14* EPRA16* EPRA18*

70 70 70 70 70 70
NR75 NR75 NR75
65 65 65
NR70 NR70 NR70
60 60 60 60 60 60
NR65 NR65 NR65

55 55 55
NR60 NR60 NR60
Sound pressure level [dB]

Sound pressure level [dB]

Sound pressure level [dB]

50 50 50 50 50 50
NR55 NR55 NR55
45 45 45
NR50 NR50 NR50
40 40 40 40 40 40
NR45 NR45 NR45
35 35 35
NR40 NR40 NR40
30 NR35 30 30 NR35 30 30 NR35 30

25 NR30 25 NR30 25 NR30

20 NR25 20 20 NR25 20 20 NR25 20

NR20 15 NR20 15 NR20


15
NR0 NR5 NR10 NR15 NR0 NR5 NR10 NR15 NR0 NR5 NR10 NR15
10 10 10 10 10 10
63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA
1/3 Octave band centre frequency [Hz] 1/3 Octave band centre frequency [Hz] 1/3 Octave band centre frequency [Hz]

Notes
1. Data is valid at free field condition.
Measured in a semi‐anechoic chamber
2. Data is valid at nominal operation condition.
3. dBA = A‐weighted sound pressure level (A scale according to IEC).
4. Reference acoustic pressure 0 dB = 20 µPa
5. If the sound is measured under actual installation conditions, the measured value will be higher
due to environmental noise and sound reflections.

Measuring location (discharge side)

 3D125214-2

Daikin Altherma high temperature split • EPRA014-018DV 99


Daikin Altherma high temperature split • EPRA014-018DV

9 Sound data
9 - 3 Sound Pressure Spectrum Quiet Mode
EPRA014‐018DV
EPRA014‐018DW Cooling: Low Sound Mode 2
EPRA14* EPRA16* EPRA18*
9
70 70 70 70 70 70
NR75 NR75 NR75
65 65 65
NR70 NR70 NR70

60 60 60 60 60 60
NR65 NR65 NR65
55 55 55
NR60 NR60 NR60

Sound pressure level [dB]

Sound pressure level [dB]
Sound pressure level [dB]

50 50 50 50 50 50
NR55 NR55
NR55
45 45 45
NR50 NR50
NR50
40 40 40 40 40 40
NR45 NR45
NR45
35 35 35
NR40 NR40
NR40
30 NR35 30 30 30 30 NR35 30
NR35

25 NR30 25 NR30 25 NR30

20 NR25 20 20 20 20 NR25 20
NR25

15 NR20 15 15 NR20
NR0 NR5 NR10NR15 NR20 NR0 NR5 NR10NR15
NR0 NR5 NR10 NR15
10 10 10 10 10 10
63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA
Octave band centre frequency [Hz] Octave band centre frequency [Hz] Octave band centre frequency [Hz]

Notes
1. Data is valid at free field condition.
Measured in a semi‐anechoic chamber
2. Data is valid at nominal operation condition.
3. dBA = A‐weighted sound pressure level (A scale according to IEC).
4. Reference acoustic pressure 0 dB = 20 µPa
5. If the sound is measured under actual installation conditions, the measured value will be
higher due to environmental noise and sound reflections.

Measuring location (discharge side)

 3D126757-1
EPRA014‐018DV
EPRA014‐018DW
EPRA14* EPRA16* EPRA18*
70 70 70 70 70 70
NR75 NR75 NR75
65 65 65
NR70 NR70 NR70
60 60 60 60 60 60
NR65 NR65 NR65

55 55 55
NR60 NR60 NR60
Sound pressure level [dB]

Sound pressure level [dB]
Sound pressure level [dB]

50 50 50 50 50 50
NR55 NR55 NR55
45 45 45
NR50 NR50 NR50
40 40 40 40 40 40
NR45 NR45 NR45
35 35 35
NR40 NR40 NR40
30 NR35 30 30 NR35 30 30 NR35 30

25 NR30 25 NR30 25 NR30

20 NR25 20 20 NR25 20 20 NR25 20

NR20 15 NR20 15 NR20


15
NR0 NR5 NR10 NR15 NR0 NR5 NR10 NR15 NR0 NR5 NR10 NR15
10 10 10 10 10 10
63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA 63 125 250 500 1000 2000 4000 8000 dBA
1/3 Octave band centre frequency [Hz] 1/3 Octave band centre frequency [Hz] 1/3 Octave band centre frequency [Hz]

Notes
1. Data is valid at free field condition.
Measured in a semi‐anechoic chamber
2. Data is valid at nominal operation condition.
3. dBA = A‐weighted sound pressure level (A scale according to IEC).
4. Reference acoustic pressure 0 dB = 20 µPa
5. If the sound is measured under actual installation conditions, the measured value will be higher
due to environmental noise and sound reflections.

Measuring location (discharge side)

 3D126757-2

100 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Altherma high temperature split • EPRA014-018DV

10 Installation
10 - 1 Installation Method
EPRA014-018DV
EPRA014-018DW
Minimum space for air passage
10
Top-side obstacle
≤ 500 ≤ 500
≤ 500 ≤ 500

≥ 300
≥ 1000

≥ 1000

≥ 1000
≥ 1000
≥ 1000
≥ 500

X ( X<H )

X ( X<H )
≥ 1000

≥ 150 ≥ 300 ≥ 300


≥ 500

No top-side obstacle
General
≥ 500
≥ 300

≥ 500 ≥ 300

wall height unrestricted


X ( X<H )

≥ 150
H

≥ 100 ≥ 500

3D124412

Daikin Altherma high temperature split • EPRA014-018DV 101


Daikin Altherma high temperature split • EPRA014-018DV

11 Operation range
11 - 1 Operation Range
EPRA014-018DV + ETS*(D/E)*
ETV*(D/E)* ETB*(D/E)*
Outdoor temperature [°C DB]
EPRA014-018DW Outdoor temperature [°C DB]
40
40

11

Heating mode
35
Heating mode

35
30
30
2
2
0
0
1
1
0
0

0
0
-1
-1
0
0
-2
-2
0
0 -2
-2 -3 8
-3 8 3
3 0
0 20 0 40 50 60 70
20 0 40 50 60 70 10 65
10 65 Leaving water condensor temperature [°C]
Leaving water condensor temperature [°C]

ETV*U*E*
+ ETB*(D/E)*+ ETS*(D/E)*
ETV*(D/E)* Outdoor temperature [°C DB]
Outdoor temperature [°C DB]
50 40
35

Heating mode
43 30
40 2
Cooling mode

0
1
30 0

2 0
0 -1
0
1 -2
0 0
-2
-3 8
3
0
1 2 2 2 3 3 4 4 5 20 0 40 50 60 65 68
0 10
5 7 10 5 0 2 5 0 5 0 5 0 Leaving water condensor temperature [°C]
0
Leaving water evaporator temperature [°C]

Legend
Backup heater only operation
No outdoor unit operation
Outdoor unit operation if setpoint ≥ ·20·
Pull-down area
Outdoor unit operation if setpoint >·55·°C and ΔT = ·10·°C (ΔT = outlet temperature – inlet temperature)
In case valve kit ·AFVALVE1· is part of the system, then the minimum setpoint is ·7·°C.
Remark
In restricted power supply mode, the outdoor unit, booster heater and backup heater can only operate separately.
3D125788C

EPRA014-018DV
EPRA014-018DW
Domestic hot water heating mode
EKHWS*200*
ETV* EKHWP* + ETS* + EKHWS*250* + Third-party with identical specifications as ·EKHWS*200*·

EKHWS*300*
Outdoor temperature [°C DB] Outdoor temperature [°C DB]
40 40
35 35
30 30

20 20

10 10

0 0

-10 -10

-20 -20

-28 -28
-30 -30
10 20 30 40 50 60 65 10 20 30 40 50 60 70 75
0 0
Leaving water condensor temperature [°C] Leaving water condensor temperature [°C]
57 63 57 63

Outdoor temperature [°C DB]

40
35
EKHWS*150* 30

EKHWS*180* 20

+ 10
Third-party with identical specifications as ·EKHWS*150*·
0

Legend -10

Backup heater only operation (or booster heater, if part of the system)
-20
Remark
-28
1. In restricted power supply mode (·EKHW*· only ), the outdoor unit, -30
10 20 30 40 50 60
booster heater and backup heater can only operate separately. 0
2.Third-party with identical specifications as ·EHKWS*150*· Leaving water condensor temperature [°C] 48 55
Coil surface >·1.05·m2
Tank thermistor: top part of heat pump coil. Small overlap.
3.Third-party with identical specifications as ·EKHWS*200*·
Coil surface >·1.8·m2
Tank thermistor: top part of heat pump coil. Small overlap.

3D125789B

102 Daikin Altherma high temperature split • EPRA014-018DV


Daikin Europe N.V.  Naamloze Vennootschap · Zandvoordestraat 300 · 8400 Oostende · Belgium · www.daikin.eu · BE 0412 120 336 · RPR Oostende (Responsible Editor)

The present publication is drawn up by way of information only and does not constitute
an offer binding upon Daikin Europe N.V. / Daikin Central Europe HandelsGmbH. Daikin
Europe N.V. / Daikin Central Europe HandelsGmbH have compiled the content of this
publication to the best of their knowledge. No express or implied warranty is given for
the completeness, accuracy, reliability or fitness for particular purpose of its content and
the products and services presented therein. Specifications are subject to change without
EEDEN22 03/2022
prior notice. Daikin Europe N.V. / Daikin Central Europe HandelsGmbH explicitly rejects
any liability for any direct or indirect damage, in the broadest sense, arising from or related
to the use and/or interpretation of this publication. All content is copyrighted by Daikin
Europe N.V.

You might also like